Professional Documents
Culture Documents
RR245 Stress Redistribution in Platform Substructure Due To Primary Member Damage
RR245 Stress Redistribution in Platform Substructure Due To Primary Member Damage
An investigation has been conducted to establish the damage tolerance of five different bracing
configurations that have been applied to a generic jacket structure. The investigations have provided
an insight into how the different bracing configurations are able to accommodate a fully severed
member and the impact that this has on the load distribution, ultimate strength and ultimately the
predicted structural reliability. In performing this study a total of 406 FE analyses have been carried
out.
The baseline structure was based upon a wellhead platform jacket comprising of three bays that is
currently operational and stands in approximately 45m of water in the Southern North Sea. The five
bracing configurations were each applied to this structure and the members were sized using an elastic
limit design process, using consistent slenderness ratios between corresponding members in each of
the bracing configurations.
This report and the work it describes were funded by the Health and Safety Executive (HSE). Its
contents, including any opinions and/or conclusions expressed, are those of the authors alone and do
not necessarily reflect HSE policy.
HSE BOOKS
© Crown copyright 2004
ii
CONTENTS
1.1 Background..........................................................................................................1
1.2 Scope of Work .....................................................................................................1
3.1 Background..........................................................................................................9
3.2 Results and Discussions......................................................................................9
3.3 Stress Redistribution Study Summary ...............................................................13
4.1 Background........................................................................................................15
4.2 Modifications to Single Diagonal Braced Jacket Model .....................................15
4.3 Results ...............................................................................................................15
4.4 Discussion .........................................................................................................16
4.5 Cracked Member Study Summary.....................................................................16
5.1 Background........................................................................................................19
5.2 Results and Discussions....................................................................................19
5.3 Ultimate Strength Study Summary.....................................................................21
6.1 Background........................................................................................................23
6.2 Reliability Assessment .......................................................................................23
6.3 Results ...............................................................................................................26
6.4 Discussion .........................................................................................................27
6.5 Reliability Study Summary .................................................................................28
iii
Appendix A Model Description ...........................................................................57
iv
EXECUTIVE SUMMARY
An investigation has been conducted to establish the damage tolerance of five different
bracing configurations that have been applied to a generic jacket structure. The
investigations have provided an insight into how the different bracing configurations are
able to accommodate a fully severed member and the impact that this has on the load
distribution, ultimate strength and ultimately the predicted structural reliability. In
performing this study a total of 406 FE analyses have been carried out.
The baseline structure was based upon a wellhead platform jacket comprising of three bays
that is currently operational and stands in approximately 45m of water in the Southern
North Sea. The five bracing configurations were each applied to this structure and the
members were sized using an elastic limit design process, using consistent slenderness
ratios between corresponding members in each of the bracing configurations.
x Severance of a member in one of the low redundancy structures leads to a more global
stress redistribution, with the majority of joints throughout the structure seeing an
increase in load.
x Introduction of a cracked member into a Single Diagonal braced structure had limited
effect, with only localised increases in load. Increases in load were observed in those
joint groups that the cracked member intersected. In particular an increase in load was
observed in the cracked member’s joints with the jacket legs that has been attributed to
the increased bending of the member as a result of the eccentricity of the neutral axis
local to the cracked region.
- That severance of a lower bay tensile member had the greatest consequence on
ultimate strength. This identifies these members as having a higher criticality in
the context of primary bracing integrity.
- Highly redundant structures to be highly damage tolerant.
- That the single diagonal braced structure provides a high strength structure
comparable to the X-braced but not as damage tolerant.
- That K-braced and inverted K-braced structures have the lowest ultimate strengths
with the K-brace structured being the least tolerant to damage.
- That the introduction of a second severed member into the inverted K-braced
structure resulted in a drastic reduction in its ultimate strength.
x Stress redistribution causes an acceleration in the rate of fatigue damage at
neighbouring members when damage occurs. This causes an increase in the
probability of failure of the neighbouring members and an associated increase in
overall platform collapse due to multiple-member failure. This effect has been
v
demonstrated for two multiple-member failure cases; one on the X-braced structure
and one on the inverted K braced structure.
x The reliability study showed that high redundancy structures are more reliable for two
major reasons:
- They are stronger when damaged (i.e. more damage tolerant) and hence can resist
more extreme (i.e. infrequent) storms.
- Stress redistribution effects are more limited and hence the acceleration of fatigue
damage (and associated increase in probability of failure) to neighbouring
members is less onerous.
It is considered that the work described in this report and its associated appendices
provides the first steps towards developing a reliability based performance measure for
jackets. The report has provided evidence of the types of jackets that carry the largest risk
of structural failure.
vi
1. INTRODUCTION
1.1 BACKGROUND
The purpose of this study is to build upon the work detailed in Reference 1 carried out as part
of the Joint Industry Project on the reliability of FMD as a tool for integrity assurance of steel
jackets (HSE Project N° P3513). It aims to investigate the effects of damaged members on
the load distribution within jacket structures and the associated impact on structural
reliability.
The redistribution of load following the failure of a member is dependent upon the
redundancy of the structure. For this reason five bracing configurations that were perceived
to possess varying degrees of redundancy have been considered as part of this study. These
are as follows:
x X-braced.
x Diamond braced.
x K-braced.
x Inverted K-braced
x Single diagonal braced.
These five bracing configurations were applied to a generic jacket that comprised of the
jacket’s legs, conductors, horizontal plane framing, piles and topsides, thus effectively
creating five different jackets. All dimensions and topside loads for this generic jacket were
initially taken to be those of an actual platform, located in the Southern North Sea, standing in
approximately 45 metres of water. The sizing of the bracing members was based on an
elastic design process using the methods outlined in Reference 2.
It was essential that the study considered three-dimensional effects introduced into the jacket
structures as a result of the stress redistribution. Loss of a member on one face of a platform
can induce non-planar effects such as torsion into the jacket’s structure. To reduce the
amount of analyses, each face of the jacket was designed to be symmetrical such that wave
attack directions that need to be analysed would be reduced to just one quadrant of the
compass (due to corner symmetry), i.e. North, North East and East. The size of the models,
combined with the single wave attack direction, enabled a significant number of studies to be
conducted.
1
All models were developed in ABAQUS (Reference 3).
EQE’s in-house software, developed for ABAQUS, allows normal design, and non-linear
pushover analyses to be undertaken using the same model. It also permits shell sub-models to
be introduced into the beam models to enable the introduction of through-thickness
circumferential cracks into the analyses.
2
2. MODEL DESCRIPTION
A brief description of the jacket models used in this study is provided below. A more detailed
description of the model and its development along with the applied loads and material model
used in the studies is provided in Reference 2.
2.2.1 Topsides
The topsides’ weight was based upon that of the baseline jacket that weighs 1200 tonnes, and
was represented in the generic structure as a single mass element. The location of this mass
element was 5 metres above the topsides’ stab-in points, at the geometric centre of the
jacket’s plan view. The topsides’ mass element was tied into the structure at the stab-in
points using beam type ‘multi-point constraints’ which effectively formed a rigid link
between the topsides’ mass element and the stab-in points.
2.2.2 Piles
The piles of the baseline structure were used to determine the number, type and characteristics
of the generic structure’s piles. Where the piles were sleeved an effective cross-section was
derived that provided a comparable bending restraint to that of the composite cross section.
The cross-sectional dimensions of the baseline structure’s piles were modified during the
model development phase of the work to increase their combined bending and axial load
capacity, thus promoting structural failure in the structure’s framing. The resultant cross-
sectional dimensions of the generic structure’s piles are as follows:
The effective point of fixity for the piles was assumed to be 20 m below the mud-line.
No account was taken of the additional restraint on the piles offered by the soil interaction.
This was deemed acceptable on the basis that the jacket was being developed to investigate
3
the structural behaviour of differing bracing configurations and not the failure of the
structure’s foundations during extreme storm events.
2.2.3 Legs
All four of the structure’s legs were modelled with identical cross-sectional properties
that were slightly modified from those of the baseline structure.
Figure 2 illustrates the variation in cross-sectional dimensions along the length of the legs.
The batter applied to the structure was in line with the baseline structure and was as follows:
North direction = 6.185°
East direction = 1.606°
Figure 1 depicts the first row of conductors.) The modelling of the conductors was
simplified using tubular beam elements with an outer diameter of 0.685m and a wall thickness
of 0.030m. They were tied into the conductor guide framing using multi-point constraints that
have been configured to allow axial sliding but prevent planar motion relative to the framing
structure.
The conductors were fully restrained at a depth of 10 metres below the mud line.
2.2.5 Levels
The generic structure comprised of four levels consistent with the baseline structure that are
referred to as:
Within the jacket structure all tubular joints were modelled as rigid connections; i.e. joint
flexibility ignored.
4
2.2.7 Joint Groups
For the purpose of this study individual tubular joints between chords and braces were
grouped together to form joint groups. Each joint group within a given structure was assigned
a unique identifier, details of which are contained in Reference 2.
Five different bracing configurations were applied to the generic structure. These were as
follows:
x X-braced
x Diamond braced
x K-braced
x Inverted K-braced
x Single diagonal braced
Sizing of the bracing members was conducted by assessing the joint and member utilisation
values resulting from the structures’ exposure to the 100 year storm event for each of the three
directions considered as part of this study. Utilisation values were calculated in accordance
with the guidelines detailed in References 4 and 5. The members were sized to give
utilisation values of less than unity, with consistent slenderness ratios between corresponding
members in the each bracing configuration.
Within each bay of each structure the bracing members were of the same cross-section. Table
1 provides details of the bracing members’ cross-section dimensions for each of the five
bracing configurations.
2.4 MATERIAL
The material model used in the studies was based upon a typical structural steel, Grade
355EM, which is commonly used in the fabrication of offshore jacket structures in the North
Sea.
5
Density: 7820kgm-3
Elastic Modulus: 206.8GPa
Poisson’s Ratio: 0.29
For the Stress Redistribution Study and the buckling analysis the material was assumed to be
linear elastic. For the non-linear pushover analysis the elasto-plastic material model was
applied.
6
Table 2 Plastic material properties
355.0 0.000
461.5 0.06780
537.7 0.12744
612.3 0.21708
681.8 0.33675
709.7 0.39662
797.1 0.63620
814.9 0.69612
847.4 0.81596
890.0 0.99576
Gravity and buoyancy loads were applied to each of the five structures to effectively pre-
stress the structures. The contribution of each structural member to the overall jacket’s
buoyancy was calculated using the fluid to structure load interaction within the ABAQUS FE
software, i.e. ABAQUS AQUA. Further details on the use of ABAQUS AQUA in this study
are provided in Reference 2.
The loading applied in each of the studies conducted as part of this work was based upon the
100 year storm wave, current and wind loading as defined for the baseline jacket’s location.
The 100 year wind load was applied as a simplified point load applied at the geometric centre
of the four stab-in points and had a magnitude of 4.664kN.
The 100 year wave was modelled using gridded wave data which details the fluid particle
velocity and accelerations at a number of points in a user defined grid.
Using ABAQUS AQUA, each of the five structures were simultaneously exposed to the 100
year wave, wind and current, and the equivalent load distribution determined at the point of
maximum base shear acting on the structure. This load distribution is hereafter referred to as
the Reference Load Set (RLS).
7
Table 3 100 Year current profile
8
3. STRESS REDISTRIBUTION STUDY
3.1 BACKGROUND
The Stress Redistribution Study was a comparative study that aimed to investigate the effects
of bracing configurations, and hence redundancy levels on the degree of stress redistribution
that occurs when a member fails. The study aimed to establish the stress distribution, in terms
of joint utilisation values, calculated in accordance with Reference 5, for all joints in an
undamaged structure, as a result of the structure being exposed to the Reference Load Set
(RLS). The structure was then re-analysed with a single member severed, and the
redistribution of the load determined by reassessing the joint utilisation values. In conducting
this study a total of 15 undamaged jacket FE analyses were performed along with 354 severed
member FE analyses.
The analysis considered a 100 year storm from the following three storm directions:
North
North East
East
To aid understanding of how each structure was able to accommodate a failed member two
levels of analysis were conducted. These are referred to as a global response analysis and a
local response analysis. The global response analysis aimed to capture the effect a failed
member had on the joint utilisation distribution of all joints in the structure, and to determine
the shift in the mean joint utilisation value as well as whether any joint exceeded a utilisation
value of unity. The local response analysis aimed to capture the effect at each joint group and
to establish, using the calculated change in utilisation value, how individual joints were
affected, thus indicating how the load paths in the structures changed. Reference 6 provides
an in depth description of these two levels of analyses.
Table 4 summarises the mean joint utilisation values for the undamaged state obtained from
the global response analysis.
Reference 7 details the cumulative joint utilisation distribution curves and corresponding
density functions from the load redistribution analysis. Table 5 summarises the severed
9
member analyses that resulted in a significant shift in the mean joint utilisation value and
those analyses that resulted in joints exceeding the code based unity check.
10
Evidence from the stress redistribution analyses undertaken on the five bracing configurations
suggests that there were two distinct types of behaviour. The X-braced and the diamond
braced structures were able to accommodate member failures much more economically, in
terms of a smaller zone of influence than the inverted K-braced, K-braced, and single
diagonal braced structures. This behaviour was consistent with the perceived redundancy of
the five bracing configurations.
The lower redundancy structures incorporated a lower bay that was much stiffer than the
middle bay owing to the influence of the piles, and the end restraints on the conductors in the
lower half of the lower bay. The piles provided the lower legs with additional bending
restraint, and as such, in the event of a lower diagonal member failing, attracted the
redistributed load to the legs in the form of an axial load. However, upon failure of a middle
bay diagonal brace, the stiffness of the structure was more adversely affected, and as a result
the load from the failed member was accommodated throughout the structure. The structural
response was characterised by the structure bending about the upper half of the lower bay, at a
point coinciding with the top of the piles. In general, this response resulted in the joints at
Level 1 exhibiting higher utilisation values than other joints in the structure, as the induced
bending was reacted.
Figure 4 illustrates the impact on the distribution of joint utilisation values for the single
diagonal braced structure when a middle bay compression member was severed. From this
plot it can be seen that the general impact of this member having failed was a global increase
in the joint utilisation values throughout the structure resulting in utilisation values in excess
of the unity, thus exceeding the code based joint capacity of Reference 5. Table 6 and Figures
5 to 8 illustrate the shift in load distribution for the same case for all four frames (two parallel
to the load and two perpendicular). The figures take the form of coloured contour plots. The
following key has been used to represent the shift in joint utilisation values from the
undamaged case:
For the higher redundancy structures, the difference in stiffness between the middle and lower
bays was a lot less significant, thus the impact of a failed member was not as onerous in terms
of the induced global bending.
