You are on page 1of 6
spepch pa 1SBsoNIS pit G UTS Carrier LLC. ED ane Our Ref: 3110122866-3 DATE : 12-10-2023 M/S THE FIRST INVESTOR DUBAI, U.A.E ATTN: MR JAWED PROJ: CARLTON SUBJECT: OFFER FOR SUPPLY & DELIVERY OF CARRIER AIR COOLED CHILLER We thank you for your interest in our products and services. As the leading supplier in HVAC&R industry, we are pleased to submit our techno commercial offer for supply of Chillers with complete details Based on the data furnished by you, we are pleased to give our proposal as per ceeraaeeetaneete ‘Annexure-1: Offered Equipment Features & Price Annexure-2: Commercial Terms and Conditions Annexure-3: UTS Carrier Warranty Policy & Carrier Standard Terms and Conditions. Should you require any additional information, please feel free to contact us. We now look forward to receive your valuable order. Thanking you and assuring you our best services always, Yours faithfully, Thanks and regards ; oe Kabeer Mohiuddin Jaffar Asst Sales Manager - CMS ‘Abu Dhabi Ain Dual Fujtran uuseaton ao A Khaimah PC Bon3077 PO Box 18640 0 Sor2240 PO Box 32009 Untas Arab United sept pe SSiuncts pt g UTS Carrier L.L.C. GD Rear aaeta ANNEXURE-1 SCOPE OF SUPPLY 2. Quality Assurance: Air Cooled Chiller: ( WITH VFD) | 30KAV “AQUAFORCE” Air-cooled chillers, from Carrier Montluel factory in France are Factory assembled single piece air-cooled chiller, shall include all factory wiring, piping, controls, refrigerant charge (R134a), completely independent refrigerant circuits, variable-speed twin screw compressors with induction motor (30KAV) or permanent magnet motor (30KAVP) The unit performances shall be certified by Eurovent or AHRI independent testing laboratory. The unit shall operate at full oad up with ambient temperatures ranging from -20°C to 48°C (with high ambient option) . Unit shall be designed, manufactured and tested in a facility with a quality management system certified ISO 9001 and environmental management system ISO 14001. Unit shall be run tested at the factory. ‘The machine shall continue to operate (at reduced capa 48°C as standard and up to 55°C with high ambient option. in ambient temperatures up to ~ Machine frame and enclosure shall be made of galvanised sheet steel. - Frame and enclosure shall be painted in oven-baked polyester powder paint in light grey colour (RAL 7035). ~ Unit shall have semi-hermetic variable-speed driven twin- screw compressors with internal relief valve and check valve to avoid reverse rotation on shutdown. = Compressor shall be equipped with an integrated resonator array to reduce discharge gas pulsations. = Compressor bearings shall be designed for minimum 100 000 hours. ~ Capacity control shall be provided by air-cooled variable- speed drive for maximum reliability ~ Compressor capacity control shall be stepless from 100% to 20% load. - Unit shall be equipped with a single flooded evaporator. ‘Abu Dhabi alain Dubat Fujairah as Al Knaumah PC Bowa077 PO Box 16649 PO Bax PO Box 2246 PO Bor 1643 nied Arab Emirates _Unted Arab Ermcles nied Av Eales Une Aa Er nee Arab Erica pe cua UTS Carrier L.L.C. E> Beane rarer - Evaporator shall be tested and stamped in accordance with the European directive for pressurised equipment 97/23/EC. ~ Shell shall be insulated with 19 mm closed-cell foam with a maximum K factor of 0.28. Evaporator thermal insulation shall be factory fitted. ~ The evaporator shall have a drain and vent in each head. ~ Chiller shall have only one water inlet and outlet connection with Victaulic couplings to avoid vibration transmission and to accommodate minor pipework misalignment. = Condenser coils shall be W-shaped to ensure compact dimensions. = Coils shall be entirely made of aluminium alloy, micro- channels type. = Coils shall be leak-tested at 15.5 bar. ~ Fans shall be direct-drive, equipped with an impeller with 9 aerodynamic blades and a rotating shroud to ensure optimal leak-tightness between the blades and the fan housing, ~ Fans impellers shall be of one-piece and made of a corrosion-resistant composite material, and statically and dynamically balanced. ~The three-phase electric motors shall have isolation class F, IP SS protection and a minimum, efficiency of 80%. They shall have individual overload protection via a disconnect switch. - Unit shall operate at 400 Volts (+/- 10%), 3-phases, 50 Hertz power supply without neutral. ~ Control circuit voltage shall be 24 V maximum, supplied by a factory-installed transformer. - Unit shall be supplied with factory-installed main circuit breaker/isolator. ~ Unit shall have single point power connection, The inverter driven compressor motors start up current shall be less than the full load operating current. Variable Frequency Drive (VFD) ~All VFO shall be air-cooled: compressors, fans, pumps without any need of any additional liquid cooling system to guarantee system reliability. - All VED shall