TEST CERTIFICATE FOR POLYETHYLENE MATERIALS FOR MOULDING AND EXTRUSION

Certificate No. : 6455 Date : 30.01.2024 Consignee Name & Address:


Truck No. : WB831517 Type : HDPE MANAK POLYMERS PVT LTD
Grade Name : HALENE H B6401 BIS Code : IS 7328-3P-BB-GXDA IID CENTRE-RANGIA,VILL
Batch Number : 2472010136 Lot Size : 130 MT BORSIL-SOTSI, RANGIA,
KAMRUP, 781354,
Assam, India

CHARACTERISTIC METHOD UNIT NOMINAL VALUE


MELT FLOW RATE @ 2.16 kg, 190°C IS 13360 / ASTM D1238 g/10 min 0.45
DENSITY @ 23°C (MITSUI) IS 13360 / ASTM D1505 g/cm3 0.963
* MFI test procedure as per ASTM D1238 and IS13360 (Part4/Sec.1) are Technically Equivalent
* Density test procedure as per ASTM D1505 and IS13360 (Part3/Sec.11) are Technically Equivalent
* All the tests comply with the latest revisions / amendments of the respective standards.

Haldia Petrochemicals Limited states that the product fully conforms to the requirement of IS 7328:2020.
Properties of the product are tested in accordance with Scheme of Inspection and Testing contained in the BIS Certification
Marks License CM/L No. 5100208172

PLEASE REFER TO IS 7328:2020 FOR DETAILS OF SPECIFICATION REQUIREMENTS


For BIS certification details visit www.bis.gov.in

Additional Requirements: This complies with the requirements, recommendations, or communications of:

IS 10146:1982 on Specification of Polyethylene for its safe use in contact with Foodstuffs, Pharmaceuticals and
Drinking Water
IS 16738:2018 on Positive lists of constituents of Polypropylene, Polyethylene, and their Copolymers in contact with
Foodstuffs, Pharmaceuticals and Drinking Water. The total quantity of Antioxidant used in this grade is less than 0.3%.
21CFR 177.1520 of US FDA. According to our information, all additives and constituents used in the grade meets the
requirements of their respective FDA regulations and 21 CFR 177.1520

Jyotirmaya Das Basanta Kumar Patra

Checked By Sr. Manager QA

The tested value presented herein are of representative samples from the lot in accordance with BIS Scheme of Inspection and Testing. Prior to use, buyer shall ensure independently through
tests and trials, that HPL products can be handled and used by them legally, safely, and suitably for their intended operation and end-use application. No warranty or guarantee expressed or
implied is made regarding performance or otherwise. In no event shall HPL be liable for any damage, loss or injury directly or indirectly suffered as a result of use of product or information
provided herein. The information & data contained herein are reliable to the best of our knowledge on the date of release of the document and is subject to change without prior intimation based
on research & development work undertaken by HPL.