You are on page 1of 3

Project Job Ref.

Section Sheet no./rev.


1
Calc. by Date Chk'd by Date App'd by Date
P 28-Mar-24

ANCHOR BOLT DESIGN


In accordance with ACI318-19 (22)
Tedds calculation version 2.1.09

Design summary
Description Unit Required Provided Util. Result
Anchor tensile strength (kN) 55.60 134.83 0.412 PASS
Concrete breakout (kN) 155.70 247.68 0.629 PASS
Pullout strength (kN) 55.60 74.79 0.743 PASS

Anchor bolt geometry


Type of anchor bolt; Cast-in headed end bolt anchor
Diameter of anchor bolt; da = 25 mm
Number of bolts in x direction; Nboltx = 2
Number of bolts in y direction; Nbolty = 2
Total number of bolts; ntotal = (Nboltx  2) + (Nbolty - 2)  2 = 4
Total number of bolts in tension; ntens = (NboltN  2) + (Nbolty - 2)  2 = 4
Spacing of bolts in x direction; sboltx = 305 mm
Spacing of bolts in y direction; sbolty = 305 mm
Number of threads per inch; nt = 8
Effective cross-sectional area of anchor; Ase =  / 4  (da - 0.9743 in / nt)2 = 391 mm2
Embedded depth of each anchor bolt; hef = 305 mm
Foundation geometry
Member thickness; ha = 508.0 mm
Dist center of baseplate to left edge foundation; xce1 = 889 mm
Dist center of baseplate to right edge foundation; xce2 = 813 mm
Dist center of baseplate to bot. edge foundation; yce1 = 635 mm
Dist center of baseplate to top edge foundation; yce2 = 686 mm
Material details
Minimum yield strength of steel; fya = 248.2 N/mm2
Nominal tensile strength of steel; futa = 460.0 N/mm2
Compressive strength of concrete; f’c = 21 N/mm2
Concrete modification factor;  = 1.00
Modification factor for cast-in anchor concrete failure
a = 1.0  = 1.00
Strength reduction factors
Tension of steel element; t,s = 0.75
Shear of steel element; v,s = 0.70
Concrete tension; t,c = 0.65
Concrete shear; v,c = 0.70
Concrete tension for pullout; t,cB = 0.70
Concrete shear for pryout; v,cB = 0.70
Project Job Ref.

Section Sheet no./rev.


2
Calc. by Date Chk'd by Date App'd by Date
P 28-Mar-24

Anchor forces
Number of bolt rows in tension; NboltN = 2
Axial force in bolts for row 1; N1 = 111.20 kN
Axial force in bolts for row 2; N2 = 44.50 kN
Total axial force on bolt group; NR = 155.70 kN
Maximum axial force to single bolt; Nmax,s = 55.60 kN
Eccentricity of axial load (from bolt group centroid); e’N = 65 mm
Shear force applied to bolt group; V = 0.00 kN
Steel strength of anchor in tension (17.6.1)
Nominal strength of anchor in tension; Nsa = Ase  futa = 179.77 kN
Steel strength of anchor in tension; Nsa = t,s  Nsa = 134.83 kN
PASS - Steel strength of anchor exceeds max tension in single bolt
Check concrete breakout strength of anchor bolt in tension (17.6.2)
533

155.70 kN

A A
305

305
508
483

737 305 660 1702

Plan on foundation Section A-A


Concrete breakout - tension

Coeff for basic breakout strength in tension; kc = 10


Breakout strength for single anchor in tension; Nb = 3.9  a  (f'c  1 N/mm2)  hef5/3  1 mm1/3 = 244.95 kN
Projected area for groups of anchors; ANc = 1486449 mm2
Projected area of a single anchor; ANco = 9  hef2 = 836127 mm2
Min dist center of anchor to edge of concrete; ca,min = 483 mm
Mod factor for groups loaded eccentrically; ec,N = min(1 / (1 + ((2  e'N) / (3  hef))), 1) = 0.875
Modification factor for edge effects; ed,N = 1.0 = 1.000
Modification factor for no cracking at service loads; c,N = 1.000
Modification factor for cracked concrete; cp,N = 1.000
Nominal concrete breakout strength; Ncbg = ANc/ ANco  ec,N ed,N  c,N  cp,N  Nb = 381.05 kN
Concrete breakout strength; Ncbg = t,c  Ncbg = 247.68 kN
PASS - Breakout strength exceeds tension in bolts
Pullout strength (17.6.3)
Net bearing area of the head of anchor; Abrg = 645 mm2
Mod factor for no cracking at service loads; c,P = 1.000
Pullout strength for single anchor; Np = 8  Abrg  f'c = 106.85 kN
Nominal pullout strength of single anchor; Npn = c,P  Np = 106.85 kN
Pullout strength of single anchor; Npn = t,cB  Npn = 74.79 kN
PASS - Pullout strength of single anchor exceeds maximum axial force in single bolt
Project Job Ref.

Section Sheet no./rev.


3
Calc. by Date Chk'd by Date App'd by Date
P 28-Mar-24

Side face blowout strength (17.6.4)


As hef <= 2.5  min(ca1, ca2) the edge distance is considered to be far from an edge and blowout strength need not be
considered