Engineering Data
Table of Contents
1
FXFQ-TVJUEDUS391400B-F14
FEATURES
True 360° airflow distribution and three room sensors enables optimized occupant comfort and
efficiency
Optional self-cleaning filter panel to further increase efficiency and reduce maintenance costs
Individually controlled supply air louvers for comfortable air supply
Improved efficiency with new DC fan motor and auto logic that adjusts fan speed based on
space load
Industry leading flexibility with 23 possible airflow patterns
Integral condensate pump with up to 26-1/2" lift
Standard Limited Warranty: 10-year warranty on compressor and all parts
BENEFITS
Compact design to allow for installation in small ceiling voids
Very low sound levels increases flexibility regarding location of the unit
Increased indoor air quality with high efficiency filter options & ventilation connection kit
Automatic occupancy dependant Set back function to save energy
2
FXFQ-TVJUEDUS391400B-F14
2. Specifications
Note:
+1. Nominal cooling capacities are based on the following conditions:
Return air temperature: 80°FDB (26.7°CDB), 67°FWB (19.4°CWB)
Outdoor temperature: 95°FDB (35.0°CDB)
Equivalent refrigerant piping length: 25 ft (7.6 m) (horizontal)
+2. Nominal heating capacities are based on the following conditions:
Return air temperature: 70°FDB (21.1°CDB).
Outdoor temperature: 47°FDB (8.3°CDB), 43°FWB (6.1°CWB)
Equivalent refrigerant piping length: 25 ft (7.6 m) (horizontal)
+3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
+4. Anechoic chamber conversion value, measured under JIS conditions. During actual operation,
these values may be higher as a result of installation conditions.
C: 3D086889B
3
FXFQ-TVJUEDUS391400B-F14
Note:
+1. Nominal cooling capacities are based on the following conditions:
Return air temperature: 80°FDB (26.7°CDB), 67°FWB (19.4°CWB)
Outdoor temperature: 95°FDB (35.0°CDB)
Equivalent refrigerant piping length: 25 ft (7.6 m) (horizontal)
+2. Nominal heating capacities are based on the following conditions:
Return air temperature: 70°FDB (21.1°CDB).
Outdoor temperature: 47°FDB (8.3°CDB), 43°FWB (6.1°CWB)
Equivalent refrigerant piping length: 25 ft (7.6 m) (horizontal)
+3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
+4. Anechoic chamber conversion value, measured under JIS conditions. During actual operation,
these values may be higher as a result of installation conditions.
C: 3D086889B
4
FXFQ-TVJUEDUS391400B-F14
Note:
+1. Nominal cooling capacities are based on the following conditions:
Return air temperature: 80°FDB (26.7°CDB), 67°FWB (19.4°CWB)
Outdoor temperature: 95°FDB (35.0°CDB)
Equivalent refrigerant piping length: 25 ft (7.6 m) (horizontal)
+2. Nominal heating capacities are based on the following conditions:
Return air temperature: 70°FDB (21.1°CDB).
Outdoor temperature: 47°FDB (8.3°CDB), 43°FWB (6.1°CWB)
Equivalent refrigerant piping length: 25 ft (7.6 m) (horizontal)
+3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
+4. Anechoic chamber conversion value, measured under JIS conditions. During actual operation,
these values may be higher as a result of installation conditions.
C: 3D086889B
5
FXFQ-TVJUEDUS391400B-F14
Note:
+1. Nominal cooling capacities are based on the following conditions:
Return air temperature: 80°FDB (26.7°CDB), 67°FWB (19.4°CWB)
Outdoor temperature: 95°FDB (35.0°CDB)
Equivalent refrigerant piping length: 25 ft (7.6 m) (horizontal)
+2. Nominal heating capacities are based on the following conditions:
Return air temperature: 70°FDB (21.1°CDB).
Outdoor temperature: 47°FDB (8.3°CDB), 43°FWB (6.1°CWB)
Equivalent refrigerant piping length: 25 ft (7.6 m) (horizontal)
+3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
+4. Anechoic chamber conversion value, measured under JIS conditions. During actual operation,
these values may be higher as a result of installation conditions.
