You are on page 1of 23

Microwave (IP Radio)

Commissioning Test

Microwave Transmission System


Commissioning Test
Lokasi site Site ID
Near End : COMBAT KANEYAN COI934
Far End : TARERAN TDO007

Hasil ATP : Diterima / Ditolak

Catatan :

Tanda Tangan
Aviat Telkom

Nama : RANGGA SANJAYA Nama :


NIK :
Microwave (IP Radio)
Commissioning Test

CONTENT

1. SITE INFORMATION....................................................................................................................................3
1.1 SITE DETAIL...................................................................................................................................................3
2. EQUIPMENT INFORMATION.......................................................................................................................4
2.1 OUTDOOR.....................................................................................................................................................4
2.2 INDOOR........................................................................................................................................................5
3. INSTALLATION INSPECTION........................................................................................................................5
3.1 OUTDOOR.....................................................................................................................................................5
3.2 INDOOR........................................................................................................................................................6
4. LINK BUDGET.............................................................................................................................................7
4.1 PATH PROFILE................................................................................................................................................8
5. TEST ITEMS AND FORMS...........................................................................................................................8
5.1 TEST ITEMS FOR PRELIMINARY TEST...................................................................................................................9
5.2 OPTICAL INTERFACE TEST.................................................................................................................................9
5.3 ETHERNET INTERFACE TEST.............................................................................................................................11
5.4 E1 INTERFACE TEST.......................................................................................................................................12
5.5 RF PARAMETER CONFIGURATION....................................................................................................................13
5.6 MICROWAVE PROTECTION..............................................................................................................................14
6. INSTALLATION PHOTOGRAPH...................................................................................................................18
7. PING TEST................................................................................................................................................19
8. HARDWARE INSTALLATION AND ACCEPTANCE TEST..............................................................................................21
9. COMMISSIONING MEMORANDUM.........................................................................................................22
10. ATTACHEMENT.........................................................................................................................................23
Microwave (IP Radio)
Commissioning Test

1. SITE INFORMATION

Local Station Remote Station


Site Item
(Near End) (Far End)
Site Name COMBAT KANEYAN TARERAN
Site ID COI 934 TDO007
Address Desa Kaneyan Desa Rumoong
KELURAHAN

KECAMATAN Tareran Tareran


KABUPATEN / PROVISINSI Minahasa Selatan Minahasa Selatan
Site Type (3G or 2G) 2G /3G/4G 2G /3G/4G

*please put site name and site ID

1.1. Site Detail:

ITEM NEAR END FAR END


Coordinate Latitude : 01 13 20.31 N Latitude : 01 13 43.75 N
Longitude :124 40 33.00 E Longitude : 124 43 30.00 E
Path Distance (km) 5.52 Km 5.52 Km
Type of Site Cabin / Room Reno / Cabin / Room Reno /
Roof Top Cabin / Outdoor Roof Top Cabin / Outdoor
Type of Structure Triangular / Guyed Mast / Triangular / Guyed Mast /
Mini Structure / Building / Mini Structure / Building /
Self Supporting Tower Self Supporting Tower

Tower/Building Height (m) 42 m 72 m


Antenna Height (m) 40 m 65 m
Station Height ASL 381.00 m 643.84 m
Azimuth (° ) 82.50 ° 262.50 °

*Please choose only one of Site type Cabin / Room Reno / Roof Top Cabin / Outdoor

* Please choose only one of Structure type Triangular/Guyed Mast/Mini Structure/Building/Self Supporting Tower
Microwave (IP Radio)
Commissioning Test

2. EQUIPMENT INFORMATION

Local Station Remote Station


Site Item
(Near End) (Far End)
NE ID COI934 TDO007
Equipment Name COMBAT KANEYAN TARERAN
Equipment Type Ipasolink Ipasolink
Emission Class IDU VR_4 IDU VR_4(Nodal)
Link Capacity (M) 400Mbps 400Mbps
Modulation 256QAM 256QAM
System Configuration 2+0 SP 2+0 SP
High / Low Station Low High
Antenna Diameter (meter) 0.6 1.2
Antenna Type Andrew Andrew
Antenna Gain - -
Antenna Polarization (H or V) V V
Antenna Minimum Frequency Range(MHz)
Antenna Maximum Frequency Range(MHz)
E1 Cable Length (meter) - -
LAN Cable length (meter) - -
IF Cable Length (meter) 120 165
ODU Sub-Band M/J M/J

