You are on page 1of 2

These repair instructions are for NON WARRANTY repairs only!

Please make visual inspection for signs of corrosion or mechanical damages before
starting.

Ethernet doesn’t work, drops ping packets.

Check Ethernet cable, NOT OK Change faulty cable


Ethernet connector or connector

OK

NOT OK
Check diodes D23,D24 Change D23, D24

OK

Check temperature of
NOT OK Change faulty
U9 (for eth1),U13 (for eth2)
components
It should be less than 40C

If the problem still appears the board is unrepairable


Reference Part number Manufacturer Description
number
D23, D24 STPS2L60A ST Schottky Diode 60V, 2A, SMA
U9,U13 DP83816AVNG National 10/100Ethernet Controller