The difference in the global response between the X-braced and diamond braced response
was attributed to the resultant load paths when a member was severed. Failure of a diagonal
bracing member in the X-braced structure resulted in almost a total loss of the load bearing
capability of the other bracing member on the same diagonal, thus in effect two bracing
members were lost in a single bay. However, in the case of the diamond braced structure,
diagonals were split between two bays, and as such the effect on a single bay’s stiffness was
less.
Figure 9 illustrates the impact on the distribution of joint utilisation values for the X-braced
structure when a middle bay compression member was severed. From this plot it can be seen
that the global impact of this member having failed was negligible. Table 7 and Figure 10
illustrate the shift in load distribution for the same case, using the same colour code key as
previously described. The plot clearly illustrates the reduction in load on the severed
member’s diagonal, and the contiguous diagonals (i.e. the ‘zig-zag’). This is complemented
by an increase in load on the intact ‘zig-zag’.
11
Table 6 Joint utilisation values for single diagonal braced jacket in the undamaged
state and with member AM severed
Undamaged
Undamaged
Undamaged
Undamaged
Undamaged
Undamaged
Undamaged
Damaged
Damaged
Damaged
Damaged
Damaged
Damaged
Damaged
% % % % % % %
Joint
Group
L11A Leg 1A L1H1 1M 1L L1HA AM AL
0.64 0.34 86 0.30 0.11 179 0.30 0.09 245 0.28 0.05 500 0.95 0.34 175 0.01 0.56 -99 0.72 0.52 37
L11B Leg 1B L1HB L1H1
0.36 0.22 64 0.25 0.13 100 0.16 0.11 50
L12A Leg 2A L1HA L1H2
0.56 0.16 260 1.05 0.23 350 0.64 0.23 173
L12B Leg 2B L1HB BM BL
0.47 0.29 62 0.35 0.25 41 0.59 0.41 46 0.69 0.53 29 0.45 0.30 50 0.32 0.06 413 0.17 0.04 340
L21A Leg 1A L2HA L2H1
0.38 0.08 380 0.23 0.05 400 0.08 0.03 150
L21B Leg 1B L2HB BU BM L2H1 1U 1M
0.27 0.16 62 0.31 0.18 74 0.33 0.23 40 0.46 0.28 64 0.33 0.05 600 0.19 0.06 200 0.22 0.05 367
L22A Leg 2A L2H2 2U 2M L2HA AU AM
0.45 0.11 314 0.22 0.13 75 0.20 0.05 257 0.16 0.03 400 0.28 0.18 57 0.15 0.17 -14 0.01 0.37 -98
L22B Leg 2B L2H2 L2HB
0.06 0.04 60 0.19 0.05 300 0.27 0.11 143
ML1A Leg 1A MLHA MLH1
0.05 0.08 -40 0.58 0.54 7 0.22 0.13 65
ML1B Leg 1B MLHB BL MLH1 1L
0.10 0.08 30 0.47 0.34 36 0.67 0.52 30 0.05 0.09 -45 0.14 0.03 350
ML2A Leg 2A MLH2 2L MLHA AL
0.05 0.06 -25 0.17 0.09 100 0.19 0.05 300 0.57 0.54 6 0.48 0.48 -2
Table 7 Joint utilisation values for X-braced jacket in the undamaged state and with
member AM1L severed
Undamaged
Undamaged
Undamaged
Undamaged
Undamaged
Undamaged
Undamaged
Damaged
Damaged
Damaged
Damaged
Damaged
Damaged
Damaged
% % % % % % %
Joint
Group
Leg 1A MLHA AL1L MLH1 1LAL
ML1A
0.08 0.08 0 0.06 0.05 17 0.70 0.64 10 0.08 0.08 0 0.13 0.14 -6
Leg 2A MLH2 2LAL MLHA AL2L
ML2A
0.07 0.07 0 0.12 0.14 -12 0.10 0.11 -14 0.05 0.06 -14 0.34 0.40 -16
Leg 1A L1H1 1MAL 1LAU L1HA AM1L AL1U
L11A
0.30 0.30 0 0.13 0.11 23 0.18 0.16 10 0.18 0.15 22 0.41 0.12 233 0.01 0.45 -98 0.39 0.44 -11
Leg 2A L1HA AM2L AL2U L1H1 2M2L 2L2U
L12A
0.24 0.23 4 0.34 0.15 133 0.48 0.28 71 0.75 0.67 11 0.23 0.25 -7 0.15 0.12 20 0.15 0.11 29
Leg 1A L2H1 1UAL 1MAU L2HA AU1L AM1U
L21A
0.15 0.11 29 0.05 0.03 50 0.08 0.11 -23 0.12 0.11 15 0.30 0.09 227 0.25 0.20 20 0.34 0.19 83
Leg 2A L2H2 2UAL 2MAU L2HA AU2L AM2U
L22A
0.05 0.07 -33 0.02 0.07 -75 0.08 0.10 -17 0.07 0.07 0 0.19 0.15 28 0.08 0.11 -29 0.02 0.30 -92
12
3.3 STRESS REDISTRIBUTION STUDY SUMMARY
x The X-braced and the diamond braced structures are able to accommodate member
failures much more economically than the inverted K-braced, K-braced, and single
diagonal braced structures. This behaviour is in-line with perceived redundancy of the
five bracing configurations.
x For the leaner structures, failure of a middle bay diagonal brace had the largest impact on
structural stiffness and joint utilisation values. In general, the joints at Level 1 exhibited
higher utilisation values than other joints in the structure, as the induced bending was
accommodated.
x For the higher redundancy structures, the impact of a failed member was generally not as
onerous as the case for the leaner structures. However severance of a lower bay member
had a significant impact locally on joint utilisation values.
x The difference in the global response between the X-braced and diamond braced
structures’ response was attributed to the resultant load paths when a member was
severed. Failure of a diagonal bracing member in the X-braced structure resulted in
almost a total loss of the corresponding diagonal’s ability to bear load, thus in effect two
bracing members were lost in a single bay. However, in the case of the diamond braced
structure, diagonals are divided between two bays, and as such the effect on a single bay’s
stiffness was not as severe.
13
BLANK PAGE
14
4. CRACKED MEMBER STUDY
4.1 BACKGROUND
In addition to the severed member runs detailed in Reference 6 a series of FE analyses were
performed on a part cracked member. Circumferential, through wall cracks were introduced
into a bracing member that was subjected to a tensile load to establish the impact on the load
distribution. This was limited to a single member on the single braced structure, subjected to
the East storm load condition, to limit the amount of data generated. The single braced
structure was chosen for the focus of this study owing to the limited number of load paths that
it possesses, and the impact of a failed member on the stress distribution. The member
selected for the insertion of a crack was member BM owing to its impact on the stress
distribution upon being severed and the fact that in the undamaged structure the member was
nominally in tension in the undamaged state.
The single braced jacket model was modified using shell elements to introduce a crack into
the middle bay diagonal brace in Frame B, i.e. member BM. This involved removing
approximately 4m of beam elements from the member about its mid span and replacing them
with two identical sub-models comprising of a cylinder, generated using a regular shell
element mesh. The sub-model was tied into the beam elements using ‘DCOUP3D’ type
elements from the ABAQUS (Reference 3) element library. These elements are specifically
formulated to enable beam to shell modelling.
The crack was introduced into the model by simply ‘stitching up’ the two shell sub-models.
This process basically involved tying together a number of the coincident nodes on the two
sub-models until the required crack length had been created, with the crack being defined by
the un-stitched coincident node pairs.
The cracked sizes introduced into the model ranged from 20% to 70% of the circumference.
Using the approach detailed here it was not possible to model crack sizes beyond 70% owing
to convergence problems in the FE analysis.
4.3 RESULTS
The results from the cracked member study at joint groups L12B and L21B are illustrated in
Figures 12 and 13 in the form of bar charts signifying the joint utilisation at each joint within
the joint groups for a variety of crack sizes. Similar plots were generated for all the joint
groups at and below Level 2 in the structure, but these demonstrated little changes in
utilisation values except in the case where the member was fully severed. Figure 14 provides
an illustration of these plots for joint group L11A.
Figure 15 illustrates the displaced shape of the shell element sub-model for the 70% fully
circumferential crack and Figure 16 illustrates the Von-Mises stress contours local to the
crack for the same case.
15
4.4 DISCUSSION
In general, the impact of a crack being introduced into member BM at mid-span had limited
effect on the load distribution in comparison to the undamaged state, for crack sizes up to
70% of the circumference. However those joint groups that included the cracked member, i.e.
L12B and L21B were affected quite significantly.
At joint group L12B, the effect on the cracked member was a steady increase in the utilisation
value calculated as the crack grew to being 70% of the circumference. Such behaviour can be
attributed to the resultant bending of the member owing to its increased compliance due to the
local eccentricity of the neutral axis near the crack. The effect on member BL was limited,
with only a slight increase in load observed. However the effect on the horizontal brace at
Level 1 in Frame B, i.e. member L1HB was much more pronounced. As the crack grew more
load was redistributed to this member, resulting in an almost doubling of the undamaged
state’s utilisation value when the crack was 70% of the circumference.
The out of plane effects at joint group L12B were a slight increase in the load on member 2M,
and a reduction in load on members 2L and the horizontal brace at Level 1, i.e. member
L1H2. The limit on the out of plane effects was considered to be as a result of the stiffness of
the lower bay preventing rotation of the structure at Level 1.
At level 2, joint group L21B, the load on member BM again increased steadily as the crack
grew from 0% to 70% of the circumference, again attributed to the increased compliance of
the member. The effects on the horizontal member at Level 2 in Frame A was a steady
decrease in the load as the crack grew to 70% of the circumference, but a slight increase over
the undamaged state value for the severed condition. The effects on member BU were
negligible.
Out of plane, the effects were much more pronounced at Level 2 than at Level 1. A steady
increase in load was observed in member 1M as the crack grew, as was the case in the
horizontal member at Level 2, i.e. member L2H1. Such effects have been attributed to the
induced twisting of the jacket about the vertical axis.
Using the approach adopted here and the mesh refinement of the crack zone it was not
possible to obtain a converged solution for cracks in excess of 70% of the circumference, due
to numerical problems. It is considered that a revised approach to introducing cracks into the
structure, using a fracture mechanics mesh and the possible introduction of gap elements, to
model crack closure, would help the solution to converge and thus yield results. However, it
is considered that unzip times for larger cracks would be relatively short and therefore there
would be limited benefit in investigating the structural response for such cracks, in the context
of demonstrating increased global structural reliability.
The study has demonstrated that for crack sizes up to 70% of the circumference of a bracing
member:
x The impact on the load distribution was limited. Significant effects were only observed in
regions of the structure that were local to the cracked member. The increased compliance
of the cracked member introduced twisting into the structure that resulted in out of plane
effects as well as local in-plane effects.
x The joint utilisation of the cracked member’s joints increased due to the increased
compliance of the member caused by the eccentricity of the member’s neutral axis local
to the cracked region.
16
The modelling approach adopted in this study to insert a crack into a bracing member was
inadequate for performing a fracture mechanics assessment on the cracked member. As a
result it was not possible to predict unzip times for the crack. However, it is considered that
unzip times for large cracks are relatively short and therefore there would be limited benefit in
investigating the structural response for larger cracks than those considered here.
17
BLANK PAGE
18
5. ULTIMATE STRENGTH ANALYSIS
5.1 BACKGROUND
Each of the five bracing configurations was subjected to a series of static non-linear, pushover
analyses, in both the damaged and undamaged states, for an East storm load case. The
purpose of the study was to establish the ultimate strength of the jackets in the undamaged
state (i.e. the reserve strength ratio, RSR) and to assess the impact on the ultimate strength
when the structure contained at least one severed member (i.e. to establish the damaged
strength ratio, DSR). This study aimed to establish a member criticality profile for each
bracing configuration to feed into the structural reliability assessment for each of the jacket
types.
Reference 9 provides further details and a detailed description of the study conducted.
In the undamaged states the five bracing configurations can be ranked in descending order
according to the RSRs calculated for the East storm load case;
It is considered that this ranking can be attributed to the variation in the ‘step’ change in
stiffness between the lower and middle bays. The number of load paths available local to
Level 1, to react the resultant compressive load induced in the structure determines the
magnitude of this step. The more load paths available, the lower the axial compressive load
in a given member; therefore there is a rise in the calculated RSR. Furthermore, the presence
of more load paths also has the effect of reducing the bending of the structure and as such the
end moments acting on bracing members is limited. The effect of this is that the reduction in
the critical buckling load of a particular member due to bending, is limited.
From the single member severed study conducted, it is evident that there are two distinct
types of behaviour. As was the case in the stress redistribution study undertaken, the X-
braced and the diamond braced structures were able to accommodate member failures much
more economically than the lower redundancy structures, i.e. inverted K-braced, K-braced,
and single diagonal braced structures. This behaviour was consistent with the perceived
redundancy of the five bracing configurations, and is illustrated in Table 8 and Figure 17 by
the difference in the range of DSRs calculated for each of the bracing configurations.
Severance of a member in either the middle or lower bays of the lower redundancy structures
introduced twisting into the structures and resulted in an increase in load on the lower
members thus initiating buckling of such members at lower values of LPF, resulting in lower
DSR’s. Furthermore, in most cases the legs at the back of the structure, i.e. gridline 1
experienced plastic strains local to the top of the piles.
19
Table 8 Damaged jackets ultimate strength results
Severance of an upper bay member, in the lower redundancy structures, generally resulted in
an increase in the jacket’s ultimate strength (i.e. collapse load). Such effects were attributed
to the induced torsion in the jackets and the impact that this had on the load distribution in the
lower bay. For such damaged states the load was distributed to the perpendicular frames as
they reacted rotation of the legs, and thus alleviated the load on the lower compression
members in the frames parallel to the storm direction.
The K-braced structure was found to be the least tolerant to a severed member. Regardless of
which member was severed in either the lower or middle bays there was a significant impact
on the calculated ultimate strength.
20
The multiple member severance study further highlighted the difference between the low and
high redundancy structures. Severance of two members on the inverted K-braced structure
had a significant impact on ultimate strength, resulting in a 40% reduction, whereas that
performed on the X-braced structure resulted in a 20% reduction. Table 9 provides details of
the DSR and RRF for these analyses.
21
structure had a significant impact on ultimate strength, resulting in a 40% reduction,
whereas that performed on the X braced structure resulted in a 20% reduction.
22
6. RELIABILITY STUDY
6.1 BACKGROUND
The ultimate aim of this project was to demonstrate the structural reliability of fixed jackets of
different bracing configurations designed to a given set of criteria, and in particular to
demonstrate the effect of stress redistribution due to damage on overall reliability.
In this work, five jackets were designed based on elastic limit state methods for the same
water depth, topside loads and environmental conditions, but with differing bracing
configurations.
Non-linear Ultimate Strength (Pushover) analyses were performed on each of these jackets in
their undamaged conditions. The analyses were also performed for a range of damaged
conditions for each of the jackets. (The term ‘damage’ here is used to refer to the complete
severance of a member – pushover analyses were not performed on partially cracked
members).
