Professional Documents
Culture Documents
Teldat dm1002 Regesta Smart Pro Series Installation
Teldat dm1002 Regesta Smart Pro Series Installation
Manual
Installation Manual
Legal Notice
Warranty
Teldat S.A. offers no warranty whatsoever for information contained in this manual.
Teldat S.A. is not liable for any direct, indirect, collateral, consequential or any other damage connected to the deliv-
ery, supply or use of this manual.
Table of Contents
2.4 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.1.3 Connecting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.1.4 Disconnecting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Chapter 5 Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
5.5 CE marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5.8 REACH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A.1 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
This manual will help you understand your new device in greater depth.
http://www.teldat.com
C * 1
( 0D A =4;271E2446
+ ) C * $
0+- 1 0D A =4;271E2446
9 ?
8 &<
- $ ? #$ ! 8 &<
+ 8 <
F +
Web: http://www.teldat.com
Email: support@teldat.com
The Regesta Smart PRO router family has been especially designed to operate in hostile and extreme environments.
Thanks to their ruggedized mechanics and special characteristics, which allow them to bear extreme temperatures,
these routers are particularly suited for: industrial environments, industrial telecontrol, distribution installations for
electricity, gas, water, etc.
The router guarantees optimal execution and maximum security of communications between multiple IP services. In
addition, the simultaneous use of 2G/3G/LTE interfaces and WAN Ethernet links provides maximum communications
reliability, which is ensured thanks to the full support of the management, supervision and backup functionalities.
The device incorporates a protective casing that prevents the connectors from being touched while the device is
powered.
Code Description
RWRTHR2ZAC Regesta Smart PRO 1 LAN Gigabit Ethernet port, 1 WAN Combo Gigabit Ethernet port, 1
RS232, AC powered (110 - 240 VAC).
RWRTHR2ZDC Regesta Smart PRO 1 LAN Gigabit Ethernet port, 1 WAN Combo Gigabit Ethernet port, 1
RS232, DC powered (12 - 72 VDC).
RWRTHR2ZMR Regesta Smart PRO 1 LAN Gigabit Ethernet port, 1 WAN Combo Gigabit Ethernet port, 1
RS232, MultiRange power input (48 - 72 VDC, 110 - 240 VAC).
RWRTHR6ZAC Regesta Smart PRO 1 LAN Gigabit Ethernet port, 1 WAN Combo Gigabit Ethernet port,
4xPort Gigabit Ethernet Switch, 1 RS232, AC powered (110 - 240 VAC).
RWRTHR6ZDC Regesta Smart PRO 1 LAN Gigabit Ethernet port, 1 WAN Combo Gigabit Ethernet port,
4xPort Gigabit Ethernet Switch, 1 RS232, DC powered (12 - 72 VDC).
RWRTHR6ZMR Regesta Smart PRO 1 LAN Gigabit Ethernet port, 1 WAN Combo Gigabit Ethernet port,
4xPort Gigabit Ethernet Switch, 1 RS232, MultiRange power input (48 - 72 VDC, 110 - 240
VAC).
RWRTHR2LAC Regesta Smart PRO 1 LAN Gigabit Ethernet port, 1 WAN Combo Gigabit Ethernet port, 1
RS232, 1xWWAN (Bands: LTE 1, 3, 5, 7, 8, 20, 38, 40, 41 - WCDMA 1, 5, 8), AC powered
(110 - 240 VAC).
RWRTHR2LDC Regesta Smart PRO 1 LAN Gigabit Ethernet port, 1 WAN Combo Gigabit Ethernet port, 1
RS232, 1xWWAN (Bands: LTE 1, 3, 5, 7, 8, 20, 38, 40, 41 - WCDMA 1, 5, 8), DC powered
(12 - 72 VDC).
RWRTHR2LMR Regesta Smart PRO 1 LAN Gigabit Ethernet port, 1 WAN Combo Gigabit Ethernet port, 1
RS232, 1xWWAN (Bands: LTE 1, 3, 5, 7, 8, 20, 38, 40, 41 - WCDMA 1, 5, 8), MultiRange
power input (48 - 72 VDC, 110 - 240 VAC).
RWRTHR6LAC Regesta Smart PRO 1 LAN Gigabit Ethernet port, 1 WAN Combo Gigabit Ethernet port,
4xPort Gigabit Ethernet Switch, 1 RS232, 1xWWAN (Bands: LTE 1, 3, 5, 7, 8, 20, 38, 40, 41
- WCDMA 1, 5, 8), AC powered (110 - 240 VAC).
