A B C D E F

2'-6" 15' 5'-9" 5' 5'-6" 3'-9" 2'-6"

2' RETAINING WALL 2'


3'

1
2'

2'
C1
6" C2 6"
RETAINING WALL

RETAINING WALL
17'

2' 2'
2
2'

2'
6" C3 6"
C4
11'-6"

2' 2'
3
2'

2'
6" C5 6"
C6
RETAINING WALL

RETAINING WALL
14'-5"

3" 3"
1'-6" 1'-6"
1'-6"
3"

3"

4
2'

2'

C8
1'-6"

C7 C9
1'-6"

1'-6"
5'

1'-6" RETAINING WALL

6" 6"
RETAINING WALL

RETAINING WALL

5 C10 C11
RETAINING WALL
4'-4"

6" 6"
C13
6
1'-6"

1'-6"

C12
1'-6"

1'-6"
4'

1' 1' 1'


7
3" 2'-6"

C14 RETAINING WALL C15 RETAINING WALL C16


8

LAYOUT OF COLUMNS
NOTE:
1) ALL COLUMNS ARE CENTRALLY PLACED ALONG THE GRID LINES UNLESS NOTED
OTHERWISE (UNO)
2) IF THIS DIMENSION IS NOT ACHIEVED AT SITE, THE DISCREPANCY SHALL BE BROUGHT TO
THE NOTICE OF THE ENGINEER AND ARCHITECT ABHYYUDAYA
STRUCTURAL CONSULTANTS

#1553, 5th Block Sir M Vishweshwaraiah Layout Bengalure-560056


Email: abhyudayastr@gmail.com
Mobile:+91-9036430036

ST-LK77-FD-01 A2 R0

GOOD FOR CONSTRUCTION LK77 31.03.2023 1" = 72"


A B C D E F
2'-6" 15' 5'-9" 5' 5'-6" 3'-9" 2'-6"
3'

3'

4'
1

8'-9"
C1
C2

5'-9"
8'-9"
2'-3"
6'
Y10-8"C/C.
8'-6" 8'-6"
AT MID SPAN
17'

4' 4'
10' 10'
5'-3"

5'-3"
10'-6"

10'-6"
2 GRADE SLAB
C3 5" THK. C4

7'-6" 3'-9"
11'-6"

10'
5'-3"

10'-6"

10'-6"

3
C5

5'-3"
CLOUDED FOOTING AND RETAINING C6
7'-6" WALL TO TAKEN TILL LIFT PIT LEVEL 3'-9"
(REFER SECTION 1-1)
14'-5"

10' 4'
4'
10'-9"
7'-9" 7'
2"

2"
4'-71
4'-3"

4'-11
9'-3"

7'-9"
8'-6"

4
C8 C9
C7 1'-6" 4'-6"
5'

5'-3" 5'-41
2"
5
1'-9"

4' C10 C11


4'-4"

8'-1"

6' 7'
C12 C13 2'-6"
6 2'-3"
2'

1'-6"
3'-9"
5'
4'

2'-6"

7'-9"

6'-6"

8'-6"
5'-3"

7
4'

4'
3" 2'-6"

C14 C15 3'-6" C16


8
4'-6" RET. WALL STOPS AT RAMP LEVEL 5'-3"
AND RAMP GRADE SLAB SHALL
CONNECTING INTO RET. WALL

LAYOUT OF FOOTINGS
1) FOUNDING LEVEL = 10'-0" BELOW NATURAL GROUND LEVEL (NGL)
2) ALL FOOTINGS ARE PLACED SUCH THAT THE CENTER OF FOOTING MATCHES WITH THE
COLUMN CENTER UNO

ABHYYUDAYA
STRUCTURAL CONSULTANTS

#1553, 5th Block Sir M Vishweshwaraiah Layout Bengalure-560056


Email: abhyudayastr@gmail.com
Mobile:+91-9036430036

ST-LK77-FD-02 A2 R0

GOOD FOR CONSTRUCTION LK77 31.03.2023 1" = 72"


A 2 B C D E F
2'-6" 15' 5'-9" 5' 5'-6" 3'-9" 2'-6"
3'

SEC 3-3
SEC 3-3
1
C1
C2
3 3 SEC 2-2
2
3 3
Y10-8"C/C.