This study takes into consideration the findings from the stress redistribution study and the
ultimate strength study, in conjunction with published Environmental Load distributions to
produce through-life reliabilities for the different jackets and to demonstrate the ‘knock-on’
effect of redistributed stress on the reliability of the structures.
i
Pf ¦PP
i
i storm
where i represents the number of ‘states’ in which a structure can exist (since we are dealing
only with severed or unsevered members here, the mathematics is discrete). Pi is the
probability that the structure exists in the i’th state, and Pstormi is the probability of a storm
occurring with sufficient strength to cause the collapse of the structure in the i’th state.
The two legs of the approach are therefore based on
x Calculating the probability of the structure existing in the i’th state.
x Calculating the probability of a storm to cause the collapse of the structure in the i’th state.
As mentioned, this two-legged approach is illustrated in Figure 18 and is described in more
detail below.
23
6.2.1 Probability of Structure Existing in a Given State, Pi
If there are N members in a given structure and each of these members may exist in either an
intact or a severed condition then the structure may exist in any one of N! possible states.
In Reference 10 this method was developed for single member failure only – i.e. the
possibility of more than one member failing during an inspection interval was ignored. One
of the objectives of this study is to demonstrate the effect of considering multiple member
failure on structural reliability.
The method used to calculate the probabilities of member failure for single and multiple
member failure is described below.
Single Member Failure Probabilities
In Reference 10 a method was presented to predict the probability of member failure based on
probabilistic fracture mechanics methods. These methods use the calculated fatigue lives of
members and the time in service to estimate the accumulated fatigue damage (S3N) that a
member has endured at a given time. The results of probabilistic fracture mechanics
calculations performed using UMFRAP (Umist Fracture and Reliability Assessment Program
- see Reference 11) were plotted as probabilities of member failure versus the accumulated
fatigue damage for a given member. Different curves were generated for given member
dimensions, initial defect sizes and defect distributions.
Figure 19 is an example curve of cumulative probability of failure versus S3N for one
particular member geometry and defect case.
The probability of failure within a given time interval is calculated by assessing the
accumulated fatigue damage (S3N) at the beginning and the end of the inspection interval. The
probability of failure during the interval is then simply the difference between the cumulative
probabilities at the end and the beginning of the inspection interval. This may be expressed as
p interval
f P S3N end P S 3N beginning
The method described above was developed using curves generated by Professor Burdekin of
UMIST (Reference 11) and shall be referred to as the Burdekin method from hereon.
The rate of accumulated fatigue damage is calculated using the design fatigue lives of
members (or individual welds if available). For example, for a Class W weld, the fatigue life
is deemed to have been expended when the accumulated fatigue damage, S3N = 1.4x1012. The
rate of accumulated fatigue damage is then simply calculated by scaling the appropriate factor
(eg S3N = 1.4x1012) by the proportion of the fatigue life that has been expended. Thus, a
member with a fatigue life of 100 years will have an accumulated damage of S3N = 1.4x1011
after a period of ten years.
As part of this study two reliability assessments have been performed. The first assessment
assumed a fatigue life of 100 years for each and every member whilst the second study
assumed a fatigue life of 50 years for each and every member. This was done because it was
considered more important to assess the effect of the different bracing configurations (i.e.
redundancy and stress redistribution) on the resultant, calculated reliabilities for the five
structures. If a distribution of fatigue lives had been used, the interpretation of the data would
have been more difficult. Of course, it is acknowledged that this assumption is unrealistic,
but it was considered to be worthwhile for making the demonstration of the effect of
redundancy on structural reliability.
Probabilities of failure for each member were calculated using the Burdekin method over a
period from the present day to the year 2025. The assumed installation date was 1985. The
method was applied assuming a 3 yearly, 100% effective FMD inspection regime. The
number of welds was calculated assuming approximately 4m long joint cans. The number of
24
defects was calculated assuming the defect distributions presented in Reference 11. The
initial defect size was assumed to be normally distributed with a mean depth of 6mm.
Multiple Member Failure Probabilities
As stated above, one of the key objectives of this work was to demonstrate the importance (or
not) of considering the effects of multiple member failure on jacket structural reliability.
When damage occurs to a jacket (in this case represented by the severance of a member) the
stresses are redistributed to other members in the jacket. This has been discussed earlier in
this report.
In general, when a member is severed the loads carried by adjacent members are increased.
This means that the rate of accumulated fatigue damage is accelerated. From the results
presented in Appendix B it is not unusual to see stresses in neighbouring members to increase
by 100%. This would mean that the rate of accumulated fatigue damage would be accelerated
by a factor of 8 (=23). Some members have even higher predicted redistributed loads with
associated consequences for the shortening of their fatigue lives.
Due to the many permutations associated with multiple member failure it was decided to
make the demonstration of multiple member failure on two bounding cases. These cases were
selected to encompass the overall range of jacket robustness and damage tolerance.
The first case chosen was for the inverted-K braced structure. This was chosen since it
demonstrated the lowest overall ultimate strength and a sensitivity to damage (the lowest
residual resistance factor for the inverted K-braced structure was 0.797). In this structure, the
two members that were severed for the multi-member study were the two tension members in
the middle bay.
The other case chosen for the multi-member study was the X-braced structure that
demonstrated a lower-bound RRF of 0.884. In this case, two members in the lower bay were
severed, one on each diagonal of the bay’s bracing.
Fatigue Acceleration
As mentioned above, when a member is damaged, adjacent members have to somehow
accommodate the load. In general this leads to an increase in stressing in the members and
joints. This leads to an acceleration in fatigue damage and an associated increase in the
probability of member failure during a given time interval.
From the detailed stress redistribution work (Appendix D) the stress enhancements were taken
for one of the members due to the failure of the other member used in the multi-member
study.
In the Inverted K braced structure, the failure of one of the middle bay tension members
produced an enhancement in stress in the middle bay tension member on the opposite frame
of 1.66.
For the X-braced structure the severance of one of the lower bay diagonals produced an
enhancement in stress in the other diagonal of 1.55.
The two stress enhancements above produced a fatigue damage acceleration of 4.1 for the
Inverted K braced structure and 3.7 for the X-braced structure.
These fatigue accelerations were taken into account when applying the Burdekin method to
calculate the probability of failure of the second member, subsequent to failure of the first
member. Again, for demonstrative purposes, it was assumed that the first member failure
occurs on the day after a FMD inspection returned a negative result, meaning that the
accelerated fatigue damage is present during the entire of the next inspection interval.
25
6.2.2 Probability of Storm to Cause Collapse in the i’th state, Pstormi
The probability of a structure collapsing, given that it exists in a certain state is simply
calculated by using the results of ultimate strength calculations cross-referenced with
environmental load distributions.
The environmental load distributions relate the environmental load that a storm produces to
the storm’s return period. Therefore, if we know the ultimate strength of a structure, we can
calculate the return period of the storm with a load equal to the structure’s strength. The
annual probability of failure is then simply the inverse of the return period.
In this work, the environmental load distribution that was used was
PE A exp§¨ E ·¸
© Eo ¹
where P(E) is the annual probability of the occurrence of a storm exceeding a load, E, and
E=ERP/E100 where ERP is the load corresponding to a given return period, RP, and E100 is the
most probable 100 year load. In the above, A and Eo are constants. In this assessment, these
values were taken as 180 and 0.102 respectively, values typical of the Central North Sea
(Reference 4).
6.3 RESULTS
26
6.4 DISCUSSION
i N
Pno _ failures 1 Pi
i 1
where the ‘pi’ symbol indicates the multiplication of all the terms (1-Pi).
Evidently, during the early life of the structure, the individual probabilities of member failure,
Pi, are very small and so the probability of no failures having occurred is close to unity. With
time, however, as the probabilities of member failure increase, the probability of there being
no failures decreases.
This information could be used to provide a Bayesian updating approach. Say, for example
that the results of an inspection show no failures and that our model predicts that this would
only be possible 1% of the time, based on our initial assumptions of defect size, then we can
state with 99% confidence that our initial assumption was too onerous. The assessment would
27
then be repeated for a less onerous initial defect assumption. This process could then be
repeated for subsequent inspections (see Figure 22).
At present, this functionality has not been built into the code that performs the reliability
assessments.
28
x Stress redistribution effects are more pronounced for low redundancy structures (eg
inverted K braced), where ultimate strengths are more sensitive to damage and stresses are
redistributed globally. This is in contrast to high redundancy structures (eg X-braced)
where stress redistribution tends to be more localised and the ultimate strength of the
structure is less sensitive to damage.
29
BLANK PAGE
30
7. CONCLUSIONS
A series of studies have been performed to investigate the impact of five different bracing
configurations on the structural response of a 3 bay, four-legged jacket standing in the
Southern North Sea in approximately 45m of water. The studies comprised of a stress
redistribution study, ultimate strength study and a reliability study for different damage states
within each of the five bracing configurations.
x The stress redistribution study provided a comprehensive assessment of the impact of
a severed member on the stress distribution in a jacket structure incorporating one of
the five bracing configurations, for three storm directions.
x In addition to the severed member redistribution study a limited study was performed
to establish the impact of a cracked member on the stress distribution of a structure
with a particular bracing configuration, for the East storm load case.
x The Ultimate strength study and the reliability study focussed on the East storm load
case for each of the five bracing configurations.
x The reliability assessment provided an insight into how the redistribution of load as a
result of one member being severed can accelerate the probability of a second
member failing and the resultant impact on jacket reliability.
Both the stress redistribution study and the ultimate strength study for the undamaged
structures, and those incorporating a single member severed, have highlighted two distinct
types of behaviour, i.e. that of the lower redundancy structures and that of the higher
redundancy structures. The higher redundancy structures were defined as the X and diamond
bracing configurations, whereas the lower redundancy structures were defined as the inverted
K, K and single diagonal bracing configurations.
Severance of a bracing member in one of the lower redundancy structures had a much wider
impact on the load distribution, with a resultant twisting of the structure about the vertical
axis. In terms of ultimate strength the impact was seen as a significant reduction in load
capacity, particularly for the case where a lower bay tension member was severed. Such
failures resulted in an increase in load on the lower bay compression members resulting in the
member buckling under a reduced applied load.
The higher redundancy structures demonstrated a higher resilience to member failure. From
the stress redistribution studies, the impact of a severed member was very localised, with the
zone of influence being restricted to Frame A for the cases considered. The ultimate strength
studies again demonstrated the damage tolerance of these structures, as relatively small
reductions in ultimate strength were observed, with severance of a lower tension member
having the biggest impact.
The dual member severed study was performed on the X-braced structure and on the inverted
K-braced structure, as these provided the extreme ultimate strength values. For the lower
redundancy structure, the impact of two members having been severed was a drastic reduction
in ultimate strength, whereas the effect observed in the case of the higher redundancy
structure was much less severe.
Two notable results from the ultimate strength studies were that of the K-braced structure and
the single diagonal braced structure. The K-braced structure proved to be the most sensitive
to a severed member. Although the size of the members was the same as the inverted K-
braced structure, its load paths were significantly different and as such, loss of any members
in the lower or middle bays resulted in significant twisting and bending of the jacket. The
impact of a severed member had a more pronounced impact on the deformations observed
local to Level 1.
31
Start-of-life reliabilities are dependent on the undamaged ultimate strengths of the jackets.
The elastic limit state design criterion used predicted that (in the undamaged condition) the X-
braced structure was the most reliable, followed by the Single Diagonal, then the K-braced,
the Diamond braced and finally, the Inverted K.
The most reliable bracing configurations are those with higher levels of redundancy. These
jackets are shown to be more damage tolerant than jackets with low levels of redundancy (i.e.
they have higher Residual Resistance Factors).
Stress redistribution causes an acceleration in the rate of fatigue damage at neighbouring
members when damage occurs. This causes an increase in the probability of failure of the
neighbouring members and an associated increase in overall platform collapse due to
multiple-member failure. This effect has been demonstrated for two multiple-member failure
cases; one on the X-braced structure and one on the inverted K braced structure.
It is considered that the work reported upon in this report and its associated appendices
provides the first steps towards developing a reliability based performance measure for
jackets. The report has provided evidence of the types of jackets that carry the largest risk of
structural failure.
32
8. RECOMMENDATIONS
As a result of this study a number of recommendations are put forward to extend the work
completed to date aimed at investigating the effects of stress redistribution in damaged structures
and the impact that this has on the predicted reliability of jacket structures. These recommendations
are detailed below.
x Extend study to incorporate larger structures, i.e. deeper water 4 leg jackets and jackets with
more than 4 legs.
x Extend the analysis on dual member failures to incorporate all of the five bracing
configurations, taking into consideration critical members having failed and the stress
redistribution within the structure. The study would then be used to provide estimates for
fatigue acceleration factors, FAFs, for each member in a given bracing configuration to feed
into an estimation of the structural reliability prediction and thus provide guidance to operators
on how to determine the acceptability of damage within a structure.
x Devise methodology for Bayesian updating of a structure’s reliability prediction following a
structural inspection. The reliability prediction is based upon an assumed defect or defect
distribution that is present at the start of life. Through life modelling of a structure’s reliability
may yield a high probability of a member severing at some stage in the design life, which may
be invalidated by inspection results, thus necessitating the revision of initial assumptions and
the through life reliability profile.
It is anticipated that following completion of this proposed work, it will be possible to formulate
suitable guidance to enable an informed judgement to be made on the acceptability of damage in a
jacket structure, based upon the bracing configuration, and the impact that this will have on other
members in the structure. In addition, the future work will allow guidance to be formulated on
calculating a more accurate prediction of through life structural reliability using probabilistic
fracture mechanics and Bayesian updating.