C: 3D086889B
6
FXFQ-TVJUEDUS391400B-F14
Model FXFQ48TVJU
Power supply 1 phase, 60 Hz, 208/230 V
Btu/h
H1, H3 Cooling capacity 48,000 (14.1)
(kW)
Btu/h
H2, H3 Heating capacity 54,000 (15.8)
(kW)
Casing/Color Galvanized steel plate
Dimensions: (H × W × D) in. (mm) 11-5/16 × 33-1/16 × 33-1/16 (288 × 840 × 840)
Coil (cross Rows × Stages × FPI 3 × 18 × (20 + 21 × 2)
fin coil) Face area ft² (m²) 5.92 (0.550)
Model QTS48C15M
Type Turbo fan
Fan Motor output W 106
cfm
Airflow rate (HH/H/L) (m³/min) 1,218/971/742 (34.5/27.5/21.0)
Drive Direct drive
Temperature control Microprocessor thermostat for cooling and heating
Sound absorbing thermal insulation material Polyurethane form
4 Sound pressure level (reference dBA 45.0/40.0/35.0
data) (HH/H/L)
H4 Sound power level (reference data) dB 61
Weight lbs (kg) 58 (26)
Liquid pipes in. (mm) f3/8 (f9.5) (flare connection)
Piping Gas pipes in. (mm) f5/8 (f15.9) (flare connection)
connections VP25
Drain pipe in. (mm) (external dia. 1-1/4 (32), internal dia. 1 (25))
Safety devices Fuse
Refrigerant control Electronic expansion valve
Connectable outdoor unit R410A VRV series
Operation manual, Installation manual, Paper pattern for installation, Drain hose, Sealing pads,
Standard accessories Clamps, Washers, Screws, Insulation for fitting, Clamp metal
Model BYCQ125B-W1 / BYCQ125BGW1
Decoration Color Fresh white
panel Dimensions: (H × W × D) in. (mm) 2 × 37-3/8 × 37-3/8 / 5-1/8 × 37-3/8 × 37-3/8 (50 × 950 × 950 / 130 × 950 × 950)
(option) Air filter Resin net (with mold resistance)
Weight lbs (kg) 12.2/22.1 (5.5/10.0)
Note:
+1. Nominal cooling capacities are based on the following conditions:
Return air temperature: 80°FDB (26.7°CDB), 67°FWB (19.4°CWB)
Outdoor temperature: 95°FDB (35.0°CDB)
Equivalent refrigerant piping length: 25 ft (7.6 m) (horizontal)
+2. Nominal heating capacities are based on the following conditions:
Return air temperature: 70°FDB (21.1°CDB).
Outdoor temperature: 47°FDB (8.3°CDB), 43°FWB (6.1°CWB)
Equivalent refrigerant piping length: 25 ft (7.6 m) (horizontal)
+3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
+4. Anechoic chamber conversion value, measured under JIS conditions. During actual operation,
these values may be higher as a result of installation conditions.
C: 3D086889B
7
FXFQ-TVJUEDUS391400B-F14
3. Simplified Dimensions
FXFQ07-18TVJU
C: DFT5186706
12.7
6.4
1/4
1/2
8
FXFQ-TVJUEDUS391400B-F14
FXFQ24TVJU
DFT5186705
9
FXFQ-TVJUEDUS391400B-F14
FXFQ30-48TVJU
DFT5178644
10
FXFQ-TVJUEDUS391400B-F14
FXFQ07-18TVJU
3D086960C
11
FXFQ-TVJUEDUS391400B-F14
FXFQ24TVJU
3D086962C
12
FXFQ-TVJUEDUS391400B-F14
FXFQ30-48TVJU
3D086983C
13
FXFQ-TVJUEDUS391400B-F14
FXFQ07-18TVJU
3D086963B
14
FXFQ-TVJUEDUS391400B-F14
FXFQ24TVJU
3D086982B
15
FXFQ-TVJUEDUS391400B-F14
FXFQ30-48TVJU
3D086986B
16
FXFQ-TVJUEDUS391400B-F14
6. Center of Gravity
FXFQ07-48TVJU
C: 4D070529D
17
FXFQ-TVJUEDUS391400B-F14
7. Piping Diagrams
FXFQ07-48TVJU
4D024460P
18
FXFQ07-48TVJU
8. Wiring Diagrams
19
NOTES
1. : TERMINAL BLOCK, , : CONNECTOR, : FIELD WIRING
2. IN CASE USING CENTRAL REMOTE CONTROLLER, CONNECT IT TO THE UNIT IN ACCORDANCE WITH THE ATTACHED INSTALLATION MANUAL.
3. WHEN CONNECTING THE INPUT WIRING FROM OUTSIDE, FORCED OFF OR ON/OFF CONTROL OPERATION CAN BE SELECTED BY THE REMOTE CONTROLLER.
SEE INSTALLATION MANUAL FOR MORE DETAILS.
4. IN CASE OF MAIN/SUB CHANGEOVER, SEE THE INSTALLATION MANUAL ATTACHED TO REMOTE CONTROLLER.
5. CONNECT POWER SUPPLY OF ADAPTOR FOR WIRING TO TERMINAL BLOCK (X2M) OF INDOOR UNIT DIRECTLY.
6. X8A, X33A, X35A, X36A ARE CONNECTED WHEN THE OPTIONAL ACCESSORIES ARE BEING USED. IN CASE OF USING A SELF CLEAN PANEL, SEE THE WIRING
DIAGRAM OF IT.
