You are on page 1of 1

A B C D E F G H I J

3 4
3600 3
3
1 750 750 1
175 3200 225 175
175
C1-PLT2
C1-PLT1
C1-P25 C1-P2
C1-P1 C1-P35
C1-P25 C1-H2 C1-C7
350
C1-P35 A

350
A
170 240

C1-P40 C1-H5

172.5 450.5
2 2
580

1153

172.5 450.5
1153
C1-H6 C1-H5
C1-P25 C1-P8 C1-P35
170

C1-P35 C1-H6
C1-P25 C1-PLT1
170

C1-PLT1 C1-PLT1
C1-P35 C1-PLT1 C1-PLT1
C1-P25
C1-P40 C1-P35 C1-PLT1
C1-P25 C1-H4 706 C1-PLT1
165

165

180
536

H H J J C1-PLT1 C1-PLT1

180
3 3
C1-P25 C1-PLT1 C1-PLT1
C1-P35
C1-P35 SECTION H - H C1-PLT1
C1-P25 SCALE 1:15 SECTION I - I
C1-P25 C1-P35 SCALE 1:15
165

165
C1-H6 C1-H7
C1-P25 C1-P35
C1-H5
C1-P21
3615
1043

1043
C1-P21 4
C1-P25 C1-H3 4 830
4 4
C1-P25 C1-P10 830
165

165
I I K K 175 175
C1-PLT2 C1-H4 C1-PLT1 C1-H4
C1-P35
C1-P35

350
C1-P25 A

350
A
165

165
C1-H6 C1-P35 C1-H7
C1-H5 C1-P25 C1-H4
5 C1-P35 5
1111

1111
C1-H7

172.5 450.5
C1-H7

1153
172.5 450.5

1153
C1-P9
C1-PLT1 C1-PLT1
C1-P11 C1-PLT1 C1-PLT1
C1-PLT1 C1-PLT1
C1-PLT1 C1-PLT1

180
C1-PLT1

180
6 C1-PLT1 6
175

175
C1-P4 C1-P6 C1-PLT1 C1-PLT1
C1-C8
SECTION G - G SECTION J - J SECTION K - K
SCALE 1:15 SCALE 1:15 SCALE 1:15
7 7
0 05.07.2023 ISSUED FOR CONSTRUCTION VTA NVT NVH
REV DATE REVISION DESCRIPTION DRAWN CHECKED APPROVED
8 8
B.I.H
BOUSTEAD INTERNATIONAL HEATERS Ltd.
DRAWING TITLE
CONVECTION BOX
SERVICE WASTE HEAT RECOVERY UNIT (WHRU)
9 EBN-3520 A/B/C 9
FOR UARU F.P.S.O. PROJECT
SHEET SCALE: 1:1 ORIGINAL SIZE: A1 DO NOT SCALE NOTE: THIS DRAWING IS THE PROPERTY OF BOUSTEAD
REV. 3 BY DATE CHECKED DATE DESIGN REVIEW DATE APPROVED DATE REV. 2 BY DATE CHECKED DATE DESIGN REVIEW DATE APPROVEDDATE REV. 1 BY DATE CHECKED DATE DESIGN REVIEW DATE APPROVED DATE INTERNATIONAL HEATERS LTD. BURGESS HILL, SUSSEX, U.K.
AND SHALL NOT BE TRACED, PHOTOGRAPHED,
PHOTOSTATED OR REPRODUCED IN ANY MANNER NOR
USED FOR ANY PURPOSE WHATSOEVER EXCEPT BY WRITTEN
PERMISSION OF BOUSTEAD INTERNATIONAL HEATERS LTD.
NOTES
1. THIS DOCUMENT IS TO BE READ IN CONJUNCTION WITH 3. ALL SHARP EDGES SHALL BE GROUND SMOOTH AND ALL 6. ALL DIMENSIONS SHALL BE VERIFIED AND ANY
B.I.H DOCUMENT ETD-089 9. ALL SECONDARY STEEL AND STIFFENING TO BE PROFILED 11. ALL MATERIALS GRADE SHALL BE DESIGNED &
10 SHARP CORNERS ROUNDED PRIOR TO PAINTING. DISCREPANCIES SHALL BE REFERRED TO BIH FOR FABRICATED USING LOCALLY AVAILABLE MATERIAL PER: TITLE:
10
"ENGINEERING STANDARD FOR FABRICATION AND INTO PRIMARY STEEL UNLESS OTHERWISE STATED.
WELDING FOR PROCESS FIRED HEATER STEELWORK".
4. ALL HOLES Ø22mm FOR M20 BOLTS UNLESS OTHERS
STATED. 7.
RESOLUTION.
FABRICATOR SHALL AT NO ACCOUNT BE RELEASED FROM
10. FABRICATOR TO PROVIDE ADEQUATE Ø24mm DRAIN - EN 10025 S355 J2 (TYPE 1) (LIFTING LUGS & LIFTING BEAMS) CONVECTION BOX DETAIL
2. ALL WELDS TO BE CONTINUOUS FILLET WELD. WELD HOLES WHERE REQUIRED. - EN 10025 S355 J2 (TYPE 2) (FOR MAIN W.H.R.U. RAFT)
5. ALL BOLTS TO BE ASTM A325M WITH 1 OFF WASHER, HIS RESPONSIBILITY OF OVERALL EQUIPMENT FIT UP.
EQUAL TO THINNEST PIECE JOINED, BUT NO GREATER - TIS 1227 SS400/ASTM A36 (TYPE 3M) (FOR ALL OTHER REV:
1 OFF HEX NUT & 1 OFF LOCK NUT AS 1 OFF BOLT 8. ALL DIMENSIONS IN MILLIMETERS UNLESS OTHERWISE JOB DRAWING
THAN 6mm, UNLESS OTHERWISE NOTED. ASSEMBLY SET. STATED. BEAMS, COLUMNS, SECONDARY STEEL & CASING) NUMBER 778 NO. 778-07EA-SD-007 0