Professional Documents
Culture Documents
Report
Project
Customer:
Project Name: Project
Location: Peru, LIMA
Date: 2024-01-09
Designer
Name:
Phone:
Email:
Address:
Software
Version: 2.0.1.1
DB version: 20240104-224105
Table of Abbreviations
Abbreviation Description
Add. Ref. Additional Refrigerant
AM Airflow Mode
Block Load Block Load
CM Cooling Operation Mode
Corr. Capa Correction Capacity
Corr. PI Correction Power Input
CR Combination Ratio
DB Dry Bulb Temperature
Des Temp Design Temperature
Dis. Temp. Discharge Temperature
Equip. Name Equipment Name
EWT Entering Water Temperature
FR Flow Rate
HM Heating Operation Mode
IDU Indoor Unit
LWT Leaving Water Temperature
Max. Capa Maximum Capacity
Min. HOR Minimum Heating Operation Ratio
ODU Outdoor Unit
Op. WF Range Operating Water Flow Range
Op. WT Range Operating Water Temperature Range
Operating Temp. Range Operating Temperature Range
PHE Plate Heat Exchanger
Pipe Mat. Piping Material
PL Pressure Loss
PWL Sound Power level
Ref. Pipe Refrigerant Pipe
Rq. Vent. Vol. Required Ventilation Volume
SHC Sensible Heat Capacity
SPL Sound Pressure Level
TC Total Capacity
WB Wet Bulb Temperature
47/43, 120 DB / WB, LWT (for DVM Chiller Heating capacity)
DVM Pro 2.0
Equipment List
Type Model Code Description Unit Qty.
AM320CXVAFH/AZ
ODU -AM120CXVAFH/AZ x 1 DVM S2 Heat Pump EA 1
-AM200CXVAFH/AZ x 1
AM054KNMDCH1AZ 중정압 덕트 EA 2
MXJ-YA2512M Y-joint EA 4
MXJ-YA2815M Y-joint EA 2
Pipe Mat.
MXJ-YA3419M Y-joint EA 1
Piping
System (System1)
Design Condition
Outdoor Indoor
Design Condition (Air)
CM HM CM HM
Temperature (DB/WB) [°C] 29.9 / 24.1 14.5 / 9.3 27.0 / 19.0 20.0 / 15.0
Altitude Correction -
Installation
Type Floor Room Name Equip. Name Model Code
- IDU1 AM048NN4DCH/AA
1F
- IDU2 AM048NN4DCH/AA
- IDU3 AM036NN4DCH/AA
2F
- IDU4 AM036NN4DCH/AA
IDU
- IDU5 AM048NN4DCH/AA
3F
- IDU7 AM012TNVDCH/AA
- IDU8 AM054KNMDCH1AZ
4F
- IDU9 AM054KNMDCH1AZ
Outdoor Unit
CM HM CM HM
Indoor Unit
Des Temp[°C] Max. Capa. [Btu/h] Corr. Capa. [Btu/h]
IN WB IN DB TC SHC TC TC SHC TC
IDU1 AM048NN4DCH/AA H 19.00 20.00 47173.00 33945.00 55120.00 47056.00 33861.00 53682.00
IDU2 AM048NN4DCH/AA H 19.00 20.00 47173.00 33945.00 55120.00 47056.00 33861.00 53682.00
IDU3 AM036NN4DCH/AA H 19.00 20.00 35413.00 26191.00 40920.00 35325.00 26126.00 39852.00
IDU4 AM036NN4DCH/AA H 19.00 20.00 35413.00 26191.00 40920.00 35325.00 26126.00 39852.00
IDU5 AM048NN4DCH/AA H 19.00 20.00 47173.00 33945.00 55120.00 47056.00 33861.00 53682.00
IDU7 AM012TNVDCH/AA H 19.00 20.00 12000.00 8000.00 13500.00 11970.00 7980.00 13148.00
IDU8 AM054KNMDCH1AZ H 19.00 20.00 53067.00 41893.00 61920.00 52935.00 41789.00 60305.00
IDU9 AM054KNMDCH1AZ H 19.00 20.00 53067.00 41893.00 61920.00 52935.00 41789.00 60305.00
DVM Pro 2.0
Piping (Continued)
System1 AM320CXVAFH/AZ - - - -
IDU1 AM048NN4DCH/AA - - - -
IDU2 AM048NN4DCH/AA - - - -
IDU3 AM036NN4DCH/AA - - - -
IDU4 AM036NN4DCH/AA - - - -
IDU5 AM048NN4DCH/AA - - - -
IDU7 AM012TNVDCH/AA - - - -
IDU8 AM054KNMDCH1AZ - - - -
IDU9 AM054KNMDCH1AZ - - - -
Combination Ratio
Pipe length from first Y-Joint to the farthest IDU is 13.20 m (Restriction: 45.00 m). 45.00 m 13.20 m
Height difference between ODU and IDU is 7.00 m (restriction: 110.00 m) (ODU higher
110.00 m 7.00 m
than IDUs).
Height difference between ODU and IDU is 2.00 m (restriction: 110.00 m) (ODU lower
110.00 m 2.00 m
than IDUs).
Height difference between IDUs when there is no wall mounts with EEV is 9.00 m
50.00 m 9.00 m
(restriction: 50.00 m).
Height difference between IDUs when there are wall mounts with EEV is 9.00 m
30.00 m 9.00 m
(restriction: 30.00 m).