7. SYMBOLS SHOW AS FOLLOWS: RED: RED BLK: BLACK WHT: WHITE YLW: YELLOW GRN: GREEN ORG: ORANGE BRN: BROWN PNK: PINK BLU: BLUE
8. CLASS 2 WIRE
C: 3D086460B
FXFQ-TVJUEDUS391400B-F14
FXFQ-TVJUEDUS391400B-F14
FXFQ07-48TVJU
INDOOR UNIT
A1P PRINTED CIRCUIT BOARD
A2P PRINTED CIRCUIT BOARD
A3P PRINTED CIRCUIT BOARD (INFRARED FLOOR SENSOR)
A4P PRINTED CIRCUIT BOARD (INFRARED PRESENCE SENSOR)
C21 CAPACITOR
C105 CAPACITOR
F1U FUSE (T, 3.15 A, 250 V)
HAP FLASHING LAMP (A1P, A2P) (SERVICE MONITOR GREEN)
M1F MOTOR (INDOOR FAN)
M1P MOTOR (DRAIN PUMP)
M1S~M4S MOTOR (SWING BLADE)
R1T THERMISTOR (AIR)
R2T·R3T THERMISTOR (COIL)
S1L FLOAT SWITCH
V1R DIODE BRIDGE
X1M TERMINAL BLOCK
X2M TERMINAL BLOCK
Y1E ELECTRONIC EXPANSION VALVE
Z1C FERRITE CORE
Z1F NOISE FILTER
PS POWER SUPPLY CIRCUIT (A1P, A2P)
CONNECTOR FOR OPTIONAL PARTS
X8A CONNECTOR (SELF CLEAN PANEL)
X33A CONNECTOR (ADAPTOR FOR WIRING)
X35A CONNECTOR (POWER SUPPLY FOR ADAPTOR)
X36A CONNECTOR (SELF CLEAN PANEL)
C: 3D086460B
20
FXFQ-TVJUEDUS391400B-F14
9. Electric Characteristics
FXFQ07-48TVJU
Symbol:
MCA: Min. Circuit Amps (A)
MOP: Max. Overcurrent Protective Device (A)
KW: Fan Motor Rated Output (kW)
FLA: Full Load Amps (A)
IFM: Indoor Fan Motor
Note:
1. Voltage range
Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed range limits.
2. Maximum allowable voltage unbalance between phases is 2%.
3. MCA/MOP
MCA = 1.25 × FLA
MOP ≤ 4 × FLA
(Next lower standard fuse raring. Min. 15 A)
4. Select wire size based on the MCA.
C: 4D086936A
21
FXFQ-TVJUEDUS391400B-F14
22
FXFQ-TVJUEDUS391400B-F14
Note:
1. These capacity tables can be used when selecting a VRV indoor unit. The actual capacity of the VRV system depends on factors such as the
selected model of outdoor units, outdoor air temperature and piping length. Please confirm that the corrected capacity of the VRV system satisfies
the required heat load.
2. shows rated condition.
CA14A023A
Note:
1. These capacity tables can be used when selecting a VRV indoor unit. The actual capacity of the VRV system depends on factors such as the
selected model of outdoor units, outdoor air temperature and piping length. Please confirm that the corrected capacity of the VRV system satisfies
the required heat load.
2. shows rated condition.
CA14A023A
23
FXFQ-TVJUEDUS391400B-F14
Refer to the correction factor table below when a mini-split indoor unit
is connected to a VRV Heat Pump system using a Branch Port box.
Indoor air temp. °FWB (°CWB) (Te: 48°F (9°C))
Model 61 (16.1) 64 (17.8) 67 (19.4) 70 (21.1) 72 (22.2) 75 (23.9)
TC SHF TC SHF TC SHF TC SHF TC SHF TC SHF
FXFQ07TVJU 0.72 1.16 0.77 1.11 0.80 1.08 0.83 1.06 0.85 1.05 0.87 1.03
FXFQ09TVJU 0.72 1.16 0.77 1.11 0.80 1.08 0.83 1.06 0.85 1.05 0.87 1.03
FXFQ12TVJU 0.72 1.16 0.77 1.11 0.80 1.08 0.83 1.06 0.85 1.05 0.87 1.03
FXFQ15TVJU 0.72 1.16 0.78 1.11 0.81 1.08 0.83 1.06 0.85 1.05 0.87 1.03
FXFQ18TVJU 0.69 1.18 0.75 1.13 0.78 1.09 0.81 1.07 0.83 1.05 0.85 1.03
FXFQ24TVJU 0.69 1.18 0.75 1.13 0.78 1.09 0.81 1.07 0.83 1.05 0.85 1.03
FXFQ30TVJU 0.69 1.18 0.75 1.13 0.78 1.09 0.81 1.07 0.83 1.05 0.85 1.04
FXFQ36TVJU 0.69 1.18 0.75 1.13 0.78 1.09 0.81 1.07 0.83 1.05 0.85 1.04
FXFQ48TVJU 0.69 1.18 0.75 1.13 0.78 1.09 0.81 1.07 0.83 1.05 0.85 1.04
24
FXFQ-TVJUEDUS391400B-F14
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
25
FXFQ-TVJUEDUS391400B-F14
FXFQ09TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
26
FXFQ-TVJUEDUS391400B-F14
FXFQ12TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
27
FXFQ-TVJUEDUS391400B-F14
FXFQ15TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
28
FXFQ-TVJUEDUS391400B-F14
FXFQ18TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
29
FXFQ-TVJUEDUS391400B-F14