33
BLANK PAGE
34
9. REFERENCES
1 Guidance on the Use of Flooded Member Detection for Assuring the Integrity of Offshore
Platform Substructures – EQE Report N° 179-03-R-07 Issue 1 – 6th June 2000
2 Stress Redistribution in Platform Substructures Due to Primary Member Damage and its
Effect on Structural Reliability – EQE Report N° 45-20-R-01 Draft – 19th January 2001 –
Appendix A – Model Description
3 ABAQUS 5.8 – Hibbitt, Karlsson & Sorensen, Inc.
4 API 2A-LRFD Recommended Practice for Planning, Designing and Constructing Fixed
Offshore Platforms – Load and Resistance Factor Design, First Edition 1993
5 Offshore Installations: Guidance on Design, Construction and Certification – Fourth
Edition-1990, HMSO – Appendix A21
6 Stress Redistribution in Platform Substructures Due to Primary Member Damage and its
Effect on Structural Reliability – EQE Report N° 45-20-R-01 Draft – 19th January 2001 –
Appendix B – Stress Redistribution Study
7 Stress Redistribution in Platform Substructures Due to Primary Member Damage and its
Effect on Structural Reliability – EQE Report N° 45-20-R-01 Draft – 19th January 2001 –
Appendix C – Joint Utilisation Value Distribution Plots
8 Stress Redistribution in Platform Substructures Due to Primary Member Damage and its
Effect on Structural Reliability – EQE Report N° 45-20-R-01 Draft – 19th January 2001 –
Appendix D – Joint Group Utilisation Value Plots
9 Stress Redistribution in Platform Substructures Due to Primary Member Damage and its
Effect on Structural Reliability – EQE Report N° 45-20-R-01 Draft – 19th January 2001 –
Appendix F – Ultimate Strength Study
10 Demonstration of the Effect of FMD on Structural Reliability (Appendix n to FMD JIP
Final Report) – EQE Report N° 179-03-R-06 Appendix N, Issue 1, 4 May 1999
11 Fabrication Defects Study (Appendix C to FMD JIP Final Report) - EQE Report N° 179-
03-R-06 Appendix C, Issue 1, 4 May 1999
12 Final Report on Reliability Aspects (Appendix K to FMD JIP Final Report) - EQE Report
N° 179-03-R-06 Appendix K, Issue 1, 28 April 2000
13 M Efthymiou, J W van de Graaf, P S Tromans and I M Hines, ‘Reliability based criteria
for fixed steel offshore platforms.’
35
BLANK PAGE
36
+21.5 m
+10 m
-8.5 m
-26 m
z North
-43.5 m East
37
+21500
6
5
2000
+10000
4
7826
3
2750 3250
-8500
2
-26000
1 Section details
1. 1400 x 65
2. 1400 x 85
3. 1400 x 35
4. 1400 x 75
5. 1215 x 50
-43500
6. 1030 x 60
38
X-Braced Diamond Braced
39
Single Diagonal Braced East Storm S−AM Severed
Cumulative Distribution Function
1
0.8
Proportion of Joints
0.6
0.4
Undamaged − data
Undamaged − CDF
0.2 Damaged − data
Damaged − CDF
0
0 0.2 0.4 0.6 0.8 1 1.2
10
Undamaged PDF
Probability Density Function
Damaged PDF
8
0
0 0.2 0.4 0.6 0.8 1 1.2
Joint Element Utilisation
40
1A AU 2A
AM 2A
1A
1A AL 2A
41
1B BU 2B
BM 2B
1B
1B BL 2B
42
1A 1U 1B
1M 1B
1A
1A 1L 1B
43
2A 2U 2B
2M 2B
2A
2A 2L 2B
44
X−Braced East Storm C−AM1L Severed
Cumulative Distribution Function
1
0.8
Proportion of Joints
0.6
0.4
Undamaged − data
Undamaged − CDF
0.2 Damaged − data
Damaged − CDF
0
0 0.2 0.4 0.6 0.8 1 1.2
10
Undamaged PDF
Probability Density Function
Damaged PDF
8
0
0 0.2 0.4 0.6 0.8 1 1.2
Joint Element Utilisation
45
1A 2A
AU1L AU2L
AM1U AM2U
2A
1A
LMA
AM1L AM2L
AL1U AL2U
1A 2A
LLA
AL1L AL2L
46
Figure 11 Member BM
47
1.4
1.2
1.0
Leg 2B
0.8 L1HB
Utilisation
BM
BL
L1H2
0.6 2M
2L
0.4
0.2
0.0
0 20 40 60 80 100
Crack size
0.5
0.4
Leg 1B
0.3
L2HB
Utilisation
BU
BM
L2H1
1U
0.2
1M
0.1
0.0
0 20 40 60 80 100
Crack size
48
1.0
0.8
Leg 1A
0.6
L1H1
Utilisation
1M
1L
L1HA
AM
0.4
AL
0.2
0.0
0 10 20 30 40 50 60 70 80 90 100
Crack size
49
50
3
DISPLACEMENT MAGNIFICATION FACTOR = 5.00
2
RESTART FILE = sin_e_cr30 STEP 3 INCREMENT 9
1
TIME COMPLETED IN THIS STEP 1.00 TOTAL ACCUMULATED TIME 3.00
ABAQUS VERSION: 5.8-1 DATE: 12-DEC-2000 TIME: 12:16:33
MISES VALUE
+1.11E+07
+2.68E+08
+5.26E+08
+7.83E+08
+1.04E+09
+1.30E+09
+1.55E+09
+1.81E+09
+2.07E+09
+2.33E+09
+2.58E+09
+2.84E+09
+3.10E+09
+3.36E+09
51
2
DISPLACEMENT MAGNIFICATION FACTOR = 5.00
2.5
2.3
Undamaged
Lower Compression
R Lower Tension
1.9
1.7
1.5
X Diamond Inverted K K Single diagonal
Bracing Configuration
Figure 17 Plot of calculated RSR for the 5 bracing configurations for both
damaged and undamaged states
Demonstration of the change in probability of failure (collapse) of a structure when a member is severed (or inspection interval is increased).
i=N
j=M
i
6
Pf = P jstorm i
P sever
j=1
i=1
Probability of storm to cause collapse Annual probability of a severed member over inspection period R
10 -8
S3N
Pushover
Redundancy undamaged
analysis and code LPF FRACTURE MECHANICS FATIGUE & FRACTURE MODEL
check compliance damaged
damaged
FABRICATION DEFECT STRESS ULTIMATE STRENGTH
1.0 INFORMATION INTENSITY SOLUTIONS
disp FACTORS
52
Probability of Fracture
Constant Amplitude Loading
Pure Tension
Brace Make-up Weld Defects - Thickness 60 mm
101
PF
100 PF = 1.0
-1
PFZ
10
10-2 S^3N v Fracture 0.02
10-3
PFZ-1
10-4
10-5
10-6
10-7
10-8
10-9
10-10
10-11
10-12
10-13 3
S N at Z years = 1012
10-14 S3N at PF 1.0 x Z / fatigue design life in years
10-15
1010 1011 1012 3 1013
S N at PF =1.0
3 3
S N at Z -1 years = 2x1011 S N
3
S N at PF 1.0 x Z-1 / fatigue design life in years
53
1 .0 0E -0 4
1 .0 0E -0 5
1 .0 0E -0 6
X - b race d
D iam ond
K - braced
Pf
Inverted K
D iag ona l
1 .0 0E -0 7
1 .0 0E -0 8
1 .0 0E -0 9
1 980 19 85 19 90 199 5 2 000 2 005 20 10 201 5 2 02 0 2 025
y ear
Figure 20 Annual probability of failure for the five bracing configurations considering
single member failure only (100 year fatigue lives)
1.00E-04
1.00E-05
1.00E-06
X - braced
Diamond
K - braced
Pf
Inverted K
Diagonal
1.00E-07
1.00E-08
1.00E-09
1980 1985 1990 1995 2000 2005 2010 2015 2020 2025
year
Figure 21 Annual probability of failure for the five bracing configurations considering
single member failure only (50 year fatigue lives)
54
Figure 22 Relationship between probability that member remains un-severed and
predicted structural reliability
55
1.00E-04
1.00E-05
X - Single
X - Double (Redistribution ignored)
1.00E-07 X - Double (Redistribution included)
1.00E-08
1.00E-09
1980 1985 1990 1995 2000 2005 2010 2015 2020 2025
year
Figure 23 Annual probability of failure for the X-braced and Inverted K-braced
structures assuming (i) Single Member failure only, (ii) Double Member failure
ignoring the effects of redistribution and (iii) Double Member Failure including the
effects of redistribution
56
APPENDIX A
MODEL DESCRIPTION
57
BLANK PAGE
58
CONTENTS
Page
CONTENTS................................................................................................ 59
1. INTRODUCTION.................................................................................. 61
5. MATERIAL MODEL............................................................................. 77
6. LOADING............................................................................................. 79
6.1 STORM CONDITIONS ....................................................................... 79
6.2 THE 100 YEAR MET-OCEAN EVENT ................................................. 79
6.3 REFERENCE LOAD SET ................................................................... 79
6.4 MODELLING OF FLUID-STRUCTURE INTERACTION .............................. 79
7. MODEL DEVELOPMENT .................................................................... 83
8. REFERENCES..................................................................................... 85
List of Tables
A1 Horizontal bracing members’ identifiers
A2 X-brace structure’s member sizes
A3 X-braced structure’s joint group details
A4 Diamond braced structure’s member sizes
A5 Diamond braced structure’s joint group details
A6 Inverted K-braced structure’s member sizes
A7 Inverted K-braced structure’s joint group details
59
A8 K-braced structure’s member sizes
A9 K-braced structure’s joint group details
A10 Single diagonal braced structure’s member sizes
A11 Single diagonal braced structure’s joint group details
A12 Plastic material properties for grade 355EM steel
A13 Baseline SNS location current data
List of Figures
A1 Generic structure
A2 Generic structure leg schematic
A3 Mud line frame
A4 Level 1 frame
A5 Level 2 frame
A6 Level 3 frame
A7 X-braced structure member identifiers – Frames A and B
A8 X-braced structure member identifiers – Frames 1 and 2
A9 X-braced structure joint group identifiers– Frames A and B
A10 X-braced structure joint group identifiers– Frames 1 and 2
A11 Diamond braced structure member identifiers – Frames A and B
A12 Diamond braced structure member identifiers – Frames 1 and 2
A13 Diamond braced structure joint group identifiers– Frames A and B
A14 Diamond braced structure joint group identifiers– Frames 1 and 2
A15 Inverted K-braced structure member identifiers – Frames A and B
A16 Inverted K-braced structure member identifiers – Frames 1 and 2
A17 Inverted K-braced structure joint group identifiers– Frames A and B
A18 Inverted K-braced structure joint group identifiers– Frames 1 and 2
A19 K-braced structure member identifiers – Frames A and B
A20 K-braced structure member identifiers – Frames 1 and 2
A21 K-braced structure joint group identifiers– Frames A and B
A22 K-braced structure joint group identifiers– Frames 1 and 2
A23 Single diagonal braced structure member identifiers – Frames A and B
A24 Single diagonal braced structure member identifiers – Frames 1 and 2
A25 Single diagonal braced structure joint group identifiers– Frames A and B
A26 Single diagonal braced structure joint group identifiers– Frames 1 and 2
A27 Member sizing design process
60
1. INTRODUCTION
Figure 1 illustrates the generic structure along with the grid line references and the applied
storm directions.
A number of simplifications were made to the generic model as well as changes to the
dimensions of members/piles taken from the baseline jacket. These changes were as a
result of the model development phase and were due to the introduction of the different
bracing configurations to the generic model and the impact on the failure mode of the
structure in the ultimate strength studies.
61
BLANK PAGE
62
2. GENERIC DESIGN DESCRIPTION
2.1 TOPSIDES
The topsides’ weight was based upon that of the baseline jacket that weighs 1200 tonnes.
This was represented in the generic model as a single mass element located at a height of
5 metres above the stab-in points for the jacket, at the geometric centre of the jacket’s plan
view. The topsides were tied into the stab-in points using beam type ‘multi-point
constraints’ which effectively formed a rigid link between the topsides’ mass element and
the stab-in points.
2.2 PILES
The piles were originally modelled using design data from the baseline jacket, i.e. 8 insert
piles, 2 per leg, with the following cross-sectional dimensions:
At the point where the piles were sleeved and grouted and tied into the structure, an
effective cross section was calculated that would provide similar bending restraint to the
composite section. The following dimensions were originally used; outer
diameter = 1.913.9m, wall thickness = 0.0896m. Preliminary pushover analyses
demonstrated that the piles dominated the ultimate strength of the jacket, with failure of the
jacket occurring in the piles due to the formation of multiple plastic hinges. In an attempt
to de-sensitise the structural response from the behaviour of the piles, the cross-section
dimensions were increased by a factor of 1.2, thus increasing the bending capacity of the
piles and preventing premature yielding of the piles away from the point of built in
restraint. This gave rise to the following cross sectional dimensions:
63
2.3 LEGS
The general layout of the structure’s elevations is illustrated in Figure A2, and provides
details of the cross-sectional dimensions of the legs. These dimensions were equal on all
four of the structure’s legs.
The leg geometry was based upon that of the baseline jacket. However, after attempting
pushover analyses on several bracing configurations it was determined that there was a
‘weak point’ in the legs. This corresponded to the point just above Level 1 where there was
a reduction in the wall thickness of the legs. At this point a plastic hinge was formed and
the analysis began to diverge. This resulted in no difference in the failure mechanisms
between different bracing configurations.
To alleviate this problem, the wall thickness of the legs between Levels 1 and 2 was
increased to the same value as that below Level 1, i.e. a 1400mm outer diameter and a wall
thickness of 65mm.
The batter applied to the structure was in line with the baseline structure and was as
follows:
The conductors were tied into their associated framing using multi-point restraints that
allowed for axial sliding of the conductor within its guide, but prevented horizontal
movement of the conductor.
The modelling of the conductors was simplified using tubular beam elements with an outer
diameter of 0.685m and a wall thickness of 0.030m.
These simplifications used to model the conductors and the interaction with the jacket
framework was justified since the sole purpose of the conductors inclusion in the model
was to transmit load back into the primary structure of the jacket and add to the stiffness of
the foundation.
2.5 LEVELS
The generic structure comprised of four levels that are referred to as:
64
The mud line frame contained no inter-frame bracing whereas the frames at Levels 1 to 3
contained the conductor framing and associated inter-frame bracing.
Figures A3 to A6 illustrate schematics of the four level frames along with details of the
members’ cross-sectional dimensions.
Table A1 details the member identifiers used in this document for the horizontal braces at
each of the above levels.
65
Table A1 Horizontal bracing members’ identifiers
Identifier Location
66
3. BRACING CONFIGURATIONS
As stated earlier, five different bracing configurations were added to the generic model to
establish their impact on the load distribution and ultimate strength of the jackets in both
the damaged and undamaged states.
Each of the bracing configurations is described in more detail in the following sections.
ratio (mm)
Table A3 below provides details of the joint group identifiers for those joint groups in the
X-braced structure that were studied in detail as part of the stress redistribution study. For
each joint group, the table identifies which members form the chord and the braces. In
addition, the index in the table’s header is a cross-reference to the joint number in the plots
of Reference 0 containing the data output from the stress redistribution study. Index ‘1’
refers to the chord and indices 2 to 7 refer to the individual joints between the chord and the
brace identified in the table.
Joint cans were added to the bracing configuration at those joints that formed the X-
bracing, i.e. joint groups MLA/B/1/2, L1A/B/1/2, L2A/B/1/2, and L3A/B/1/2. These joint
cans were approximately 2 metres long and aimed to provide localised stiffening to the
joints by increasing the wall thickness of the bracing member. They possessed the
following cross section dimensions:
Between the mud line and Level 1: 800 x 60mm
Between Level 1 and Level 2: 750 x 60mm
Between Level 2 and Level 3: 700 x 60mm
In addition, for these particular joint groups the identification of chords and braces was
somewhat different to that employed for all other joint groups. Instead, utilisation values
were calculated based on one diagonal representing the chord and the other representing the
braces, and visa-versa. These utilisation values were then compared and the worst-case
values for the chord and braces selected.
