You are on page 1of 6

Hindawi

Applied Bionics and Biomechanics


Volume 2023, Article ID 9806180, 1 page
https://doi.org/10.1155/2023/9806180

Retraction
Retracted: Clinical Application of a Safe Blood Sampling
Device with an Indwelling Needle

Applied Bionics and Biomechanics


Received 19 December 2023; Accepted 19 December 2023; Published 20 December 2023

Copyright © 2023 Applied Bionics and Biomechanics. This is an open access article distributed under the Creative Commons
Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is
properly cited.

This article has been retracted by Hindawi following an investi- The corresponding author, as the representative of all
gation undertaken by the publisher [1]. This investigation has authors, has been given the opportunity to register their agree-
uncovered evidence of one or more of the following indicators of ment or disagreement to this retraction. We have kept a record of
systematic manipulation of the publication process: any response received.

(1) Discrepancies in scope References


(2) Discrepancies in the description of the research reported
[1] Y. Deng, Z. Lv, Y. Cheng, A. Liu, and Z. Huang, “Clinical
(3) Discrepancies between the availability of data and the Application of a Safe Blood Sampling Device with an Indwelling
research described Needle,” Applied Bionics and Biomechanics, vol. 2022, Article ID
(4) Inappropriate citations 6362905, 5 pages, 2022.
(5) Incoherent, meaningless and/or irrelevant content
included in the article
(6) Manipulated or compromised peer review

The presence of these indicators undermines our confidence


in the integrity of the article’s content and we cannot, therefore,
vouch for its reliability. Please note that this notice is intended
solely to alert readers that the content of this article is unreliable.
We have not investigated whether authors were aware of or
involved in the systematic manipulation of the publication
process.
In addition, our investigation has also shown that one or
more of the following human-subject reporting requirements
has not been met in this article: ethical approval by an Institu-
tional Review Board (IRB) committee or equivalent, patient/
participant consent to participate, and/or agreement to publish
patient/participant details (where relevant).
Wiley and Hindawi regrets that the usual quality checks did
not identify these issues before publication and have since put
additional measures in place to safeguard research integrity.
We wish to credit our own Research Integrity and Research
Publishing teams and anonymous and named external
researchers and research integrity experts for contributing to
this investigation.
Hindawi
Applied Bionics and Biomechanics
Volume 2022, Article ID 6362905, 5 pages
https://doi.org/10.1155/2022/6362905

Research Article
Clinical Application of a Safe Blood Sampling Device with an
Indwelling Needle

E D
Yeqin Deng ,1 Zhengbing Lv ,2 Yue Cheng,1 Annuo Liu ,3 and Zhengling Huang1
1
2
3
Zhejiang Sci-Tech University, Hangzhou, Zhejiang, China
School of Nursing, Anhui Medical University, Hefei, Anhui, China

T
Anhui Maternal and Child Health Hospital, Anhui Medical University, Hefei, Anhui, China

C
Correspondence should be addressed to Yeqin Deng; dyq85213@126.com and Zhengbing Lv; zhengbingl@zstu.edu.cn

Received 20 June 2022; Revised 27 July 2022; Accepted 2 August 2022; Published 1 September 2022

A
Academic Editor: Ye Liu

Copyright © 2022 Yeqin Deng et al. This is an open access article distributed under the Creative Commons Attribution License,
which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

R
Background. The traditional indwelling needle catheter is hard and can only complete one puncture at a time. The safety and
indwelling needle catheter is soft, with a large lumen, with high success rate of blood collection, and one puncture completes
two operations, so it is of important value and significance to study the new safety and indwelling needle. To explore the
clinical utility of a novel blood collection device with indwelling needle for blood collection among pediatric patients. Methods.

T
A total of 300 children who were admitted to the children’s hospital from March to June 2020 were selected and randomly
divided into the control group (148) and the observation group (152). The control group received venipuncture using regular
needles for infusion and blood collection. For the observation group, a modified indwelling needle device was used for the
procedures. Comparisons were made between the two devices in five aspects: blood sample quality, operation time, needlestick
incidence, related complications, and patient satisfaction. Results. There was no significant difference in coagulation rate

E
between the two groups, but slightly lower overall hemolysis incidence in the observation group. The unqualified rate of blood
specimens collected in the observation group was 10.0% lower than that in the control group (P < 0:05). Shorter operation
time, lower incidence of needlestick injuries, and improved satisfaction were observed in the group using the novel blood
collection device. Conclusions. This modified blood collection device is superior to the regular venipuncture needle, in terms of
safety, efficiency, and patient satisfaction; thus, it has potential for broad clinical applications for infusion and blood collection.

