You are on page 1of 2

INT69 V®, INT69 VS®,

INT69 TM®
for heavy start or high switching frequency
Application:
The INT69 VS, INT69 V and developed for motors with high
INT69 TM motor protection starting load or drives with high
modules have been especially switching frequency.

INT69 V Motor Protection


Module:
The INT69 V switching points shut-down is activated . After
and hysteresis are similar to the motor windings cool down,
those of the INT69 motor the lock-out function can be
protection module. In addition it reset by interrupting the supply
is equipped with an electronic voltage, removing the jumper
INT69 V, INT69 VS lock-out function. By inserting B1-B2 or by depressing the
a jumper between terminal B1 reset button (option).
and B2, lock-out after thermal

INT69 VS Motor Protection


Module:
Standard PTC control modules switching hysteresis spread, so
are reset after terminal trip that a reset temperature dif-
when the motor windings have ference of approx. 10K is achie-
cooled down by approx. 1...3K. ved and secondly lock-out can
For some applications, how- be selected by inserting a
ever, e.g. for motors with high jumper (B1-B2). After cooling
switching frequency (cranes, down, the motor can be restar-
lifts, winches, etc.) this tem- ted if the lock-out function is
perature difference may be too reset by interrupting the supply
small. The INT69 VS motor voltage, removing the jumper
protection module has been B1-B2 or by depressing the re-
INT69 TM developed for these special set button (option).
drive applications. Firstly the
relay

Hysteresis
14 11 12 1...3K Note :
on off
Due to the displacement of the perature) of the PTC sensors
trip-point to approx. 12.5k must, therefore be 10K below

Product Group A
14 11 12 RPTC the trip temperature is approx. the required trip temperature.
10K above the nominal re-
2,5k 4,5k sponse temperature of the PTC. Example:
INT69 V When the INT69 VS is used, the NAT=150°C (insulation class F)
NAT (nominal response tem- NAT=150°C minus 10K=140°C
relay

14 11 12 Hysteresis
approx.10K
on off
INT69 TM Motor Protection
Module:
RPTC The INT69 TM motor protection down period. As with to the
14 11 12
2,4k 12,5k module has also been desig- standard control modules, the
Edition: 690.00051.0

ned for motors with high starting trip point is 4.5k and thus cor-
INT69 VS
load and/or high switching fre- responds to the nominal re-
1...3K + 5min quency. The extended cool- sponse temperature of the PTC
relay 5min 1...3K down period of the INT69 VS thermistors. As soon as the
protection module is achieved PTC resistance deeps to 2.5k
Hysteresis increasing the switching hyster- the internal timer of the INT69 TM
14 11 12
1...3K esis, whereas the INT69 TM is is activated and after approx.
on off equipped with an additional time 5min the output relay pulls in
function for extended cool- again.
14 11 12 RPTC

2,5k 4,5k
INT69 TM

CMP Coproration • P.O. Box 15199 • Oklahoma City, OK 73155 • Phone: (405) 672-4544 • Fax: (405) 672-4547 • USA Toll Free: (800) 654-4786 • Mexico Toll Free: (800) 777-4786
www.cmpcorp.com • email: kriwan@cmpcorp.com
INT69 V®, INT69 VS®, INT69 TM®
for heavy start or high switching frequency
Technical data general
Supply voltage AC 50Hz 230V ±10% 3VA
Ambient temperature range -20...+60°C
Relay AC 250V, max. 5A, 300VA ind.
L N 1 2 12 14 11 B1 B2 Mechanical service life approx. 1 mio. switching cycles
Protection class acc. to with terminal cover: IP20
*) EN 60529 without terminal cover: IP00
mains Housing PA6 GF30
* ) with jumper: locked trip-out Mounting on 35mm standard rail acc. to
without jumper: unlocked trip-out EN 50022 or base mounted
Connection Diagram
INT69 VS, INT69 V
Technical data INT69 V
Measuring circuit
40 - type PTC, acc. to DIN 44081/082
6
4,5 - number of sensors 1...9 in series
- R25 total < 1,8k
Switching hysteresis 1...3K
Weight approx. 200g
72
87

Technical data INT69 VS


Measuring circuit
2,5

3,5 58 - type PTC, acc. to DIN 44081/082


- number of sensors 1...9 in series
Dimensions in mm - R25 total < 1,8k
INT69 VS, INT69 V
Switching hysteresis approx. 10K
Weight approx. 200g

Technical data INT69 TM


Measuring circuit
- type PTC, acc. to DIN 44081/082
- number of sensors 1...9 in series
L N 1 2 12 14 11
- R25 total < 1,8k
Switching hysteresis 1...3K, with additional time
factor of 5min 15% for
cooling down
mains
Weight approx. 190g
Connection Diagram
INT69 TM
Ordering information
INT69 VS, standard version 52 A 125
INT69 VS, with mains and fault
4,5
control 52 A 125 S25
2,5

INT69 VS, with mains and fault


control and reset
button 52 A 125 S22
INT69 V, standard version 52 A 127
68
53

INT69 V, with mains and fault


control 52 A 127 S21
INT69 V, with reset button 52 A 127 S24
3,5 10 INT69 V, with mains and fault
33 80 control and reset button 52 A 127 S22
INT69 TM with terminal cover 52 A 240 S10
Dimensions in mm
INT69 TM Subject to technical modification

KRIWAN Industrie-Elektronik GmbH • Allmand 11 • D-74670 Forchtenberg • phone ++49-7947-822-0 • fax ++49-7947-1288 • e-mail: info@kriwan.com • home: www.kriwan.com