You are on page 1of 2

[Assimilation Alex] Codes (0901-1000)

Study online at quizlet.com/_2bwj6u

1. 0.83 In standard seating, the minimum spacing from 29. 30.5 cms. Maximum spacing of rungs for a fire escape
mtr. back to back. ladder.
2. (1:8) Maximum slope for aisles for public assembly 30. 30 cms. Minimum space from the back of chair to the
12.5% structures. front of the chair behind.
3. 1.8 sqm. Occupant load per person for classrooms. 31. 36 sqm minimum lot area- semi detached rowhouse
4. 1.20 m minimum size of passageway or street 32. 43 li. potable water supply per capita per day
5. 1.22 Maximum width of a single door in a doorway. 33. 50% interior lot
mts.
34. 54 sqm minimum lot area- semi detached corner lot
6. 1.80 m minimum ceiling heights of mezzanine
35. 55 cms. Minimum dimension of a rescue window for
7. 1.83 Minimum width of corridors, aisles, and ramps for educational occupancies.
mts. exits in residential-custodial care.
36. 60 oC Class III combustible liquids shall mean any
8. 2.00 m minimum horiizontal dimension of courts liquid having a flash point at how many degrees
Celsius?
9. 2.00 m minimum ceiling heights
37. 63.5 mm. Size of standpipe provided for each stage for
10. 2.44 Minimum width of corridors, aisles, and ramps for
public assembly building.
mts. exits in hospitals and nursing homes.
38. 72 sqm minimum lot area- single detached
11. 2 height limitation
STOREY 39. 75 li if independent from the developer
12. 3 Minimum number of stories of apartment buildings 40. 76.25 mts. Where exterior corridors or balconies are
requiring fire alarm system. provided as means of exit, they shall open to
the outside and shall be spaced ___ meters apart.
13. 3.5 m minimum lot frontage- semi detached rowhouse
(Educational)
14. 3.50% REQUIRED AREA FOR PARKS 150 HECTARES
41. 82 cms. Maximum height from the floor for a rescue
BELOW
window for educational occupancies.
15. 5% 3 sides public open space
42. 100 m maximum block length provided by pathwalk
16. 5.00 Minimum distance of an incinerator containing
43. 100 sqm minimum size of pocket parks
mts. kindled fire or rubbish fire or bonfires.
44. 150 m maximum block length provided by an alley
17. 6m minimum lot frontage- semi detached corner lot
45. 250 m maximum block length
18. 7% REQUIRED AREA FOR PARKS 151 - 225 HECTARES
BELOW 46. 250 up to provide an alley
400 m
19. 8m minimum lot frontage- single detached
47. 465 sqm. Any room for sleeping in institutional
20. 9% REQUIRED AREA FOR PARKS 225 HECTARES
occupancies if subdivided shall have a maximum
ABOVE
area of how many square meters?
21. 10% corner/through lots
48. Apartment Includes buildings containing three or more
22. 12 Minimum number of apartment units requiring fire Buildings living units independent cooking and bathroom
alarm system. facilities, whether or by any other
23. 20% inside lot name.designed as rowhouse, apartment house,
tenement, garden apartment,
24. 20 sqm floor area requirement for single family dwelling
unit 49. Assembly Under what classification of occupancy does
museums fall?
25. 22.9 Minimum tread for a fire escape stair for existing
cms. stairs. 50. BLASTING set offs explosives
AGENT
26. 25 cms. Minimum spacing of rungs for a fire escape ladder.
51. BP 220 Economic and Socialized Housing
27. 25 mts. far away from pollution or source of contamination
52. BP 344 Accessibility Law
28. 30% minimum open space requirement from density 60-
100 53. Business Under what classification of occupancy does
town halls fall?
54. CELLULOSE explosive compound produced by the 79. PYROPHORIC descriptive of any substance that ignites
NITRATE reaction of nitric acid w/ cellulose material spontaneously when exposed to air
55. COMBUSTIBLE flash point above 37.8 C or 100 F 80. PYROXYLIN plastic substance having cellulose nitrate as
LIQUID base
56. CORROSIVE liquid causes fire when contact with organic 81. RA 0386 An Act to Ordain and Institute the Civil
LIQUID matter Code of the Philippines
57. CRYOGENIC produces a rapid drop of temperature in 82. RA 0544 An Act to Regulate the Practice of Civil
immediate surroundings Engineering in the Phils.
58. DAMPER in air duct system; device to restrict the 83. RA 0545 An Act to Regulate the Practice of
passage of smoke or fire Architecture in RP
59. DISTILLATION first raising the temperature to separate the 84. RA 1364 Sanitary Engineering Law
more volatile from the less
85. RA 1378 An Act To Regulate the Trade Of Master
60. ELECTRIC extremely hot luminous bridge of an electric Plumber
ARC current
86. RA 1582 Ammended Civil Engineering Law
61. EMBER a hot piece or lump after a material is
87. RA 4566 Contractor's License Law
burned
88. RA 4726 Condominium Act
62. FIRE active principle of burning
89. RA 6541 Predecessor of PD 1096 (NBC)
63. FLASH POINT minimum temperature at which materials
give off vapor to form ignitable mixture with 90. RA 7277 Magna Carta for Disabled Persons
air 91. RA 7279 Urban Development Housing Act of 1992
64. FORGING a piece of metal is heated prior to changing 92. RA 8293 Intellectural Property Code of the
its shapes or dimensions Philippines
65. FULMINATE stable explosive compounds which 93. RA 8534 Interior Design Law
explodes by percussion
94. RA 8981 PRC Modernization Act of 2000
66. Hotel Includes buildings or groups of building
95. RA 9053 Philippines Landscape Architecture Act of
under the same management in which there
2000
are more than 15 sleeping accommodations
for hire. 96. RA 9266 The Architecture Act of 2004 (January 2004)
67. HYPERGOLIC a rocket or liquid propellant when fuels and 97. REFINING impurities or deleterious material remove
FUEL oxiders combined from a mixture to produce pure element
68. Means of A continuous and unobstructed route of exit 98. SLOPE not necessary in suitability of site of
Egress from any point in a building to a public way. economic socialized housing
69. OXIDIZING materials that readily yields oxygen in 99. SMELTING melting or fusing of metallic ores to
MATERIAL quantities sufficient to support combustion separate impurities from pure metals
70. PD 0223 Professional Regulation Commission (June 100. TYPE OF difference between developed and
1973) PAVEMENT undeveloped area on circulation

71. PD 0957 Regulating the sale of Subdivision Lots and


Condominiums
72. PD 1096 National Building Code
73. PD 1151 Philippine Environmental Policy (June 1977)
74. PD 1185 Fire Code of the Philippines
75. PD 1216 Defining Open Spaces in Residential
Subdivisions
76. PD 1308 Regulating the Practice of Environmental
Planning
77. PD 1594 Government Infrastructure Contracts
78. PD 1616 Architectural Guidelines for Intramuros