be located in an electrical box for protection against external aggressions (water ingress, dust, UV lights). - All VED cooling system shall be air-cooled for high reliability and simplicity without any need of glycol pump and risk of glycol water inside the electrical box (Glycol- cooled VFO type not recommended) and shall be separated from the compressor to avoid mechanical vibrations and cooling capacity loss (Refrigerant-cooled VED type not recommended). ~All VFO shall have a good aeration. Make sure filters in front of electrical box are not obstructed Unit control shall include as a minimum: Microprocessor with non-volatile memory, picture guided unit/operator interface, the LOCAL/OFF/REMOTE/CCN selector and a 7 inches coloured ‘touch-screen display with 10 language capability. German, English, Spanish, French, Italian, aan Dubat Fujaran useatan Rae Al Khaimah Unted Arb Grurctes. Unted arab Emiatse Unted ars Emirates Unted Arab Emirates Unted arab ph lS 3 G UTS Carrier LLC. ED Aon patrons cae Dutch, Portuguese, Turkish, Russian and one additional language on customer choice (downloadable on job site) All the above features make 30XB Aquaforce chillers best in their class and offer better value for money for our valuable customers. Chillers Exclusions: , Any installation, Control af Secondary pumps (if available), Factory Witness / Factory visit, Factory performance Test , Offloading , Chillers assembly /Joining etc, Cu/al Condensors 3. Scope of supply ‘+ 02.Nos. CARRIER AIR COOLED 30KAV CHILLERS With VFD . ANNEXURE-2 COMMERCIAL TERMS AND CONDITIONS 1. OFFER: Total price for offered equipment as per our detailed scope of supply, technical selection and terms and conditions stated herein this letter is given below: ] T ] suit Description | QTY __— Total Price (AED) Offred 30KAV1100-MCHE | Air Cooled Chillers , (FRANCE) CAP 295 TREACH | (ACTUAL TR AT 46 DEG C) | | 4 Years warranty on the full chiller from o1 | 1,200,000 the date of delivery is included against any | | | manufacturing defects +5 Years compressor warranty from the date of delivery is included . | | A Onabi iain Dubai Fran useaton fae A Khalnsh Unted ab Ervrles Untied arab Emifcles Unted arc EmvatesUnied rab Emklet Une aa EnvatesUnieg arab males pep pyM6unttl2S ,211 G UTS Carrier L.L.C. E> nchinenteteeran Total Price for ITEM 1,200,000+VAT ‘A) BELOW OPTIONS ARE INCLUDED IN THE ABOVE PRICE FOR CHILLERS. ‘© Opt 15 Compressor enclosure is included factory builtin Opt 23 Side panels for the chillers is included factory builtin © Opt 281 Al Cladding for evaporator builtin Opt Skid ( Special packing) * Opt 318 UAE compliance option is included factory builtin ‘+ OPT 16 High ambient option ‘+ 93A Discharge valve ‘+ External Spring Mounts and Flow switches. © We have also included site applied condenser coating with 5 years warranty on the above price which will increase the Life of the condenser . fi a 1. Price Basis: Please note that above total price is ex-UTS CARRIER LLC warehouse. As an additional service deliveries to customer site/location can be arranged by UTS CARRIER LLC on behalf of the customer at no extra cost. 2. Taxes/Duties: Our quoted prices are based on current import tariffs applicable in the U.A.E. Please be kindly informed that any import tariffs increase will be applied on our quoted price without any further notice. Prices quoted are exclusive of sales tax / VAT which will be subject to inclusion when implemented by UAE authorities. 3. Standard Payment terms: ‘abu Dab Unies Ara Erirtes ual © Unted a0 Emvstee Unted ara Em pep-B ga gS Barc IS pt Gg UTS Carrier LLC. E> xo ple ‘© UTS Carrier standard payment terms to accept orders are: © 15% advance 85% CDC before delivery. 4. Delivery: Chillers : 22-24 Weeks from the date of LPO and advance payment, 5. Warranty: We are offering carrier standard parts warranty for the offered equipment’ as per UTS Carrier standard warranty policy (attached herewith) against manufacturing defects subject to proof of Preventive maintenance as per Carrier Operations & Maintenance manual from the date of startup/commissioning. Consumables and labor is excluded from warranty. 6. Storage charges: Please note that once the shipment arrives in UAE, delivery of units shall have to be taken immediately within a period 7 days of this intimation. As UTS CARRIER has no storage space to hold or store material shipments, there would be storage charge of 2% of material value per week of delay in accepting the delivery. UTS CARRIER LLC management decision will be final Val vi: Offered prices are valid for 15 Days from the date of this letter, after which, if any price increase received from factory shall be applicable prevailing at that time. ‘Abu Dhebt ian Fujsran Muesatan Foe Al Khaimah Unted Arab Emirates Untied arab Emirate United Arab Emirates United Arab Emirates United Arab Era Fax 084487000 Fox

You might also like