You are on page 1of 7

ACCESING Mini-Link 6366

From indoor units

HADI BALHARITH
LAN Connections

TN 5
TN 5

TR3 / NPU1D

Port 10

Port 4

LCT IP NE IP Mask GW Local VLAN


10.70.148.30 189-43_ML6366_ZDA044 10.70.148.18 255.255.255.240 10.70.148.17 101
10.70.148.30 ZDA044_ML-6366 10.70.148.19 255.255.255.240 10.70.148.17 101

2019-05-19 | | Page 2
Ml-6366 vlan configuration
› In ML-6366 , Configure DCN VLAN and add ports ( LAN 1/0/3 , LAN-DCN
1/0/0 , SFPo 1/0.5 ) & add (LAN-DCN 1/0/0) to untagged members .

2019-05-19 | | Page 3
R6471 configuration
› Login to R6471, and run below commands
config config
port ethernet 1/10 port ethernet 1/4
description "WAN" description "ML6366_OAM"
auto-negotiate auto-negotiate
no shutdown no shutdown
encapsulation dot1q encapsulation dot1q
service-instance 101 service-instance 101
match match
dot1q 101 untagged
commit vlan-rewrite
end ingress seq 1 push outer dot1q 101
! egress seq 1 pop outer
commit
end
!
config
bridge ML6366_OAM
port 1/10 service-instance 101
port 1/4 service-instance 101
commit
end
!
save configuration
y
2019-05-19 | | Page 4
Pc setup

› Setup your PC with LCT IP

2019-05-19 | | Page 5
Login from indoor units
› Open Google Chrome or Mini-Link craft
› Login to the node using the DCN IP

2019-05-19 | | Page 6

You might also like