VS + VSI
GEAR FLOW METERS
2 VS POSITIVE DISPLACEMENT FLOW METERS
One impulse 3
3 Impulse
impulsesproper
durchgesetzte
volume (10Flüssigkeitsmenge
cm3 ) (10 cm3)
um eine tooth
of one Teilungpitch
Volume / impulse in cm3 / Imp
Volume / impulse in cm3 / Imp
Messvolumen/Impuls in cm3/Imp
(10/3 cm =Vm)
3
Kanal 1
Channel 1 Channel 1
Upp
Upp
Channel offset by 1/4 Channel offset
Kanalversatz by 1/4 of
um eine
of tooth pitch (90°) tooth pitch (90°)
1/4 Teilung (90°)
Channel 2 Kanal22
Channel
BLOCK DIAGRAM
+ Volts
brown
Channel 1
white
0 Volts
Processor unit
blue
Channel 2
black
Cylinder speed and position measurement Control and regulation of single components, mixing
ratios and consumption of various components
Positioning and step control
Leakage measurement and leakage monitoring on
Measurement, control and regulation of flow rates plants
and volumes
Measurement, indication and logging of data for pro-
Test stands for pumps, motors, valves, proportionals duct quality assurance
and servo-valves
Synchronised multi-cylinder monitoring Special designs on request
Filling and additive blending
TECHNICAL DATA
For precise and exact flow and volume measurements, This individually programmed high resolution enables
it is necessary to increase the resolution as high as you to set the volume measurement Vm optimally for
possible by resolving the measurement Vm, even more each provided case of application. Furthermore, new
than with conventional preamplifiers. applications can be availed with the higher resolution
With the VSI-preamplifier versions a selectable • Measuring, controlling and regulating in lower flow
resolution of up to 128 flanks (32 pulses) per period ranges
can be attained (see table below). • Measuring, controlling and regulating in zero flow
• Measuring, controlling and regulating in both flow
This means that you can resolve the volume directions
measurement Vm with this preamplifier to a maximum • Measuring, controlling, dosing and filling of small
of 1/128 Vm. volumes
ADVANTAGES
Easy replaceable, Upgrade for standard VS, higher
resolution, more stability under harsh conditions
10 INTERPOLATION FACTOR AND RESOLUTION
Column 1: Programmable interpolation factor IPF In practice the maximum flow Qmax of the flow meter is
(programming is done in the factory) seldom run so that a lower frequency can be calculated.
Column 2: Pulses per volume measurement Vm The maximum frequency is then calculated according
Column 3: Maximum resolution of the signal flanks. The to the following formula:
signal flanks channels 1 and 2 are evaluated
Column 4: Volume measurement Vm* resulting from the (Qmax)*IPF
fmax*= formula 1
maximum resolution of the signal flanks Vm
Column 5: Maximum resolution in angle degrees at
resolution of signal flanks
Column 6: Maximum frequency fmax* at maximum flow fmax* Maximum frequency of the flow meter
Qmax and programmed interpolation factor IPF signals
Qmax Maximum flow attained in the case of
application described here
IPF Programmed interpolation factor
V Volume measurement of the flow meter
m
Flow resistance ∆ p
Flow rate Q Flow rate Q
