You are on page 1of 3

[Assimilation Alex] Codes (0801-0900)

Study online at quizlet.com/_2bwhzu

1. 1 Minimum number of aisles for Class 'A' stores. 24. 4 Minimum fire resistance rating for a firewall.
hrs.
2. 1.00 Minimum width of an aisle serving an occupant of 60
mtr. or more serving two sides for a public assembly 25. 7 Maximum force in kilograms required for a panic
building. kgs. hardware.
3. 1.20 Minimum width of ramps of 3 stories or more in height. 26. 9 Maximum reduction in width of a stair by a handrail.
mts. cms.
4. 1.50 For Refineries, distilleries, and chemical plants, the 27. 10- Standard slope of Class 'B' ramp in percentage.
mts. minimum height for a fence. 17%
5. 1.50 Minimum clear width of aisles for a Class 'A' store. 28. 15.00 Minimum travel distance from any individual room
mts. mts. subject to occupancy by not more 6 persons.
6. 1.80 Minimum width of an aisle for an educational use 29. 15.25 Minimum tread for a fire escape stair for small
mts. building. cms. buildings.
7. 1.80 Minimum height of fence for a lumber yard for exterior 30. 15 Minimum height of buildings requiring automatic
mts. storage of lumbers. mts. sprinkler protection.
8. 1.83 Minimum width of an aisle for custodial care 31. 19 Maximum height of riser for Class 'A' stairs.
mts. institutions. cms.
9. 1.98 Minimum headroom clearance for a fire escape stair 32. 20 Maximum number of occupant for a subdivided room
mts. for small buildings. or space by a folding partition.
10. 2 Minimum number of exit for an Institutional type of 33. 20.5 Maximum change in elevation between the interior of
structure. cms. a door to the outside of it other than a balcony.
11. 2.5 Minimum increase in width for an aisle per linear meter. 34. 20 Maximum height of riser for Class 'B' Stairs.
cms. cms.
12. 2.13 Minimum headroom clearance for a fire escape stair 35. 22.9 Maximum rise of fire escape stair for existing stairs.
mts. for existing stairs. cms.
13. 2.44 Minimum width of an aisle for hospitals or nursing 36. 23.00 Maximum distance of travel from the high hazard area
mts. homes. mts. to an exit.
14. 3 Number of exits for place of assembly for 600-1000 37. 23 Minimum distance travel to an exit for storage
occupants. mts. occupancies of high hazard commodities.
15. 3.00 Minimum distance of an incinerator from any structure 38. 25 Minimum width of a stair width for Class 'A' stairs.
mts. used other than a single family dwelling. mm.
16. 3.66 Minimum clear width of an exit access through a 39. 25 Length of a nosing or effective projection over the
mts. covered mall. mm level immediately below it for tread below 25 cms in
dimension.
17. 3.66 Maximum height between landings for Class 'B' ramp.
mts. 40. 30.5 Maximum rise for a fire escape for very small
cms. buildings.
18. 3.66 Maximum height between landings for fire escape for
mts. existing stairs. 41. 30.5 Maximum rise of fire escape stair for a small building.
cms.
19. 3.66 Maximum height between landings for a fire escape
mts. stair for existing stairs. 42. 30.50 Classified as mercantile occupancies, the travel
mts. distance from exits shall be.
20. 3.70 Maximum width of sumps for the retention of oil and
mts. petroleum products. 43. 30 Maximum travel distance from the door of any room
mts. to exit for hotels with sprinkler.
21. 3.70 Maximum height between landings for a Class 'B' stairs.
mts. 44. 30 Maximum travel distance between room door
mts. intended as exit access and exit with sprinkler system
22. 4.50 Minimum width of any driveway in and around a
for institutional use.
mts. lumber yard / piles.
45. 31 Maximum travel distance from the main entrance
23. 4.60 Occupant load per person for laboratories.
mts. door to exit for apartments with sprinkler.
sqm.
46. 37.8 Temperature rating at flash point. 68. 112 cms. Minimum width of stair for Class 'B' stairs
oC serving more than 50 persons.
(100
69. 763 cms. Standard inner radius of a curved stair in
oF)
business occupancies.
47. 37.8 A combustible liquid is any liquid having a flash
70. Assembly Courtrooms with an occupant load of more
oC point at or above.
than 100 are classified under what
(100
classification of occupancy.
oF)
71. Assembly Under what classification of occupancy does
48. 38 Maximum horizontal projection of a handrail over a
pool rooms fall.
mm. stair.
72. Assembly Armories with an occupant load of more than
49. 50- Maximum occupant load for a class C public
100 are classified under what classification of
300 assembly.
occupancy
50. 55.9 Minimum horizontal dimension of any landing of
