Professional Documents
Culture Documents
1
Product Status Report
21/03/2024 15:21
Logged Diagnostic Codes [Diagnostic Clock = 10194 hours] - Machine Control 325D/328D/329D
(BZP02148)
Code Description Occ. First Last
190- 8 Engine Speed Sensor : Abnormal Frequency, 21 10177 10194
Pulse Width, or Period
374- 5 Swing Brake Solenoid : Current Below Normal 44 10194 10194
581- 5 Power Shift Solenoid : Current Below Normal 44 10194 10194
2265- 4 Hydraulic Pump #1 Outlet Pressure Sensor : 44 10194 10194
Voltage Below Normal
2265- 8 Hydraulic Pump #1 Outlet Pressure Sensor : 44 10194 10194
Abnormal Frequency, Pulse Width, or Period
167-12 Alternator Charging Voltage Sensor : Failure 20 10179 10193
41- 6 8 Volt DC Supply : Current Above Normal 1 10177 10177
588- 9 Monitor System Display : Abnormal Update Rate 4 10177 10177
2300- 9 Switch Panel : Abnormal Update Rate 2 10177 10177
Logged Event Codes [Diagnostic Clock = 10194 hours] - Machine Control 325D/328D/329D
(BZP02148)
Code Description Occ. First Last
E043 (2) Low System Voltage Warning 2 10177 10194
Lifetime: Time vs Front Hyd Pump Pres - Machine Control 325D/328D/329D (BZP02148)
Front Hyd Pump Pres( kPa ) hours %
<20000,0 6441,60 96,47
20000,0-21999,0 96,40 1,44
22000,0-23999,0 50,95 0,76
24000,0-25999,0 28,80 0,43
26000,0-27999,0 17,50 0,26
28000,0-29999,0 11,15 0,17
30000,0-31999,0 7,15 0,11
32000,0-33999,0 4,95 0,07
34000,0-35999,0 8,45 0,13
36000,0-37999,0 0,80 0,01
38000,0-39999,0 0,00 0,00
>40000,0 9,80 0,15
Lifetime: Time vs Rear Hyd Pump Pres - Machine Control 325D/328D/329D (BZP02148)
Rear Hyd Pump Pres( kPa ) hours %
<20000,0 8755,05 90,37
20000,0-21999,0 236,60 2,44
22000,0-23999,0 309,90 3,20
24000,0-25999,0 241,90 2,50
26000,0-27999,0 41,25 0,43
28000,0-29999,0 22,70 0,23
30000,0-31999,0 15,90 0,16
32000,0-33999,0 12,85 0,13
34000,0-35999,0 22,50 0,23
36000,0-37999,0 2,05 0,02
38000,0-39999,0 17,70 0,18
>40000,0 9,80 0,10
Tool Configuration - Machine Control 325D/328D/329D (BZP02148)
Active Tool : 0
Description Value Unit
Tool Program Name 0 Active
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Two Pump Flow Combine Disabled or Not Installed
Enable
Initial Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum Disabled or Not Installed kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Extend Pilot Pres for Combined
Attachment Valve
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pres for Combined
Attachment Valve
Tool Program Hydraulic 126,0 Deg C
Temperature High Warning
Event Threshold
Attachment Valve #1 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #1 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #1 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open Disabled or Not Installed sec
Time
Attachment Valve #1 Close Disabled or Not Installed sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #2 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #2 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #2 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #2 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #2 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #2 Open Disabled or Not Installed sec
Time
Attachment Valve #2 Close Disabled or Not Installed sec
Time
Attachment Valve #2 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction
Logged Diagnostic Codes [Diagnostic Clock = 11112 hours] - C6.4 320D (GDC49682)
Code Description Occ. First Last
1797- 3 Fuel Rail Pressure Sensor : Voltage Above Normal 1 11112 11112
3257- 3 Air Inlet Heater : Voltage Above Normal 127 7242 11112
617- 5 Inlet Air Heater Relay : Current Below Normal 1 11105 11105
Logged Event Codes [Diagnostic Clock = 11112 hours] - C6.4 320D (GDC49682)
Code Description Occ. First Last
E198 (2) Low Fuel Pressure 1 11047 11047
E361 (1) High Engine Coolant Temperature 16 10815 10904
E361 (2) High Engine Coolant Temperature 9 10823 10898
Event Triggered:Time vs Engine Speed And Engine Load Factor - C6.4 320D (GDC49682)
rpm <1000 1000- 1200- 1400- 1600- 1800- 2000- 2200- >2400
1199 1399 1599 1799 1999 2199 2400
%
<50 402,25 1054,65 501,25 104,15 192,05 584,60 6,80 0,00 0,00
50-59 0,45 1,75 10,80 31,70 77,35 215,65 2,25 0,00 0,00
60-69 0,20 1,40 8,10 33,30 115,60 398,80 2,70 0,00 0,00
70-79 0,20 0,75 6,45 35,70 194,85 752,95 3,45 0,00 0,00
80-90 0,20 0,40 5,30 39,40 295,55 1158,10 3,25 0,00 0,00
>90 0,45 0,50 7,05 71,95 2569,00 1798,80 2,45 0,00 0,00
Total 403,75 1059,45 538,95 316,20 3444,40 4908,90 20,90 0,00 0,00
Event Triggered:Time vs Engine Speed And Engine Load Factor - C6.4 320D (GDC49682)
rpm Total
%
<50 2845,75
50-59 339,95
60-69 560,10
70-79 994,35
80-90 1502,20
>90 4450,20
Total 10692,55
Monitor
Parameter Value
ECM Serial Number 06ZJ2183AJ
Personality Module Part Number 2909514-00