VS(I) 0.1 VS(I) 0.2
Flow resistance ∆ p
Flow resistance ∆ p
Flow resistance ∆ p
VS(I) 2 VS(I) 4
Flow resistance ∆ p
Flow resistance ∆ p
VS(I) 10
Flow resistance ∆ p
Flow rate Q
VS(I) FLOW METER DIMENSIONS 13
VS(I) 0.02 … VS(I) 4
to and
to and
CAST IRON VERSION CAST IRON VERSION
Housing curve mill cutted CONNECTION DRAWING
Grounding View X
O-Ring
Centre bores
Weight
Size
A B C D E øG H K L M N O-Ring GG* E**
VS / VSI
kg kg
0.02 100 80 91 M6 12 ø9 114 58 70 40 20 11 x2 2.8 3.4
0.04 100 80 91.5 M 6 11.5 ø9 114.5 58.5 70 40 20 11 x2 2.8 3.4
0.1 100 80 94 M6 9 ø9 117 61 70 40 20 11 x2 2.8 3.4
0.2 100 80 93.5 M 6 9.5 ø9 116.5 60.5 70 40 20 11 x2 3.0 3.7
0.4 115 90 96.5 M 8 11.5 ø 16 119.5 63.5 80 38 34 17.96 x 2.62 4.0 5.0
1 130 100 101 M8 12 ø 16 124 68 84 72 34 17.96 x 2.62 5.3 6.8
2 130 100 118 M8 15 ø 16 141 85 84 72 34 17.96 x 2.62 6.7 8.4
4 180 140 143 M 12 20 ø 30 166 110 46 95 45 36.17 x 2.62 14.7 18.4
DIMENSIONS VS(I) 10
View X Connection drawing
Handle Earthing clip O-ring
Lifting eye bolt
Connection
Lifting eye bolt
drawing
Weight 70 kg
2 2 2 2
10 000 mm /s 1000 mm /s 280 mm /s 100 mm /s
15
14
2
bar 50 mm /s
14 2
SIDE PORTS
12 BOTTOM PORTS 21 mm /s
2
11 mm /s
10
8
Flow meter
Flow meter 6
Subplate 4
Subplate
2
0
0 50 100 150 200 250 300 350 400 l/min 500 525
Abmessungen
58
Ansicht X Anschlussbild
AP SUBPLATE DIMENSIONS
229
Cast iron / APG.S... /. Stainless steel / APE.S... / . Cast iron / APG.U... /. Stainless steel / APE.U... / .
125
70
29
A Ø38 A A C
C M16 XC O- Ring C
44,12 x 2,62
Bügelgriff
84
Ringschraube
64
D
D
B
D
L
L
E E
M12 x 1
230
336
64
84
G
F
Ringschraube F
M../.. for fixing the subplate M../.. for fixing the subplate G G
Die Abmessungen sind in mm angegeben
290 M../.. for fixing the subplate M../.. for fixing the subplate
* Both bottom ports (G) for size APG 4 U and APE 4 U have a displacement of 90° to the shown drawings.
Abmessungen Anschlussplatte
APG
APG10
10SG0N
S GON/ /11 APG 10 SW0N / 1
180 180
140 View X 140
180
140
View X
View X
79,4 M16 - 27
Connection M10
drawing
Connection drawing
M10 deep M16 - 27 deep
79,4
M10 VS 10
VS 10
230
170
17 0
170
230
18
18
230
18
=
80
36,5
36, 5
100
100
=
Connection
=
drawing
Connection drawing
G 1 1/2 VS 10 VS 10
Ø38
Ø 56 Weight 21 kg Connection drawing WeightWeight
26.8 26,8
kg kg
ø 38
VS / VSI 10
Dimensions are specified in mm
15
VS / VSI G F øH E 1
Evaluation unit
Isolation switching amplifier: 1. Channel
5
+ 1 1 pn p Signal (1. Channel)
+ 6
B I
- 2 1. Channel 2
3
-
pn p
+
7
Inv. signal (1. Channel)
Ub1+
powe r 8
4 - GND1 (0V; Ub1-)
MK 13- P - E x0/24V D C/ K 15
Isolation switching amplifier: 2. Channel
5
+ 4 1
+
pn p Signal (2. Channel)
B I
- 3 2. Channel 2 - pn p
6
7
Inv. signal (2. Channel)
Ub2+
3 +
powe r 8
4 - GND2 (0V; Ub2-)
MK 13- P - E x0/24V D C/ K 15
if
required
THE BARRIER AMPLIFIER An error in the control circuit stops the signal output.
MK 13-P-EX 0 / 24 VDC / K15 One pluse-switching short circuit proof transistor
The barrier amplifier MK 13-P-Ex 0/24 VDC/ output (PNP-output) provides the digital signal of the
K15 enables an isolated transmission of binary connected channel.