73. Automatic An integrated system of under ground or
cms. platform for existing stairs for fire escape.
Fire overhead piping or both connected to a
51. 55.9 Minimum width for fire escape for existing stairs. Suppression source of extinguishing agents or medium and
cms. System designed in accordance with fire protection
engineering standards which when actuated
52. 55.9 Minimum width of landing for a fire escape stair for
by its automatic detecting device, suppresses
cms. existing stairs.
fire within the area protected.
53. 61 cms. Minimum width of a door for family day care homes.
74. Boiling The temperature at which a liquid is
54. 71 cms. Minimum door width of a single door in a door way. Point transformed or converted into vapor.
55. 71 cms. Minimum width of an aisle in a store for mercantile 75. Business Under what classification of occupancy does
occupancies. court houses fall.
56. 76 Minimum height required for a panic hardware 76. Business Libraries are classified under what
cms. installation. classification of occupancy.
57. 76 Minimum width of an aisle serving an occupant of 77. Class A Class of fire involving ordinary combustible
cms. below 60 for a public assembly building. materials, such as wood, papers, cloth, rubber,
58. 76 Minimum width of Class 'B' ramp. and plastics.
cms. 78. Class B A class of fire with flammable liquid and
59. 86.5 Maximum height of a handrail. gasses.
cms. 79. Class D Class of fire involving combustible metals,
60. 91 cms. Minimum width of an aisle serving an occupant of such as magnesium, sodium, potassium, and
60 or more serving one side for a public assembly other similar materials.
building. 80. Cryogenic Any material which by its nature or as a result
61. 91 cms. Minimum stair width for a class B stair serving an of its reaction with other elements produces a
occupant load of less than 50. rapid drop in temperature of the immediate
surrounding.
62. 91 cms. Minimum width of stair for Class 'B' stairs serving 50
persons and below. 81. Dip Tank A tank, vat or container of flammable or
combustible liquid in which articles or
63. 112 Maximum height required for a panic hardware
materials are immersed for the purpose of
cms. installation.
coating, finishing, treating or similar processes.
64. 112 Minimum width of an aisle for business use structure.
82. Distillation The process of first raising the temperature to
cms.
separate the more volatile from the less
65. 112 Minimum width of an aisle for an industrial building. volatile parts and then cooling and
cms. condensing the result vapor so as to produce
66. 112 Minimum width of Class 'A' ramp. a nearly purified substance.
cms. 83. Duct A continuous passageway for the transmission
67. 112 Minimum width of landings in direction of travel for System of air.
cms. Class 'A / B' stairs.
84. Dust A finely powdered substance which, when mixed with air in the proper proportion and ignited will cause an
explosion.
85. Explosive Buildings or structures used for the storage of explosives, shells, projectile, etc.
magazine
86. Fire resistance The time duration that a material or construction can withstand the effect of standard fire test is known as.
rating
87. Flash Point The minimum temperature at which any material gives off vapor in sufficient concentration to form an ignitable
mixture with air.
88. Forging A process where a piece of metal is heated prior to changing its shape and dimension.
89. Fulminate A kind of stable explosive compound which explodes by percussion.
90. Fumigant A gas, fume or vapor used for the destruction or control of insects, fungi, vermin, germs, rodents or other
pests.
91. High rise building Buildings or structures 15 meters or more in height.
92. Industrial Under what classification of occupancy does refineries fall.
93. Institutional Under what classification of occupancy does home for the aged fall.
94. Institutional Jails are classified under what classification of occupancy.
95. Mercantile Under what classification of occupancy does drugstores fall.
96. No limit Maximum height between landings for Class 'A' ramp.
97. Oxidizing material A material that readily yields oxygen in quantities sufficient to stimulate or support combustion.
98. Phyrophoric Descriptive of any substance that ignites spontaneously when exposed to air.
99. Picking rooms. Rooms where baled, bundled or piled materials segregated into desired sizes or groups.
100. Plenum An air compartment or chamber to which 1 or more ducts are connected and which form part of an air
distribution system.