Professional Documents
Culture Documents
TECHNICAL DATA
Operating range: from 0.5 to 3,6 m3/h with head up to 6 metres.
Pumped liquid temperature range: from -10°C to +110°C.
Pumped liquid: clean, free from solids and mineral oils, non viscous,
chemically neutral, close to the characteristics of water (max 30% glycol).
Maximum operating pressure: 10 bar (1000 kPa).
Minimum suction pressure: the values are given in the relative tables.
VA
Installation: with HORIZONTAL MOTOR SHAFT on discharge or return pipe,
with suction port as close as possible to expansion vessel, above maximum
boiler level and as far as possible from bends, elbows, and circuit branches
to avoid water turbulence with consequent noise.
VB Protection level: corresponding to IP 44
Insulation class: F
Cable grommet: PG 11
Special executions on requests: alternative voltages and/or frequencies.
Optional accessories: r3/4”F - 1”F - 11/4”F - 11/4”M unions
VD
DN20-DN25-DN32 oval counter-flanges
DN32/PN6 round counter-flanges
CONSTRUCTION FEATURES
Enbloc body composed of hydraulic section in cast iron and wet rotor motor. Motor casing in die cast aluminium. Impeller in technopolymer. Motor shaft in
hardened stainless steel held in graphite bearings lubricated by the pumping medium.
Rotor protective jacket, stator jacket, and closing flange in stainless steel.
Ceramic thrust ring, ethylene-propylene seal rings and brass air breather plug. The two-pole asynchronous wet-rotor motor is resistance protected and does not
require any form of overload protection.
Three-speed operation.
Protection rating: IP 44
Insulation class: F
Cable gland: PG 11
Installation: with horizontal motor shaft.
Standard voltage input: single-phase 230 V / 50 Hz
Special versions on request - alternative voltages and/or frequencies
105
VA / VB / VD
WET ROTOR CIRCULATORS
MATERIALS
9 100
N. PARTS MATERIALS
8
1 PUMP BODY CAST IRON
130 128
4 IMPELLER TECHNOPOLYMER 127
132
7A MOTOR SHAFT STAINLESS STEEL 7A
7B ROTOR – 4 10
8 STATOR –
1
9 CAPACITOR – VA
VD
– Legend: VA 55 / 180 X
(example)
VA = single circulator
VB = circulator with
DN 25 oval flanges
VD = twin circulator
106
VA / VB / VD
WET ROTOR CIRCULATORS
PERFORMANCE RANGE
The performance curves are based on kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
150
15 50
40
100
10
90
9 30
BMH
80
70
7
60
6 20
50
5
40
4
DMH
30 DPH
3 10
VA - VB - VD
20 2
VS 5
10 1
0,1 0,2 0,3 0,4 0,5 0,8 1 2 3 4 5 6 7 8 10 20 30 40 50 60 80 100 200 Q m3/h
0,1 0,5 1 2 3 4 5 10 20 30 Q l/s
2 3 4 5 10 20 30 40 50 100 200 300 400 500 1000 2000 3000 Q l/min
107
VA / VB / VD
WET ROTOR CIRCULATORS
H
VA 55/130 (m) 5,4 4,7 4,5 3,3 2,6 1,75 0,85
H
VB 55/120 (m) 5,4 4,7 4 3,3 2,5 1,75 0,85
108
VA 25/130 - HEATING AND AIR CONDITIONING SYSTEMS
