REPUBLIC OF THE PHILIPPINES DEPARTMENT

OF PUBLIC WORKS AND HIGHWAYS


A B C C' D E OFFICE OF THE BUILDING OFFICIAL
CEBU CITY
16000
2000
13000 3000
ISSUANCE RECOMMENDED
CONFIRM BATH TUB
DIMENSION FIRST 2700 3600 4700
7700 600
8300 FIREWALL
SECTION HEAD DATE
3 3
ISSUED BY:

2000
1 2 3 4 5 6 7 8 9 10

3150 SERVICE/ LAUNDRY AREA


BEDROOM 1 UP
MASTER T & B
2'
COMMON T & B
KITCHEN BUILDING OFFICIAL DATE

2538
2
8700 FIREWALL

8700 FIREWALL
7075

7200
HALLWAY DINING
ELECTRICALNOTES

8700
PARKING
AREA 1' ALL ELECTRICAL WORKS AND INSTALLATION SHALL COMPLY WITH THE
10000

10000

10000
PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL
3925

CODE WITH THE RULES AND REGULATIONS OF THE NATIONAL AND


MASTER BEDROOM BEDROOM 2 BEDROOM 3 LOCALAUTHORITIESCONCERNED.

2663
LIVING
SERVICE VOLTAGE TO THE BUILDING SHALL BE 110/220V, 60 Hz, SINGLE
PHASE/THREE PHASE

1 1 THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION


OF THE CONCRETE TERMINAL POLE FOR THE CONNECTION TO THE
1625

1500
POWERANDTELEPHONESERVICE.
2925

2800
ALL INSTALLATIONS SHALL BE CONCELLED FROM VIEW, WIRING SHALL
BE INCASE IN POLYVINYL CHLORIDE (PVC) PIPE SCHEDULE 40 EXCEPT
1300

POWER SUPPLY TELEPHONE SERVICE WHICH SHALL BE RIGID STEEL


CONDUIT (RSC) OTHERWISE NOTED

MINIMUM WIRE AND CONDUIT SIZE SHALL BE 3.5mm sq. THNN AND
15mm. DIA. PVC PIPE TRADE SIZE, RESPECTIVELY, UNLESS OTHERWISE
N O T E D .
3200 2250 2250 5300
13000 3000 PULL BOXES OF APPROPRIATE SIZE SHALL BE PROVIDED, EVEN IF NOT
16000 INDICATED IN DRAWINGS TO ACCOMODATE THE NUMBER OF SPLICES
O F W I R E S .

A A' B' C D E A L L F L OUR E S C E N T L AMP S S HA L L B E P RO V I D E D W I T H


POLYESTER-FILLED PRE-HEAT, THERMALLY PROTECTED, HIGH POWER
B A L L A S T .

ALL MATERIALS TO BE USED SHALL BE NEW AND APPROVED TYPE


APPROPR I ATE FOR BOTH LOCAT I ON AND I NTENDED USE .

LIGHT CONTROL SWITCHES SHALL BE RATED 10A, 300W AND SHALL


NOTCARRYLOADGREATERTHAN50A.

DUPLEX RECEPTACLES SHALL RATED 10A, 250W, ROUNDED SLOTS FOR


220V AND PARALLEL SLOTS FOR 110V, AND SPECIAL OUTLETS SHALL
BERATED15AOR250VASREQUIRED.

FOR EACH SPARE CIRCUIT IN PANELBOARD, PROVIDE EMPTY ¾"Ø RISER


TERMINATING IN A 2 1/8" DEEP BY 4" OCTAGONAL BOX ABOVE CEILING.
A B C C' D E
ELECTRICAL INSTALLATIONS SHALL BE UNDER THE DIRECT
SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER.
16000
2000
CONFIRM BATH TUB 13000 3000 OUTLETBOXESSHALLBEASFOLLOWS:
DIMENSION FIRST 2700 3600 4700
(HT.= 0.30 M.) 1 1/8" DEEP, 4" OCTAGONAL BOX 3 OR 4 WAY ENTRIES.
7700 600 LIGHT OUTLETS..... 1 ½" DEEP, 4" OCTAGONAL BOX 1 OR 2 WAY ENTRIES
8300 FIREWALL (HT.= 0.30M) 1 ½" DEEP, 4" SQUARE BOX WITH 1 GANG RAISED
3 3 PLASTEDCOVERFOR3OR4RACEWAYENTRIES,
RECEPTACLE & TEL. OUTLETS..... 2 1/8" DEEP, 2"x 4" UTILITY BOX 1 OR 2
RACEWAY ENTRIES PUSH BUTTON OUTLET..... 1 1/8" DEEP, 2"x 4"
2000

UTILITY BOX SPECIAL PURPOSE OUTLETS..... 1 ½" DEEP, 4" SQUARE


BOX1GANGRAISEDPLASTICCOVER.
1 2 3 4 5 6 7 8 9 10
3150

SERVICE/ LAUNDRY AREA UP


BEDROOM 1
MASTER T & B
2' NO REVISION IN THE DESIGN SHALL BE DONE WITHOUT APPROVAL
SHALL CAUSE RESPONSIBILITY OF THE DESIGNER AND THE OWNER.
COMMON T & B
ANY SUCH REVISION DONE WITHOUT APPROVAL SHALL CAUSE
KITCHEN RESPONSIBILITY OF THE DESIGNER TO CEASE AS A WHOLE.
2538

2
8700 FIREWALL

8700 FIREWALL
7075

7200

DINING
HALLWAY
8700

PARKING
AREA 1'
10000

10000

10000
3925

MASTER BEDROOM BEDROOM 2 BEDROOM 3


2663

LIVING

1 1
1625

1500
2925

2800
1300

3200 2250 2250 5300


13000 3000
16000

A A' B' C D E
VICINITY MAP

SUBMITTED BY: SEAL/LOGO PLATE NO. 1 SUBMITTED TO: SHEET CONTENT SCALE GRADE: SHEET NO.
GROUND FLOOR LIGHTNG LAYOUT 1:200 MM

PROPOSED ONE STOREY RESIDENTIAL BUILDING GROUND FLOOR POWER LAYOUT 1:100

KATE ANGELIE B. GAHUMAN


ELECTRICAL LAYOUT AR. JEREMY IAN S. MACIAS SINGLE LINE DIAGRAM & VICINITY MAP
SCHEDULE OF LOAD
GROUND FAULT CURRENT
NTS

E1
COURSE & YR: BSARCH-3 SECTION: R4 AR363- BUILDING UTILITIES 2 GROUND FLOOR POWER LAYOUT