FXFQ24TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
80.6°F (27°C)
8.9 ft
(2.7 m) 79°F (26°C)
77°F (25°C)
75.2°F (24°C)
73.4°F (23°C)
71.6°F (22°C)
69.8°F (21°C)
68°F (20°C)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
30
FXFQ-TVJUEDUS391400B-F14
FXFQ30TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
80.6°F (27°C)
8.9 ft
(2.7 m) 79°F (26°C)
77°F (25°C)
75.2°F (24°C)
73.4°F (23°C)
71.6°F (22°C)
69.8°F (21°C)
68°F (20°C)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
31
FXFQ-TVJUEDUS391400B-F14
FXFQ36TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
32
FXFQ-TVJUEDUS391400B-F14
FXFQ48TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
33
FXFQ-TVJUEDUS391400B-F14
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
80.6°F (27°C)
8.9 ft
(2.7 m) 79°F (26°C)
77°F (25°C)
75.2°F (24°C)
73.4°F (23°C)
71.6°F (22°C)
69.8°F (21°C)
68°F (20°C)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
34
FXFQ-TVJUEDUS391400B-F14
FXFQ09TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
35
FXFQ-TVJUEDUS391400B-F14
FXFQ12TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
36
FXFQ-TVJUEDUS391400B-F14
FXFQ15TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
37
FXFQ-TVJUEDUS391400B-F14
FXFQ18TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
38
FXFQ-TVJUEDUS391400B-F14
FXFQ24TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
39
FXFQ-TVJUEDUS391400B-F14
FXFQ30TVJU
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
40
FXFQ-TVJUEDUS391400B-F14
FXFQ36TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
41
FXFQ-TVJUEDUS391400B-F14
FXFQ48TVJU
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
0.0 ft
(0.0 m)
0.0 ft 26.2 ft
(0.0 m) (8.0 m)
Note:
Please understand that the analysis results may differ with actual installation conditions, or
furniture arrangement.
42
FXFQ-TVJUEDUS391400B-F14
FXFQ07-12TVJU
4D087472A
43
FXFQ-TVJUEDUS391400B-F14
FXFQ15TVJU
4D087473A
44
FXFQ-TVJUEDUS391400B-F14
FXFQ18TVJU
4D087483A
45
FXFQ-TVJUEDUS391400B-F14
FXFQ24TVJU
4D087474A
46
FXFQ-TVJUEDUS391400B-F14
FXFQ30TVJU
4D087479A
47
FXFQ-TVJUEDUS391400B-F14
FXFQ36TVJU
4D087475A
48
FXFQ-TVJUEDUS391400B-F14
FXFQ48TVJU
4D087476A
49
FXFQ-TVJUEDUS391400B-F14
14. Accessories
14.1 Optional Accessories (for Unit)
FXFQ07TVJU FXFQ07TVJU
FXFQ09TVJU FXFQ09TVJU
FXFQ30TVJU FXFQ30TVJU
FXFQ12TVJU FXFQ12TVJU
Option Note FXFQ36TVJU FXFQ36TVJU
FXFQ15TVJU FXFQ15TVJU
FXFQ48TVJU FXFQ48TVJU
FXFQ18TVJU FXFQ18TVJU
FXFQ24TVJU FXFQ24TVJU
WHEN USING SELF CLEANING DECO
Type of decoration panel WHEN USING STANDARD DECO PANEL
PANEL
Self cleaning decoration panel BYCQ125BGW1 —
Connection pipe (Nozzule for dust recovery) KKHAP55B160 —
L-shape extension pipe KKHAP55A160 —
Decoration panel — BYCQ125B-W1
Sealing material of air discharge outlet KDBH55K160F KDBHQ55B140
Panel spacer KDB55J160F KDB55J160F
Without T-duct joint KDDQ55B140
—
Chamber [KDDP55C160-1, KDDQ55B140-2]
Fresh air type
intake kit KDDP55B160K
With T-duct joint — [KDDP55C160-1, KDDP55B160K2]
Direct installation type — KDDP55X160A
Filter chamber — KDDFP55C160
Ultra long life filter unit — KAF555D160
Replacement ultra long life filter — KAF550D160
Replacement filter for self cleaning decoration
KAFP554A160 —
panel
Branch duct chamber KDJP55B80 KDJP55B160 KDJP55B80 KDJP55B160
C: 3D086933C
50
BYCQ125BGW1EDUS391400B-F14
Appendix 1
Installation of Self Cleaning Decoration Panel
BYCQ125BGW1
1. Installation Manual....................................................................................... i
A1
BYCQ125BGW1EDUS391400B-F14
1. Installation Manual
BYCQ125BGW1
Note
• Have the customer actually operate the air conditioner while
referring to the operation manual and explain the right operation
of the air conditioner with useful tips given.