Temperature class T4 T5 T6
Ambient temperature - 20°C ≤ Tamb ≤ 95°C - 20°C ≤ Tamb ≤ 70°C - 20°C ≤ Tamb ≤ 55°C
Liquid temperature - 20°C ≤ TMed ≤ 100°C - 20°C ≤ TMed ≤ 75°C - 20°C ≤ TMed ≤ 60°C
PICK-UP SYSTEM FOR HIGH TEMPERATURE RANGES 17
CONNECTION DIAGRAMS
1
+U
2
OUT
3
0V
1 1
+U +U
RL
2 2
442R
Ω 442RΩ
RL
3 3
0V 0V
Centre bores
Cable length 1m
O-Ring
Weight
Size A D E øG K L M N P O-Ring
kg
VS 0.04* 100 M6 11.5 ø 9 58.5 70 40 20 22 11 x2 3.5
VS 0.1 100 M6 9 ø 9 61 70 40 20 22 11 x2 3.3
VS 0.2 100 M6 9.5 ø 9 60.5 70 40 20 22 11 x2 3.6
VS 0.4 115 M8 11.5 ø 16 63.5 80 38 34 22 17.96 x 2.62 4.9
VS 1 130 M8 12 ø 16 68 84 72 34 22 17.96 x 2.62 6.7
VS 2 130 M8 15 ø 16 85 84 72 34 22 17.96 x 2.62 8.3
VS 4 180 M 12 20 ø 30 110 46 95 45 12 36.17 x 2.62 18.3
*Attention: 0.04 with one (1) channel only
TYPE KEY 19
TYPE KEY FLOW METERS VS H T Pick-up system for high temperature ranges (...210°C) signal output PNP or NPN
EXAMPLE
- H T / X
VS 1 G P 0 1 2 V - 3 2 N 1 1 / X
Connection
Series
Pre-amplifier
X No. factory preset
Factory preset to the application
0 Non pre-amplifier
1 Integrated
2 External
Factory preset to the application
Pick-up system
1 1 pick-up
2 2 pick-up
3 GMR- Sensor
Instrument tolerance
S Silicone
Reduced tolerance 1
Normal tolerance (Standard) 2
3 Increased tolerance
4 Tolerance steel plain bearing
1 Ball bearing
Gear coating
2 Spindle bearing
3 Bronze plain bearing
Type of connection
P Plate construction
R Pipeline connections
G EN-GJS-400-15 (VS10 = EN-GJS-600-3) DIN EN 1563
Stainless steel 1.4305 (V2A)
Size
E
H EN-GJS-600-3 (High pressure) DIN EN 1563
VS 0.02
VS 0.04
VS 0.1
VS 0.2
VS 0.4
VS 1
VS 2
VS 4
VS 10
20 SUBPLATES AP
SUBPLATES AP
EXAMPLE
Bottom connection
TYPE KEY 21
EXAMPLE
VSI 1 / 4 G P O 1 2 V - 3 2 W 1 5 / X . .
voltage
supply
Product line
Power
Connection
Factory preset to the application
10 ... 28 V Power supply volt.
Pre-amplifier
X Modification id. No.
Factory preset to the application
Signal output
1 VSE norm connection (4-pole)
2 2 Sensors
3 GMR- Sensor
Instrument tolerance
B EPDM - 41B8
S Silicone
Measuring wheel coating
1 Reduced tolerance
2 Normal tolerance (standard)
3 Increased tolerance
4 Tolerance steel plain bearing
Ball bearings 1
Type of connection
Spindle bearings 2
Bronze plain bearings
3
Carbon bearings 4
Steel bearings 5
O No coating (standard)
C Dynamat coating (C-coating)
Material
T Titanium coating
P Plate construction
Interpolation
R Pipeline connections
G EN-GJS-400-15 (VSI10 = EN-GJS-600-3) DIN EN 1563
E Stainless steel 1.4305 (V2A)
H EN-GJS-600-3 (High pressure) DIN EN 1563
1 1 Imp. pro Vz Vm = Vz pro Imp 1 3 Imp. pro Vz Vm = 10/ 3 pro Imp
2 2 Imp. pro Vz Vm = Vz / 2 pro Imp. 2 6 Imp. pro Vz Vm = 10/ 6 pro Imp.
for VSI 0.02 to VSI 4
12 12 Imp. pro Vz Vm = Vz /12 pro Imp. 12 36 Imp. pro Vz Vm = 10/36 pro Imp.