2.1. Outdoor:

NEAR END FAR END


Standby / Standby /
Main Main
Diversity Diversity
SN Outdoor Unit (ODU) 000011764 000011686 000011152 000012346
SN Hot-Standby Coupler - - - -
Antenna Serial No. BURAM - MBTMA0200047N4100018 -
Microwave (IP Radio)
Commissioning Test

2.2. Indoor:
NEAR END FAR END
Standby / Standby /
Main Main
Diversity Diversity
IDU Serial No. 00154758 - 00125497 -
Hybrid System Control and
Cross-connect Board (CSH) Serial - - - -
No.
Fast/Gigabit Ethernet (GBE) - - - -
Board Serial
Fan Unit Serial No. 00144592 - 00122930 -
Tributary Card Serial No. - - - -
*If no need test, fill in N/A

3. INSTALLATION INSPECTION
3.1. Outdoor:
Local Station Remote Station
Item Inspection list Remarks
(Near End) (Far End)
The fixation of antenna is reliable. The
mechanical accessories of antenna should be
installed correctly. All connecting bolts in the
3.1.1
rack and antenna are installed correctly and □Passed □Failed □Passed □Failed
firmly. Flat washers and spring washers are
installed in a correct order.
Position 35.0m(AGL) Position 35.0m (AGL)
Antenna is installed at required position and
3.1.2
height. □ Passed □ Failed □Passed □Failed
Antenna Polarization is followed correctly
3.1.3
according to the design. □Passed □Failed □Passed □Failed
Antenna drainhole cover is removed on the
3.1.4
bottom of the antenna. □Passed □Failed □Passed □Failed
The ODU is properly mounted to Antenna /
3.1.5 Hybrid Coupler. ODU latches must be properly □Passed □Failed □Passed □Failed
locked on Antenna / Hybrid Coupler hook.
ODU Grounding is installed and the grounding
3.1.6
cable is properly tightened on grounding point. □Passed □Failed □Passed □Failed
The ODU and IF cable should be connected
3.1.7 reliably and the water-proof treatment should
□Passed □Failed □Passed □Failed
be well.
IF cable is properly installed and fixed. The IF
3.1.8
cable route follows according to the plan. □Passed □Failed □Passed □Failed
IF Cable Grounding Kit is properly installed and
3.1.9 fixed. Grounding Kit is properly terminated and □Passed □Failed □Passed □Failed
tightened on grounding point.
IF Cable Grounding Kit with proper water-proof
3.1.10
treatment. □Passed □Failed □Passed □Failed
3.1.11 IF Cable is labeled correctly on both end. □Passed □Failed □Passed □Failed
*3.1.2 please fill actual antenna height installed
Microwave (IP Radio)
Commissioning Test

3.2. Indoor:
Local Station Remote Station
Item Inspection list Remarks
(Near End) (Far End)
3.2.1 IDU is properly installed on the rack.
□Passed □Failed □Passed □Failed
IDU grounding is installed and
3.2.2
properly connected to the □Passed □Failed □Passed □Failed
grounding point.
IDU power cable is properly
3.2.3
connected to power distribution □Passed □Failed □Passed □Failed
source circuit breaker.
IDU power cable is labeled on both
3.2.4 ends correctly. Circuit breaker □Passed □Failed □Passed □Failed
assignment installed with proper
label.
E1 Traffic Cable is properly installed
3.2.5 and correctly terminated on DDF. E1 □Passed □Failed □Passed □Failed
Traffic cable properly fastened.
E1 Traffic Cable is correctly labeled
3.2.6 on both ends. DDF block with □Passed □Failed □Passed □Failed
correct label and assignment.
IF Jumper cable connector properly
installed and tightened. IF cable and □Passed □Failed □Passed □Failed
3.2.7
IF cable jumper connection fixed
and tightened properly.
3.2.8 IF Jumper cable correctly labeled.
□Passed □Failed □Passed □Failed
Ethernet Cable properly wired
3.2.9
and connected. □Passed □Failed □Passed □Failed
Optical Fiber correctly installed
3.2.10
and routed properly. □Passed □Failed □Passed □Failed
IDU Fan Units & other cards/module
3.2.11 are installed properly. All panel □Passed □Failed □Passed □Failed
screws have appropriate tightness.
3.2.12 IDU and IF Cards properly labeled.
□Passed □Failed □Passed □Failed
All cables and connectors
3.2.13
properly labeled. □Passed □Failed □Passed □Failed
Microwave (IP Radio)
Commissioning Test