RWRTHR6LDC Regesta Smart PRO 1 LAN Gigabit Ethernet port, 1 WAN Combo Gigabit Ethernet port,
4xPort Gigabit Ethernet Switch, 1 RS232, 1xWWAN (Bands: LTE 1, 3, 5, 7, 8, 20, 38, 40, 41
- WCDMA 1, 5, 8), DC powered (12 - 72 VDC).
RWRTHR6LMR Regesta Smart PRO 1 LAN Gigabit Ethernet port, 1 WAN Combo Gigabit Ethernet port,
4xPort Gigabit Ethernet Switch, 1 RS232, 1xWWAN (Bands: LTE 1, 3, 5, 7, 8, 20, 38, 40, 41
- WCDMA 1, 5, 8), MultiRange power input (48 - 72 VDC, 110 - 240 VAC).
• 4xRJ45 connectors will support IEEE802.3 Ethernet over copper wiring standards of 10Base-T, 100Base-TX,
and 1000Base-T.
• Serial Ports.
• 1xRJ45 connector RS-232 port (DCE).
• 2xRJ45 connectors for RS-232 port (DCE) and/or RS-485 (2/4 wires). An additional accessory is required for this
function.
• WWAN: Depending on the model. ("L" models)
• 1xLTE Category 4 WWAN module with two SMA connectors.
• 2 Internal SIM trays with 2FF form factor.
• External Reset/Recovery push button
2.4 Components
While the device is in startup mode, LED L lights up in green. Once the device has started up, the LEDs indicate the
following:
LEDs
Amber SIM2 operating SIM. This is processing traffic through the car-
Note: Some LEDs may behave differently depending on how the device is configured.
The following figure shows the panel, which includes all Regesta Smart PRO router connectors.
Item Description
A RST. Reset button. For further information on how the reset button works, please see RST
button on page 28.
B CONF. RJ-45 connector providing access to the device's local console for configuration and
monitoring purposes. (This connector can also be used as an RS-232 asynchronous DCE
serial port.)
For more information about the WAN interface with SFP connector, refer to:
For more information about the WAN interface with Base-T connector, refer to:
For more information about the power connection options, refer to:
The type of configuration of each port depends on the hardware configuration of the device
(model).
For more information on the connector for serial ports, 2-4 wire RS-485/RS-422 and DCE
RS-232, refer to:
RS232 option:
RS485 option
I RF/WWAN antenna connectors for the Cellular interface, based on the model.
Refer to Installing the SIM card on page 26 for more information about SIM installation for
the Cellular interface.
Item Description
A Slots for the accessories to attach the device to a DIN rail mount. For further in-
formation on this accessory, please see section Wall mounting on page 17.
B Platform where the label containing product information is placed. This label con-
tains information on the device model, MAC, serial number, etc.
Note
Before connecting the router, please, identify your model and read the following instructions carefully!
Warning
This equipment must be installed in restricted access locations. Only trained and qualified personnel
are allowed to install, replace or service this equipment as instructed in this installation guide.
• The device should not be placed amongst papers, magazines or other elements that could hinder natural air circu-
lation.
• Knocks and/or strong vibrations should be avoided during transport, operation and storage.
Warning
The electric current in power cables, telephone lines and communication cables is dangerous. To pre-
vent electric shocks, before installing, handling or opening the equipment covers, connect and discon-
nect the cables following the steps set forth in Connecting on page 21 andDisconnecting on page 21.
Warning
This unit might have more than one power supply connection. All connections must be removed to de-
energize the unit.
To remove the case that protects the connectors, follow these steps:
Locate the fastening mechanism in the middle of the front panel and turn it to the vertical position by rotating it 90º to
the left or right.
The following figures show you how to remove the protective case from the device.
Lock the case into position by rotating the fastening mechanism back to a horizontal position and pushing down. You
should hear a little click.
Warning
The connector protective casing needs to be installed before the device is powered on.
The kit contains 2 screws for attaching the DIN rail to the underside of the device. The DIN rail can be secured in two
different positions via the holes on the underside of the device:
The following image shows where the fastening holes are located:
Note
Please read the following instructions carefully before connecting the router!
Note
Please check that the device's power input is compatible with your power supply.
The power connector on this router is a 2-wire terminal block 5.08 mm pitch.
The connector has 2 terminals for both AC (AC version or AC-powered MR version) and DC powering (DC version or
DC-powered MR version).
PIN Signal
- - V DC
+ + V DC
PIN Signal
Neutral
N
L Phase
Warning
The power cable is not supplied with the router. Any cable with a gauge greater than, or equal to, a
0.75 mm2 section (AWG18 conductor) and approved by IEC 60227 is acceptable.
