C L I N I C A L R E S U LT S
LINEAR CONTRACTION OBSERVED AT 6-MONTH FOLLOW-UP WAS MUCH MORE
SIGNIFICANT THAN REPORTED WITH ANY OTHER TECHNOLOGY AND VARIED FROM
DR. P. DUNCAN
12.7% UP TO 47%, DEPENDING ON PATIENT AND TREATMENT VARIABLES.
Christopher T. Chia, M.D., Ryan M. Neinstein, M.D. and Spero J. Theodorou, M.D.
Plastic and Reconstructive Surgery, Evidence-Based Medicine: Liposuction
THE MEAN SKIN SURFACE AREA REDUCTION WAS 25.8% IN REGIONS TREATED WITH
RADIOFREQUENCY PLUS SAL AT 6 WEEKS AND 36.4% AT 1 YEAR.
DR. C. MIZGAL A
D. Duncan, M.D., Aesthetic Surgery Journal, Nonexcisional Tissue Tightening: Creating Skin
Surface Area Reduction During Abdominal Liposuction by Adding Radiofrequency Heating
DR. P. ROVAT TI
DR. P. ROVAT TI
J O I N T H E R E VO LU T I O N .
The list below is a selection of industry leaders using the truly innovative InMode technology
ABDOMINAL , ARM ,
B R E A S T, K N E E S ,
THIGHS AND MORE
Pier Paolo Rovatti, MD Nicola Willis, MD Bryan Forley, MD Nicholas Nikolov, MD
Sarit Cohen, MD Christopher Chia, MD Dennis Hurwitz, MD Jason Pozner, MD
Vicente Alonso, MD John Q. Cook, MD Kenneth Kim, MD Spero Theodorou, MD
Salvatore Pagano, MD Frederic Corbin, MD George Kouris, MD Glen Vallecillos, MD
Dr Ernst Magnus Noah, MD Jason Diamond, MD Gilbert Lee, MD Daniel Jach, MD
DR. S.MULHOLL AND
Guillermo Blugerman, MD Diane Duncan, MD Thomas Loeb, MD David Jack, MD M I N I M A L LY I N VA S I V E R A D I O - F R E Q U E N C Y
A S S I S T E D L I P O LY S I S (R FA L )
External Temperature: Operator adjustable up to 43°C If you have patients that want exceptional contouring
Output Frequency: 1 MHz and lipolysis results without the excision, scars,
BodyTite controls heating to ensure or downtime, then the new BodyTite system is a great
With FaceTite, where treatment is
Uniform thermal field provides an even that large volume contraction is investment for your practice.
more superficial, hot spots
distribution of heat consistent, avoiding overtreated or
are avoided
undertreated areas A key concern with the use of today’s fat extraction
R F M I N I M A L LY I N VA S I V E technology is the compromised skin remaining
in the treatment area. BodyTite’s unprecedented
When treating different areas of three-dimensional contraction of the dermis,
Temperature feedback measures the body, the operator can always subdermal connective tissue matrix and deep fat
NeckTite is a minimally invasive handpiece Specifications Bi-polar radio frequency provides
at 1000x/sec to provide real provide real time temperature addresses those concerns.
for the remodeling and contouring of the greater safety and control compared to
time results, even in superficial monitoring, even in deep fat areas
neck and small body areas. The handpiece unipolar technologies
comprises an internal electrode located at Cannula Length: 12 cm treatment areas where laser temperature readers Previously, patients only had the following options:
the proximal end of a silicon-coated cannula cannot reach multiple non-invasive treatment options with limited
Cannula Diameter: 2.4 mm
which is introduced into the fat layer, while skin contraction results, a surgical tummy tuck
the external electrode lies over the skin has Depth of Treatment: Face - 3-25mm \ Body - 5-50mm Allows for focal treatment of even with downtime, or a brachioplasty leaving large
sensors for contact, impedance, and surface excision scars.
the smallest of areas such as under
temperature. RF is travelling between the two External Temperature: Operator adjustable up to 43°C 100% energy concentration in Allows focal treatment of all body
electrodes with a simultaneous aspiration, the eyes, above the eyes, and areas
the treatment zone areas with large volume Patients who wanted less invasive procedures were
resulting in gentle fat removal in addition to Output Frequency: 1 MHz+ where operators want to avoid other
left without a solution. With the BodyTite system, you
contouring and tightening. facial nerves
can provide minimally invasive treatment solutions and
offer your patients powerful aesthetic results previously
only achievable by surgical means.
Physician pre-sets and controls the
Superficial contouring, up to Treats deep fat, up to 50 mm
temperatures of heat gradient enables
25 mm (1 inch) (2 inches)
R F M I N I M A L LY I N VA S I V E optimal treatment results
B O DY tite
BodyTite provides superior internal
and external lipolysis, delivering Specifications
body results previously only achieved
through more extensive excisional
surgical procedures. Powered by RFAL Cannula Length:
25cm /17 cm
(Radio-Frequency Assisted Lipolysis), 1 Sensor
2 Sensors 17 cm
BodyTite provides unprecedented
three-dimensional contraction of the Cannula Diameter:
dermis, subdermal connective tissue
matrix and deep fat.
1 Sensor
2 Sensors
5 mm/ 3.9 mm
2.2 mm OPTIONAL UPGRADES
It works by delivering rapid and Depth of Treatment: Up to 50 mm
uniform bi-polar heating of the entire
tite
soft tissue matrix. Built-in safeguards Internal Temperature: Operator adjustable between 50°C - 70°C
including real time measurements External Temperature: Operator adjustable up to 43°C
B O DY