4. Link Budget TEGALROTAN


COI934 Combat Kaneyan TDO007 Tareran
41.96
KOMPLEKASTEK 06 17 01.14 S643.84
Elevation (m) 381.00
Latitude 01
13 20.31 N 106 43
0126.39 E
13 43.75 N
37.64
Longitude 124
40 33.00 E 124269.84
43 30.00 E
True azimuth (°) 06 17
01.54 S
82.50 0.03262.50
Vertical angle (°) 106 40
58.80 E 2.97 -3.00
89.85 A15S06HAC
Antenna model -0.06
VHLP4-142 VHLP4-142
27.00
Antenna height (m) 40.00 36.80 65.00
Antenna gain (dBi) 42.90 0.50 42.90
0.50
Miscellaneous loss (dB) 3.50 3.50

Frequency (MHz) 14775.00


Polarization Vertical
Path length (km) 5.52
Free space loss (dB) 130.70
Atmospheric absorption loss (dB) 0.15
Net path loss (dB) 52.04 52.04

Radio model iPASO IHG 15G 220MB iPASO IHG 15G 220MB
TX power (watts) 0.13 0.13
TX power (dBm) 21.00 21.00
EIRP (dBm) 60.40 60.40
Emission designator 28M00D7W 28M00D7W
RX threshold criteria BER 10-6 BER 10-6
RX threshold level (dBm) -67.50 -67.50
Maximum receive signal (dBm) -20.00 -20.00

RX signal (dBm) -31.04 -31.04


Thermal fade margin (dB) 36.46 36.46
Dispersive fade margin (dB) 49.00 49.00
Dispersive fade occurrence factor 1.00
Effective fade margin (dB) 36.22 36.22

Geoclimatic factor 8.22E-05


Path inclination (mr) 52.11
Fade occurrence factor (Po) 1.63E-05
Average annual temperature (°C) 10.00

Worst month - multipath (%) 100.00000 100.00000


(sec) 0.01 0.01
Annual - multipath (%) 100.00000 100.00000
(sec) 0.03 0.03
(% - sec) 100.00000 - 0.06

Rain region ITU Region P


0.01% rain rate (mm/hr) 145.00
Flat fade margin - rain (dB) 36.46
Rain rate (mm/hr) 173.91
Rain attenuation (dB) 36.46
Annual rain (%-sec) 99.99469 - 1674.68
Annual multipath + rain (%-sec) 99.99469 - 1674.74

Tue, Jan 02 2024


COI934 team 1jan23-TDO007 Tareran_40-65_max veg 30m_15g 2+0 0.6-1.2 - OA.pl4
Reliability Method - ITU-R P.530-7/8
Rain - ITU-R P530-7
Microwave (IP Radio)
Commissioning Test

PathProfile

750

700

650

600
Elevation (m)

550

500

450

400

350
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
Path length (5.52 km)
COI934 Combat Kaneyan Frequency (MHz) = 14775.0 T DO007 T areran
Latitude 01 13 20.31 N K = 1.33 Latitude 01 13 43.75 N
Longitude 124 40 33.00 E %F1 = 100.00 Longitude 124 43 30.00 E
Azimuth 82.50° Azimuth 262.50°
Elevation 381 m ASL Elevation 644 m ASL
Antenna CL 40.0 m AGL Antenna CL 65.0 m AGL

Jan 02 24

5. TEST ITEMS AND FORMS

5.1. Test Items for Preliminary Test


Interface and System Test Item Test Sub-Item

1.Hybrid Interface test Optical interface test Mean launched power

Actual received optical power

Ethernet interface test Ethernet service connectivity test

E1 interface test Bit error test (10minutes)