• Refer to the operation manual along with the installation manual
1. Safety Considerations provided with the indoor unit.
i
1 3P257556-2B English
English
3P257556-2B
i
3P257556_2B_EM13A021A.indb 1 2015/04/14 9:37:03
BYCQ125BGW1EDUS391400B-F14
CONTENTS
1. Safety Considerations .................................................................i
2. Instructions Peculiar to This Product...........................................i
3. Accessory ..................................................................................2
4. Installation Site ..........................................................................2
5. Preparations for Panel ...............................................................4
6. Preparations for Indoor Unit .......................................................5
7. Attaching Panel to Indoor Unit ...................................................6
8. Attaching Suction Grille and Decoration Corner Covers ............9
9. Operation Mode Settings .........................................................11
10. Field Settings ...........................................................................11
11. Test Operation .........................................................................12
3P257556-2B English 1
3P257556-2B
1
3P257556_2B_EM13A021A.indb 1 2015/04/14 9:37:03
BYCQ125BGW1EDUS391400B-F14
Spacer Flexible S-shaped Clamp 4-1 Select the installation site that meets the
Name (1) hose (2) pipe (3) Harness (4) (5) following conditions with the consent of the
Quantity 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs. customer
• The surface of the ceiling is not inclined.
Shape • Installation and service workspace is secured (see the following
illustrations).
Name Seal (6) • The panel indicators are seen with ease.
• The indoor and outdoor units, power cord, transmission wiring,
Quantity 1 pc. Others
and remote controller wiring are at least 3.5 feet (1 m) away from
• Operation manual TV or radio sets.
Shape
• Installation manual (The above is for the prevention of TV and radio interference.
Depending on the incoming signal strength, a distance of 3.5 feet
Pay the utmost attention to the following items when (1 m) may not be sufficient to eliminate noise.)
conducting installation work, and recheck the items on
completion of the work.
a. Test items on completion of work
Test items In case of failure Result
Is the air conditioner free of wiring and Operation failure
connection mistakes or omissions? and wire burnout
Are you sure that there is no space
Water leakage
between the ceiling and ceiling material?
Vibration, noise,
Are the fixing knobs (in 2 points) of the
and dust
dust box secured tightly?
collection failure
Vibration, noise,
Are the fixed knobs (in 5 points) of the
and dust
air filter secured tightly?
collection failure
Is the fall prevention cord for the dust
box and grille hooked to the mounting Fall
bracket?
Did you attach the control box cover,
dust box, flexible hose, S-shaped pipe, Noise and dust
suction grille, and decoration corner collection failure
covers?
* Be sure to recheck the items provided in the section “1. Safety
Considerations” on page i.
b. Test items before delivery
Test items Result
Was the test operation of the air conditioner finished?
Did you explain the operation method of the air
conditioner to the customer while showing the customer
the operation manual? *
Did you make mode settings for filter auto-cleaning
(automatic control operation settings or timer operation
settings with an operation time zone specified) and
provide information on the set mode operation of the air
conditioner to the customer?
Did you deliver the operation manual to the customer?
(Be sure to hand the customer the operation manual as
well as the installation manual.)
2 3P257556-2B English
3P257556-2B
2
3P257556_2B_EM13A021A.indb 2 2015/04/14 9:37:06
BYCQ125BGW1EDUS391400B-F14
Sensor
* From wall
60 (1500) or more (Note 3) 60 (1500) or more
60 (1500) or more
in. (mm)
Note:
1. A space to allow dust vacuuming is required.
2. This restriction applies to the exposed type lighting, but does not apply to the recessed type (which does not protrude below the ceiling line).
3. The clearance from the wall* will be 20 in. (500mm) or more if the air outlet is closed or the louver is controlled to “Blocked”. In addition, it
will be 8 in. (200mm) if the air outlet and the both right and left corners are all closed.
4. Refer to the operation manual provided with the remote controller for a setting method of the airflow directions of the louver Individual
Airflow Direction .
Suction
grille
3P257556-2B English 3
3P257556-2B
3
3P257556_2B_EM13A021A.indb 3 2015/04/14 9:37:07
BYCQ125BGW1EDUS391400B-F14
(1) Press the knobs of the suction grille and lift up the knobs. Do not impose force on the lead wires.
Packing material
(bottom)
Decoration panel
Knobs
(2) Remove the screws on the backside of the decoration corner
cover (with the display), open the cover, and remove the
connector attached to the front end of the lead wires from the
(2) Open the suction grille to an angle of approximately 45° and
printed circuit board.
remove the suction grille from the panel.
1
Screw Lead wires
Cover
2 3
45° Connector
Decoration corner cover
Printed (with display)
circuit board
Protective corrugated
cardboard (bottom) Panel
Note
5-3 Removal of dust box
Do not impose force on the louver, brush unit, or air filter when
handling the panel. Fixing knob Dust box
Fixing knob of dust box
Air filter Brush unit of dust box
and clasp
Panel
Louver
4 3P257556-2B English
3P257556-2B
4
3P257556_2B_EM13A021A.indb 4 2015/04/14 9:37:12
BYCQ125BGW1EDUS391400B-F14
(1) Turn the 2 fixing knobs of the dust box. 6-1 Attaching spacer (accessory (1))
Fixing knob
Dust box
Fixing knob
2
(3) Remove the fall prevention cord for the dust box from the clasp 3
bracket of the panel.
4
Remove the fall
prevention cord from
the clasp bracket. 1 Air bypass hole
2 Pasted to align with the air bypass hole
Dust box 3 Align the corners
Panel 4 Spacer (accessory (1))
Fall prevention cord
Clasp 6-2 Attaching harness (accessory (4))
(1) Remove the control box cover from the indoor unit.
