You are on page 1of 8

Planning Document

Complex Details:
Complex Name: Anjum Villas
Complex Address: 1 Dahlia Str. Zinniaville, Rustenburg, 0300
Coordinates: -25.6506388, 27.2421140
BC Name: Baboo Bodiat
BC contact: 083 786 1261

Quick Scope:
Unit Count: 24
Fibre Requirements: 4F, 12F, 24F
Version 1.0
Locality 24x2F Retracta-
net

12x2F Retracta-
net

72F Micro-Fibre

24F Micro-Fibre

48F Micro-Fibre

-25.6506388, 27.2421140 72F Micro-Fibre

96F Micro-Fibre

144F Micro-Fibre

12F HDD-Fibre

24F HDD-Fibre

48F HDD-Fibre

72F HDD-Fibre

96F HDD-Fibre

Existing Estate Manhole Boundary Wall Box New Trench Line Road Cut
Evotel Manhole (900mm x 900mm)
New 4 Port Tap-in-Box (Up to 8F) (450mm Deep) (900mm Deep)
Access Box/Point Distribution Box New Trench Line Feeder Road Drill (2x 110mm)
Evotel Handhole (600mm x 600mm)
4 Port Tap-in-Box (Up to 24F) Route (900mm Deep) 450mm Deep
Access Box/Point Distribution Box Road Drill (2x 110mm)
Existing Estate Manhole Existing Line
End of Run Slack Storage (Up to 96F) 900mm Deep Project Name:
Existing Estate Manhole
New Dome Joint
Boundary Wall Box
(Up to 2F)
Distribution Box
(Up to 120F)
Road Cut
(450mm Deep) X Blockage Anjum Villas
24x2F Retracta-
Topographical Map net

12x2F Retracta-
net

72F Micro-Fibre

24F Micro-Fibre
1 13 19
7
48F Micro-Fibre

2 14 20
8 72F Micro-Fibre

15
3 9 21 96F Micro-Fibre

16 22 144F Micro-Fibre
4 10

17 12F HDD-Fibre
5 11 23

24F HDD-Fibre
18
6 12 24
48F HDD-Fibre

72F HDD-Fibre

96F HDD-Fibre

Existing Estate Manhole Boundary Wall Box New Trench Line Road Cut
Evotel Manhole (900mm x 900mm) (450mm Deep)
New 4 Port Tap-in-Box (Up to 8F) (900mm Deep)
Access Box/Point Distribution Box New Trench Line Road Drill (2x 110mm)
Evotel Handhole (600mm x 600mm)
4 Port Tap-in-Box (Up to 24F) (900mm Deep) 450mm Deep
Access Box/Point Distribution Box Road Drill (2x 110mm)
Existing Estate Manhole Existing Line
End of Run Slack Storage (Up to 96F) 900mm Deep Project Name:
Existing Estate Manhole
New Dome Joint
Boundary Wall Box
(Up to 2F)
Distribution Box
(Up to 120F)
Road Cut
(450mm Deep) X Blockage Anjum Villas
Site Plan 2:
Proposed Evotel Route 24x2F Retracta-
net

12x2F Retracta-
net

Each CTP to 12F Micro-Fibre

feed 2 units
24F Micro-Fibre
1 13 19
7
12 DC03-12F
3 9
8 48F Micro-Fibre

2 14 20 Fiber to be
8
pinned inside 72F Micro-Fibre
conduit on wall
15
3 9 21
96F Micro-Fibre
2 6 7 11 DC02-24F
16 22
4 10 144F Micro-Fibre
DC01-12F
17 12F HDD-Fibre
5 11 23
5 NDP with 32-
1 4 10 Way Splitter 24F HDD-Fibre
18
6 12 24

48F HDD-Fibre
Trench & lay 4F
BB for sweep
72F HDD-Fibre

96F HDD-Fibre

Existing Estate Manhole Boundary Wall Box New Trench Line Road Cut
Evotel Manhole (900mm x 900mm) (450mm Deep)
New 4 Port Tap-in-Box (Up to 8F) (900mm Deep)
Access Box/Point Distribution Box New Trench Line Road Drill (2x 110mm)
Evotel Handhole (600mm x 600mm)
4 Port Tap-in-Box (Up to 24F) (900mm Deep) 450mm Deep
Access Box/Point Distribution Box Road Drill (2x 110mm)
Existing Estate Manhole Existing Line
End of Run Slack Storage (Up to 96F) 900mm Deep Project Name:
Existing Estate Manhole
New Dome Joint
Boundary Wall Box
(Up to 2F)
Distribution Box
(Up to 120F)
Road Cut
(450mm Deep) X Blockage Anjum Villas
Site Plan 1:
Existing 24x2F Retracta-
net

12x2F Retracta-
net

12F Micro-Fibre
Each CTP to
feed 2 units
24F Micro-Fibre
1 13 19
7
12 DC03-12F
3 9
8 48F Micro-Fibre

2 14 20 Fiber to be
8
pinned inside 72F Micro-Fibre
conduit on wall
15
3 9 21
96F Micro-Fibre
2 6 7 11 DC02-24F
16 22 144F Micro-Fibre
4 10
DC01-12F
17 12F HDD-Fibre
5 11 23
5 NDP with 32-
1 4 10 Way Splitter 24F HDD-Fibre
18
6 12 24
48F HDD-Fibre
Trench & lay 4F
BB for sweep
72F HDD-Fibre