2.IF/RF test RF parameter configuration Actual transmit frequency of the ODU

Actual receive frequency of the ODU

Actual transmit power of the ODU

Actual receive power of the ODU

Microwave protection HSB switching


Microwave (IP Radio)
Commissioning Test

List of Test Tool

Test Equipment

1. Optical Power Meter

2. E1 BER Tester

3. Laptop, USB TO SERIAL CONNECTOR

4. Spectrum Analyzer

5. Power Meter

5.2 Optical Interface Test

i. Mean Launch Power


1. Objective

- To measure optical transmit power from the board to determine STM1 optical interface board

performance

2. Configuration

Optical
OptiX RTN Tx
power
IDU
equipment meter

Figure 1 Configuration for testing the mean launched power

ii. Actual Received Optical Power


1. Objective

- To measure optical receive power from other board/cards to determine whether the receive power is

within the STM1 optical interface board performance

2. Configuration

Rx
IDU HW OSN

Optical
power
meter

Figure 2 Configuration for testing the actual received optical power

OptiX RTN
equipment
Microwave (IP Radio)
Commissioning Test

TEST RESULTS (Item 5.2.1 & 5.2.2):

NE ID/ Name N/A

Board Type Port Number

Test Item Result Expected Result Remarks


(dBm) (dBm) (Passed / Fail)

1.Launched Max -8.00


optical power ( N/A )/( N/A ) N/A
Min -15.00

2.Received Max -8.00


optical power ( N/A )/( N/A ) N/A
Min -28.00
5.3. Ethernet interface Test

i. Ethernet Service Connectivity Test


1. Objective

- To confirm and check Connectivity Test on ELL/Ethernet Services

2.Configuration

Figure 5 Network of the Ethernet service connectivity test

3. Procedure
- Configure a normal date service for the equipment to be tested.
- Ping the personal computer (PC) or Ethernet equipment that is connected to the
Ethernet board of NE2 by using the PC that is connected to the Ethernet board of
NE1.The ping operation should be successful and the response message should be
returned within the specified time.
Note:
0% cek di hasil
TEST RESULTS (Item 5.3.1): ping test 
Packet Loss
Result Expected Result REMARKS
(Passed/Fail)
Site Name Sub Item

Site Name Packet Loss 0% < 0.1% Passed


Jitter N/A < 5 ms N/A
Round Trip Delay N/A < 40 ms N/A
Latency N/A < 10 ms N/A
Indexes:

No Bit errors should exist

Remarks:
5.4 E1 interface test

5.4.1 Bit Error Test (10minutes) – (all 2M ports cascaded)


1. Objective

- To confirm and check BER Test on all 2M Services

2. Configuration

Figure 4 Bit error test diagram

3. Procedure

- Configure a normal service for the equipment to be tested.

- Loopback from far end site,Use a 2 Mbit/s bit error rate (BER) tester to perform the
24-hour bit error test.
Note:
10 -12 xcek hasil ber
TEST RESULTS (Item 5.4.1):
-9 test  Bit Errors
0.0e-12
Test Sub-Item 10minutes Bit Error Test

Test Value Conclusion


-12
PORT 1 ~ PORT X 10 Passed
Index: Note:
No Bit errors should exist 00.000 ms xcek
hasil ber test
Remarks: N/A
Errored Second
00.000

Test Sub-Item 24 Hours Bit Error Test

Result Expected Result Remark


(Passed/Fail)

Errored Second(ES) 00.000 ms < 2 ms N/A


5.5 RF Parameter Configuration
5.5.1 Objective

To check and query the ODU Transmit Frequency , ODU Transmit Power (Actual and Maximum),
ODU Receive Frequency and ODU Receive Power (Actual and when opposite station on maximum power).

5.5.2 Requirements

The ODU interface information should be configured for every ODU, and the ODU interface
information includes transmit frequency (MHz), T/R spacing (MHz) and transmit power (dBm).

5.5.2 Procedure: Carry out the test as follows.

1 Query the actual transmit frequency of the ODU on the site & LCT.

2 Query the actual receive frequency of the ODU on the site & LCT.

3 Query the actual transmit power of the ODU on the site & LCT.

4 Query the actual receive power of the ODU on the site & LCT.

5 Query the maximum transmit power of the ODU on the site & LCT.

Query the receive power of the ODU on the site & LCT (when opposite is on max
6
power).