1. Introduction

R
Intravenous (IV) infusion and blood sampling are routine
and important procedures for sick children for timely diag-
nosis and effective treatment, and most hospitalized children
need vessel puncture and blood sampling. An intravenous
catheter has been most commonly used clinically as a blood
sampling device, allowing long venous access with simple
procedure [1]. Studies show that the incidence of needlestick
injury among nurses in China was 57.3% [2]; the incidence
among intern nurses is even higher, about 60.8% [3]. Safety
Connecting a syringe to the catheter valve for blood collec-
tion is cumbersome and typically involves multiple steps. It
also has many disadvantages such as repeated disconnection,
difficult to control blood volume, easy infection, and blood
clotting [6]. When collecting blood samples from children
using the IV catheter, it is easier to make mistakes and inflict
needlestick injuries since they are often uncooperative, rest-
less, and crying [7].
To this end, we have developed a novel blood sampling
device that is more convenient and simple-to-operate and
reduces the possibility of clinical complications. In this
needles can be selected to effectively avoid such accidents [4, paper, the safe and traditional indwelling needle design has
5]. Traditional blood sampling devices need to press open a thinner needle tube, a softer catheter, and a larger lumen
the catheter valve inward to facilitate inserting a syringe into and greatly improved the success rate of blood collection,
the valve in order to draw blood. The blood sample in the and one puncture can complete two tasks. We evaluate the
syringe is then injected into the sample collection tube. safety and utility of this blood collection device among
2 Applied Bionics and Biomechanics

pediatric patients for infusion and blood sampling proce-


dures in contrast with regular intravenous catheters.

D
2. Design of the Blood Collection Device
A common intravenous catheter was used for a regular
blood collection procedure, which is composed of a 22-

E
24G needle at the top connected with a 5 mL syringe, plus
a blood drawing syringe with a heparin cap connected with
a vacuum collection tube (Figure 1). The details of new
design are shown in Figure 2, comprised of a negative pres-

T
sure large-diameter tube (part 1) attached at the end that can Figure 1: Regular blood collection catheter with a syringe attached.
hold and protect the puncture needle (part 2), the connect-
ing soft tubing to the needle (part 3), the puncture needle
sheath (part 4), and a threaded adapter (part 5) at the other
end suitable for Y type or non-Y type indwelling needle con-

C
nection. Type Y is an indwelling needle with two exits, usu-
ally with an extension tube: one outlet for injection and one
with a heparin cap; non-Y type is handling indwelling nee-
dles other than Y type and the male (part 6) and female
buckle (part 7) at the exterior of the soft tubing. The assem-

A
bled device with all parts is shown in Figure 3. This new
design is more efficient and safer for clinical tasks of blood
collection and infusion for pediatric patients who often
require both procedures and suffer repeated needle punc-
tures, as both procedures can be achieved in a one-time nee-

R
dle puncture. To avoid contamination of saline or Figure 2: The structural view of the new blood collection device.
anticoagulant in collected blood sample, a single or multiple
blood collections using this device would be conducted
before infusion treatment, e.g., blood collection followed by

T
infusion.

3. Results

E
A total of 300 children with the age of 7 years or younger
admitted to our hospital from March to June 2020 were
selected and randomly divided into a control group
(n = 148) and an observation group (n = 152). The control

R
group consisted of 78 males and 70 females, with an average
age of 4:5 ± 2:13 years; clinical manifestations include 74 Figure 3: The outline view of the new device after assembly.
upper respiratory tract infections, 26 diarrhea, 33 pneumo-
nia, and 15 other diseases. The average age for the observa-
tion group was 4:0 ± 2:21 years, which consisted of 82 The coagulation rate of the control group was 4.3% (10/
males and 70 females, with clinical diagnosis of 73 upper 230), while that of the observation group was 5.5% (15/275),
respiratory tract infections, 28 diarrheas, 32 pneumonias, statistically not significant between the two (P > 0:05).
and 19 other diseases. There is no statistical difference In the comparison of the unqualified rate of specimen
between the two groups in terms of age, sex, and clinical dis- collection between the two groups, the unqualified rate of
ease categories (P > 0:05). blood specimens in the observation group was 1.3% (5/
A total of 750 tubes of blood samples were collected, 350 400), which was lower than 9.4% (33/350) in the control
tubes in the control group (148 patients) and 400 tubes in group, and the difference between the two groups was statis-
the observation group (152 patients). The overall hemolysis tically significant (P < 0:05).
rate in the observation group was lower than that of the con- The blood collection time in the observation group was
trol group, with statistically significant difference (P < 0:05), significantly shorter than that in the control group
The hemolysis rate generally has no normal range, but the (P < 0:05), and the incidence of needlestick injury was also
normal value of the hemolysis index is 1 : 64. If the hemolysis significantly reduced (P < 0:05), as shown in Table 2.
index test result is greater than 1 : 64, the probability of The incidence of complications and patient satisfactions
hemolysis is very high as shown in Table 1. between the two groups were also compared. The incidence
Applied Bionics and Biomechanics 3

Table 1: Comparison of blood specimens of two study groups.

