You are on page 1of 6

R210W-9S Machine Outrigger malfunction

Case Study
1. Problem Information
Problem
Model Problem Relevant Parts Problem Description Remark
category
Pressure switch
/MCV outrigger
spool
R210W- Bad outrigger
Performance /2 cartridge Outrigger malfunction
9S operation
valve
/Harness
/Fuse
2. Reference Case
Part Part
No. HI-DESK Model S/N Region Problem Symptom Action Taken Remark
No. Name

THE OUTRIGGER CYLINDER LH


1 201907-0018 R210W-9S 1335 Cuba AND RH DOES NOT WORK Replace Pilot line Parts 31E5-40540 Pressure sensor
ALSO DOOZER BLADE
Problem in programming of
2 Cartridge
2 201910-0080 R210W-9S 0459 Azerbaijan control board for Replace Pilot line Parts 31Q4-20070
valve
dozer/outrigger operation

4
R210W-9S Machine Outrigger malfunction
Case Study
3. Trouble Shooting map

2
R210W-9S Machine Outrigger malfunction
Case Study
Attachment 1

Field check list NOTE Remark

1. Check actual input pilot pressure


After Connect Pa1,Pb1 gauge (need to T port),
Check the Pilot pressure
- Spec : 30 ±2 bar when operating

1) If the input pilot pressure is abnormal


inspection and replacing Pressure Switch
2) If the problem is not solved after checking and
replacing parts, Check and Replace Fuse and
harness
* Refer to 4 page in regarding with part position
1

3
R210W-9S Machine Outrigger malfunction
Case Study
Attachment 1

Field check list NOTE Remark

1.1 Check pi1 Pressure of MCV


(After Connect regulator pi1 gauge,
check the negative pressure)
- Check Negative pressure Pi1 check when
operating Outrigger
* Negative pressure Spec : 5±2 Bar

1) If the negative pressure is abnormal ,replace


Problem Spool
3 2) Negative pressure is normal, if there is a
problem, Check and Replace 2 Cartridge valve
* Refer to 5 page in regarding with part position

4
R210W-9S Machine Outrigger malfunction
Case Study
Attachment 1

NOTE Remark

5
R210W-9S Machine Outrigger malfunction
Case Study
Attachment 1

NOTE Remark

You might also like