67
Table A3 X-braced structure’s joint group details
ratio (mm)
Table A5 below provides details of the joint group identifiers for those joint groups in the
diamond braced structure that were studied in detail as part of the stress redistribution
study. For each joint group, the table identifies which members form the chord and the
braces. In addition, the index in the table’s header is a cross-reference to the joint number
in the plots of Reference 0 containing the data output from the stress redistribution study.
68
Index ‘1’ refers to the chord and indices 2 to 8 refer to the individual joints between the
chord and the brace identified in the table.
69
3.3 INVERTED K-BRACED
Figure A15 and Figure A16 illustrate the bracing configuration and naming conventions for
the members on the inverted K-braced structure. The joint groups’ names and locations are
illustrated in Figure A17 and Figure A18. Table A6 details the bracing members’ cross-
sectional dimensions in terms of an outer diameter measurement and a wall thickness
measurement.
Ratio (mm)
Table A7 below provides details of the joint group identifiers for those joint groups in the
inverted K-braced structure that were studied in detail as part of the stress redistribution
study. For each joint group, the table identifies which members form the chord and the
braces. In addition, the index in the table’s header is a cross-reference to the joint number
in the plots of Reference 0 containing the data output from the stress redistribution study.
Index ‘1’ refers to the chord and indices 2 to 6 refer to the individual joints between the
chord and the brace identified in the table.
70
Table A7 Inverted K-braced structure’s joint group details
71
3.4 K-BRACED
Figure A19 and Figure A20 illustrate the bracing configuration and naming conventions for
the members on the K-braced structure. The joint groups’ names and locations are
illustrated in Figure A21 and Figure A22. Table A8 details the bracing members’ cross-
sectional dimensions in terms of an outer diameter measurement and a wall thickness
measurement.
Ratio (mm)
Table A9 below provides details of the joint group identifiers for those joint groups in the
K-braced structure that were studied in detail as part of the stress redistribution study. For
each joint group, the table identifies which members form the chord and the braces. In
addition, the index in the table’s header is a cross-reference to the joint number in the plots
of Reference 0 containing the data output from the stress redistribution study. Index ‘1’
refers to the chord and indices 2 to 6 refer to the individual joints between the chord and the
brace identified in the table.
72
Table A9 K-braced structure’s joint group details
73
Table A10 Single diagonal braced structure’s member sizes
Ratio (mm)
Table A11 below provides details of the joint group identifiers for those joint groups in the
single diagonal braced structure that were studied in detail as part of the stress redistribution
study. For each joint group, the table identifies which members form the chord and the
braces. In addition, the index in the table’s header is a cross-reference to the joint number
in the plots of Reference 0 containing the data output from the stress redistribution study.
Index ‘1’ refers to the chord and indices 2 to 7 refer to the individual joints between the
chord and the brace identified in the table.
74
4. ELEMENT FORMULATION
Each structural member in the model was modelled using two-node linear beam elements,
which are referred to as B31 elements in the ABAQUS element library. These elements are
suitable for modelling both thick members, in which shear deformation is important, and
slender beams, in which shear deformation is not important. Since the structures’ members
were classified as thin walled sections, slender elements are more applicable, thus justifying
the use of such elements. Furthermore, the use of such elements in conjunction with the
applied mesh refinement in the model was deemed to provide a reasonable compromise
between analysis run times and accuracy of results owing to the large number of runs that
have been undertaken as part of this project.
75
BLANK PAGE
76
5. MATERIAL MODEL
The material model used in the analysis is based upon a typical structural steel,
Grade 355EM, which is commonly used in the fabrication of offshore jacket
structures in the North Sea.
For the load redistribution study a linear elastic material has been used, as is the
case for the buckling analysis that feeds into the non-linear pushover analysis. The
values adopted for density, Elastic Modulus and Poisson’s Ratio are as follows:
Density: 7820kg/m3
For the non-linear pushover analysis itself an elasto-plastic model was used, as
detailed in Table A12 below. It should be noted that ABAQUS requires that the
plasticity be defined in terms of true stress and strain as opposed to the more
conventional nominal stress and strain.
355.0 0.000
461.5 0.06780
537.7 0.12744
612.3 0.21708
681.8 0.33675
709.7 0.39662
797.1 0.63620
814.9 0.69612
847.4 0.81596
890.0 0.99576
77
BLANK PAGE
78
6. LOADING
East
Northeast
North
These storm conditions comprised of a single pass of the 100 year met-ocean event wave
and the 100 year met ocean event current for the given baseline southern North Sea
location.
The current-induced load and the wave-induced load result in both a buoyancy component
and a distributed drag load. These were determined by the use of the ABAQUS AQUA
analysis tool within the ABAQUS code (Reference 2).
AQUA requires the definition of the fluid properties, i.e. the fluid density, and the
elevations of the sea-bed and the free-surface. In this study the following values were used:
79
Density: 1025.0kg/m3
Free-surface: 0.0m
The definition of the steady current vector was dependent on the storm direction, but is of a
constant magnitude for a given depth. Table A13 details the current magnitude and depth
input data applied in the model.
0.0 1.66
8.0 1.66
19.6 1.48
25.5 1.46
35.5 1.41
44.49 1.13
44.50 0.0
The wave data used in the analysis was in the form of a binary data input file. It provided
the wave surface elevations, particle velocities and accelerations, and the dynamic pressure
at points in a user-defined grid.
The use of ABAQUS AQUA enables the algorithms within the finite element code to
determine the location of members in relation to the height of the waves free surface.
Based upon this, the algorithm is able to determine whether the member contributes to the
buoyancy of the structure and whether it’s subjected to drag loading.
In calculating the loading applied to the structure, a marine growth allowance was added to
the outer diameter dimension of all members in the structure, to define the effective outer
diameter that is required in the ABAQUS AQUA analysis. The value used was 100mm,
and was based upon what can reasonably be expected to occur for a jacket located in the
southern North Sea.
In calculating the drag loading acting on a member the ABAQUS AQUA analysis
determines both the transverse drag and tangential drag. The transverse drag is attributed to
the cross-sectional resistance to fluid motion and is given by the following equation for a
particular point in the wave passage time history:
80
1
FD UC D DVn 2
2
where:
U = density of fluid
The tangential drag is attributed to the member’s skin friction, and is given by the following
equation for a particular point in the wave’s passage time history:
1
FT UCT SDV h1
2
where:
In both of the above equations the fluid particle velocity at a particular point in time is the
sum of the current and wave velocities in either the normal or tangential directions to the
given member.
81
BLANK PAGE
82
7. MODEL DEVELOPMENT
As part of the model generation phase of the project an iterative process was
adopted to sizing the members for each bracing configuration. The process is
described below and illustrated in Figure A27.
Initially the bracing members were sized based upon a slenderness ratio that was
derived from the bracing members on the baseline jacket. One of the bracing
configurations was chosen and subjected to the 100 year storm event loading
scenario from the East direction. Upon completion of the finite element analysis,
the results file, generated by ABAQUS was interrogated using bespoke post
processing subroutines to assess the joint utilisation values at each joint group, in
accordance with Reference 0 and the member utilisation values for the primary
steel work in accordance with Reference 0. Failure of the code checks (i.e. a
calculated utilisation value in excess of unity) resulted in modifications to the failed
member cross sectional dimensions, whilst maintaining symmetry, and the process
repeated until the code check was satisfied. These modifications were then carried
over to the next bracing configuration to be considered, which was then subjected
to the 100 year storm event loading scenario and to the code checking routines.
Again, failure to comply with the code checks resulted in modifications to the
members and re-analysis of the current structure and those that had previously
passed the code check. This process continued until all baseline models had
identical frame members, legs, and bracing with consistent slenderness ratios, and
that all 3 storm direction loading scenarios didn’t result in failure of either the joint
or member code checks
83
BLANK PAGE
84
8. REFERENCES
85
+21.5 m
+10 m
-8.5 m
-26 m
z North
-43.5 m East
North Storm
Northeast Storm
1 2
East Storm
86
+21500
6
5
2000
+10000
4
7826
3
2750 3250
-8500
2
-26000
1 Section details
1. 1400 x 65
2. 1400 x 85
3. 1400 x 35
4. 1400 x 75
5. 1215 x 50
-43500
6. 1030 x 60
87
27400
13700
900x35
900x35
Plan @ -43500
900x50
900x50
24500
4500
12250
900x35
900x35
4500
23518.7
10179.35 2920
700x30
800x30
900x35
20
0x
4880
65
1000x30 700x30
3120
3750
1200x60
Plan @ -26000
23736.5
700x30
800x35
950x50
3500
3120
700x30
65
0x
20
4880
900x35
800x30
700x30
3868.2
900x25 900x25
88
22537.4
11268.7 8519.4
9178.7 3910
900x50 900x25
900x25
2036.5
900x45
900x30
800x30
20
900x35
0x
3000
4880
65
1000x30 900x30
4060
3120
1200x60
700x30 700x30 Plan @ -8500
900x50
20073
3500
3750
3120
4060
900x30
65
0x
900x35
20
3000
4880
800x30
900x30
900x45
2036.5
900x25 900x25
900x50
89
13500 4000 4000
10750
900x30 900x35
70
30
4280
0x
0x
30
70
4980
20
800x25
800x35
0x
8100
65
700x30
1400
70
0x
800x35
30
16200
Plan @ +10000
1400
700x30
65
0x
800x25
800x35
20
4980
70
30
4280
0x
0x
30
70
900x30
900x35
21500
90
AU1U AU2U BU1U BU2U
Frame A Frame B
91
1UAU 1UBU 2UAU 2UBU
Frame 1 Frame 2
92
L31A L32A L31B L32B
LUA LUB
LMA LMB
LLA LLB
Frame A Frame B
93
L31A L31B L32A L32B
LU1 LU2
LM1 LM2
LL1 LL2
Frame 1 Frame 2
94
AU2U BU1U BU2U
AU1U
BM1U BM2U
AM1U AM2U
Frame A Frame B
95
1UBU 2UAU 2UBU
1UAU
2MAU 2MBU
1MAU 1MBU
Frame 1 Frame 2
96
L31A L32A L31B L32B
Frame A Frame B
Figure A13 Diamond braced structure joint group identifiers - Frames A and B
97
L31A L31B L32A L32B
Frame 1 Frame 2
Figure A14 Diamond braced structure joint group identifiers - Frames 1 and 2
98
AU1 AU2 BU1 BU2
Frame A Frame B
99
1UA 1UB 2UA 2U2
Frame 1 Frame 2
100
L31A L3A L32A L31B L3B L32B
Frame A Frame B
Figure A17 Inverted K-braced structure joint group identifiers - Frames A and B
101
L31A L31 L31B L32A L32 L32B
Frame 1 Frame 2
Figure A18 Inverted K-braced structure joint group identifiers - Frames 1 and 2
102
AU1 AU2 BU1 BU2
Frame A Frame B
103
1UA 1UB 2UA 2U2
Frame 1 Frame 2
104
L31A L32A L31B L32B
Frame A Frame B
105
L31A L31B L32A L32B
Frame 1 Frame 2
106
AU BU
BM
AM
BL
AL
Frame A Frame B
Figure A23 Single diagonal braced structure member identifiers - Frames A and B
107
1U 2U
1M 2M
1L
2L
Frame 1 Frame 2
Figure A24 Single diagonal braced structure member identifiers - Frames 1 and 2
108
L31A L32A L31B L32B
Frame A Frame B
109
L31A L31B L32A L32B
Frame 1 Frame 2
110
Define bracing slenderness ratios
<1
<1
<1
<1
<1
111
BLANK PAGE
112
APPENDIX B
113
BLANK PAGE
114
CONTENTS
Page
CONTENTS ................................................................................................. 115
1. INTRODUCTION ..................................................................................117
2. ANALYSIS APPROACH......................................................................118
2.1 UNDAMAGED STRESS STATE ...................................................................118
2.2 SEVERED MEMBER ANALYSIS ..................................................................118
2.3 POST PROCESSING......................................................................................119
3. RESULTS.............................................................................................121
3.1 GLOBAL RESPONSE ............................................................................121
3.2 LOCAL RESPONSE...............................................................................123
4. DISCUSSION .......................................................................................125
4.1 X-BRACED CONFIGURATION ..............................................................125
4.2 DIAMOND BRACED CONFIGURATION ...............................................127
4.3 INVERTED K-BRACED CONFIGURATION...........................................129
4.4 K-BRACED CONFIGURATION ..............................................................130
4.5 SINGLE DIAGONAL BRACED CONFIGURATION................................133
5. CONCLUSIONS ...................................................................................137
6. REFERENCES .....................................................................................139
List of Tables
B1 Summary of members severed
B2 Mean joint utilisation values for undamaged structure
B3 Summary of significant results from stress redistribution study
List of Figures
B1 X-braced Frame A – Member AM1U severed
B2 X-braced Frame A – Member AM1L severed
B3 X-braced Frame A – Member AL1U severed
B4 X-braced Frame A - Member AL1L severed
B5 Diamond braced Frame A – Member AL1L severed
B6 Diamond braced Frame A – Member AL1U severed
B7 Diamond braced Frame A – Member AM1L severed
B8 Inverted K Frame A – Member AM1 severed
B9 Inverted K Frame B – Member AM1 severed
B10 Inverted K Frame 1 – Member AM1 severed
B11 Inverted K Frame 2 – Member AM1 severed
115
B12 Inverted K Frame A – Member AL1 severed
B13 Inverted K Frame B – Member AL1 severed
B14 Inverted K Frame 1 – Member AL1 severed
B15 Inverted K Frame 2 – Member AL1 severed
B16 K-braced Frame A – Member AL1 severed
B17 K-braced Frame B – Member AL1 severed
B18 K-braced Frame 1 – Member AL1 severed
B19 K-braced Frame 2 – Member AL1 severed
B20 K-braced Frame A – Member AL2 severed
B21 K-braced Frame B – Member AL2 severed
B22 K-braced Frame 1 – Member AL2 severed
B23 K-braced Frame 2 – Member AL2 severed
B24 K-braced Frame A – Member AM1 severed
B25 K-braced Frame B – Member AM1 severed
B26 K-braced Frame 1 – Member AM1 severed
B27 K-braced Frame 2 – Member AM1 severed
B28 K-braced Frame A – Member AM2 severed
B29 K-braced Frame B – Member AM2 severed
B30 K-braced Frame 1 – Member AM2 severed
B31 K-braced Frame 2 – Member AM2 severed
B32 Single diagonal braced Frame A – Member AL severed
B33 Single diagonal braced Frame B – Member AL severed
B34 Single diagonal braced Frame 1 – Member AL severed
B35 Single diagonal braced Frame 2 – Member AL severed
B36 Single diagonal braced Frame A – Member AM severed
B37 Single diagonal braced Frame B – Member AM severed
B38 Single diagonal braced Frame 1 – Member AM severed
B39 Single diagonal braced Frame 2 – Member AM severed
B40 Single diagonal braced Frame A – Member BL severed
B41 Single diagonal braced Frame B – Member BL severed
B42 Single diagonal braced Frame 1 – Member BL severed
B43 Single diagonal braced Frame 2 – Member BL severed
B44 Single diagonal braced Frame A – Member BM severed
B45 Single diagonal braced Frame B – Member BM severed
B46 Single diagonal braced Frame 1 – Member BM severed
B47 Single diagonal braced Frame 2 – Member BM severed
116
1. INTRODUCTION
The Stress Redistribution Study was a comparative study to investigate the effects of bracing
configurations, and hence redundancy levels on the degree of stress redistribution that
occurred when a member was fully severed. The study aimed to establish the load
distribution, in terms of joint utilisation values, for all joints in an undamaged structure, as a
result of the structure being exposed to the 100 year storm load. The structure was then re-
analysed with a single member severed, and the redistribution of the load analysed by
reassessing the joint utilisation values. In conducting this study a total of 15 undamaged
jacket FE analyses were conducted along with 354 severed member FE analyses.