96F HDD-Fibre

Existing Estate Manhole Boundary Wall Box New Trench Line Road Cut
Evotel Manhole (900mm x 900mm) (450mm Deep)
New 4 Port Tap-in-Box (Up to 8F) (900mm Deep)
Access Box/Point Distribution Box New Trench Line Road Drill (2x 110mm)
Evotel Handhole (600mm x 600mm)
4 Port Tap-in-Box (Up to 24F) (900mm Deep) 450mm Deep
Access Box/Point Distribution Box Road Drill (2x 110mm)
Existing Estate Manhole Existing Line
End of Run Slack Storage (Up to 96F) 900mm Deep Project Name:
Existing Estate Manhole
New Dome Joint
Boundary Wall Box
(Up to 2F)
Distribution Box
(Up to 120F)
Road Cut
(450mm Deep) X Blockage Anjum Villas
Photos
24x2F Retracta-
net

12x2F Retracta-
net

12F Micro-Fibre

24F Micro-Fibre

48F Micro-Fibre

72F Micro-Fibre

96F Micro-Fibre

144F Micro-Fibre

12F HDD-Fibre

24F HDD-Fibre

48F HDD-Fibre

72F HDD-Fibre

96F HDD-Fibre

Existing Estate Manhole Boundary Wall Box New Trench Line Road Cut
Evotel Manhole (900mm x 900mm)
New 4 Port Tap-in-Box (Up to 8F) (450mm Deep) (900mm Deep)
Access Box/Point Distribution Box New Trench Line Road Drill (2x 110mm)
Evotel Handhole (600mm x 600mm)
4 Port Tap-in-Box (Up to 24F) (900mm Deep) 450mm Deep
Access Box/Point Distribution Box Road Drill (2x 110mm)
Existing Estate Manhole Existing Line Project Name:
End of Run Slack Storage (Up to 96F) 900mm Deep
Anjum Villas
Existing Estate Manhole
New Dome Joint
Boundary Wall Box
(Up to 2F)
Distribution Box
(Up to 120F)
Road Cut
(450mm Deep) X Blockage
Splice Plan 24x2F Retracta-
net

Anjum Villas Splice Diagram 12x2F Retracta-


net
Splitter No. 1:32-Way Splitter Fiber Spliced Cable Label Unit Complex
1:32 Splitter 1 F1 T1F1 DC01-12F 1 Anjum Villas
12F Micro-Fibre
F2 T1F2 DC01-12F 2 Anjum Villas
F3 T1F3 DC01-12F 3 Anjum Villas
F4 T1F4 DC01-12F 4 Anjum Villas 24F Micro-Fibre
F5 T1F5 DC01-12F 5 Anjum Villas
F6 T1F6 DC01-12F 6 Anjum Villas 48F Micro-Fibre
F7 T1F1 DC02-24F 7 Anjum Villas
F8 T1F2 DC02-24F 8 Anjum Villas
F9 T1F3 DC02-24F 9 Anjum Villas 72F Micro-Fibre

F10 T1F4 DC02-24F 10 Anjum Villas


F11 T1F5 DC02-24F 11 Anjum Villas 96F Micro-Fibre
F12 T1F6 DC02-24F 12 Anjum Villas
F13 T1F7 DC02-24F 13 Anjum Villas
144F Micro-Fibre
F14 T1F8 DC02-24F 14 Anjum Villas
F15 T1F9 DC02-24F 15 Anjum Villas
F16 T1F10 DC02-24F 16 Anjum Villas 12F HDD-Fibre

F17 T1F11 DC02-24F 17 Anjum Villas


F18 T1F12 DC02-24F 18 Anjum Villas 24F HDD-Fibre
F19 T1F1 DC03-12F 19 Anjum Villas
F20 T1F2 DC03-12F 20 Anjum Villas
48F HDD-Fibre
F21 T1F3 DC03-12F 21 Anjum Villas
F22 T1F4 DC03-12F 22 Anjum Villas
F23 T1F5 DC03-12F 23 Anjum Villas 72F HDD-Fibre
F24 T1F6 DC03-12F 24 Anjum Villas

96F HDD-Fibre

Existing Estate Manhole Boundary Wall Box New Trench Line Road Cut
Evotel Manhole (900mm x 900mm)
New 4 Port Tap-in-Box (Up to 8F) (450mm Deep) (900mm Deep)
Access Box/Point Distribution Box New Trench Line Road Drill (2x 110mm)
Evotel Handhole (600mm x 600mm)
4 Port Tap-in-Box (Up to 24F) (900mm Deep) 450mm Deep
Access Box/Point Distribution Box Road Drill (2x 110mm)
Existing Estate Manhole Existing Line
End of Run Slack Storage (Up to 96F) 900mm Deep Project Name:
Existing Estate Manhole
New Dome Joint
Boundary Wall Box
(Up to 2F)
Distribution Box
(Up to 120F)
Road Cut
(450mm Deep) X Blockage Anjum Villas
Address: Unit 5 - Gallagher Place
South54 Richards Drive
Halfway House
Midrand
1685

Phone: 0860 EVOTEL (386 835)


Website: wwww.Evotel.co.za

I ,__________________________ the representative of ____________________________ Estate/Complex, have read through the proposed plans
provided by Evotel for the roll out of Evotel’s Fibre infrastructure within the above mentioned Estate/Complex.

I understand the proposed route/s provided by Evotel in order to provision Fibre to all units of the Estate/Complex. I acknowledge that there may be
variants/changes to the proposed plans once build has started. However this will be communicated/relayed to myself before any changes have been
made. I have informed all tenants as well as all other relative parties effected by the installation eg. Board of trustees & Investors of the installation and
all parties are in agreement for the commencement of Evotels Fibre Optic Network to be installed within the above mentioned Estate/Complex.

Estate Rep Name: ________________________ Signature: ____________________________ Date: ________________________