SEC 2-2
SEC 2-2

2 2 AT MID SPAN
17'

2 2
SEC 3-3

SEC 3-3
2 GRADE SLAB
3 C3 3 5" THK. C4
11'-6"

3 3
SEC 3-3

3 3

3 SEC 3-3
3 C5 3
C6
SEC4-4 SEC 2-2

2 2 SEC 2-2

SEC6-6
15'-2"

2 2
6 6

4 7 7
SEC2-2

4 4 C8 C9
C7
4'-3"

SEC7-7

5 2
SEC2-2

8 2 1 C10 C11 1
8 4'
4'-4"

3 3 C12 C13
6
5
SEC7-7
2

5 2
SEC 3-3
4'

C14 C16
SEC 2-2 7
7 4 4 7
3" 2'-6"

C15 SEC 5-5 SEC 2-2


8
SEC4-4

2 5
2

LAYOUT OF RETAINING WALL


NOTE:
1) ALL COLUMNS ARE CENTRALLY PLACED ALONG THE GRID LINES UNLESS NOTED
OTHERWISE (UNO)
2) IF THIS DIMENSION IS NOT ACHIEVED AT SITE, THE DISCREPANCY SHALL BE BROUGHT TO
THE NOTICE OF THE ENGINEER AND ARCHITECT ABHYYUDAYA
STRUCTURAL CONSULTANTS

#1553, 5th Block Sir M Vishweshwaraiah Layout Bengalure-560056


Email: abhyudayastr@gmail.com
Mobile:+91-9036430036

ST-LK77-FD-03 A2 R0

GOOD FOR CONSTRUCTION LK77 31.03.2023 1" = 72"


X
4" A 4"

4"
SCHEDULE OF FOOTING

FOOTING
FOOTING SIZE FOOTING DEPTH FOOTING REINFORCEMENT *

b (Reinf) long bar


TYPE A A
A B D 'a' bars 'b' bars

F1 4'-6" 5'-3" 2'-0" BOT-Y10@4"c/c BOT-Y10@4"c/c


a (Reinf) short bar

B
5'-3" 6'-6" 2'-6"

Y
F2 BOT-Y12@4"c/c BOT-Y12@4"c/c

F3 7'-0" 7'-9" 2'-6" BOT-Y16@5"c/c BOT-Y16@5"c/c

F4 7'-9" 8'-6" 2'-6" BOT-Y16@5"c/c BOT-Y16@5"c/c

4"
PLAN
F5 8'-6" 8'-9" 3'-0" BOT-Y12@4"c/c BOT-Y12@4"c/c TYPICAL FOOTING DETAIL
F6 9'-3" 10'-9" 3'-0" BOT-Y12@4"c/c BOT-Y12@4"c/c * REINF. AT BOTTOM TO BE PROVIDED
WHERE CANTILEVER LENGTH IS MORE.
BOT-Y16@4"c/c BOT-Y16@4"c/c
F7 10'-0" 10'-6" 3'-6" TOP-Y10@8"c/c TOP-Y10@8"c/c COL BARS
COL LINKS
SIDE FACE - Y10@8"c/c EGL±0'-0"

BOT-Y12@4"c/c BOT-Y12@4"c/c
CF1 8'-1" 8'-6" 1'-6"
TOP-Y10@6"c/c TOP-Y10@6"c/c

10'-0"
WATER GRADE
PROOFING SLAB
5''THK BASEMENT LVL
5"

LAYER

P.C.C. 1:4:8. ABHYYUDAYA


STRUCTURAL CONSULTANTS
3"

SIDE FACE REFN. #1553, 5th Block Sir M Vishweshwaraiah Layout Bengalure-560056
Email: abhyudayastr@gmail.com

1'-6" TOP BAR FOOTING DEPTH Mobile:+91-9036430036


D

4" ABOVE 3'-3"


4"

P.C.C.1:4:8.
SECTION A-A
ST-LK77-FD-04 A3 R0

GOOD FOR CONSTRUCTION LK77 31.03.2023 NTS


GROUND FLOOR LVL GROUND FLOOR LVL GROUND FLOOR LVL GROUND FLOOR LVL
6" 6" 6" 6"

NGL NGL NGL NGL

Y10-8"
TYP. DISTRIBUTION TYP. DISTRIBUTION TYP. DISTRIBUTION
WATER Y10-10" REINF. Y8-8" REINF. Y8-8" REINF. Y8-8"
PROOFING Y10-10" Y10-10"
TYP. DISTRIBUTION
LAYER

9'

9'

9'

9'
REINF. Y8-8" Y10-10" WATER WATER WATER
PROOFING PROOFING PROOFING
LAYER LAYER LAYER
Y10-8" Y10-8" Y10-8"