Clamps
6. Preparations for Indoor Unit
WARNING
Check that the indoor and outdoor units are turned power off Screws Control box cover
before conducting wiring work. (2 points)
Loosen the screws (in 2 points) and slide the control box cover in
Otherwise, it may result in an electric shock.
the direction of the arrow to unhook the cover from the clamps.
CAUTION
• Conduct the following work after installing the indoor unit.
• Install the indoor unit according to the installation manual
provided with the indoor unit.
3P257556-2B English 5
3P257556-2B
5
3P257556_2B_EM13A021A.indb 5 2015/04/14 9:37:16
BYCQ125BGW1EDUS391400B-F14
1 Control box (2) Remove from the harness opening as described in “6.
2 Jumper connector Preparations for Indoor Unit” on page 5. Pull out the lead
wires disconnected from the decoration cover in the corner
(3) Connect the harness (accessory (4)) to the connectors (X8A, carefully so that lead wries are not caught by the mounting
X35A and X36A) and the three points of the harness on the bracket. See “5. Preparations for Panel” on page 4.
unit side.
(3) Put the mounting brackets (in 4 points) on the corners of the
1 panel to the hooks of the circumference of the indoor unit.
2
X35A X36A
(Hook the mounting bracket engraved with the PIPING SIDE
first, followed by the mounting bracket on the opposite angle
X8A side.)
At that time, pay attention that the harness and lead wires (on
3 the panel side) will not be caught between the panel and
4 indoor unit.
5
6 Note
Let go your hands after confirming that the mounting brackets
1 Harness on the unit side are engaged with the hooks.
2 Connector (4) Tighten the four hexagon head screws right under the
Be sure to connect them securely mounting bracket for approximately 3/16 in. (5 mm.) (The panel
3 Control box will move upward.)
4 Hook X35A, X36A
5 Harness (accessory (4)) (5) Turn the panel in the directions of the arrows so that the
6 Glass tube opening on the ceiling will be perfectly covered by the panel.
Note (6) Furthermore, tighten the screw (4) until the distance from the
lower part of the hook of the indoor unit to the lower part of the
Make sure that the connectors are securely connected, or
panel becomes 4-3/16 (107) to 4-7/16 in. (112 mm.)
otherwise the louver, brush unit, or air filter will not work.
7-2 (1)
6-3 Attaching control box cover
Hook Check window
Attach the control box cover in the order opposite to the procedure
in “6-2 Attaching harness (accessory (4))” on page 5 (1).
Note Temporary
Make sure that the wires or glass tube will not be caught by the latching brackets
control box cover. Before temporarily After temporarily
hooking hooking
WARNING 7-2 (3)
Arrange the electric wires neatly and attach the control box Hook
cover securely.
The electric wires being caught or the rising of the control box cover
may result in an electric shock or fire. Mounting bracket
Before hooking After hooking
6 3P257556-2B English
3P257556-2B
6
3P257556_2B_EM13A021A.indb 6 2015/04/14 9:37:19
BYCQ125BGW1EDUS391400B-F14
Lower part of hook of (2) Draw the harness and lead wires (on the panel side).
7-2 (6)
the indoor unit
Panel Panel
Indoor unit
4-3/16~4-7/16
(107~112)
(The ceiling is
omitted from the Lead wire
illustration for ease (on the panel side) Harness
of explanation)
Lower side
of panel
Indoor unit
Seal
Lower part of
hook of the
4-3/16~4-7/16 (107~112)
(3) Connect the connector of the lead wires and move the glass
Lower side of panel
tube to cover the connector part.
Panel Mounting bracket
Lead wire
Cross sections (4 points) (on the panel side) Harness
1
in. (mm)
Connector 2
Note Be sure to connect Move the
glass tube. Glass tube
them securely.
• Tighten the screws securely, or otherwise a defect as shown
below may result.
• Readjust the height of the indoor unit if there is a space between (4) Tighten and secure both ends of the glass tube with the
the ceiling and panel with the screws tightened securely. clamps on the glass tube together with provided clamps
(accessories (5)). Cut the excess portions of the clamps from
Air Height adjustments to the unit their roots after the both ends are secured.
leakage will be possible through the
holes on the corners of the Tighten the clamps
Air leakage panels without removing the
from the panel, provided that the
ceiling side. adjustments does not affect the
levelness or the drain piping of
Generation Drew condensation
the indoor unit. Refer to the
Cut the roots
of dirt installation manual of the indoor
or dripping unit to conduct the work. Clamp
(accessory (5))
(5) Return the connected lead wires to the space between the
indoor unit and panel.
Make sure that there is no space.
(Accommodate the lead wires in the shaded part shown in the
illustration.)
Note
7-3 Checking panel
Accommodate the lead wires carefully so that the lead wires
(1) Remove sealing of panel. do not come in contact with the air filter.
1 2 1
2
3 Connected Connected
lead wires Panel lead wires
4
Control box of
the indoor unit
1 Remove seal of panel
(6) Remove the control box cover from the indoor unit.
