AIR CONDITIONER

REMOTE CONTROLLER ILLUSTRATION

The design and specifications are subject to change without prior


notice for product improvement. Consult with the sales agency or
manufacturer for details.

CR246-RG66B6(A1,A2)EFU1 Thank you very much for purchasing our air conditioner.
Please read this owner's manual carefully before using
16117000A33113 your air conditioner. Make sure to save this manual for
2019116 future reference.
Function Buttons
CONTENTS Before you begin using your new air conditioner, make sure to familiarize yourself with its remote
control. The following is a brief introduction to the remote control itself. For instructions on how to
operate your air conditioner, refer to the How to Use The Basic/Advance Functions section of
this manual.
Remote controller Specifications................................................... 1 NOTE:Please do not select HEAT mode if the machine you purchased is cooling only
type. Heat mode is not supported by the cooling only appliance.
Function buttons .................. ......................................................... 2 FAN
ON/OFF Selects fan speeds in
Turns the unit on or off the following order:
Handling the remote controller ...................................................... 5 AUTOg LOW g MED g
MODE HIGH
Remote LCD screen indicators ..................................................... 6 NOTE: Holding this button
Scrolls through operation
modes as follows: down for 2 seconds will
How to use the basic functions........................................................ 7 AUTO g COOL g DRY g activate Silence feature.
HEAT g FAN TEMP
How to use the advanced functions ............................................... 13 Increases temperate in
Sleep 1OF(1OC) increments.
Max. temperature is
Saves energy during 86OF(30OC) .
Remote Controller Specifications sleeping hours.
Mode ON/OFF Fan TEMP
Decreases temperate in
Model RG66B6/BGEFU1, RG66A2/BGEFU1, RG66A1/BGEFU1 1OF(1OC) increments.
Min. temperature is
TIMER 62OF(17OC) .
Rated Voltage 3.0V(Dry batteries R03/LR03×2) Sets timer to turn unit on Timer Sleep Swing
and off(see How to Use NOTE: Press and hold
and buttons together for
Signal Receiving Range 8m Basic Functions for
Follow 3 seconds will alternate the
instructions) LED Direct
me
temperature display
Environment 23OF~140OF(-5OC~60OC) LED Short Self between the OC & OF
, Turbo cut clean scale.
Turns indoor unit s LED
display on and off.
SWING
Starts and stops horizontal
NOTE: FOLLOW ME louver auto swing feature.
Temperature sensing and
Buttons design is based on typical model and might be slightly different from the room temperature display DIRECT
actual one you purchased, the actual shape shall prevail. button. Used to set the desired
All the functions described are accomplished by the unit. If the unit has no this up/down air flow direction.
feature, there is no corresponding operation happened when press the relative The louver changes 6
TURBO
button on the remote controller. degree in angle for each
,, ,, Enables unit to reach press.
,,When there are wide differences between Remote controller Illustration and ,,
,, ,,
USER'S MANUAL on function description, the description of USER'S MANUAL preset temperature in
shall prevail. shortest possible time SELF CLEAN
Starts and stops the unit
SHORT CUT self clean feature.
Sets and activates your
favourite pre-settings.

Model: RG66A2/BGEFU1

1 2
FAN FAN
ON/OFF
Selects fan speeds in ON/OFF Selects fan speeds in
Turns the unit on or off
the following order: Turns the unit on or off the following order:
AUTOg LOW g MEDg HIGH AUTOg LOW g MED g
MODE HIGH
Scrolls through operation NOTE: Holding this button MODE
down for 2 seconds will Scrolls through operation NOTE: Holding this button
modes as follows:
activate Silence feature. modes as follows: down for 2 seconds will
AUTO g COOL g DRY g
AUTO g COOL g DRY g activate Silence feature.
HEAT g FAN TEMP
Increases temperate in HEAT g FAN TEMP
SLEEP 1OF(1OC) increments. Max. Increases temperate in
Saves energy during temperature is 86OF(30OC). ECO 1OF(1OC) increments.
sleeping hours. Starts and stops energy Max. temperature is
TEMP efficient feature. If hold 86OF(30OC) .
Decreases temperate in down this button for
TIMER Mode ON/OFF Fan
1OF(1OC) increments. Min. more than 2 seconds, Mode ON/OFF Fan TEMP
Sets timer to turn unit on temperature is 62OF(17OC). the sleep feature is Decreases temperate in
and off(see How to Use NOTE: Press and hold activated. 1OF(1OC) increments.
Basic Functions for and buttons together for Min. temperature is
instructions) 3 seconds will alternate the TIMER 62OF(17OC) .
Timer Sleep
temperature display between Sets timer to turn unit on Timer Swing
the OC & OF scale. and off(see How to Use NOTE: Press and hold
LED
, LED Follow Basic Functions for and buttons together for
Turns indoor unit s LED me Swing Button Follow Direct 3 seconds will alternate the
display on and off. instructions) LED me
Used to stop or start horizontal temperature display
Short Self O O
Turbo
cut clean louver movement or set the LED Short Self between the C & F
desired up/down air flow , Turbo cut clean scale.
FOLLOW ME Turns indoor unit s LED
Temperature sensing and direction. The louver changes display on and off.
6 degree in angle for each SWING
room temperature display Starts and stops horizontal
press. If keep pushing more
button. than 2 seconds, the louver FOLLOW ME louver auto swing feature.
will swing up and down Temperature sensing and
TURBO automatically. DIRECT
room temperature display
Enables unit to reach Swing Button button. Used to set the desired
preset temperature in Used to stop or start vertical up/down air flow direction.
shortest possible time louver movement and set the The louver changes 6
TURBO
desired left/right air flow degree in angle for each
Enables unit to reach press.
direction. The vertical louver
SHORT CUT changes 6 degree in angle preset temperature in
Sets and activates your for each press. If keep shortest possible time SELF CLEAN
favourite pre-settings. pushing more than 2 seconds, Starts and stops the unit
the vertical louver auto swing SHORT CUT self clean feature.
feature is activated. Sets and activates your
SELF CLEAN favourite pre-settings.
Starts and stops the unit
self clean feature. Model: RG66B6/BGEFU1