EDTA tube Blood clotting tube Heparin tube Erythrocyte sedimentation Overall hemolysis rate
Group Dry tube (%)
(%) (%) (%) tube (%) (%)

D
20/120
Control 15/115 (13%) 10/50 (20%) 5/55 (9.1%) 1/10 (10%) 51/350 (14.6%)
(16.7%)
15/130
Observation 10/125 (8%) 5/65 (7.7%) 5/70 (7.1%) 0/10 (0) 35/400 (8.6%)
(11.5%)

E
X2 0.000 3.346 2.871 0.001 0.000 4.935
P value 1.000 0.067 0.090 0.971 1.000 0.026

T
needle prevents the puncture needle from air contamination
Table 2: Comparison of blood collection time and needlestick
and also reduces the chance of needlestick injury to the med-
injury rate between the two study groups.
ical staff. Finally, the male and female adhesive buckle is
Number of Operation Needle stick simple and convenient, which is used to stop blood flow in
Group the tubing during blood draw when the two adhesive pieces
blood specimens time (minutes) injury rate (%)

C
Control mate, not only avoiding damage to the soft tubing but also
350 6:2 ± 1:3 32 (9.1%) improving the efficiency of blood collection. In addition,
group
Observation
strict disinfection procedures and catheter flushing were per-
400 4:7 ± 1:1 6 (1.5%) formed to avoid contamination. More importantly, the
group
newly designed blood sampling device has a low cost of
X2 5.624 22.669

A
about half a US dollar, 2-3 fold cheaper than the price of
P value <0.05 <0.05 similar device in China, thus saving a large amount of
expenses for hospitals and testing labs if broadly used.
The overall hemolysis rate in observation group is a bit
of complications associated with the use of new blood collec- lower than that in the control group. Indeed, children are

R
tion device in the observation group was significantly lower often uncooperative for a venipuncture at the second time
than that in the control group (P < 0:05), and similarly, the due to fear of needle and thus more difficult to puncture
rate of patient satisfaction was significantly higher in the and prone to hemolysis [11]. The chance of hemolysis can
observation group (Table 3). be reduced by some methods, such as collecting blood from

T
the indwelling catheter in the anterior elbow area [12].
4. Discussion In the observation group, the percentage of unqualified
blood samples collected using the new device was reduced,
The most common method of blood collection in hospitals and the operation time was shortened more than one minute
or clinics is to use disposable blood collection needle, which relative to the control group. Insufficient blood is one of the

E
requires arterial or venous puncture separately [8]. In order reasons for unqualified blood samples due to the complexity
to reduce the number of puncture, an indwelling needle is of this operation for pediatric patients [13]. Our design sim-
commonly used in a clinic or hospital for sick children for plified the tasks of blood collection and infusion into a single
dual purposes of blood collection and infusion treatment operation that is convenient and fast so as to improve the
efficiency of first aid in health settings.

R
[9]. However, the traditional indwelling needle technique
needs connection and disconnection of the needle to allow Our data suggest that the incidence of needlestick injury
the syringe to be inserted into the sample collection tube and complications decreased among the group using the
for blood collection. This operation is repetitive and compli- new blood collection device, and the patients’ satisfaction
cated and requiring the right force from both hands to insert also improved. This innovative device has combined the
the needle into or withdraw from the tube, which may affect multiple clinical tasks of blood collection, infusion, and
the stability of the needle in the vein at the other end [9]. intravenous indwelling function into one simple operation,
This procedure is especially difficult when performed on which improve the efficiency of blood sampling and reduce
children who are often crying and moving, with minimum operation time. In the process of blood collection, it also
cooperation, thus more likely causing operational errors or reduces the risk of infection and needlestick injury.
high risk of needlestick injuries [10]. This study has several limitations. First, the sample size
Our design of safe intravenous blood collection device in the study cohort is limited, so a larger scale study for com-
has several features with advantages in clinical practical use prehensive evaluation of this device in children might be
over regular blood sampling device. First, the needle-free needed. Second, this device was not evaluated in adult
threaded adapter can reduce the number of punctures and patient groups because the study was conducted in chil-
lower the incidence of needle injury of medical staff. Second, dren’s hospitals. Lastly, the length of time for a needle
the negative pressure tube prevents the puncture needle indwelling in the vein or types of medication used in infu-
from hurting the medical staff and provides a safer and ster- sion was not included as confounding factors when identify-
ile operation area. Third, the sheath surrounding puncture ing complications among the two study groups.
4 Applied Bionics and Biomechanics

Table 3: Comparison of incidence of complications and patient satisfaction between the two groups.