2 Insert the seal until the seal comes in contact with the
Refer to “6-2 Attaching harness (accessory (4))” on page 5.
clamp
3 Clamp Control box
4 Sealing (accessory (6))
Resin cover
Open the resin cover
3P257556-2B English 7
3P257556-2B
7
3P257556_2B_EM13A021A.indb 7 2015/04/14 9:37:22
BYCQ125BGW1EDUS391400B-F14
(7) Connect the swing lead wire connector to the Printed circuit (1) Hook the fall prevention cord for the dust box to the panel
board. clasp as shown in the illustration.
1 1
2
X9A
2
3
3
4
1 Printed circuit board 5
2 Connect the swing lead wire connector to the Printed
circuit board
1 Clasp
Be sure to connect them securely.
2 Hooked fall prevention cord
3 Swing lead wire (to X9A)
3 Panel
(8) Attach the control box cover in the order opposite to the 4 Fall prevention cord
procedure in “6-2 Attaching harness (accessory (4))” on 5 Dust box
page 5.
(2) Attach the dust box in the order opposite to the procedure in
“5-3 Removal of dust box” on page 4.
2 Note
1 Make sure that the fall prevention cord is not caught by the
exhaust opening on the dust box when attaching the dust box.
Otherwise, the dust box may not function normally.
3
(3) Turn the fixing knobs (in 2 points) of the dust box and secure
4 the dust box.
Cut the extra end of the
clamp
Fixing
knob
1 Swing motor lead wire, sensor lead wire, harness (1)
2 Control box
3 Close the resin cover
4 Secure with the clamp (accessory (5))
(9) Guide the lead wires through the hook.
Fixing
knob
(The front side of the panel is shown
for ease of explanation.)
1 2
7-5 Mounting S-shaped pipe (accessory (3))
Mount the dust box side (engraved with A) before mounting the
1 Hook
brush side (engraved with B).
2 Guide the wires through the hook
(Mount them so that the engraved characters will be in conformity.)
7-4 Attaching dust box Dust box
Brush unit
1
2
3
b
8 3P257556-2B English
3P257556-2B
8
3P257556_2B_EM13A021A.indb 8 2015/04/14 9:37:26
BYCQ125BGW1EDUS391400B-F14
8. Attaching Suction Grille and (3) Connect the flexible hose (accessory (2)) onto the panel side.
(The flexible hose (accessory (2)) has no directionality constraint.)
Decoration Corner Covers
The suction grille can be rotated and attached in two directions, Flexible hose junction
either one of which is selectable. on the panel side
If a number of units are installed, adjust the directions of the suction
grilles if necessary. Make directional changes as well at the request
of the customer.
Note
Be sure not to break the flexible hose when press fitting the
Panel flexible hose.
Flexible
Panel Suction hose
grille
Suction
grille
45°
(2) As shown in the illustration, hook the fall prevention cords for Press fit the
flexible hose To suction grille
the suction grille to the corner clasps (on 2 corners). along the shape
of the corner.
Change the directions of
the fall prevention cords.
(5) Connect the opposite end of the flexible hose connected in (3)
onto the suction grille side.
* Rotate the flexible hose joint on the suction grille side
according to the mounting direction of the suction grille as
shown in the illustration.
Flexible hose
Flexible hose joint on joint on the
Suction grille the suction grille side suction grille side
Note
Check that the clamps are engaged securely. Otherwise, a
Fall prevention cord dust collection failure may result.
3P257556-2B English 9
3P257556-2B
9
3P257556_2B_EM13A021A.indb 9 2015/04/14 9:37:30
BYCQ125BGW1EDUS391400B-F14
(6) Push up the suction grille slowly first, and while pressing the (3) Connect the flexible hose (accessory (2)) onto the panel side.
two knobs, finally fit the grille into the panel securely. (The flexible hose (accessory (2)) has no directionality
constraint.)
Panel
Knobs
(2 points) Flexible hose junction
on the panel side
Suction grille
Note
The suction grille can catch the fall prevention cords while the Flexible hose
suction grille is closed. (accessory (2)) Fit the clamps into the
Check that the fall prevention cords do not protrude from the hooks (in 2 points)
Flexible hose junction
suction grille before closing the suction grille. securely.
on the panel side
Suction grille
Must not protrude
Hooks
(2 points)
Fall prevention
Note
cord
Check that the clamps are engaged securely. Otherwise, a
dust collection failure may result.
(4) Press fit the flexible hose connected in (3) into the panel.
8-3 Hook (B) Make sure that the hose will not be caught while closing the
suction grille.
(1) Set the suction grille to an angle of approximately 45° and put
the hooks (in 3 points) onto the panel. To suction grille
Display on Flexible
SUCTION GRILLE HOOKING SIDE hose
Panel SUCTION
GRILLE HO
OKING SI Press fit the
DE
Suction flexible hose
grille along the shape
45°
of the corner.
Suction grille
mounting angle
(5) Connect the opposite end of the flexible hose connected in (3)
onto the suction grille side.
* Rotate the flexible hose joint on the suction grille side
Panel according to the mounting direction of the suction grille as
shown in the illustration.