Test Result:

Local Station: Near End

Test Item Query Results Expected Result Conclusion


(Main/Standby/Diversity)
(Passed / Fail)

1.Actual transmit frequency (GHz) Passed


14753.000 / 14417.000 (15Ghz)

2.Actual receive frequency (GHz) Passed


15243.000 / 14907.000 (15Ghz)

3.Max transmit power (dBm) 21 Passed


21
4.Receive power when opposite Passed
- -
site is on max power (dBm)

5.Minimum transmit power (dBm) - -


-
6.Receive power when opposite -
- -
site is on min power (dBm)

7.Actual transmit power (dBm) 20 Passed


20
8. Actual receive power (dBm) Passed
-38.6 /38.9 (±3dBm) -38.9 / -40.1. (±3dBm)

9. Channel Bandwidth (MHz) 28 Passed


28
10.Modulation Passed
256QAM 256QAM
Remote Station: Far End

Test Item Query Results Expected Result Conclusion


(Main/Standby/Diversity)
(Passed / Fail)

1.Actual transmit frequency (kHz) Passed


15243.000 / 14907.000 (15Ghz)

2.Actual receive frequency (kHz) Passed


14753.000 / 14417.000 (15Ghz)

3.Max transmit power (dBm) 21 Passed


21
4.Receive power when opposite Passed
- -
site is on max power (dBm)

5.Minimum transmit power (dBm) - -


-
6.Receive power when opposite -
- -
site is on min power (dBm)

7.Actual transmit power (dBm) 20 Passed


20
8.Actual receive power (dBm) Passed
-40.1 / -38.9 (±3dBm) 38.6 / -38.9 (±3dBm)

9. Channel Bandwidth (MHz) 28 Passed


28
10.Modulation Passed
256QAM 256QAM
5.6 Microwave Protection

5.6.1 N+1 HSB Switching (Hot Standby Backup)


1. Objective

- To check microwave protection using the hot standby backup switching


between main and standby IF cards/ODU. To check and verify revertive and
non-revertive swiching mode functions.

2. Requirements
To configure two IF boards and the connected ODUs as a 1+1 protection group
to protect the IF board and the ODU.

3. Configuration
Use the SDH analyzer or other tester that can monitor bit errors as the test meter.

ODU1 ODU3
Microwave Link
NE1 NE2 IDU

IDU

ODU4
ODU2
Tester

Figure 3 Configuration for testing the HSB switching

4. Procedure: Carry out the test as follows.


Configuration of the HSB Protection Group:
1 Configure the HSB switching mode on the LCT and disable the reverse switching. On the local
equipment side, connect one of the E1 port or STM1 port to the BER tester. On the opposite
equipment side, perform hardware or software inloop to the E1 port. Use the BERT to detect bit
errors.
HSB Automatic Switching (IF card fault simulation):
On the active intermediate frequency (IF) board of the network element (NE) on the local site, power
2 off the ODU. There will be few bit errors during the switching. The test result should be that the
service recovers after transient interruption. The switching time is approximately less than 50ms.
After the switching is completed, test the bit errors for 5-10 minutes. The test result should be that
there are no bit errors.

On the active IF board, power on the ODU. Deliver the switching clearing command. Make sure that
3
the protection group is in the Normal state.

HSB Automatic Switching (ODU fault simulation):


On the active intermediate frequency (IF) board of the network element (NE) on the local site, set the
4 main ODU power to mute. There will be few bit errors during the switching. The test result should be
that the service recovers after transient interruption. After the switching is completed, test the bit
errors for 5-10 minutes. The test result should be that there are no bit errors.

On the active IF board, remove the mute of the main ODU. Deliver the switching clearing command.
5
Make sure that the protection group is in the Normal state.

HSB Manual Switching:


6 Deliver the manual switching command using LCT. Check the result of the bit error test. The test
result should be that the service recovers after transient interruption.

Revertive Switching Mode:


Set the switching mode of the IF 1+1 protection to revertive. Use the BER tester to retest the bit
7 errors. If the recovery time starts and is realized, the NE releases the switching and causes the
former working channel to return to the working state. The test result should be that after the
switching, the service recovers after transient interruption. The wait-to-restore time is 600s by default.