Model: RG66A1/BGEFU1

3 4
HANDLING THE REMOTE CONTROLLER Remote LCD Screen Indicators
TIPS FOR USING REMOTE CONTROL Information are displayed when the remote controller is powered up.
NOT SURE WHAT A FUNCTION DOES?
Refer to the How to Use Basic Functions The remote control must be used within 8
and How to Use Advanced Functions meters of the unit.
sections of this manual for a detailed The unit will beep when remote signal is ON/OFF display
description of how to use your air conditioner. received. Appears when the unit
Curtains, other materials and direct is turned on, and disappears
SPECIAL NOTE sunlight can interfere with the infrared when the it is turned off.
signal receiver.
Button designs on your unit may differ Remove batteries if the remote control
slightly from the example shown. will not be used more than 2 months.
If the indoor unit does not have, a particular
function, pressing that function s button on Transmission Indicator
the remote control will have no effect. Lights up when remote Displays when ECO feature
sends signal to indoor is activated(some units)
INSERTING AND REPLACING BATTERIES unit
Put two batteries(optional parts) in the remote Battery display
control before use: MODE display Low battery detection
1. Remove the back cover from the remote Displays the current
Temperature/Timer display
control, exposing the battery compartment. mode, including:
2. Insert the batteries, paying attention to Displays the set temperature
match up the (+) and (-) ends of the batteries by default, or timer setting
with the symbols inside the battery when using TIMER ON/OFF
compartment. functions
TIMER ON display Temperature range:
3. Install the back cover on.
( ) 62-86oF(17-30oC)
Displays when TIMER Timer setting range:
INSTALLING REMOTE CONTROL HOLDER ON is set 0-24 hours
TIMER OFF display This display is blank when
The remote controller can be attached to a wall Remove the back cover
( ) operating in FAN mode.
or stand by using a remote controller holder to install batteries
(optional part, not supplied with the unit). Displays when TIMER
OFF is set Fan speed display
1. Before installing the remote controller, check
Displays selected fan speed:
that the air conditioner receives the signals
properly. Low speed
Silence feature
2. Install the holder with two screws. display Not available for Medium speed
3. Put the remote controller in the holder. this unit
Follow me feature
display Not available for High speed
BATTERY NOTES this unit
LOCK feature
For optimum product performance: display Sleep mode display Auto fan speed
Do not mix old and new batteries, or
This fan speed can not be
batteries of different types.
adjusted in AUTO or DRY
Do not leave batteries in the remote control
, mode.
if you don t plan on using the device for
more than 2 months.
Note:
BATTERY DISPOSAL All indicators shown in the figure are for the purpose of clear presentation. But during the actual
Put the remote controller
in the holder. operation only the relative functional signs are shown on the display window.
Do not dispose of batteries as unsorted
municipal waste. Refer to local laws for
proper disposal of batteries.

