(MFT tire alarm system Tee SEM LE em TT dedi OTOL | [ Features: + UL listed to standard 864, 9th edition + NFPA Styles 4, 6, and 7 applicable for signal ine circuit + Status LEDs for shor circuit condition notification + Down-sized unit ® + Easy instalation USTED ‘The short cicuit isolator module provides the system with an abilly to monitor and isolate the short circult part of wiring fon the addressable Signal Line Circuit (SLC) loop. The module does not have any address number so that address setting for this module is not required. ‘The module is connected on addressable SLC loop of Main Control Unit (MCU) andor Sub Control Unit (SCU}. The module supports NFPA Style 4, 6, and 7 wiring methods. (SCI is not mandatory in Styles 4 and 6.) The necessary 5 V power is generated from the 24 VDC power on SLC loop of MCU or SCU using a constant voltage circuit. ‘The short cicuit isolator module detects the short circuit and the recovery of short circuit by monitoring the voltage of assigned wiring on SLC loop. In normal condition, the module connects S+1 to S+2. When the voltage of wiring on SLC. loop goes below 3.7 V the module judges it as short circuit condition so that the module disconnects $#1 from S+2 by activating the isolation circuit. When the voltage goes above 3.7 V the module judges it as no short circuit condition (i. recovery of short circuit) so that the module connects S+1 to S+2 by deactivating the isolation circuit ‘The module contains two red LEDs. The LEDs indicate normal monitoring operation of the unit when they are turned off When a short circuit is detected in the wiring connected to S+1 and S-1 terminals the LED for $1 trouble turns on to Indicate its isolation. Likewise, the LED for S2 trouble turns on when a short circuit is detected in the wiring connected to ‘S#2 and S-2. The LEDs extinguish when the short citcuits are recovered in due course. Erno + Model no. FQIO1UA ISnin Ne em ‘Specification 1__| Rated volage range of SLC input power 7.81030,7 VDC 2 _| Maximum SLC 24 VDC standby current 250 WA '3_| Maximum SLC 24 VDC astve current 1.85 mA | Inornalresstanco O18) 5 | Applicable SLC wing sie NEPA Siyies 4,6, and? | Wiring resistance of wring afteran SCInSiyle4 | 10.0 7 _ | Witing resistance of wiring between an SCI and another SClin Siyles 6 and 7 toa @ | Max. na of SClon an SLC loop in Style @ aunts | Max na of SClan an SLC Toop in Siyles 6 and7_| 128 units ‘Maximum no. of addressable devices bolween an 10 | sctand another SCI on an SLC loop Sounis 11_| Operating temperature range: 2 t9 120 F (0104970) 12 | Operating humidity range 0 10 88% (Non-condensing) 13 | Dimensions “43mm (444°) (H) x 119mm (448°) (W) x 25mm (0.987) (D) North American 2-1/2" (64mm) deep 2-gang box 14 | Applicable electrical box fr instalation Standard 4” square box 1-1/2" (38mm) deep box Integlex fire alarm system Catalog Number 08021000-F-11103Y01 NoHMTBOSAILTD. Installation and wiring inform: chs = ea Wiring in NEPA Style 7 Wiring in NFPA Style 4 (example) Installation in an electrical box Installation on a plane place + These instructions do not purport to cover all the details or variations in the equipment described, nor provide for every possible contingency to be met in connection with installation, operation and maintenance. + Specifications are subject to change without notice. Contact Nohmi before relying on above specifications. + Actual performance is based on proper application of the product by a qualified professional + Should further information be desired or should particular problems arise, which are not covered sufficiently for the purchaser's purposes, the matter should be referred to Nohmi or a distributor in your region, \ (SFUIVY con NOHM BOSAI LTD. + Head Office: 4-7-8 Kudan-Minami, Chiyoda-ku, Tokyo 102-8277, Japan + Phone:(81)3-3265-0231 +F A X:(81)3-3265-5348 URL http:/imwwnohmi.cajpfenglishy

You might also like