Warning
All AC powered interconnected communication devices should be plugged to THE SAME GROUNDED
POWER OUTLET, which should, at the same time, be of good quality (lower than 10 ohms). In the
case of DC models, the power distribution system must be entirely located in a single building, and
earthed at a single point. This is not necessary if the cabling associated with the DC power distribution
system is shorter than 4 m, or is fully installed within a metal pipe.
Connecting all data devices to the same power source is strongly recommended, regardless of whether
the workplace has an uninterrupted power supply (UPS), a regulated supply, or is independent of other
power supplies (such as lighting, etc.). This will help prevent malfunctions and premature aging of the
drivers and other components.
4.1.3 Connecting
• Make sure the power supply is NOT connected to either the electricity supply
or the router.
• Connect all data cables.
• Connect the power supply cable to the device.
• Install the protection case for connectors.
• Connect the power supply cable to the electricity supply.
4.1.4 Disconnecting
• Disconnect the power supply from the electricity supply.
• Remove the protective case.
• Disconnect the power supply from the router.
• Disconnect the data cables.
Please pay careful attention to the labeling to avoid mistaking this port for other types of ports:
Please pay careful attention to the labeling to avoid mistaking this port for other types of ports:
• Class 1
• IEC/EN60825-1:2007 2nd Edition or a later one, European standard
• FCC 21 CFR Chapter 1, Subchapter J (in accordance with FDA and CDRH re-
quirements)
• Application of CE marking in accordance with the 2014/30/EU EMC Directive
and the 2014/35/EU Low Voltage Directive
• UL and/or CSA registered component for North America
• 47 CFR Part 15, Class A
Warning
Laser Radiation. Do not use optical instruments directly or without proper protection. CLASS 1 LASER
PRODUCT.
The SFP modules to be installed in the card socket should be class 1 devices that comply with the IEC/
EN 60825-1:2007 standard.
Please pay careful attention to the labeling to avoid mistaking this switch for other types of ports:
The RF1 connector is connected to the module’s MAIN connector, while the RF2 connector is linked to the AUX con-
nector.
Using these antennas in the Regesta Smart PRO router improves the quality of the signal received and transmitted
by the WWAN module.
Some cellular technologies use the antenna diversity technique to improve the quality of the signal received
(HSUPA, LTE, etc.). For this reason, the Regesta Smart PRO incorporates two WWAN/RF connectors. Regardless
of the configuration, the antenna on RF1 must be always installed (whilst the RF2 one is optional).
If the RF1 and RF2 antennas are connected via extension cables rather than being screwed into the router, the min-
imum distance between them must be 7 cm. The maximum recommended distance between the two antennas is 25
cm. In order to comply with EMC regulations, the extension cable must not be longer than 3 m.
To achieve optimum performance, any radio frequency accessories installed (antennas and cables) should be those
recommended by Teldat.
Teldat offers a series of accessories (90º mount antennas, antennas for outdoor installation, antennas for ceiling in-
stallation, extension cables, etc.) that allow you to install the devices in different locations.
Antenna orientation and its location with respect to other wireless devices and radiation devices (such as communic-
ation devices, personal computers, etc.) can significantly influence device performance.
Antennas transmit and receive radio signals. Performance is also affected by environmental factors (such as dis-
tance between the device and the base station), physical obstacles and other interferences caused by radio frequen-
cies (RF).
• Whenever possible, place the antenna where there are no physical obstacles. Obstacles between the antenna and
the base station degrade the wireless signal. Place the antenna above ground level facing the nearest base sta-
tion.
• Density of materials also affects antennas. Place them away from any type of wall, metal screens, mirrors, etc.
• Do not place the antenna near columns, which may throw shadows and reduce the coverage area.
• Keep the antenna away from metal pipes such as those used for heating, air-conditioning, etc.
• Please bear in mind that other wireless devices such as telephones, microwaves, etc., can temporarily interfere
with the quality of the radio signal.
• We do not recommend installing antennas near, or between, racks containing communication devices, computers,
etc. Use an extension cable and place the device outside.
• Do not touch or move the antenna while the device is transmitting or receiving.
• Do not touch any equipment containing devices that radiate, where the antenna is very close to or touching any ex-
posed part of the body (particularly the face and eyes), when it is transmitting.
• Do not install the device in areas where the atmosphere is potentially explosive.
• Wireless devices can cause interference with other devices. Do not use the device in areas where medical equip-
ment is installed.