5 6
How To Use The Basic Functions How To Use The Basic Functions

SETTING TEMPERATURE
The operating temperature range for units is DRY operation(dehumidifying)
62-86 OF(17-30 OC). You can increase or
1. Press the MODE button to select DRY
decrease the set temperature in 1 OF( 1 OC)
mode.
increments.
2. Set your desired temperature using the
Temp or Temp button.
3. Press the ON/OFFbutton to start the unit.
AUTO operation ,
3 NOTE: FAN SPEED can t be changed in
In AUTO mode, the unit will automatically DRY mode.
1 Mode ON/OFF Fan 2 select the COOL, FAN, HEAT or DRY mode
based on the set temperature. 1 Mode ON/OFF Fan 2
1. Press the MODE button to select Auto mode.
2. Set your desired temperature using the 3
Timer Swing Temp or Temp button.
3. Press the ON/OFF button to start the unit. Timer Swing

LED Follow
me
Direct ,
NOTE: FAN SPEED can t be set in Auto mode. LED Follow
me
Direct

Short Self
Turbo clean
cut
Short Self
Turbo clean
cut

COOL operation
FAN operation
1. Press the MODE button to select
COOL mode. 1. Press the MODE button to select FAN
2. Set your desired temperature using 4 mode.
the Temp or Temp button. 1 Mode ON/OFF Fan 2
2. Press the FAN button to select the
3. Press the FAN button to select the 2
fan speed.
1 Mode ON/OFF Fan
fan speed. 3
4. Press the ON/OFF button to start the 3. Press the ON/OFFbutton to start the
unit. unit. Timer Swing
3 ,
Timer Swing NOTE: You can t set temperature in FAN, LED Follow Direct
me
mode. As a result, your remote control s
Follow
LED
me
Direct
LCD screen will not display temperature. Turbo Short
cut
Self
clean

Short Self
Turbo clean
cut

7 8
How To Use The Basic Functions Setting the TIMER function NOTE: When setting the TIMER ON or
TIMER OFF functions, up to 10 hours,
Your air conditioning unit has two the time will increase in 30 minute
HEAT operation timer-related functions: increments with each press. After 10
TIMER ON- sets the amount of timer after hours and up to 24, it will increase in 1
1. Press the MODE button to select which the unit will automatically turn on. hour increments. The timer will revert to
HEAT mode. TIMER OFF- sets the amount of time after zero after 24 hours.
2. Set your desired temperature using which the unit will automatically turn off. You can turn off either function by
the Temp or Temp button. TIMER ON function setting its timer to " 0.0h " .
3. Press the FAN button to select the The TIMER ON function allows you to set
fan speed. a period of time after which the unit will 1 2
4. Press the ON/OFF button to start the automatically turn on.
x5
unit. 1. Press the Timer button, the Timer on
Timer or
indicator " " and time display.
2 Note: This number indicates the
1 Mode ON/OFF Fan
amount of time after the current time
4 that you want the unit to turn on.
3 For example, if you set TIMER ON for
NOTE: As outdoor temperature drops, the 3 4
Timer Swing
,
performance of your unit s HEAT function
2.5 hours, " 2.5h " will appear on the
3sec
screen, and the unit will turn on after
may be affected. In such instances, we 2.5 hours.
LED Follow Direct
me recommend using this air conditioner in 2. Press the Temp or Temp button
Turbo Short Self conjunction with other heating appliance. repeatedly to set the time when you want
cut clean
the unit to turn on. ON
/OFF

3. Wait 3 seconds, then the TIMER ON FA


MO

N
DE

TE
MP TIM
ER
SH
CUORT
T

function will be activated. The digital


SLEE ON
P TIM
ER
OF
F

display on your remote control will then


return to the temperature display. The
" " indicator remains on and this Example: Setting unit to turn on after 2.5
function is activated. hours.

TIMER OFF function


The TIMER OFF function allows you to 1 2
set a period of time after which the unit x10
will automatically turn off.
1. Press the Timer button, the Timer off Timer or
indicator " " and time display.
Note: This number indicates the
amount of time after the current time
that you want the unit to turn off.
For example, if you set TIMER OFF for 5 3 4
hours, " 5.0h " will appear on the screen, 3sec
and the unit will turn off after 5 hours.
2. Press the Temp or Temp button
repeatedly to set the time when you want
the unit to turn off.
3. Wait 3 seconds, then the TIMER OFF MO
ON

DE
/OFF

SH
CUORT

function will be activated. The digital


FA
N TE T
MP TIME
R ON
SLEE
P TIME
R OF
F

display on your remote control will then


return to the temperature display. The
" " indicator remains on and this Example: Setting unit to turn off after 5
function is activated. hours.