16 16 Imp. pro Vz Vm = Vz /16 pro Imp. 16 48 Imp. pro Vz Vm = 10/48 pro Imp.
Flow direction indication with switching output Flow rate, volume and ratio measurements as well as
(0 V/5 V) measurement and control of volume-shots or mass-shots
2 optocoupler limit value outputs, limit values are in 2-component mixing systems
individually programmable Signal processing of 2 flow sensors with 2-channel
Analogue output with flow rate direction dependent signal outputs
voltage-/current-polarity is available 2 independent dynamic analogue outputs with 16 Bit
0 … (±) 10 V digital-analogue converter D/A-converter:
0 … (±) 20 mA
< 3 ms (0 Hz 2 kHz 0 Hz)
4… 20 mA
A power supply for flow sensor is integrated The flow rate and volume values are direction dependent
24 Volt DC /50 mA
Flow in direction 1
(0 V Flow in direction 2 5 V 10 V)
or direction independent
Flow in direction 2 Flow in direction 1
(10 V 0 V 10 V)
The evaluation electronics A341-28 simultaneously The A350-28 is a multifunctional device for flow and
records two independent flows via flow meters and is volume measurement.
suitable for incremental rotary transducers, proximity Universal inputs (HTL/RS422) for encoders / VSE
switches, etc. flow meters
Two individually scalable pulse inputs for 1, 2 or 4 186 x 64 pixel graphic display with touch function
tracks (A, /A, B, /B), suitable for input frequencies of
Bright, high-contrast display with result-based colour
0.01 Hz to 1 MHz per channel
options
Single measurement, sum or differential measurement,
Emulation of a 7-segment display with symbols
ratio or percentage deviation, etc.
and units
Linearisation function for each flow measurement
Intuitive and easy parameterisation using plain text
5 independent parameter sets presettable and touchscreen or via a RS232 interface
14-bit analogue output; 0/4 ... 20 mA, 0 ... 10 V and Auxiliary voltage output 5/24 VDC for encoder supply
-/+ 10 V; <1 ms reaction time
Input frequency up to 1 MHz
4 limit value settings with very fast responding
Linearisation with 24 support points
transistor switch outputs
16 bit analog output 0/4 ... 20 mA, 0 ... 10 V and
Programmable via an RS232 interface
-/+ 10 V; 20 ms reaction time
2x encoder supply 24 VDC/120 mA
Numerous functions such as scaling, filters, startup
Standard housing 96 x 48 mm and protection class bridging
IP65
Standard installation housing with 96 x 48 mm and
protection class IP65
24 ELECTRONIC EVALUATION UNITS
Converter output signal for operation with 1-channel For example: for chart recorder with impulse input, for-
flow sensor ward-/reversecounter, computer, PC- and PLC controls
0 ... 10 V Available output voltages:
0 ... 20 mA TTL 5 V, 8 V, 12 V, CMOS 15 V
4 ... 20 mA
Power supply/current consumption:
Converter output signal with flow direction polarity for 10 ... 30 V DC, 20 mA without flow sensor
operation with 2-channel flow sensor
Inverted and non-inverted output signal for both chan-
0 ... ± 10 V
nels integrated among other things for connection on
0 ... ± 20 mA
differential count inputs to achieve a distortion-free
Evaluation of flow direction via digital output signal signal transmission over long cable distances
possible if a 2-channel flow sensor is connected
Proportional to flow frequency a digital output
frequency signal with multiplier factor is adjustable