• To ensure the RED 2014/53/EU directive is complied with, the device must be at least 20 cm away from a person’s
body when operating.
The console port can be converted into an RS-232 asynchronous DCE serial port. The latter has the following char-
acteristics:
(1) DCE port.
(2) RS-232 norm.
(3) Maximum speed of 115200 bps.
(4) Only the following signals are available: RxD, TxD and GND. See Configur-
ation connector on page 36 for more information about pin assignment.
(5) RJ45 connector.
The Asynchronous Serial Ports feature is optional and requires some additional hardware. Some models are
equipped with 2 extra serial ports. The Regesta Smart PRO includes two RJ-45 connectors to provide these serial
ports, although they might not work on some models. Check the label to find out if the device offers serial ports, as
well as to obtain information on their type.
These serial ports can be RS-232 and/or RS-485/RS-422. They have the following characteristics:
The Regesta Smart PRO has two SIM trays. Both trays are located under the device's protective case and are
labeled SIM1 and SIM2.
In installations where only one SIM card is required, we recommend installing it in the SIM1 tray.
Warning
Never install the SIM cards when the device is switched on.
Always disconnect the device from the main power supply before installing the SIM cards.
Always disconnect the device before removing the connector protective casing to access the trays.
When inserting the SIM cards, please protect yourself against electrostatic discharges (ESD).
To access the SIM trays, you need to remove the protective case. Please refer to Removing/Installing the connector
protector on page 14 to learn how to remove the casing.
The Regesta Smart PRO incorporates 2 SIM cards, which allow you to execute some special configurations. For ex-
ample, when installing two SIM cards one can be used as backup. To carry out this type of configuration, you must
assign a tray to each SIM (since they require different configuration parameters).
The SIM trays are identified as SIM1 and SIM2 (i.e., socket 1 and socket 2).
• To trigger a reboot.
• To restart the device with the default configuration. The default configuration has IP 192.168.1.1 assigned to all
switch ports.
The external button is physically protected to stop it from being accidentally pushed. You need a sharp-pointed ob-
ject to activate it.
At 10W power consumption, the device stays powered for 6 seconds, allowing the alarm to be sent through any act-
ive interface.
This alarm (GW.075) can be sent as an Event, SNMP-TRAP or Syslog using the Event Logging System (ELS).
(1) Configure the ELS to enable the GW.075 event as Trace, Syslog event or snmp-trap.
For further information on ELS, please see manual: “Teldat Dm704-I Configuration and Monitoring”.
(2) Configure the SNMP protocol, host and sending parameters if required.
For further information on SNMP configuration, please see manual: “Teldat Dm712-I SNMP Agent”.
(3) Configure and enable the Syslog feature and server if required.
For further information about the Syslog Feature, please see manual: “Teldat Dm753-I Syslog Client”.
4.6 Troubleshooting
The following table can help you solve problems when installing the device. If you cannot solve the problem, contact
your dealer for more information.
Symptom Solution
None of the LEDs light up on Check the power supply to the router (power source, main power outlet).
the router.
The local console does not re-
spond. Check the console cable is the right one and that it is connected to the device and
the asynchronous terminal.
You have forgotten the access Ignore the configuration through the RST button (as explained in the relevant sec-
password for the router. tion).
Date and time in the device are Parameters configured through the time set command will be lost when the device
lost when restarted. restarts. Use the NTP protocol to keep the date and time configuration.
The LAN, WAN, SFP or SW Check the Ethernet cable, or Fiber, and the connection to the network (you may
LEDs do not light up in green. need a crossover cable).
For further information, please see manual: “Teldat Dm709-I LAN Interfaces”.
The S LED is red. Check the SIM card has been inserted correctly,
or
or
or
Get your technical service to check the device is in the optimum position for the
service.
For further information, please see manual: “Teldat Dm781-I Cellular Interface ”.
There are various ways to update one of our routers. For further information, please see manual Dm 748-I Software
Updating.
The software required to update one of our routers is supplied in a format known as distribution. This consists of a
single file, which contains all the files needed to update your device as well as in-depth information on their content.
The Regesta Smart PRO incorporates independent modules for the Wireless WAN interface. You can pick modules
from different manufacturers or choose several modules from the same provider, depending on the technology used.
Generally, the firmware is independent from the software. There is an UPGRADE file for each Wireless WAN mod-
ule. Please ask you distributor for the correct UPGRADE file (based on the module in your device). The Cellular in-
terface manual (Dm781-I) explains how to upgrade the module.
The Regesta Smart PRO has a RJ.45 female connector on the front panel known as CONF., which provides access
to the device's local console. To configure this, connect the CONF. port to an asynchronous terminal (or to a PC with
terminal emulation).
