User manual for access control GM65-216

Technical parameter:
Power supply: DC10V--24V
Standby current: 6mA(DC12V)
Output: Relay(Max. current: 10A)
Bar code capacity: Group 1: 20 pieces Group 2: 20pieces
Group 3:One-time bar code:10 pieces
Control board management: SET Button or Remote control

Instructions:
1. SET Button:
1.1 Press SET button shortly,system in register state and indicator light flash fast,
register bar code and when hearing music means register successfully.Can be
registered continuously when system in register state; if no need adding more, wait a
few seconds to exit.(Can register 40 pieces bar code when press SET button, register
in group 1, group 2 in turn)
1.2 When back to factory default, press SET button until hear “Di” long beep and
music,means initialization operation successful.

2. Remote Control:
Red indicator lighted means in programming stated, music means operation successful,
default password: 123456,password length: 6 numbers
2.1 Change password: Press *password*1*new password*new password#
2.2 Register bar code:
Register Group 1: Press *Password*2*1# 20 pieces capacity

www.hzgrow.com
Register Group 2: Press *Password*2*2# 20 pieces capacity
Register Group 3: Press *Password*2*3# 10 pieces capacity One-time bar code
Exit bar code in register state when press * button or waiting a few seconds
2.3. Empty: Press *password*3*password#
2.4. Delay time for closing relay: Press *password*5*SS #; SS from 00 to 20, SS means
the closing time for relay(from 0.5s to 20s), e.g.: 00 means 0.5s, 20 means 20s; Default
time is 5s. (e.g.:Set 2s: Press *Password*5*02#)
2.5. Delete bar code: Delete Group 1: Press*Password*6*1#
Delete Group 2: Press*Password*6*2#
Delete Group 3: Press*Password*6*3#
2.6. Scan Head Lighting: Close: Press*Password*7*0#
Open: Press*Password*7*1#
2.7. Scan Head Collimation: Close: Press*Password*8*0#
Open: Press*Password*8*1#
2.8. Password Using: Press *password and relay closed, press # and relay opened.

3. Function Set:
When chose 1, closing time of the relay is 5s after pass bar code(5s is default time, and it
can be adjusted by remote control from 0.5-20s); When chose 2, closing time of the relay
is 0.5s after pass bar code.

4. Connection:

UART

Note:
1) The same bar code only can be registered once, if repeated registration, there will be an
error and warning sound.
2) One-time bar code can be re-registered,the number of uses is equal to the number of
repeated registrations.
3) If the bar code has been registered in Group 1 or Group 2, the bar code cannot be
registered as a one-time bar code.