Y10-5" Y10-5" Y10-5" Y10-5"


WATER

10'
PROOFING

3'

3'

3'

3'
LAYER GRADE SLAB
BASEMENT LVL BASEMENT LVL Y10-8"C/C BASEMENT LVL Y10-8"C/C BASEMENT LVL Y10-8"C/C
6"
5"

6"

10"
COLUMN
FOOTING

FOOTING
REQUIREMENTS

DEPTH
4' WELL

FOOTING
DISTRIBUTION
AS PER LIFT

(MIN 5'-0")

WELL

DEPTH
PCC COLUMN COMPACTED
VENDOR

REINF. COMPACTED WELL FOOTING 1'-6" TYP. EARTH


Y10-6" WELL EARTH COMPACTED 1'-6" TYP.
WELL CONSOLIDATED
CONSOLIDATED EARTH
Y10-6" SOIL FILL
SOIL FILL

4"
PCC

4"
Y10-6" PCC
Y10-6"

SECTION 2-2 SECTION 4-4


1'-6"

SECTION 3-3
4"
4"

Y12-4"
Y12-4"

SECTION 1-1

GROUND FLOOR LVL


GROUND FLOOR LVL GROUND FLOOR LVL GROUND FLOOR LVL 6"
6" 6"

NGL
NGL 6" NGL NGL
Y10-4"

TYP. DISTRIBUTION
TYP. DISTRIBUTION TYP. DISTRIBUTION TYP. DISTRIBUTION Y10-10" REINF. Y8-8"
Y10-10" REINF. Y8-8" REINF. Y8-8" REINF. Y8-8"
Y10-10" Y10-10" WATER
9'

9'

9'
WATER WATER WATER PROOFING
PROOFING PROOFING PROOFING LAYER
LAYER LAYER LAYER Y10-8" Y10-8"
Y10-8"
Y10-5"
Y10-5" Y10-8" Y10-8"

3'
3'

3'
3'

BASEMENT LVL Y10-8"C/C


BASEMENT LVL Y10-8"C/C Y10-8"C/C BASEMENT LVL Y10-8"C/C BASEMENT LVL

10"
10"

Y10-5" 6'
4' WELL PCC
WELL PCC COMPACTED
COMPACTED WELL WELL EARTH
EARTH COMPACTED Y10-5" COMPACTED
EARTH EARTH
ABHYYUDAYA
STRUCTURAL CONSULTANTS

#1553, 5th Block Sir M Vishweshwaraiah Layout Bengalure-560056

SECTION 8-8
Email: abhyudayastr@gmail.com
Mobile:+91-9036430036
FOOTING

SECTION 5-5
DEPTH

COLUMN COLUMN
FOOTING
DEPTH

FOOTING 1'-6" TYP. FOOTING


1'-6" TYP.
4"

PCC
4"

PCC

SECTION 6-6 SECTION 7-7

ST-LK77-FD-05 A2 RO

GOOD FOR CONSTRUCTION LK77 31.03.2023 NTS


LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@6"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C

FOURTH TO M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500


TERRACE
FLOOR LEVEL Y16 Y20 Y12 Y12
Y20 Y25 Y16 Y16 Y12 Y12 Y12

4-Y20+12-Y16 4-Y25+12-Y20 8-Y16+6-Y12 4-Y16+8-Y12 8-Y12 10-Y12 10-Y12

LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@6"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C
THIRD TO M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500
FOURTH
FLOOR LEVEL
Y12 Y16 Y12 Y12
Y16 Y20 Y16 Y16 Y12 Y12 Y12

14-Y16+2-Y12 4-Y20+12-Y16 8-Y16+6-Y12 8-Y16+4-Y12 8-Y12 10-Y12 10-Y12

LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@6"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C
SECOND TO
M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500
THIRD FLOOR
LEVEL
Y12 Y16 Y12
Y16 Y20 Y16 Y20 Y12 Y12 Y12

14-Y16+2-Y12 4-Y20+12-Y16 8-Y16+6-Y12 12-Y20 8-Y12 10-Y12 10-Y12

LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@6"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C
FIRST TO
SECOND M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500
FLOOR LEVEL
Y12 Y16 Y12
Y16 Y20 Y16 Y25 Y12 Y16 Y12

14-Y16+2-Y12 8-Y20+8-Y16 8-Y16+6-Y12 12-Y25 8-Y12 10-Y16 10-Y12

GROUND TO LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@6"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C
FIRST FLOOR M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500
LEVEL