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 2 4 6 8 10 12 14 Q US gpm
0 2 4 6 8 10 12 Q IMP gpm
H1
P kPa Hm H Ft
H
25
2.5 8
H2
20
2.0
6
B
B2 B1 15 1.5
4
10 1.0
2
5 0.5
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 Q m3 /h
L2
0 10 20 30 40 50 Q l/min
VA 25/130 130 93 59 102,5 76,5 26 125,5 75 50,5 48 135 135 150 0,0027 2,5
0 2 4 6 8 10 12 14 Q US gpm
0 2 4 6 8 10 12 Q IMP gpm
H1
P kPa Hm H Ft
H
25
2.5 8
H2
20
2.0
6
B
B2 B1
15 1.5
4
10 1.0
2
5 0.5
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 Q m3 /h
L2
0 10 20 30 40 50 Q l/min
F
The performance curves are based on kinematic viscosity values =
1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
VA 25/180 180 93 59 102,5 76,5 26 125,5 75 50,5 48 130 190 150 0,0037 2,6
109
VA 25/180X - HEATING AND AIR CONDITIONING SYSTEMS
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 2 4 6 8 10 12 14 Q US gpm
0 2 4 6 8 10 12 Q IMP gpm
H1
P kPa Hm H Ft
H
25
2.5 8
H2
20
2.0
6
B
B2 B1
15 1.5
4
10 1.0
2
5 0.5
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 Q m3 /h
L2
VA 25/180X 180 93 59 102,5 76,5 26 125,5 75 50,5 48 130 190 150 0,0037 2,6
0 2 4 6 8 10 12 14 Q US gpm
0 2 4 6 8 10 12 Q IMP gpm
H1
P kPa Hm H Ft
45
H
4.5
14
40
4.0
H2
35 12
3.5
30 10
3.0
B
B2 B1 25 2.5 8
20 2.0
6
15 1.5
4
10 1.0
5 2
0.5
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 Q m3 /h
L2
VA 35/130 130 93 59 102,5 76,5 26 125,5 75 50,5 48 135 135 150 0,0027 2,5
110
VA 35/130 - 1/2” - HEATING AND AIR CONDITIONING SYSTEMS
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 2 4 6 8 10 12 14 Q US gpm
0 2 4 6 8 10 12 Q IMP gpm
H1
P kPa Hm H Ft
45
H
4.5
14
40
4.0
H2
35 12
3.5
30 10
3.0
B
B2 B1 25 2.5 8
20 2.0
6
15 1.5
4
10 1.0
5 2
0.5
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 Q m3 /h
L2
VA 35/130 - 1/2” 180 93 59 102,5 76,5 26 125,5 75 50,5 48 135 135 150 0,0027 2,5
0 2 4 6 8 10 12 14 Q US gpm
0 2 4 6 8 10 12 Q IMP gpm
H1
P kPa Hm H Ft
45
H
4.5
14
40
4.0
H2
35 12
3.5
30 10
3.0
B
B2 B1 25 2.5 8
20 2.0
6
15 1.5
4
10 1.0
5 2
0.5
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 Q m3 /h
L2
VA 35/180 180 93 59 102,5 76,5 26 125,5 75 50,5 48 130 190 150 0,0037 2,6
111
VA 35/180X - HEATING AND AIR CONDITIONING SYSTEMS
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 2 4 6 8 10 12 14 Q US gpm
0 2 4 6 8 10 12 Q IMP gpm
H1
P kPa Hm H Ft
45
H
4.5
14
40
4.0
H2
35 12
3.5
30 10
3.0
B
B2 B1 25 2.5 8
20 2.0
6
15 1.5
4
10 1.0
5 2
0.5
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 Q m3 /h
L2
VA 35/180X 180 93 59 102,5 76,5 26 125,5 75 50,5 48 130 190 150 0,0037 2,6
0 2 4 6 8 10 12 14 16 Q US gpm
0 2 4 6 8 10 12 14 Q IMP gpm
H1
P kPa Hm H Ft
55
5.5
H
18
50
5.0
16
45
H2
4.5
14
40 4.0
35 12
B 3.5
B2 B1 30 3.0 10
25 2.5 8
20 2.0
6
15 1.5
4
10 1.0