Number of Tube blockage Tube detached Liquid leakage Total complications Satisfactory rate
Group
patients (%) (%) (%) (%) (%)

D
Control group 148 5 (3.3%) 9 (6.1%) 19 (12.8%) 33 (22.3%) 118 (79.7%)
Observation
152 2 (1.3%) 5 (3.3%) 5 (3.3%) 12 (7.9%) 150 (98.6%)
group
X2

E
12.2 28.3
P value <0.05 <0.05

5. Conclusions was calculated based on the number of hemolytic tubes

T
divided by the number of total tubes. The coagulation rate
In summary, this safety blood collection device can be con- (%) is the ratio of the coagulation tubes out of total tubes.
nected easily with different types of indwelling needles using To meet the clinical blood collection standard, the sample
the threaded adaptor, simple to operate and no need of being collection volume must be between 2.2 and 3.2 mL for blood
disconnected repeatedly. It overcomes the shortcoming of coagulation tube, 1.5-1.7 mL for blood sedimentation tube,

C
the traditional IV indwelling needle in China that serves a 3-5 mL for drying tube and heparin tube, and 1-3 mL for
single purpose of infusion. One needle puncture in pediatric EDTA tube. Complications include tube blockage, tube
patients is enough for multiple blood drawings and infu- detached, and liquid leakage. The rate of total complications
sions, which effectively reduce the operation time and the is equal to the sum of all complication occurrences divided
incidence of needlestick injury and also save significant cost by the number of total patients.

A
for hospitals and other health settings. Of course, this new The time spent for the blood sampling was determined
device should be applicable in adult patients for the same using a stopwatch from the beginning of skin disinfection
procedures and worthy of further investigation in the future. to blood collection and to IV infusion. The incidence of nee-
dlestick injury and related complications were recorded. The
6. Methods patient satisfaction questionnaire was designed with refer-

R
ence to Kantartjis et al.’s literature [14], comprising of four
6.1. Study Groups. All experimental studies were carried out aspects: nurse’s blood collection technology, blood collection
in accordance with Anhui Medical University clinical study time, patient’s cooperation, and patients’ knowledge about
guideline and regulations. All experimental protocols and blood sampling via education, with a total score of 100

T
study design were reviewed and approved by the Anhui points. The parents or guardian of the patient would answer
Medical University review board. Informed consent was the questionnaire if a patient was too young and unable to. A
obtained from either parent or legal guardian of children score of ≥90 was considered satisfactory, 70-89 was
in the study cohorts. considered basically satisfied, and <70 was considered dis-
A total of 300 children admitted to our hospital from satisfied. The rate of patient satisfaction ð%Þ = ðsatisfaction

E
March to June 2020 were selected and randomly divided into + basic satisfactionÞ/total number of patients × 100%.
a control group (odd number in the last digit of patients’
admission number) and an observation group (even number
in the patients’ last digit of admission number), with 148 as 6.3. Statistical Analysis. A t-test was used to compare the
numerical values between two groups, while chi square value

R
the control group and 152 as the observation group. The
clinical operation of blood collection was performed by pedi- (X 2 ) test used for percentage comparison between groups.
atric nurses with standardized training and extensive experi- The statistical calculation was performed using SPSS23.0
ence according to the clinical operation standards. The software, with P < 0:05 being considered statistically
following are the inclusion criteria: (1) those who need to significant.
receive both intravenous infusion and venous blood sam-
pling on the day of admission, (2) less than or equal to 7
years old, and (3) the guardian of the child agreeing to par- Data Availability
ticipate and sign an informed consent. The exclusion criteria
include (1) neonatal hemolysis, (2) patients with skin burns, The datasets used and/or analysed during the current study
and (3) children with hypercoagulable state. are available from the corresponding authors on reasonable
request.
6.2. Comparisons of Efficiency, Safety, and Complications
Associated with the Use of Two Different Blood Sampling
Devices. The hemolysis rate and coagulation rate of the sam- Ethical Approval
ples and percentage of unqualified samples were compared
between the two groups. Two professional inspectors inde- All experimental protocols and study design were reviewed
pendently evaluated the quality of blood collection samples and approved by Anhui Maternal and Child Health Hospital
including hemolysis and coagulation. The hemolysis rate review board.
Applied Bionics and Biomechanics 5

Consent lytical problem in the serum of newborns and adults,” EJIFCC.,


vol. 31, no. 1, pp. 6–14, 2020.
Informed consent was obtained from either the parent or [12] N. J. Heyer, J. H. Derzon, L. Winges et al., “Effectiveness of
legal guardian of children in the study cohorts.