The analysis considered the three storm directions as detailed in Reference 1.
117
2. ANALYSIS APPROACH
Table B1
118
2.3 POST PROCESSING
The output from the joint code checking analyses was subjected to two levels of data
processing to establish the global response and local response of the structure in terms of the
redistribution of load throughout the structure.
y 1 ae bx
The above equation was converted into linear form by taking natural logs to give an equation
of the form:
ln Y ' c bx
where;
Y' 1 y
c ln a
The linearised equation and data were then subjected to a least squares approach to perform
the linear regression, using the ‘Gauss-Seidel’ approach to numerically solve the simultaneous
equations that were generated as part of the least squares method. The coefficients from the
simultaneous equations were then substituted into the original equation and plotted.
The plotted density functions represent the analytical solution to the differential of the
cumulative distribution function, i.e.
d d
p ( x) P( x) 1 ae bx
dx dx
where;
119
P(x) = cumulative distribution function , cdf
and is used to derive an indication of the shift in the mean joint utilisation value in the
structure as a result of a member being severed. The mean value of the PDF is calculated
using the moment generating function of the density function and is given by the following
equation;
f
tx
Mx t ³e p x dx
0
The shifts in joint utilisation values have been used to infer the redistribution of load as a
consequence of a member failing and the jacket being subjected to the 100 year storm load.
120
3. RESULTS
The results from the stress redistribution study are detailed in References 3 and 4, and are
predominantly in a graphical format. The global effects were measured in terms of a
percentage shift in the mean joint utilisation from the undamaged to the damaged case and on
whether unity was exceeded at any of the joints. Where this was the case the joint has been
identified in terms of its joint group.
Local effects were analysed in more detail to establish how individual joints were impacted
by the load redistribution at selective joint groups, and plotted as contour plots in Figure B1 to
Figure B47.
Table B2
Table B3 summarises the severed member analyses that resulted in a significant shift in the
mean joint utilisation value and those analyses that resulted in joints exceeding the code based
unity check.
121
Table B3
122
3.2 LOCAL RESPONSE
Reference 4 details the results of local effects due to the damage introduced into the jackets
and exposure to the 100 year storm event. Plots have been generated for a number of joint
groups, i.e. those located at and below Level 2 in the jackets. The study was limited to these
joint groups following an initial review of the results that highlighted above this level the
effect on joint utilisation was minimal in the majority of cases except where a member was
severed in the upper bay. For such damaged states the effect on the joint utilisation values
was concentrated about the upper bay.
As stated previously, the local response analysis focussed on the East storm direction only in
order to keep the data output and discussion to a manageable size.
123
BLANK PAGE
124
4. DISCUSSION
In general it can be seen that for the higher redundancy bracing configurations, i.e. those with
more bracing members, the global effect on the joint utilisation distribution is minimal. This
is clearly evident in Reference 3 for the diamond and X-braced configurations where the
cumulative distributions are almost identical to the damaged member cumulative
distributions, and illustrate a relatively small shift in the mean joint utilisation values between
the damaged and undamaged cases.
However, analysis of the cumulative distribution plots generated for the lower redundancy
structures, i.e. K-braced, inverted K-braced and single diagonal braced structures indicates a
different type of behaviour. These structures are affected much more by the severance of a
single member. In general, severance of a lower bay or middle bay bracing member has a
significant impact on the distribution of joint utilisation values and the potential for the code
based unity check to be exceeded. Such effects are subject to further discussion below, under
the appropriate bracing configuration sub-headings.
In addition to the global analysis performed as part of this study, data has also been generated
to investigate the local effects in more detail. Charts of joint utilisation values for individual
joint groups have been generated and are illustrated in Reference 3. These plots have been
further analysed and mapped onto the jacket structures to provide a visual ‘contour plot’ of
how joint groups throughout the structure are affected by a member being severed. These
‘contour plots’ are illustrated and discussed under the appropriate bracing configuration sub-
headings.
For the purpose of this discussion the concept of a ‘sensitivity zone’ shall be introduced. The
sensitivity zone comprises the zone in the damaged structure that is adversely affected, in
terms of a significant increase in the joint utilisation from the undamaged case, by the failure
of a member. ‘Significant’, in this context, infers an increase in excess of a 30% shift in the
joint utilisation, as calculated in accordance with Reference 2 using in-house data processing
routines.
125
group L12B, for the North storm RLS. The joint that is affected is that between Leg 2B and
the member 2LBU that lies on the opposite diagonal in the lower bay.
In general for the East storm condition, for the frames parallel to the storm direction, failure
of a lower bay diagonal member that was nominally (in the undamaged jacket) in tension,
resulted in the compressive diagonal members experiencing an increase in load. The impact
of this increase was a significant rise in joint utilisation values such that they either
approximated or exceed unity. For the North storm condition this effect was limited to Frame
2, and was attributed to the asymmetry of the structure about the storm direction’s axis owing
to the presence of the conductors. The conductors picked-up a significant amount of load
from the storm wave and as such transferred a significant proportion of this load into Frame 2.
The load was eccentric and induced a high degree of bending into Frame 2. However, for
both of these cases the effect on the overall distribution of joint utilisation values was
minimal, as can be seen from the shift in the calculated mean value in Table B3.
126
Loss of member AM1U resulted in a relaxation of the load in member AM2L that lies on the
same diagonal. However, there was a corresponding increase in the utilisation values for
members AM1L and AM2U that form the intact diagonal in the middle bay. Furthermore
there was a near doubling of the utilisation value in the horizontal member at Level 1, joint
group L12A.
Member AM1L Failure
In the case of member AM1L having failed the sensitivity zone was slightly more localised
than was the case for member AM1U having failed, and was concentrated about the middle
bay on Frame A, as illustrated in Figure B2.
Loss of member AM1L resulted in a relaxation of the load in member AM2U that lies on the
diagonal. However, there was again a corresponding increase in the utilisation values for
members AM1U and AM2L that form the intact diagonal in the middle bay, and the
horizontal members at Levels 1 and 2.
Member AL1U Failure
In the case of member AL1U having failed the sensitivity zone was localised about the lower
bay on Frame A, as illustrated in Figure B3.
The impact on the intact diagonal brace was a 50% increase in the utilisation value at the joint
between leg 2A and member AL2U, resulting in a utilisation value of 0.99. The impact on the
horizontal member’s joint with Leg 2A at Level 1 was a factor of 2 increase in the utilisation
value. At the Mud line there was an increase in the joint utilisation value at the joints
between the Leg 1A and the horizontal member by a factor of 6. Furthermore there was an
increase in the joint utilisation between the intact diagonal and Leg 1A by a factor of 1.5
resulting in a utilisation value of 0.97.
Member AL1L Failure
In the case of member AL1L having failed the sensitivity zone was again highly localised
about the lower bay horizontal members and the intact diagonal brace, as illustrated in Figure
B4.
The impact on the intact diagonal brace and the horizontal members was a 50% increase in
the utilisation value at the joint between leg 1A and member AL1U, and a factor of 4 increase
in the utilisation value of the joint between leg 1A and the horizontal member at Level 1. At
the Mud line there was an increase in the joint utilisation value at the joints between the Legs
1A and 2A, and the horizontal member by a factor of 9. However, the actual utilisation value
was less than 0.55.
127
4.2.2 Local Analysis
From an initial review of the local analysis plots documented in Reference 4 an insight into
the redistribution of load, as a result of failure of a member in Frame A, can be gained. In
general, there was very little effect on joints in Frames B, 1 and 2 as a result of a member
being severed in Frame A. This can be attributed to the structure’s ability to diffuse the load
throughout the structure using the high number of alternative load paths available at any given
joint group. This resulted in limited impact on any one particular joint and relatively low
joint utilisation values throughout the structure.
The contour plots generated from the local analysis have been limited to the following failed
member analyses for the East storm RLS:
x AM1L (nominally in tension)
x AL1U (nominally in compression)
x AL1L (nominally in tension)
The study is limited to these cases because failure of members in the upper bay had negligible
impact on joint groups below Level 2 and also the magnitude of the utilisation values above
this level were significantly less than elsewhere in the structure. Also, owing to the structural
symmetry of Frame A about its centre line it was deemed unnecessary to provide a detailed
analysis for members AM2U, AM2L, AL2U and AL2L. An initial review of the joint
utilisation plots for the joint groups analysed in Reference 4 highlighted the similarity in both
the magnitude of joint utilisation values and the percentage shift induced as a result of a
similar loaded member being severed.
A common feature of the contour plots generated, for the 3 member failure cases considered,
was the load relaxation of diagonal braces that lie on the failed member contiguous diagonals
(i.e. ‘zig-zag’), and a corresponding increase of load on the intact ‘zig-zag’. This behaviour
was comparable to the behaviour of the X-braced structure.
Failure case specific features are discussed in more detail in the following sub-sections.
Member AL1L Failure
In the case where AL1L having failed from Figure B5 it can be seen that the sensitivity zone
was very localised. In fact only one joint group was significantly affected, MLA. The
apparent increase in load through the Mud line horizontal brace can be attributed to the
localised stiffening of the joint by a joint can, thus effectively attracting load to this joint
group component, and locally relieving the load in adjacent members.
Further study of the plots in Reference 4 sheds further light on this behaviour. There was a
degree of load redistribution through the lower level joints of Frames 1 and 2. This was
notably more than was the case for the X-braced configuration, but still nowhere near the
levels observed in the lower redundancy bracing configurations.
Member AL1U Failure
In the case of member AL1U having failed the sensitivity zone was relatively small, and
tended to be local to the lower half of the middle bay close to leg 1A, as illustrated in Figure
B6.
128
Member AM1L Failure
In the case of member AM1L having failed from Figure B7 can be seen that the sensitivity
zone was very localised. Increases in joint utilisation values were limited to the diagonal
braces (AM2L and AL1U) that pass through the joint group containing the failed member and
the horizontal brace (by a factor of approximately 2) at level 1. There was also a
corresponding increase in the utilisation of leg 1A, by an approximate factor of 2, local to the
failed member.
129
x AM2 (nominally in tension)
However, owing to the similarities between the plots generated only those for the cases where
AL1 and AM1 were severed have been included.
From these plots one can determine the sensitivity zone for each failed member analysis.
Failure case specific features are discussed in detail in the following sub-sections.
Member AM1 Failure
In the case of member AM1 having failed, it can be seen, from the contour plots, Figure B8 to
B11, that the sensitivity zone was extensive. The sensitivity zone extended across all four
frames and covered the middle bay in Frames A and B, and the middle and lower bays in
frames 1 and 2 as the load was transmitted to the piles.
Loss of the load bearing capacity of AM1 resulted in a significant increase in the load through
the horizontal brace at Level 2 in Frame A, and member AM2. In fact, the utilisation of the
joint between member AM2 and the horizontal brace at Level 2 experienced a factor of
approximately 2.5 increase, and as a result exceeded unity, hence highlighting the potential
cascade failure of this joint. In addition there was a load increase at the joint between BM1
and L2HB, in Frame B. Here the compressive load on BM1 increased, and the utilisation of
the joint increased by approximately 50% to a utilisation of unity. This again highlighted the
potential for a cascade failure.
Member AM2 Failure
The general behaviour observed as a result of member AM2 having failed was comparable to
that for the case of member AM1 having failed. This is evident from the relevant plots in
Reference 3.
Member AL1 Failure
In the case of member AL1 having failed, it can be seen from Figure B12 to B15 that the
sensitivity zone was extensive. It extended across all four frames and covered the middle bay
in Frame A, the lower bay in Frame B, and the middle and lower bays in Frames 1 and 2 as
the load was transmitted to the piles.
In Frame A, failure of member AL1 resulted in a relaxation of the load in member AM2, with
the load being redistributed through the Mud line horizontal member and the Level 1
horizontal member.
In Frame B the effects were limited to the lower bay as the structure attempted to
accommodate the asymmetric stiffness as a result of the severed member in Frame A’s lower
bay. The resultant torsional effects due to the asymmetric stiffness was reacted in Frames 1
and 2 where both the middle and lower bay joints were affected by a significant increase in
joint utilisation.
Throughout the structure the effects were diffused beyond level 2 where there was limited
impact.
Member AL2 Failure
The general behaviour observed as a result of member AL2 having failed was comparable to
that for the case of member AL1 having failed. This is evident from the relevant plots in
Reference 3.
130
appreciable shift in the distribution of joint utilisation values. Failure of a middle bay member
however imparted a greater overall effect, whilst the failure of a lower bay brace affected a
minority of joints.
For the North storm load case, failure of any middle or upper bay diagonal brace on Frame 2
had an appreciable impact on the joint utilisation distribution. Very high utilisation values
were observed at joint group L12. As was the case for the inverted K-braced structure, such
increases can be attributed to the combination of the reduced stiffness of the middle bay due
to member failure and the significant eccentric loading imparted on Frame 2 by the
conductors. Failure of an upper bay diagonal brace also resulted in joint utilisation values
exceeding unity, but such joints were limited to the plan bracing at Level 3. Due to the
reduced stiffness of the upper bay, the load increased on the plan bracing as the structure
attempted to accommodate the resultant asymmetric stiffness.
Failure of a middle bay bracing member on Frame 1 also had an appreciable effect on the
distribution of joint utilisation values for the North Storm condition. However, the impact
was not as severe as that for failure of a corresponding member in Frame 2, but it still resulted
in unity being exceeded at either joint group L11B or L11A.