5 0.5 2
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q m3 /h
L2
0 10 20 30 40 50 60 Q l/min
VA 55/130 130 93 59 102,5 76,5 26 125,5 75 50,5 48 135 135 150 0,0027 2,5
112
VA 55/130 - 1/2” - HEATING AND AIR CONDITIONING SYSTEMS
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 2 4 6 8 10 12 14 16 Q US gpm
0 2 4 6 8 10 12 14 Q IMP gpm
H1
P kPa Hm H Ft
55
5.5 18
H
50
5.0
16
45
H2
4.5
14
40 4.0
35 12
B 3.5
B2 B1 30 10
3.0
25 2.5 8
20 2.0
6
15 1.5
4
10 1.0
5 0.5 2
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q m3 /h
L2
VA 55/130 - 1/2” 130 93 59 102,5 76,5 26 125,5 75 50,5 48 135 135 150 0,0027 2,5
0 2 4 6 8 10 12 14 16 Q US gpm
0 2 4 6 8 10 12 14 Q IMP gpm
H1
P kPa Hm H Ft
55
H
5.5 18
50
5.0 16
45
H2
4.5
14
40 4.0
35 12
B 3.5
B2 B1 30 3.0 10
25 2.5 8
20 2.0
6
15 1.5
4
10 1.0
2
5 0.5
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q m3 /h
L2
VA 55/180 180 93 59 102,5 76,5 26 125,5 75 50,5 48 130 190 150 0,0037 2,6
113
VA 55/180X - HEATING AND AIR CONDITIONING SYSTEMS
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 2 4 6 8 10 12 14 16 Q US gpm
0 2 4 6 8 10 12 14 Q IMP gpm
H1
P kPa Hm H Ft
55
H
5.5 18
50
5.0 16
45
H2
4.5
14
40 4.0
35 12
B 3.5
B2 B1 30 3.0 10
25 2.5 8
20 2.0
6
15 1.5
4
10 1.0
5 0.5 2
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q m3 /h
L2
0 10 20 30 40 50 60 Q l/min
VA 55/180X 180 93 59 102,5 76,5 26 125,5 75 50,5 48 130 190 150 0,0037 2,6
0 2 4 6 8 10 12 14 16 Q US gpm
0 2 4 6 8 10 12 14 Q IMP gpm
H1
P kPa Hm H Ft
60 20
6.0
H
55
5.5 18
50
5.0
H2
16
45
4.5
40 14
4.0
B 35 12
B2 B1 3.5
30 3.0 10
25 2.5 8
20 2.0
6
15 1.5
4
10 1.0
5 0.5 2
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q m3 /h
L2
0 10 20 30 40 50 60 Q l/min
VA 65/130 130 93 59 102,5 76,5 26 125,5 75 50,5 48 135 135 150 0,0027 2,5
114
VA 65/130 - 1/2” - HEATING AND AIR CONDITIONING SYSTEMS
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 2 4 6 8 10 12 14 16 Q US gpm
0 2 4 6 8 10 12 14 Q IMP gpm
H1
P kPa Hm H Ft
60 20
6.0
H
55
5.5 18
50
5.0
H2
16
45
4.5
40 14
4.0
B 35 12
B2 B1 3.5
30 3.0 10
25 2.5 8
20 2.0
6
15 1.5
4
10 1.0
2
L1
5 0.5
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q m3 /h
L2
0 10 20 30 40 50 60 Q l/min
VA 65/130 - 1/2” 130 93 59 102,5 76,5 26 125,5 75 50,5 48 135 135 150 0,0027 2,5
0 2 4 6 8 10 12 14 16 Q US gpm
0 2 4 6 8 10 12 14 Q IMP gpm
H1
P kPa Hm H Ft
60 20
6.0
H
55
5.5 18
50
5.0
H2
16
45
4.5
40 14
4.0
B 35 12
B2 B1 3.5
30 3.0 10
25 2.5 8
20 2.0
6
15 1.5
4
10 1.0
5 0.5 2
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q m3 /h
L2
0 10 20 30 40 50 60 Q l/min
VA 65/180 180 93 59 102,5 76,5 26 125,5 75 50,5 48 130 190 150 0,0037 2,6
115
VA 65/180X - HEATING AND AIR CONDITIONING SYSTEMS
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 2 4 6 8 10 12 14 16 Q US gpm