D
practices to reduce blood sample hemolysis in EDs: a labora-
tory medicine best practices systematic review and meta-anal-
Conflicts of Interest ysis,” Clinical Biochemistry, vol. 45, no. 13-14, pp. 1012–1032,
2012.
This design was awarded a national utility model patent [13] X. Lai, P. Yang, Y. Zhang, J. Cao, and L. Zhang, “Analysis of

E
(zl201822182602. X) in China. All other authors declare no factors influencing the generation of unqualified clinical sam-
conflict of interest. ples and measures to prevent this generation,” Annals of Lab-
oratory Medicine, vol. 32, no. 3, pp. 216–219, 2012.
Acknowledgments [14] M. Kantartjis, S. E. F. Melanson, A. K. Petrides et al.,
“Increased patient satisfaction and a reduction in pre-

T
This project was funded by Hefei Science and Technology analytical errors following implementation of an electronic
Research Project (grant Heke 2017-03-69). specimen collection module in outpatient phlebotomy,”
Laboratoriums Medizin, vol. 48, no. 3, pp. 282–289, 2017.

References

C
[1] S. Tripathi and T. Gladfelter, “Peripheral intravenous catheters
in hospitalized patients: practice, dwell times, and factors
impacting the dwell times: a single center retrospective study,”
The Journal of Vascular Access, vol. 30, article

A
11297298211000874, 2022.
[2] D. Y. Wang, R. J. Yang, and H. Ma, “Needle stick injuries
among nurses in China: meta-analysis,” Journal of Health Sci-
ence and Alternative Medicine, vol. 1, no. 2, pp. 24–29, 2019.
[3] C. L. Liu, X. Y. Liu, Y. H. Zhu, and Y. X. Liu, “Influencing fac-

R
tors for needlestick injuries in student nurses,” Zhonghua Lao
Dong Wei Sheng Zhi Ye Bing Za Zhi, vol. 33, no. 7, pp. 528–
531, 2015.
[4] A. C. Harb, R. Tarabay, B. Diab, R. A. Ballout, S. Khamassi,
and E. A. Akl, “Safety engineered injection devices for intra-

T
muscular, subcutaneous and intradermal injections in
healthcare delivery settings: a systematic review and meta-
analysis,” BMC Nursing, vol. 14, no. 1, p. 71, 2015.
[5] M. Malinowski, A. Serafin, and A. Prazmowska-Wilanowska,
“DropSafe safety pen needle helps to prevent accidental nee-

E
dlesticks after injections: results of a simulated clinical study,”
Journal of Infection Prevention., vol. 22, no. 1, pp. 19–27, 2021.
[6] J. Webster, S. Osborne, C. M. Richard, and K. New, “Clinically-
indicated replacement versus routine replacement of periph-
eral venous catheters,” vol. 1, Article ID CD007798, 2019.

R
[7] C. Gillio-Meina, G. Cepinskas, E. L. Cecchini, and D. D. Fraser,
“Translational research in pediatrics II: blood collection, pro-
cessing, shipping, and storage,” Pediatrics, vol. 131, no. 4,
pp. 754–766, 2013.
[8] G. Lippi, G. L. Salvagno, M. Montagnana, G. Brocco, and
G. Cesare Guidi, “Influence of the needle bore size used for col-
lecting venous blood samples on routine clinical chemistry
testing,” Clinical Chemistry and Laboratory Medicine, vol. 44,
no. 8, pp. 1009–1014, 2006.
[9] F. D. Lesser, D. A. Lanham, and D. Davis, “Blood sampled
from existing peripheral IV cannulae yields results equivalent
to venepuncture: a systematic review,” JRSM Open, vol. 11,
no. 5, article 205427041989481, 2020.
[10] M. Düzgöl, A. K. Aksay, E. Durgun et al., “Risk groups for nee-
dlestick injury among healthcare workers in children‘s hospi-
tal: a cross-sectional study,” Journal of Pediatric Infection/
Cocuk Enfeksiyon Dergisi, vol. 14, no. 4, pp. e212–e217, 2020.
[11] J. Tóth, A. V. Oláh, T. Petercsák, T. Kovács, and
J. Kappelmayer, “Detection of haemolysis, a frequent preana-

You might also like