Suction grille Flexible hose
Flexible hose joint on joint on the
the suction grille side suction grille side
(2) As shown in the illustration, hook the fall prevention cords for
Flexible hose
the suction grille to the corner clasps (on 2 corners).
Note
Check that the clamps are engaged securely. Otherwise, a
dust collection failure may result.
Suction grille
(6) Push up the suction grille slowly first, and while pressing the
two knobs, finally fit the grille into the panel securely.
Fall prevention cord Panel
Knobs
Clasp
(2 points)
Bend the
Clasp
clasp inward.
Suction grille
10 3P257556-2B English
3P257556-2B
10
3P257556_2B_EM13A021A.indb 10 2015/04/14 9:37:35
BYCQ125BGW1EDUS391400B-F14
Note (4) Attach the decoration corner covers (i.e., the three covers) to
the panel.
The suction grille can catch the fall prevention cords while the
suction grille is closed.
Check that the fall prevention cords do not protrude from the
suction grille before closing the suction grille.
Suction grille
Must not protrude
The red lamp to inform the customer of the time of dust collection
will not be turned off.
Pin
3P257556-2B English 11
3P257556-2B
11
3P257556_2B_EM13A021A.indb 11 2015/04/14 9:37:37
BYCQ125BGW1EDUS391400B-F14
Make field settings according to the installation manual of the This remote controller is the BRC1E73 model.
remote controller. (Settings in bold cells are made before shipping.) Other remote controllers may vary in display.
FIRST SECOND CODE NO. 1.
Setting Mode CODE 2.
item No. NO. 01 02 03 04 Cool Set to
Press and hold
Display
Dust 10
83 F
Cancel button for
4 seconds or
(3) Display No display – – longer during
Collection (20) Return Setting backlight lit.
sign 1
Dust Standard Large
14
quantity (9) quantity of quantity of – – 3.
(24) Service Settings 3/3
settings dust dust
Filter Indicator OFF
On while in Possible to Off while in Test Filter Auto Clean
Panel
air-conditioning turn on while air-conditioning Brush/Filter Ind. OFF Press Menu/OK
indicator 14 Disable Filter Auto Clean button.
(4) operation and in filter operation and filter –
(green) (24)
filter cleaning cleaning cleaning operation.
on/off
operation. operation only. * Factory settings Setting
4.
11. Test Operation
Perform the test operation of the Self Cleaning decoration panel Cool Set to
after the test operation of the indoor unit is finished.
The test operation of the Self-Cleaning Decoration Panel is not 83 F
possible while the indoor unit is in operation.
AUTO CLN
FILTER
Return Setting
Note
Perform the test operation of the product after referring to “a. Test
items on completion of work”. Backlight for LCD
Press any button and the backlight will be lit for approximately
11-1 Check that the control box covers of the 30 seconds.
indoor unit, outdoor unit, and self-clean Perform the operation of buttons while the backlight is lit (except the
panel, respectively, are closed On/Off button).
Test items on test operation
11-2 Turn the indoor unit power on
Check
The panel will go into initialization operation after the power is Test items Remedy result
turned on.
Is the filter rotating?
Check the
Are the louvers fixed horizontally?
11-3 Conduct the test operation of the panel 2 connector
minutes after the power is turned on Is “ FILTER
AUTO CLN
” displayed on the screen of connections.
the remote controller?
Confirm the cleaning operation of the filter with the remote
controller. * The remote controller will display “AH” if the self-clean panel has
an error.
Test operation method with remote controller
1. Stop the operation of the panel if the panel is in air-conditioning Note
operation. • After the test operation of the product is finished, refer to “b. Test
2. Continue pressing the Cancel button at least 4 seconds while the items before delivery”.
backlight is lit. The service settings menu will appear. • In some models “ ” might appear instead of “ FILTER
AUTO CLN
”.
3. Select Test Filter Auto Clean from the service settings menu,
and press the Menu/OK button.
4. “ FILTER
AUTO CLN
” will appear on the basic screen.
The display will disappear when the test operation is finished.
The required test operation time is approximately 10 minutes (in
the case of setting the standard quantity of dust).
12 3P257556-2B English
3P257556-2B
12
3P257556_2B_EM13A021A.indb 12 2015/04/14 9:37:38
KKHAP55A160EDUS391400B-F14
Appendix 2
Installation of L-shape Extension Pipe
KKHAP55A160
1. Installation Manual......................................................................................1
A2
KKHAP55A160EDUS391400B-F14
1. Installation Manual
KKHAP55A160
3P367926-1
1
KAFP554A160EDUS391400B-F14
Appendix 3
Installation of Replacement Filter for Self
Cleaning Decoration Panel
KAFP554A160
1. Installation Manual......................................................................................1
A3
KAFP554A160EDUS391400B-F14
1. Installation Manual
KAFP554A160
1P367830-1A
1
KAFP554A160EDUS391400B-F14
1P367830-1A
2
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user’s manual carefully before using this product. The user’s manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any inquiries, please contact your local importer, distributor and/or retailer.
●Specifications, designs and other content appearing in this brochure are current as of June 2020 but subject to change without notice.