3” SS 316 G EXPANSION PIPE PNEUMATIC TEST
CERTIFICATE
AS PER DECREE NO AR 00 NMIDT Di OF AUGUST 5th,
Certificate * 19/08/20-01 Date: 18/08/2021
INSPECTION SITE: ‘CLIENT REQUESTING INSPECTION:
BINES WORKSHOP COSL SEEKER
FEATURES OF TRANSPORTING VESSEL |
‘Type: 3° SS G Expansion Pipe Air FLANGE RATING: ASTM 105/PN16
‘Transported fluid: oe een
DESIGN CODE: ASME SEC VII DIV.
DESIGN PRESSURE (MAWP) ‘Test pressure :1.2xWP
Work Details:
Test Volume: N/A
INSPECTION TYPE: PNEUMATIC
START OF TEST
Date: 19/08/2020 Pressure: Opsi. Temperature: 15°.
Fluid: Air
End Of Test
Date: 18/08/2020, Pressure: 150.7psi_ Temperature: 17°C,
Total Soak in Time : 30min,
MANOMETERS
Make: WIKA: 90259480-2-91 Calibration date: 22/05/17
‘As per procedure # BINDE-14-001, pressure was introduced in the hose in a step wise pattern, at
increments of 14.5psi, and carried out preliminary soaking for Smin. to achieve a stable pressure until
test pressure is attained at 150psi and soaked for 30min.
Observations: No pressure drop and or leaks were alerted during the 30minutes pneumatic
exercise,
Results: The Expansion pipe is serviceable.