You are on page 1of 1

A B C D E F G H I J

B A
5332 3 4
1 1
275 1452 150 1526 150 1454 25
24 C1-C1 274
150

123 15 137
350
200

135 14 125
738.5
738

2 2
24 150 24 24 150 24
C1-L4 C1-L2
180

180

C1-L2
C1-L4
1285

1305
TUBESHEET SUPPORT TUBESHEET SUPPORT
SEE DRW: 778-07AD SEE DRW: 778-07AD
896.5

3 C1-P18 3
896

C1-P17
C1-P16 25 150 25
25 150 25
100 340 80

100 340 60
3615

3615
134 20 121
119 20 136
312

312

C1-P21 C1-P21
4 4
TUBESHEET SUPPORT
C1-L1 TUBESHEET SUPPORT
SEE DRW: 778-07AD
SEE DRW: 778-07AD
170.5 182
C1-L1
1110

1110
1488

1488

5 C1-L1 5
C1-L1
88.5 45.5 40.5 93.5
135 14 125
294

350
123 15 137
55

C1-H3 C1-H1 C1-C4 C1-H3 SECTION Q - Q


6 C1-C5 C1-C2 SCALE 1:10 6
SECTION F - F
SCALE 1:15
7 7
0 05.07.2023 ISSUED FOR CONSTRUCTION VTA NVT NVH
REV DATE REVISION DESCRIPTION DRAWN CHECKED APPROVED
8 8
B.I.H
BOUSTEAD INTERNATIONAL HEATERS Ltd.
DRAWING TITLE
CONVECTION BOX
SERVICE WASTE HEAT RECOVERY UNIT (WHRU)
9 EBN-3520 A/B/C 9
FOR UARU F.P.S.O. PROJECT
SHEET SCALE: 1:1 ORIGINAL SIZE: A1 DO NOT SCALE NOTE: THIS DRAWING IS THE PROPERTY OF BOUSTEAD
REV. 3 BY DATE CHECKED DATE DESIGN REVIEW DATE APPROVED DATE REV. 2 BY DATE CHECKED DATE DESIGN REVIEW DATE APPROVEDDATE REV. 1 BY DATE CHECKED DATE DESIGN REVIEW DATE APPROVED DATE INTERNATIONAL HEATERS LTD. BURGESS HILL, SUSSEX, U.K.
AND SHALL NOT BE TRACED, PHOTOGRAPHED,
PHOTOSTATED OR REPRODUCED IN ANY MANNER NOR
USED FOR ANY PURPOSE WHATSOEVER EXCEPT BY WRITTEN
PERMISSION OF BOUSTEAD INTERNATIONAL HEATERS LTD.
NOTES
1. THIS DOCUMENT IS TO BE READ IN CONJUNCTION WITH 3. ALL SHARP EDGES SHALL BE GROUND SMOOTH AND ALL 6. ALL DIMENSIONS SHALL BE VERIFIED AND ANY
B.I.H DOCUMENT ETD-089 9. ALL SECONDARY STEEL AND STIFFENING TO BE PROFILED 11. ALL MATERIALS GRADE SHALL BE DESIGNED &
10 SHARP CORNERS ROUNDED PRIOR TO PAINTING. DISCREPANCIES SHALL BE REFERRED TO BIH FOR FABRICATED USING LOCALLY AVAILABLE MATERIAL PER: TITLE:
10
"ENGINEERING STANDARD FOR FABRICATION AND INTO PRIMARY STEEL UNLESS OTHERWISE STATED.
WELDING FOR PROCESS FIRED HEATER STEELWORK".
4. ALL HOLES Ø22mm FOR M20 BOLTS UNLESS OTHERS
STATED. 7.
RESOLUTION.
FABRICATOR SHALL AT NO ACCOUNT BE RELEASED FROM
10. FABRICATOR TO PROVIDE ADEQUATE Ø24mm DRAIN - EN 10025 S355 J2 (TYPE 1) (LIFTING LUGS & LIFTING BEAMS) CONVECTION BOX DETAIL
2. ALL WELDS TO BE CONTINUOUS FILLET WELD. WELD HOLES WHERE REQUIRED. - EN 10025 S355 J2 (TYPE 2) (FOR MAIN W.H.R.U. RAFT)
5. ALL BOLTS TO BE ASTM A325M WITH 1 OFF WASHER, HIS RESPONSIBILITY OF OVERALL EQUIPMENT FIT UP.
EQUAL TO THINNEST PIECE JOINED, BUT NO GREATER - TIS 1227 SS400/ASTM A36 (TYPE 3M) (FOR ALL OTHER REV:
1 OFF HEX NUT & 1 OFF LOCK NUT AS 1 OFF BOLT 8. ALL DIMENSIONS IN MILLIMETERS UNLESS OTHERWISE JOB DRAWING
THAN 6mm, UNLESS OTHERWISE NOTED. ASSEMBLY SET. STATED. BEAMS, COLUMNS, SECONDARY STEEL & CASING) NUMBER 778 NO. 778-07EA-SD-006 0
A B C D E F G H I J