0 2 4 6 8 10 12 14 Q IMP gpm
H1
P kPa Hm H Ft
60 20
H
6.0
55
5.5 18
50
H2
5.0
16
45
4.5
40 14
4.0
B 12
B2 B1 35
3.5
30 3.0 10
25 2.5 8
20 2.0
6
15 1.5
4
10 1.0
2
L1
5 0.5
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q m3 /h
L2
0 10 20 30 40 50 60 Q l/min
1 880 37 0,17
VA 65/180X 130 93 59 102,5 76,5 26 125,5 75 50,5 48 130 190 150 0,0037 2,6
D
H
0 2 4 6 8 10 12 14 Q US gpm
0 2 4 6 8 10 12 Q IMP gpm
H
P kPa Hm H Ft
H
D2
I
25
D2
H2
2.5 8
I
H2
20
2.0
6
15 1.5
B
B2 B1 4
B 10 1.0
B2 B1
2
5 0.5
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 Q m3 /h
0 0.2 0.4 0.6 0.8 Q l/sec
L1
L
L2
0 10 20 30 40 50 Q l/min
L2
VB 35/120 120 98 60 104 78 26 124 75 49 25 M10 78 135 135 150 0,0027 2,7
116
VB 55/120 - HEATING AND AIR CONDITIONING SYSTEMS
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
D
H
0 2 4 6 8 10 12 14 16 Q US gpm
0 2 4 6 8 10 12 14 Q IMP gpm
H
P kPa Hm H Ft
H
D2
55
5.5 18
I
H
50
D2
5.0
H2
16
I
45
4.5
14
H2
40 4.0
35 12
3.5
30 3.0 10
B 25 2.5
B2 B1 8
20
B 2.0
6
B2 B1 15 1.5
4
10 1.0
5 0.5 2
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q m3 /h
0 0.2 0.4 0.6 0.8 1.0 Q l/sec
L1
L
L2
0 10 20 30 40 50 60 Q l/min
L2
VB 55/120 120 98 60 104 78 26 124 75 49 25 M10 80 135 135 150 0,0027 2,7
D
H
0 2 4 6 8 10 12 14 16 Q US gpm
0 2 4 6 8 10 12 14 Q IMP gpm
H
P kPa Hm H Ft
H
D2
55
5.5 18
I
50
D2
5.0
H2
16
I
45
4.5
14
H2
40 4.0
35 12
3.5
30 3.0 10
B 25
B2 B1 2.5 8
B 20 2.0
6
B2 B1 15 1.5
4
10 1.0
5 0.5 2
L1
L
0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q m3 /h
0 0.2 0.4 0.6 0.8 1.0 Q l/sec
L1
L
L2
0 10 20 30 40 50 60 Q l/min
L2
117
VD 55/220.32 - HEATING AND AIR CONDITIONING SYSTEMS
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 2 4 6 8 10 12 14 16 Q US gpm
H
H1 H2 H
D H1 H2
0 2 4 6 8 10 12 14 Q IMP gpm
D2 D
D2
P kPa Hm H Ft
55
5.5 18
D5
50
5.0
16
L2
45
4.5
14
D1
D4
40 4.0
L
35 12
3.5
30 3.0 10
L1
25 2.5 8
B1 B2 20
B 2.0
6
D1
D4 15 1.5
D5
D1
D4 4
D5
10 1.0
B1
5 0.5 2
B1
0 0 0
B
B2
0 10 20 30 40 50 60 Q l/min
L1
L
L2 L
The performance curves are based on kinematic viscosity values =
L1 L2
1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
VD 55/220.32 270 91,5 128,5 150 50 100 140 90 100 70 32 14 18 230 115 115 160 253 238 0,0096 8,2
0 2 4 6 8 10 12 14 16 Q US gpm
H
H1 H2 H
D 0 2 4 6 8 10 12 14 Q IMP gpm
H1 H2
D2 D P kPa Hm H Ft
D2
55
5.5 18
D5
50
5.0
16
L2
45
4.5
14
D1
D4
40 4.0
L
35 12
3.5
30 3.0 10
L1
25 2.5 8
B1 B2 20 2.0
B 6
D1 15
D4 1.5
D5
D1
D4 4
D5
10 1.0
B1
5 0.5 2
B1
0 0 0
B
B2
0 10 20 30 40 50 60 Q l/min
L1
L
L2 L
The performance curves are based on kinematic viscosity values =
L1 L2 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
VD 65/220.32 220 91,5 128,5 150 50 100 140 90 100 70 31 14 18 230 115 115 160 253 238 0,0096 8,2
118