For the Northeast storm load case failure of a middle bay member in either Frames A or 2
produced an appreciable shift in the distribution of joint utilisation values. In such cases unity
was exceeded at either joint group L11A, L12A or L12B.
In general the distribution of joint utilisation values and hence the inferred redistribution of
the load within the K- braced jacket structure as the result a failed member, appeared to be
most sensitive to the failure of a middle bay brace. Unlike the higher redundancy structures
there was a considerable difference in stiffness between the middle and lower bays in the K-
braced structure due to the added bending restraint provided by the piles interaction with the
legs in the lower half of the lower bay. Thus, as a result of a failed member in the lower bay,
bending and the induced torsion was resisted by the legs and load gets transferred axially
through the legs to the piles. In the event of a middle bay member failing, there was a
significant reduction in the stiffness of the middle bay and induced torsional effects. The load
was redistributed throughout the structure as the structure accommodated the load from the
failed member. Since, locally, the legs do not provide the same level of restraint as they do in
the lower bay, the load was redistributed throughout the structure, the impact being a general
increase in joint utilisation values.
131
Member AL1 Failure
In the case of member AL1 having failed, it can be seen from Figure B16 to B19 that the
sensitivity zone was extensive. Load was redistributed throughout the structure as the
structure accommodated the change in stiffness of Frame A. The sensitivity zone extended
throughout the lower and middle bays of Frames 1 and 2 and into the horizontal member at
Level 1 of Frame B. The effect on Frame A was limited to the Mud line horizontal brace.
Throughout Frame A, there was a limited effect on the utilisation values of joints, particularly
in the diagonal bracing members’ joints. The intact lower bay member, AL2, endured little
change as a result of AL1 being severed. This behaviour can be attributed to the local
stiffening of the lower bay by the piles. The piles provide additional bending restraint to the
lower bay due to the nature in which they are tied into the structure and the increase in the
effective cross-sectional area that they contribute to the lower proportion of the leg. Instead
the load was redistributed to the upper proportion of the legs and the horizontal bracing at the
Mud line and Level 1. At the Mud line, the horizontal braces’ joint with Leg 1A experienced
a utilisation value that exceeded unity.
The frames that are perpendicular to the storm loading experienced a considerable increase in
load throughout the middle and lower bays as the structure accommodated the induced torsion
attributable to the asymmetrical stiffness between Frames A and B. The load was generally
diffused throughout the middle and lower bays’ diagonal and horizontal members.
The effect on Frame B was a general increase in joint utilisation values; however, this was
limited with the exception of the horizontal member at Level 1.
Member AL2 Failure
The general behaviour of the structure upon failure of member AL2 was similar to that
exhibited when member AL1 was severed (see Figure B20 to B23). The general load
redistribution was comparable.
Member AM1 Failure
In the case of member AM1 having failed, it can be seen from Figures B24 to B27 that the
sensitivity zone was extensive. Load was redistributed into frame B’s middle and upper bays
through the diagonal and horizontal braces in Frames 1 and 2. The sensitivity zone extended
across all four frames and covered the middle bay in Frames A and B, and all three bays in
frames 1 and 2 as the load was redistributed and transmitted to the piles.
In general the legs in the lower half of the lower bay were shielded from the load by the piles
and as such their interface with the Mud line framing endured limited impacted by member
failure.
Loss of the load bearing capacity of AM1 resulted in a significant increase in the load through
the horizontal brace at Level 1 in Frame A. In fact the utilisation of the horizontal brace’s
joints at Level 1 experienced a factor of approximately 4 increase at joint group L11A, a
factor of approximately 2 increase at joint group L1A and a factor of approximately 2.5
increase at joint group L12A. As a result of these increases the code based unity check was
exceeded, hence highlighting the potential cascade failure of these joints.
As a result of the imposed asymmetric stiffness between Frames A and B, load was
redistributed into the perpendicular frames, i.e. 1 and 2, as the structure accommodated the
induced torsion. The increased load in these frames was diffused throughout the three bays.
In general there was an increase by a factor of 2 in the joint utilisation values throughout the
joints in Frames 1 and 2.
The effect on Frame B was again an overall increase in joint utilisation values, with the
middle and upper bays more adversely affected. Although absolute values tended to be
higher in Frame B than in Frames 1 and 2, the percentage increase was a lot less severe.
132
Member AM2 Failure
The general behaviour of the structure upon failure of member AM2 was similar to that
exhibited when member AL1 was severed (see Figures B28 to B31). The general load
redistribution was comparable, and for this particular case, joint groups L12A and L1A
exceeded the code based unity check.
133
Member AL Failure
In the case of member AL having failed, it can be seen from Figures B32 to B35 that the
effect on the individual joint utilisation values was extensive. Significant increases were
observed throughout the structure. The sensitivity zone can be seen to extend across of four
frames and generally covers both the lower and middle bays. The impact on the members in
the upper bay was limited.
In Frame A’s lower bay there was a general relaxation in the joint utilisation values due to the
failed member. However, there was an increase at Level 1, particularly in the legs 1A and
2A, and the horizontal brace (albeit to a lesser extent). Throughout Frame A, there was a
general trend of the load increasing in the legs and very little effect on the braces. This
behaviour can be attributed to the increased compliance of Frame A provided by the resultant
reduction in stiffness of the lower bay.
Within Frame B there was a general increase in utilisation of the joints as the structure
accommodated the reduction in stiffness in the storm direction.
Frames 1 and 2 experienced a fairly extensive increase in joint utilisation values within the
lower and middle bays as a result of the induced torsion in the structure as a consequence of
the asymmetric stiffness between Frames A and B. The torsion was reacted by the diagonal
bracing members and the horizontal members at Level 1.
A review of the plots in Reference 4 highlights that the absolute joint utilisation values were
in general not as severe as the case for the failure of a middle bay brace.
Member AM Failure
In the case of member AM having failed, it can be seen from Figures B36 to B39 that the
effect on individual joint utilisation values was extensive. The sensitivity zone extended
across all four frames and covered both the lower and middle bays of the jacket and extended
into the upper bay. However, the absolute values of joint utilisation for joints at Level 2 and
above were much less than joints at Level 1.
In Frame A, failure of member AM resulted in a significant rise in the load on the horizontal
bracing members at Levels 1 and 2. In particular at Level 1 the increase in utilisation between
the horizontal bracing member and leg 2A increased by a factor of approximately 4, resulting
in the joint utilisation exceeding the code based unity check, thus highlighting a potential
cascade failure of this joint. Furthermore a similar increase was observed at this members
joint with Leg 1A, however in this case the code based unity check was not exceeded.
Within Frame A the failure of the member was accommodated by the legs 1A and 2A, which
both experienced a significant rise in utilisation, with leg 2A (the east most leg) enduring the
highest rise; by approximately a factor of 3 on the undamaged case.
As a result of the imposed asymmetric stiffness between Frames A and B there was a
significant increase in load in the members of Frame B as well as in Frames 1 and 2. The
joint utilisation values in Frame B generally increased throughout the three bays, with the
middle bay being the most adversely effected. However absolute values tended to be limited
to less than 0.6, and shifts, with the exception of legs 1B and 2B, limited to approximately
50%.
In Frames 1 and 2, as stated above there was also a significant shift in joint utilisation values
as these frames reacted the induced torsion as a result of the imposed asymmetry between the
stiffness of Frames A and B. The induced torsion of the jacket structure was reacted by the
horizontal and diagonal braces.
Member BL Failure
In the case of member BL having failed, it can again be seen from Figures B40 to B43 that the
effect on individual joint utilisation values was extensive. However, the general behaviour
was comparable to the case where member AL was severed.
134
Member BM Failure
In the case of member BM having failed, it can again be seen Figures B44 to B47 that the
effect on individual joint utilisation values was extensive. The general behaviour was
comparable to the analysis performed for case where member AM was severed, in terms of
the sensitivity zone.
However, a more detailed review of absolute joint utilisation values from the plots in
Reference 4 reveals a significant impact on utilisation values of joints in Frame B, in
particular the joint between the horizontal brace at level 1 and leg 2B. Here the joint
experienced an increase in utilisation by a factor of approximately 5, resulting in the joint
exceeding the code based unity check. This highlighted the potential for a cascade failure of
this joint.
135
BLANK PAGE
136
5. CONCLUSIONS
x The X-braced and the diamond braced structures are able to accommodate member
failures much more economically than the inverted K-braced, K-braced, and single
diagonal braced structures. This behaviour is in-line with perceived redundancy of the
five bracing configurations.
x For the leaner structures, failure of a middle bay diagonal brace had the largest impact on
structural stiffness and joint utilisation values. In general, the joints at Level 1 exhibited
higher utilisation values than other joints in the structure, as the induced bending was
accommodated.
x For the higher redundancy structures, the impact of a failed member was generally not as
onerous as the case for the leaner structures. However severance of a lower bay member
had a significant impact locally on joint utilisation values.
x The difference in the global response between the X-braced and diamond braced
structures’ response was attributed to the resultant load paths when a member was
severed. Failure of a diagonal bracing member in the X-braced structure resulted in
almost a total loss of the corresponding diagonal’s ability to bear load, thus in effect two
bracing members were lost in a single bay. However, in the case of the diamond braced
structure, diagonals were divided between two bays, and as such the effect on a single
bay’s stiffness was not as severe.
137
BLANK PAGE
138
6. REFERENCES
1 Stress Redistribution in Platform Substructures Due to Primary Member Damage and its
Effect on Structural Reliability – EQE Report N° 45-20-R-01 Draft – 19th January 2001 –
Appendix A – Model Description
2 Offshore Installations: Guidance on Design, Construction and Certification – Fourth
Edition-1990, HMSO – Appendix A21
3 Stress Redistribution in Platform Substructures Due to Primary Member Damage and its
Effect on Structural Reliability – EQE Report N° 45-20-R-01 Draft – 19th January 2001 –
Appendix C – Joint Utilisation Distribution Plots
4 Stress Redistribution in Platform Substructures Due to Primary Member Damage and its
Effect on Structural Reliability – EQE Report N° 45-20-R-01 Draft – 19th January 2001 –
Appendix D – Joint Group Utilisation Plots
139
BLANK PAGE
140
APPENDIX C
141
BLANK PAGE
142
CONTENTS
Page
1. INTRODUCTION ...................................................................................145
2. REFERENCES ......................................................................................145
143
BLANK PAGE
144
1. INTRODUCTION
This appendix provides the results from the global analysis conducted as part of the Stress
Redistribution Study described in Reference 1. The data presented here takes the form of
cumulative joint utilisation value distribution plots and probability density functions for each
of the severed member cases considered. Reference 1 provides details of the analysis
conducted to generate these plots along with a summary of the severed member cases
considered.
2. REFERENCES
1 Stress Redistribution in Platform Substructures Due to Primary Member Damage and its
Effect on Structural Reliability – EQE Report N° 45-20-R-01 Draft – 19th January 2001 –
Appendix B – Stress Redistribution Study
145
BLANK PAGE
146
APPENDIX D
147
BLANK PAGE
148
CONTENTS
Page
1. INTRODUCTION................................................................................150
2. INTERPRETATION OF PLOTS.........................................................150
3. REFERENCES...................................................................................150
149
1. INTRODUCTION
This appendix provides the results from the local analysis conducted as part of the Stress
Redistribution Study described in Reference 1. The data presented here takes the form of
joint utilisation values for a number of joint groups for each of the severed member cases
considered. Reference 1 provides details of the analysis conducted to generate these plots
along with a summary of the severed member cases considered.
2. INTERPRETATION OF PLOTS
Detail joint group utilisation plots are provided in this appendix for the east storm load case,
for those joint groups, which were located below Level 2 in the structures. The plots detail
the utilisation values, calculated in accordance with Reference 2 for the chord and each
member that intersects with the chord to form a joint. The x-axis index should be interpreted
as follows: Index ‘1’ refers to the joint group’s chord and indices 2 plus refer to the individual
joints between the chord and the braces. For those joint groups that were considered in detail
in the stress redistribution study, the brace member that forms the joint can be determined
from the tables in Reference 3.
3. REFERENCES
1 Stress Redistribution in Platform Substructures Due to Primary Member Damage and its
Effect on Structural Reliability – EQE Report N° 45-20-R-01 Draft – 19th January 2001 –
Appendix B – Stress Redistribution Study
2 Offshore Installations: Guidance on Design, Construction and Certification, Fourth
Edition – 1990, HMSO – Appendix A21 Steel – Joint Design for Welded Tubular Steel
Structures.
3 Stress Redistribution in Platform Substructures Due to Primary Member Damage and its
Effect on Structural Reliability – EQE Report N° 45-20-R-01 Draft – 19th January 2001 –
Appendix A – Model Description.
150
BLANK PAGE
151
BLANK PAGE
152
APPENDIX E
153
BLANK PAGE
154
CONTENTS
Page
1. INTRODUCTION ....................................................................................159
6. REFERENCES .......................................................................................181
List of Tables
E1 Summary of severed members
E2 Undamaged jackets ultimate strength results
E3 X-braced structure ultimate strength results
E4 Diamond braced structure ultimate strength results
E5 Inverted K-braced structure ultimate strength results
E6 K-brace structure ultimate strength results
E7 Single diagonal braced structure ultimate strength results
E8 Multiple member failed ultimate strength results
E9 X-braced jacket single severed member study
E10 Diamond braced structure single severed member study
E11 Inverted K-braced structure single severed member study
E12 K-braced structure single severed member study
E13 Single diagonal braced structure single severed member study
155
List of Figures
E1 Plot of calculate RSR for the 5 bracing configurations for both damaged and
undamaged states
E2 Plot of calculate RRF for the 5 bracing configurations for both damaged and
undamaged states
E3 Undamaged jackets ultimate strength study
E4 X-braced structure – undamaged state – displaced shape plot
E5 Diamond braced structure – undamaged state – displaced shape plot
E6 Inverted K-braced structure – undamaged state – displaced shape plot
E7 K-braced structure – undamaged state – displaced shape plot
E8 Single diagonal braced structure – undamaged state – displaced shape plot
E9 X-braced structure – pushover curves
E10 Diamond braced structure – pushover curves
E11 Inverted K-braced structure – pushover curves
E12 K-braced structure – pushover curves
E13 Single diagonal braced structure – pushover curves
E14 X-braced structure – damaged state AL1L – displaced shape plot
E15 X-braced structure – damaged state AL1U – displaced shape plot
E16 X-braced structure – damaged state AM1L – displaced shape plot
E17 X-braced structure – damaged state AM1U – displaced shape plot
E18 Diamond braced structure – damaged state AL1L – displaced shape plot
E19 Diamond braced structure – damaged state AL1U – displaced shape plot
E20 Diamond braced structure – damaged state AM1L – displaced shape plot
E21 Diamond braced structure – damaged state AM1U – displaced shape plot
E22 Inverted K-braced structure – damaged state AL1 – displaced shape plot
E23 Inverted K-braced structure – damaged state AL2 – displaced shape plot
E24 Inverted K-braced structure – damaged state AM1 – displaced shape plot
E25 Inverted K-braced structure – damaged state AM2 – displaced shape plot
E26 Inverted K-braced structure – damaged state AU1 – displaced shape plot
E27 K-braced structure – damaged state AL1 – displaced shape plot
E28 K-braced structure – damaged state AL2 – displaced shape plot
E29 K-braced structure – damaged state AM1 – displaced shape plot
E30 K-braced structure – damaged state AM2 – displaced shape plot
E31 K-braced structure – damaged state AU2 – displaced shape plot
E32 K-braced structure – damaged state AU2 – plastic strain plot
E33 Single diagonal braced structure – damaged state AL– displaced shape plot
E34 Single diagonal braced structure – damaged state AL – plastic strain plot
E35 Single diagonal braced structure – damaged state AM – displaced shape plot
156
E36 Single diagonal braced structure – damaged state AU - displaced shape plot
E37 Single diagonal braced structure – damaged state BL - displaced shape plot
E38 Single diagonal braced structure – damaged state BL – plastic strain plot
E39 Single diagonal braced structure – damaged state BM - displaced shape plot
E40 Single diagonal braced structure – damaged state BM – plastic strain plot
E41 Single Diagonal Braced Structure – Damaged State BU - Displaced Shape Plot
E42 Inverted K-Braced Structure – Multiple-Member Severed Pushover Curves
E43 Inverted K-Braced Structure – Multiple-Member Severed Displaced Shape Plot
E44 X-Braced Structure – Multiple-Member Severed Pushover Curves
E45 X-Braced Structure – Multiple-Member Severed Displaced Shape Plot
157
BLANK PAGE
158
1. INTRODUCTION
Each of the five bracing configurations, described in Reference 1 was subjected to a series
of static non-linear, pushover analyses, in both the damaged and undamaged states, for an
East storm load case. The purpose of the study was to establish the ultimate strength of the
jackets in their undamaged states and to assess the impact on the strength when the
structures contained at least one severed member. This study aimed to establish a member
criticality profile for each bracing configuration to feed into the structural reliability
assessment for each of the jacket types.