DVM Pro 2.0
Piping (Continued)
Height difference between the lowest IDU and the highest wall mount with EEV is 6.00
15.00 m 6.00 m
m (restriction: 15.00 m).
Refrigerant
Factory Charging and Additional Refrigerant Amount Refrigerant Amount [kg]
Total 28.10
DVM Pro 2.0
Piping (Continued)
-The above system configuration may differ from The actual installation conditions.
Please refer to The installation manual for full details.
DVM Pro 2.0
-The above system configuration may differ from The actual installation conditions.
Please refer to The installation manual for full details.
DVM Pro 2.0
Controller
Controller Diagram
-The above system configuration may differ from The actual installation conditions.
Please refer to The installation manual for full details.
DVM Pro 2.0
Wiring
System (System1)
Wiring Diagram
-The above system configuration may differ from The actual installation conditions.
Please refer to The installation manual for full details.
DVM Pro 2.0
Product Specification
System1
Outdoor Unit
Model Name AM320CXVAFH/AZ
Module Module
Mode HP
HP 32
Fin Al
Heat Exchanger Material
Tube Cu
Compressor Quantity EA 3
Type Propeller
Fan
Discharge direction Top discharge
Type BLDC
Fan Motor
Quantity EA 3
Type Welding
Liquid Pipe
Piping Diameter in 3/4''
Connections Type Welding
Gas Pipe
Diameter in 1 3/8''
Type R410A
Refrigerant
Factory Charging kg 17.5
Sound
Cooling dB(A) 64.1
Sound Pressure
Sound
Cooling dB(A) 85
Power Level
DVM Pro 2.0
Product Specification
System1 (Continued)
Outdoor Unit
Min. °C -15
Cooling
Operating Max. °C 50
Temp. Range Min. °C -25
Heating
Max. °C 24
DVM Pro 2.0
Product Specification
System1 (Continued)
Indoor Unit
Model Name AM048NN4DCH/AA
Mode HP/HR
MBH 48
MOP A 15
Current
Quantity EA 1
FLA
A A 0.39
Type Turbo
High CMM 29
Fan
Air Flow Rate Mid CMM 27
Low CMM 24
Type BLDC
Output W 97
Type Flaring
Liquid Pipe
Diameter in 3/8''
Piping
Type Flaring
Connections Gas Pipe
Diameter in 5/8''
Type R410A
Refrigerant
Control Type EEV included
Sound High dB(A) 45
Sound Pressure
Level Mid dB(A) 42
DVM Pro 2.0
Product Specification
System1 (Continued)
Indoor Unit
Sound
Low dB(A) 39
Sound Pressure
Sound
Cooling dB(A) 60
Power Level
Net Weight kg 8.39
W mm 840
W mm 898
D mm 898
DVM Pro 2.0
Product Specification
System1 (Continued)
Indoor Unit
Model Name AM036NN4DCH/AA
Mode HP/HR
MBH 36
MOP A 15
Current
Quantity EA 1
FLA
A A 0.39
Type Turbo
High CMM 24
Fan
Air Flow Rate Mid CMM 22
Low CMM 20
Type BLDC
Output W 97
Type Flaring
Liquid Pipe
Diameter in 3/8''
Piping
Type Flaring
Connections Gas Pipe
Diameter in 5/8''
Type R410A
Refrigerant
Control Type EEV included
Sound High dB(A) 42
Sound Pressure
Level Mid dB(A) 39
DVM Pro 2.0
Product Specification
System1 (Continued)
Indoor Unit
Sound
Low dB(A) 36
Sound Pressure
Sound
Cooling dB(A) 58
Power Level
Net Weight kg 8.39
W mm 840
W mm 898
D mm 898
DVM Pro 2.0
Product Specification
System1 (Continued)
Indoor Unit
Model Name AM012TNVDCH/AA
Mode HP/HR
MBH 12
MOP A 15
Current
Quantity EA 1
FLA
A A 0.25
Type F&T
Fin Al
Heat Exchanger Material
Tube Cu
Type BLDC
Output W 27
Type Flaring
Liquid Pipe
Diameter in 1/4''
Piping
Type Flaring
Connections Gas Pipe
Diameter in 1/2''
Type R410A
Refrigerant
Control Type EEV included
Sound
Sound High dB(A) 40
Pressure
DVM Pro 2.0
Product Specification
System1 (Continued)
Indoor Unit
Sound Mid dB(A) 36
Pressure
Sound Level Low dB(A) 34
Sound
Cooling dB(A) 56
Power Level
Net Weight kg 9.48
W mm 820
W mm 879
D mm 376
DVM Pro 2.0
Product Specification
System1 (Continued)
Indoor Unit
Model Name AM054KNMDCH1AZ
Mode HP/HR/CO
kW 16
Fin Al
Heat Exchanger Material
Tube Cu
High CMM 43
Min Pa 39.23
External Static
Standard Pa 78.45
Pressure
Max Pa 137.29
Type BLDC
Output W 370
Type Flaring
Liquid Pipe
Diameter in 3/8''
Piping
Type Flaring
Connections Gas Pipe
Diameter in 5/8''
Type R410A
Refrigerant
Control Type EEV included
Sound High dB(A) 43
Sound Pressure
Level Mid dB(A) 40
DVM Pro 2.0
Product Specification
System1 (Continued)
Indoor Unit
Sound
Low dB(A) 36
Sound Pressure
Sound
Cooling dB(A) 69
Power Level
W mm 1200
External D mm 650
Dimension W mm 1480
D mm 790