Y16 Y20 Y12 Y16


Y20 Y25 Y16 Y25 Y16 Y20 Y12

12-Y20+4-Y16 4-Y25+12-Y20 8-Y16+6-Y12 12-Y25 8-Y16 4-Y20+6-Y16 10-Y12

ABHYYUDAYA
STRUCTURAL CONSULTANTS

#1553, 5th Block Sir M Vishweshwaraiah Layout Bengalure-560056

FOOTING TO LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C LINKS : Y8@6"C/C LINKS : Y8@8"C/C LINKS : Y8@8"C/C
Email: abhyudayastr@gmail.com
Mobile:+91-9036430036

GROUND
FLOOR LEVEL M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500 M25:Fe500

Y20 Y20 Y16 Y16 Y12


Y25 Y25 Y20 Y25 Y16 Y20 Y16

4-Y25+12-Y20 12-Y25+4-Y20 4-Y20+10-Y16 12-Y25 8-Y16 4-Y20+6-Y16 4-Y16+6-Y12

COLUMN MARKED 2'-0"X2'-0" 2'-0"X2'-0" 1'-6"X2'-0" 1'-6"X1'-6" 0'-6"X1'-6" 1'-0"X1'-6" 1'-0"X1'-6"


C10,C11,
COLUMN MARKED C1,C2 C3,C4,C5&C6 C7,C9 C8 C12&C13 C14,C15 C16 ST-LK77-FD-06 A2 RO

GOOD FOR CONSTRUCTION LK77 31.03.2023 NTS


A B C D E F
2'-6" 15' 5'-9" 5' 5'-6" 3'-9" 2'-6"

SLAB 6"
3'

1
PTB(2'-0"X1'-6")
12'-6"

B10(1'-0"X1'-6")
B13(1'-0"X1'-6")
B10(1'-0"X1'-6")

SLAB 7"
17'

SLAB 6"

PTB(2'-0"X1'-8")
2
B9(1'-0"X1'-6")

B12(1'-0"X1'-6")

B9(1'-0"X1'-6")
11'-6"

SLAB 6" SLAB 6"


SLAB 6"

SLAB 6"
PTB(2'-0"X1'-8")
3
B11(1'-0"X1'-6")
B8(1'-0"X1'-6")

B8(1'-0"X1'-6")
14'-5"

SLAB 6"
SLAB 6"

PTB(2'-0"X1'-6") PTB(2'-0"X1'-6")

4
4'-10"

B14(0'-8"X1'-6")
5'

SLAB 6"
B15(0'-6"X1'-6") B16(0'-6"X1'-6")

B17(0'-6"X1'-6")

B1(0'-6"X1'-6")
5 B2(0'-8"X1'-6") B4(0'-8"X1'-6")
4'-4"

B3(0'-8"X1'-6") INV
SLAB 6"
6 SLAB 6"
Up.
B5(0'-6"X1'-6") B6(0'-6"X1'-6")
4'

B7(0'-8"X1'-6")
7 SLAB 6"
3" 2'-6"

RAMP
8 UP UP

ABHYYUDAYA
STRUCTURAL CONSULTANTS

#1553, 5th Block Sir M Vishweshwaraiah Layout Bengalure-560056

LAYOUT OF BEAMS AND SLABS AT GROUND FLOOR LEVEL Email: abhyudayastr@gmail.com


Mobile:+91-9036430036

ST-LK77-FF-01 A2 R0

GOOD FOR CONSTRUCTION LK77 19.04.2023 1" = 72"


A B C D E F

2
2'-6" 15' 5'-9" 5' 5'-6" 3'-9" 2'-6"

Y10-6"-(Top) Y8-8"(Bottom)
3'

2'-6"

2'-6"
2
5'-3" 3'-9"
1 1
1 1

Y8-6"
Y8-7"

Y8-6"
2'-6" 1'-6" 2'-6"
1'-6"
17'

Y8-4" Y8-8"
Y8-4"
4'-3"

1'-6"
1'-6"
Y10-6"-(Top) Y8-8"(Bottom)

Y10-6"-(Top) Y8-8"(Bottom)
2
1'-3"

1'-3"
3'

Y8-8"
Y8-8"

Y8-6" Y8-6"
2'-6"
11'-6"

2'-6" 1'-6" 1'-6"

Y8-4" GROUND FLOOR LVL


1'-3"

1'-3"
3'

6" 1'-6"
3
Y10-6"
1'-6"

1'-6"
3'-9"

6"
Y8-7"

Y8-8"