Non-Revertive Switching Mode:


8 Set the switching mode of the IF 1+1 protection to non-revertive. When an NE is in the switching
state, the NE keeps the state of the former working channel unchanged even though it is restored to
normal unless another switching occurs.

Alarm Indication during Switching:


9 After switching is realized, below are the alarm indications:
Switching triggering alarm indication:

10 On the opposite site, refer to steps 1-8 to test the IF 1+1 switching of the opposite equipment.
TEST RESULTS (Item 5.6.1):

Test Sub-Item HSB Switching

Site ID. Function Test Test Results (Passed/Fail)

Configuration of the HSB protection group N/A


HSB Automatic switching (IF Card & ODU
Simulation)
N/A

Local site: Manual switching N/A


Revertive Switching Mode N/A
Non-revertive Switching Mode N/A
Switching Alarm Indication N/A
Configuration of the HSB protection group N/A
HSB Automatic switching (IF Card & ODU
Simulation)
N/A

Far end site: Manual switching N/A


Revertive Switching Mode N/A
Non-revertive Switching Mode N/A
Switching Alarm Indication N/A
Indexes:
*After the switching is completed, there will be few bit errors during the switching. The test result should be
that the service recovers after transient interruption.
**For the non-revertive switching mode, set the switching mode to non-revertive before performing the Manual
Switching. After the switching is completed, power on the ODU of the non-active IF card and observe.

Remarks:
6. INSTALLATION PHOTOGRAPH

Outdoor:

Near End Far End

Site View (Full) OK OK


Waveguide termination Antenna OK OK
ODU OK OK
Wind Brace termination Antenna OK OK
Tower Member OK OK
IF & Grounding termination at ODU
OK OK

Grounding kit OK OK
Vertical cable routing (top to bottom)
OK OK

Horizontal cable routing towards cabin


OK OK

Cable entry view OK OK

Indoor:

Near End Far End


o
Modem Rack 45 View OK OK

Near View (front) OK OK

Modem Rack Rack OK OK


Grounding
termination
OK OK
MGB

Power Termination OK OK
MCB / DCPDB
Tributary DDF OK OK
7. PING TEST

Test Ping NE : COMBAT KANEYAN


Test Ping FE: TARERAN

*If no item, fill in N/A


Hardware Installation and Acceptance Test

Site ID: COI934 Site Name: COMBAT KANEYAN

Target
Inspection
Items Description Completion Checked by
Date
Date

Site ID: TDO007 Site Name: TARERAN

Target
Inspection
Items Description Completion Checked by
Date
Date

NEC Representative: TELKOM Representative (Operation):

RANGGA SANJAYA
COMMISSIONING MEMORANDUM
(COI934) COMBAT KANEYAN – (TDO007) TARERAN

This is to certify that Commissioning Test for the above mentioned link is
successfully completed and the supplied equipment/system conforms with the
contractual obligations.

The above works were Inspected and Accepted by


TELKOM

RANGGA SANJAYA Name :


Name :

Signature Signature

Date :
Date :
LAMPIRAN:
1. CAPTURE
IPASO CAPTURE for New Link/Upgrade 2nd Pol./Redeploy
1.1 Current Status
1.2 Equipment Configuration
2.1 Radio Configuration
2.2 Current Metering
3.1 IP Address Setting
3.2 Modem Port Setting
4.1 Ethernet Port Setting
4.2 VLAN Setting
5.1 Equipment Inventory Information (IDU)
5.2 Equipment Inventory Information (ODU)
6.1 S/W License Information
6.2 Interference Check Metering

IPASO CAPTURE for Upgrade

1.1 Current Status Before

1.2 Current Status After

2.1 Equipment Configuration Before

2.2 Equipment Configuration After

3.1 Radio Configuration Before

3.2 Radio Configuration After

4.1 Current Metering Before

4.2 Current Metering After

5.1 S/W License Information Before

5.2 S/W License Information After

2. PHOTOGRAPHS
3. AS BUILT DRAWING
AS BUILT DRAWING for New Link/Upgrade 2nd Pol./Redeploy
1.3.1 Site Layout (Capture dari Google Map)
1.3.2 Equipment Room Layout
1.3.3 Indoor Tray and Cable
1.3.4 Rack IDU, DDF, and MCB
1.3.5 Antenna Placement information

You might also like