Using the results from the single member analyses and the stress re-distribution
investigations a limited study was conducted to establish the impact on the structures’
ultimate strength as a result of two members having failed. The selection process for such
members is the subject of further discussion in this appendix.
159
BLANK PAGE
160
2. ANALYSIS APPROACH
2.1 GENERAL
The model was initially pre-stressed with gravity and buoyancy loads, and a *BUCKLE
analysis was performed on the structure based on the 100 year RLS. The *BUCKLE analysis
within ABAQUS (Reference 2) provides an estimate of the buckling mode shapes for the
structure.
The output from the buckling analysis was used to introduce imperfections into the model for
the ultimate strength analysis. The imperfections consisted of multiple superimposed
buckling modes about the pre-stressed state, and applied in the form of initial imperfections to
the model in the unstressed condition. The structural response was considered to be
sufficiently linear under gravity and buoyancy loads and therefore the principle of
superimposition remained valid.
The ultimate strength analysis was then performed utilising the ‘Riks method’ within
ABAQUS. This is the subject of further discussion below.
‘O’ is the ‘load proportionality factor’, LPF, and it is this value which is solved for using the
simultaneous equations to calculate the load and displacement.
For the ultimate strength analysis conducted as part of this study automatic incrementation
was used to control the analysis. However, success of the analysis is dependent upon the user
defined limits on increment size, and as a result of this a degree of fine tuning was required in
order to achieve successful results.
Termination of the analysis is defined by the user and takes the form of a user defined,
maximum value of the load proportionality factor, or a maximum displacement at a specified
degree of freedom. The value of LPFmax utilised in this study was 3.0 and a maximum
displacement of the topsides of 3.0m was defined.
161
2.3 SEVERED MEMBERS
Table E1 details those members that were severed for each of the bracing configurations for
the East storm load scenario. The member identifiers are taken from Reference 1.
The same approach to severing a member as detailed in Reference 4 was adopted for these
analyses.
162
3. RESULTS
The results from the undamaged jackets’ ultimate strength study have been reported in the
form of a ‘Reserve Strength Ration’, RSR. The RSR is defined as the ratio of ultimate
strength to design load. The design load is equivalent to the 100 year storm event load, which
is equal to the RLS. Therefore the RSR is equal to the LPF that is output from the FE runs.
The results from the damaged jacket analyses have been reported in the form of an RSR and a
‘Residual Resistance Factor’, RRF. The RRF is defined as the ratio of the damaged jacket’s
ultimate strength to that of the undamaged jacket’s ultimate strength. The RRF provides an
indication of the robustness of the jacket to damage. An RRF of 1 indicates that the severed
member is fully redundant, whereas an RRF of 0 indicates that there is no redundancy in the
structure.
X 2.51
Diamond 2.23
Inverted K 2.07
K 2.27
Single diagonal 2.43
Table E3 to Table E7 detail the results from the ultimate strength analysis in terms of the
Reserve Strength Ration, RSR, and the Residual Resistance Factor, RRF, for all five bracing
configurations in the damaged state.
Severed Member
AL1L AL1U AM1L AM1U
Member Type LC LT MC MT
RSR 2.32 2.22 2.49 2.53
RRF 0.924 0.884 0.992 1.008
163
Table E4 Diamond braced structure ultimate strength results
Severed Member
AL1L AL1U AM1L AM1U
Member Type LT LC MT MC
RSR 1.96 2.06 1.93 2.20
RRF 0.879 0.924 0.865 0.986
Severed Member
AL1 AL2 AM1 AM2 AU1
Member LC LT MC MT UC
Type
RSR 1.65 1.65 1.79 1.81 2.01
RRF 0.797 0.797 0.865 0.874 0.971
Severed Member
AL1 AL2 AM1 AM2 AU1
Member LT LC MT MC UT
Type
RSR 1.86 1.85 1.85 1.88 2.33
RRF 0.819 0.815 0.815 0.828 1.026
Severed Member
AL AM AU BL BM BU
Member LT MC UT LC MT UC
Type
RSR 1.94 2.08 2.45 2.16 2.27 2.44
RRF 0.798 0.856 1.008 0.889 0.934 1.004
Figure E1 illustrates graphically the RSRs for each bracing configuration in both the
undamaged and damaged states. The plot identifies which member was severed in terms of
whether the member was nominally in tension or compression and in which bay of the
structure the member was located as detailed in Table E3 to Table E7.
164
3.2 MULTIPLE-MEMBER FAILED ULTIMATE STRENGTH STUDY
Table E8 summarises the results from the multiple-member failed study conducted on a
higher and lower redundancy structure.
165
BLANK PAGE
166
4. DISCUSSIONS
As with the stress redistribution study conducted previously, the purpose of the ultimate
strength study was to assess the relative impact on ultimate strength as a result of damage to
structures of five different bracing configurations. This discussion focuses on the relative
behaviour of the structures as opposed to the absolute strength.
167
For the X-braced structure there were 2 load paths parallel to the storm direction at each of
the joint groups on grid line 2 that reacted the compressive load applied to the structure.
Figure E4 illustrates the high stiffness of the X-braced structure thus there was very little
bending response of the structure to the applied load (magnification factor on plot is 20). The
impact was critical buckling loads were maximised and individual member axial loads were
minimised owing to the presence of multiple load path, resulting in high ultimate strength.
However, for the inverted K-braced structure there was only one load path at each joint group
on grid line 2 that reacted the compressive load induced in the structure. This, combined with
the reduced stiffness of the structure as depicted in Figure E6 had the effect of minimising the
critical buckling load and maximising the individual member axial loads, resulting in a
relatively low ultimate strength.
The single diagonal braced structure possessed the second highest ultimate strength in the
undamaged state, with failure being defined as buckling of the lower bay compression
member, located in Frame B at joint group L12B. Figure E3 illustrates the reduced structural
stiffness of the single braced structure in comparison with the X braced structure. From
Figure E8 this reduction in stiffness was observed as an increased displacement of the
structure, both in and out of plane. The impact of this was increased loading on the lower bay
compression member due to both bending and shear resulting in buckling under a reduced
applied load to that of the X braced structure.
For the K-braced there were again two 2 load paths parallel to the storm direction at each of
the joint groups on grid line 2 that reacted the compressive load applied to the structure.
However, Figure E3 illustrates that the structure’s stiffness was significantly less than that of
the X braced structure, and that of the other bracing configurations. From Figure E7 this
reduction in stiffness resulted in a much greater structural response for the K-braced structure
in comparison to the X-braced structure. The increased levels of bending and shear observed
in Figure E7 resulted in higher bending moments and axial loads in the lower bay bracing for
a given applied load compared to the X braced structure. The impact of this was observed as
a reduction in the ultimate strength of the jacket in comparison to the X-braced structure.
However the structure out performed the diamond and inverted K-braced structures owing to
the presence of multiple load paths at Level 1, to react the compressive load.
The diamond braced structure provided the minimum number of load paths parallel to the
storm direction at each of the joint groups on grid line 2. However the bracing configuration
provided multiple restraints throughout the height of the structure, thus preventing bending of
the legs. As a result the structure is much stiffer and the step change in stiffness about Level
1 is reduced. The impact of this was that the global response as seen in Figure E5 was
predominantly shear of the structure. The shear manifested itself as an axial compressive load
in the lowest compression members of Frames A and B, resulting in the critical buckling
mode being reached at a lower LPF than in the case of the X, single diagonal and K braced
structures.
168
For the K-braced structure it is evident that loss of any bracing member below Level 2 in the
structure has a profound impact on RSR, thus highlighting the sensitivity of this bracing
configuration to a severed member.
169
Table E9 to Table E13 summarise the behaviour of each bracing configuration when a single
member was severed.
Figure E9 to Figure E13 illustrate the pushover curves for each of the jacket configurations.
170
Table E9 X-braced structure single severed member study
171
Table E10 Diamond braced structure single severed member study
172
Table E11 Inverted K-braced structure single severed member study
173
Table E12 K-braced structure single severed member study
174
Member Bay / RSR RRF Displaced Shape Comments
Severed Nominal Plot /
Load Case
Peak equivalent
Plastic Strain Plot
(if applicable)
AU1 Upper 2.01 1.026 Figure E32 Ductile failure – high plasticity
in legs between top of piles and
Tension
Level 1
Structural response – bending
about top of piles, and twisting
about vertical axis.
Degree of twist decreased
towards piles – where restraint
on legs increased
Localised yielding of legs A1
and B1 between piles and
Level 1.
175
Table E13 Single diagonal braced structure single severed member study
176
Member Bay / RS RRF Displaced Comments
Severed Nominal R Shape Plot
Load Case
Peeq Plot (if
applicable)
BM Middle 2.27 0.934 Figure E39 Ductile failure
Figure E40
Tension High degree of torsion about
vertical axis
SRS – significant increase in
load acting on legs local to
Level 1.
High degrees of plasticity in
legs local to piles and Level
1due to reaction of twist.
BU Upper 2.44 1.004 Figure E41 First buckle – member BL
Compression Twisting of structure about
vertical axis.
Redistribution of load to
Frames 1 and 2
‘Shielding’ of members BL
and AL – increase in RSR
177
4.3 MULTIPLE MEMBER SEVERED PUSHOVERS
Based upon the results from the single severed member ultimate strength study it was decided
to limit the dual member study to the X braced structure and the inverted K-braced structure,
since these two structures yielded the two bounding RSRs in the ultimate strength study. The
purpose of limiting the scope of the study was to facilitate the identification of differences in
the response between the higher and lower redundancy structures.
178
5. CONCLUSIONS
In the undamaged states the five bracing configurations can be ranked in descending order
according to the RSRs calculated for the East storm load case;
x X
x Single diagonal
x K
x Diamond
x Inverted K
It is considered that this ranking can be attributed to the variation in the ‘step’ change in
stiffness between the lower and middle bays. The magnitude of this step is determined by the
number of load paths available, local to Level 1, to react the resultant compressive load
induced in the structure. The more load paths available, the lower the axial compressive load
in a given member, therefore there is a rise in the calculated RSR. Furthermore, the presence
of more load paths also has the effect of reducing the bending of the structure and as such the
end moments acting on members is limited. The effect of this is to limit the reduction in the
critical buckling load of a particular member.
From the single member severed study conducted, it is evident that there are two distinct
types of behaviour. As was the case in the stress redistribution study undertaken, the X
braced and the diamond braced structures were able to accommodate member failures much
more economically than the lower redundancy structures, i.e. inverted K-braced, K-braced,
and single diagonal braced structures. This behaviour was in-line with perceived redundancy
of the five bracing configurations, and is illustrated in Figure E1 by the difference in the range
of RSRs calculated for each of the bracing configurations.
Severance of a member in either the middle or lower bays of the lower redundancy structures
introduced twisting into the structures and resulted in an increase in load on the lower
members thus initiating buckling of such members at lower values of LPF, resulting in
reduced RSRs. Furthermore, in most cases the legs at the back of the structure, i.e. gridline 1
experienced plastic strains local to the top of the piles.
Severance of an upper bay member, in the lower redundancy structures, generally resulted in
an increase in RSR. Such effects were attributed to the induced torsion in the jackets and the
impact that this has on the load distribution in the lower bay. For such damaged states the
load is distributed to the perpendicular frames as they react rotation of the legs, and thus
alleviate the load on the lower compression members in the frames parallel to the storm
direction.
The K-braced structure was found to be the least tolerant to a severed member. Regardless of
which member was severed in either the lower or middle bays, the impact was a significant
reduction in the calculated ultimate strength.
The dual member severed study further highlighted the difference between the lower and
higher redundancy structures. Severance of two members on the inverted K braced structure
had a significant impact on ultimate strength, resulting in a 40% reduction, whereas that
performed on the X braced structure resulted in a 20% reduction.
179
BLANK PAGE
180
6. REFERENCES
1 Stress Redistribution in Platform Substructures Due to Primary Member Damage and its
Effect on Structural Reliability – EQE Report N° 45-20-R-01 Draft – 19th January 2001 –
Appendix A – Model Description
2 ABAQUS 5.8 – Hibbitt, Karlsson & Sorensen, Inc.
3 ULTIGUIDE – Best Practice Guidelines for Use of Non-linear Analysis Methods in
Documentation of Ultimate Limit States for Jacket Type Offshore Structures – April 1999
4 Stress Redistribution in Platform Substructures Due to Primary Member Damage and its
Effect on Structural Reliability – EQE Report N° 45-20-R-01 Draft – 19th January 2001 –
Appendix B – Stress Redistribution Study
181
BLANK PAGE
182
Printed and published by the Health and Safety Executive
C30 1/98
Printed and published by the Health and Safety Executive
C0.06 07/04
ISBN 0-7176-2870-1
RR 245