2'-6" 1'-6" 2'-6" Y8-8"


1'-6"
14'-5"

Y8-4" Y8-6"
SECTION 1-1
GROUND FLOOR LVL
3'-9"

3'-9"

3'-9"

2'-6"
1'-6"

6" 1'-6"
Y10-6"
4
6"

Y10-4" Y8-4" Y10-4"


5'

Y8-6" Y8-8"
5 SECTION 2-2
3
4'-4"

Y10-4"
(T&B)

2'
Y8-6"
(T&B)

6 Y10-4"
Y10-4"
(T&B) Y8-6"
4'

(T&B)
Y8-8"
(T&B)

7 Y10-4"
3" 2'-6"

8
RAMP SECTION 3-3
UP UP
ABHYYUDAYA
STRUCTURAL CONSULTANTS

R C DETAILS OF SLABS AT GROUND FLOOR LEVEL #1553, 5th Block Sir M Vishweshwaraiah Layout Bengalure-560056
Email: abhyudayastr@gmail.com
Mobile:+91-9036430036

NOTE:
1) ONLY SLAB MAIN REINFORCEMENT IS INDICATED FOR CLARITY. DISTRIBUTION STEEL WHEREVER NECESSARY SHALL BE Y8-8" C/C
2) SLABS, BEAMS ETC ARE NOT DESIGNED FOR CONSTRUCTION LOADS AND HENCE CARE TO BE TAKEN DURING CONSTRUCTION TO ENSURE
THAT THE ALLOWABLE STRESS LIMITS (AND DESIGN LOADS) ARE NOT EXCEEDED.
3) AVERAGE THICKNESS OF THE FINISHES NOT TO BE EXCEED 3 INCHES.
4) IF IN DOUBTS PLEASE CLARIFY BEFORE CONSTRUCTION.

INDICATES TOP BAR INDICATES BOTTOM BAR

ST-LK77-FF-02 A2 R0

GOOD FOR CONSTRUCTION LK77 19.04.2023 1" = 72"


2-Y16

2-Y16 2-Y16 2-Y16 2-Y16 2-Y12


2' 2'

Ld (typ) 2-Y16
2L-Y8-6"
2-Y16 2-Y16 2-Y16 2-Y16
2L-Y8-6" 2L-Y8-6" B3(0'-8" X1'-6") INV 2L-Y8-4" 2L-Y8-6" 2L-Y8-8"

B1(0'-6" X1'-6") B2(0'-8" X1'-6") B4(0'-8" X1'-6") B5(0'-6" X1'-6") B6(0'-6" X1'-6")

2-Y16

1'-3" 2-Y16 2-Y12 1'-3"


2L-Y8-4"

B7(0'-8" X1'-6")

3-Y12 3-Y16 3-Y16 3-Y16 3-Y12


3'-9" 3'-9" 3' 3' 4'-3" 4'-3"

1'-9" 3-Y16 3-Y12 1'-9" 1'-9" 3-Y16 1'-9"


2L-Y8-4" 2L-Y8-8" 2L-Y8-4" 2L-Y8-6" 2L-Y8-4" 2L-Y8-6" 2L-Y8-4"

B8(1'-0" X1'-6") B9(1'-0" X1'-6") B10(1'-0" X1'-6")

3-Y12 3-Y16 3-Y16 3-Y16


3'-9" 3'-9" 3' 3' 4'-3" 4'-3"

1'-9" 3-Y20 3-Y16 1'-9" 1'-9" 3-Y16 1'-9"


2L-Y10-4" 2L-Y10-8" 2L-Y10-4" 2L-Y8-6" 2L-Y8-4" 2L-Y8-8" 2L-Y8-4"

B11(1'-0" X1'-6") B12(1'-0" X1'-6") B13(1'-0" X1'-6")

2-Y16 2-Y16 2-Y16 2-Y16


2'

ABHYYUDAYA
STRUCTURAL CONSULTANTS

1'-6" 2-Y20 2-Y16 1'-6" 2-Y16 2-Y16


#1553, 5th Block Sir M Vishweshwaraiah Layout Bengalure-560056

2L-Y10-4" 2L-Y8-4" 2L-Y8-6" 2L-Y8-6" Email: abhyudayastr@gmail.com


Mobile:+91-9036430036

B14(0'-8" X1'-6") B15(0'-6" X1'-6") B16(0'-6" X1'-6") B17(0'-6" X1'-6")

ST-LK77-FF-03 A3 R0

GOOD FOR CONSTRUCTION LK77 19.04.2023 NTS