9 10
Setting both TIMER ON and TIMER OFF at the same time Unit turns Unit turns
Timer starts
Keep in mind that the time periods you set for both functions refer to hours after the ON OFF
current time. For example, say that the current time is 1:00 PM, and you want the unit
to turn on automatically at 7:00 PM. You want it to operate for 2 hours, then automa-
tically turn off at 9:00 PM.
Do the following:

1 2 3 4
X12
Current 2PM 3PM 4PM 5PM 6PM 7PM 8PM 9PM
time 1PM
Timer or
6 hours later
8 hours later

ON
/OFF

MO
DE
SH
CUORT
TE T
MP TIM

NOTE:
ER
ON

The device could comply with the local national regulations.


5 6 7 8 In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
X16 In USA, this device complies with part 15 of the FCC Rules. Operation is subject to
3sec the following two conditions:
(1) This device may not cause harmful interference, and
Timer or
(2) this device must accept any interference received, including interference that
may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
ON
/OFF

MO
DE
SH
CUORT

provide reasonable protection against harmful interference in a residential installation.


TE T
MP TIM
ER
ON

This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
Example: Setting the unit to turn on after 6 hours, operate for 2 hours, then turn off to radio communications. However, there is no guarantee that interference will not
(see the figure below) occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
Your remote display and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Timer is set To turn ON Connect the equipment into an outlet on a circuit different from that to which the
6 hours from current time receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not approved by the party responsible for compliance
could void user s authority to operate the equipment.

Timer is set to turn OFF


8 hours from current time

11 12
How To Use The Advanced Functions How To Use The Advanced Functions

ECO function
Silence function
NOTE: This function is only available under
COOL mode. Hold down Fan speed button for 2 seconds
Used to enter the energy efficient mode. to activate/cancel Silent mode. Due to low
Under cooling mode, press this button, frequency operation of compressor, it may
the remote controller will adjust the result in insufficient cooling and heating
Hold down Fan capacity. (Applicable to the air conditioner
temperature automatically to 24OC, fan
button for 2 with Silent feature only)
speed of Auto to save energy(but only
seconds to activate
if the set temperature is less than 24OC).
Silence function
If the set temperature is above 24OC ,
Mode ON/OFF Fan Mode ON/OFF Fan
press the ECO button, the fan speed 8OC Heating Function
will change to Auto, the set temperature
will remain unchanged. When the air conditioner operates
Hold down this under heating mode with the set
NOTE:
Timer Swing button for 2 Timer Sleep Press this button temperature of 17 OC, press Temp ,, ,,
Pressing the ECO button, or modifying
the mode or adjusting the set temperature seconds to activate twice in one second button twice in one second will
to less than 24OC will stop ECO operation.
LED Follow
me Direct Sleep function LED Follow
me to activate 8OC activate 8 Degree heating function.
Under ECO operation, the set temper- heating function The unit will operate at a setting
Self Self
Turbo Short Turbo Short
temperature of 8 OC.,,The indoor
ature should be 24OC or more. it may cut clean cut clean

unit display shows FP .


,,
result in insufficient cooling. If you feel
uncomfortable, just press the ECO
button again to stop it.
Self clean function
SLEEP Function Airborne bacteria can grow in the moisture
Hold together for one second
that condenses around heat exchanger in
The SLEEP function is used to decrease to activate LOCK function
, the unit. With regular use, most of this
energy use while you sleep (and don t moisture is evaporated from the unit.
need the same temperature settings to LOCK function When the self clean feature is activated,
stay comfortable). This function can your unit will clean itself automatically. After
only be activated via remote control. Press Turbo button and Self clean SHORTCUT function
cleaning, unit will turn off automatically.
the ,detail, see ,, sleep operation ,, in
,For
, USER S MANUAL.
,, button simultaneously for one second
Used to restore the current settings or You can use self clean feature as often as
to lock or unlock the keyboard. you like.
resume previous settings.
Note: The SLEEP function is not Note: You can only activate this function
Push this button when remote controller
available in FAN or DRY mode. TURBO function in COOL or DRY mode.
is on, the system will automatically revert
back to the previous settings including
The TURBO function makes the unit work
operating mode, setting temperature, fan
Follow me function extra hard to reach your present temperature
speed level and sleep feature (if activated).
in the shortest amount of time possible.
The Follow me function enables the If pushing more than 2 seconds, the
When you select TURBO feature in COOL
remote control to measure the temperature system will automatically restore the
mode, the unit will blow cool air with
at its current location and send this signal current operation settings including
strongest wind setting to jump-start the
to the air conditioner every 3 minutes interval. operating mode, setting temperature,
cooling process. fan speed level and sleep feature
When using AUTO, COOL, or HEAT modes, When you select TURBO feature in HEAT
measuring ambient temperature from the (if activated ).
mode, for units with Electric heat elements,
remote control (instead of from the indoor the Electric Heater will activate and
unit itself) will enable the air conditioner to jump-start the heating process.
optimize the temperature around you and
ensure maximum comfort.