To connect to the configuration port, use the RJ45 cable (provided with the router) and the female RJ45-female DB9
adapter (also provided with the router). If the terminal has DB25 connectors, an additional adapter will be needed.
The Regesta Smart PRO includes a default configuration that activates if you haven’t preconfigured anything.
The router’s default configuration establishes the following IP address and access mask:
• IP address: 192.168.1.1
• IP mask: 255.255.255.0
Note
Some devices leave the factory with customized settings. This personalization can mean that the de-
fault configuration is different from the one shown above.
This initial configuration allows you to access the device's configuration console through the Telnet IP protocol. To do
this, carry out the following steps:
Chapter 5 Compliance
Country Spain
Postal Address
Isaac Newton, 10
Spanish (ES) Español Por la presente, Teldat S.A. declara que el tipo de equipo de telecomunicaciones
Regesta Smart PRO es conforme con:
The EC declaration of conformity and additional product documentation can be accessed here:
http://www.teldat.com/conformity
Spanish (ES) Español Por la presente, Teldat S.A. declara que el tipo de equipo radioeléctrico Regesta
Smart PRO es conforme con:
The EC declaration of conformity and additional product documentation can be accessed here:
http://www.teldat.com/conformity
5.5 CE marking
This equipment is in conformity with the CE procedures and marking.
5.8 REACH
In compliance with the REACH Candidate List, the delivered product and product packaging do not contain chemical
substances above a concentration limit of 0.1% weight by weight (w/w). This declaration will be updated whenever
any changes occur or other chemical substances are added to the REACH Candidate List. Information is currently
provided to consumers upon request.
A.1 Connectors
1 BI-DA+ BI-DA+
2 BI-DA- BI-DA-
3 BI-DB+ BI-DB+
4 -- BI-DC+
5 -- BI-DC-
6 BI-DB- BI-DB-
7 -- BI-DD+
8 -- BI-DD-
1 BI-DA+ BI-DA+
2 BI-DA- BI-DA-
3 BI-DB+ BI-DB+
4 -- BI-DC+
5 -- BI-DC-
6 BI-DB- BI-DB-
7 -- BI-DD+
8 -- BI-DD-
SFP
1 BI-DA+ BI-DA+
2 BI-DA- BI-DA-
3 BI-DB+ BI-DB+
4 -- BI-DC+
5 -- BI-DC-
6 BI-DB- BI-DB-
7 -- BI-DD+
8 -- BI-DD-
Internal RF in/out
External GND
1 --
2 RxD
3 GND
4 --
5 --
6 GND
7 TxD
8 --
1 RTS
2 DTR
3 TxD
4 GND
5 CD
6 RxD
7 DSR
8 CTS
2 2H_R/TX-_4H_TX-
3 2H_R/TX+_4H_TX+
4 GND
6 4H_RX+
7 4H_RX-
- DC-powered version:
PORTS 4-port or 2-port switch managed with MDI/MDX auto-detection depending on the
model
1000-Base-X.
• LTE:
• FDD. B1, B3, B5, B7, B8, B20
• TDD: B38, B40, B41
• WCDMA: B1, B5, B8
• GSM/GPRS/EDGE: 900/1800 MHz
• LTE Cat 4.
• FDD. 150Mbps/50Mbps
• TDD: 130Mbps/35Mbps
• HSPA+ Cat 24/6: 42Mbps/5.76Mbps
• EDGE: 236Kbps
STANDARDS 2-4 wire RS-485/RS-422 configurable via software. Bus termination configurable
via software.
SPEED From 300 to 115200 bps.
A.2.10.1 AC model
FREQUENCY 50-60 Hz
MAXIMUM POWER 10 W
Terminal Block 2 Poles 5.08 mm pitch.
CONNECTOR
A.2.10.2 DC model
NOMINAL 12-72 V DC
9 - 80 V DC
ABSOLUTE MAXIMUM
MAXIMUM POWER 10 W
Terminal Block 2 Poles 5.08 mm pitch.
CONNECTOR
A.2.10.3 MR model
NOMINAL 110-240 V AC
48-72 V DC
40 - 85 V DC
MAXIMUM POWER 10 W
Terminal Block 2 Poles 5.08 mm pitch.
CONNECTOR
WEIGHT 1 Kg.
RELATIVE HUMIDITY 5 % to 93 %
This product is supplied without antennas. Choosing antennas is at the discretion of the operator, but said party is re-
sponsible for ensuring they comply with local regulations.
Technology: LTE.