You are on page 1of 44

EDMT341534

FXMQ20-125A / FXMQ140P
Ceiling Mounted Duct Type

1. Specifications ......................................................................................154
2. Dimensions .........................................................................................158
3. Piping Diagrams..................................................................................164
4. Wiring Diagrams..................................................................................166
5. Electric Characteristics........................................................................168
6. Safety Devices Setting ........................................................................170
7. Capacity Tables ..................................................................................171
7.1 Cooling Capacity ..................................................................................171
7.2 Heating Capacity ..................................................................................171
8. Fan Performances...............................................................................172
9. Airflow Auto Adjustment Characteristics .............................................181
10.Sound Levels ......................................................................................189
11.Centre of Gravity .................................................................................194
12.Accessories.........................................................................................196 9
12.1 Optional Accessories (for Unit).............................................................196
12.2 Optional Accessories (for Controls)......................................................196

FXMQ20-125A / FXMQ140P 153


Specifications EDMT341534

1. Specifications
Ceiling mounted duct type
Model FXMQ20AVE FXMQ25AVE FXMQ32AVE FXMQ36AVE
Power supply 1 phase, 220V, 60Hz 1 phase, 220V, 60Hz 1 phase, 220V, 60Hz 1 phase, 220V, 60Hz
kcal/h 1,900 2,400 3,100 3,400
+1 +3 Cooling capacity Btu/h 7,500 9,600 12,300 13,600
kW 2.2 2.8 3.6 4.0
kcal/h 2,200 2,800 3,400 3,900
+2 +3 Heating capacity Btu/h 8,500 10,900 13,600 1,540
kW 2.5 3.2 4.0 4.5
Casing / Colour Galvanized steel plate Galvanized steel plate Galvanized steel plate Galvanized steel plate
Dimensions: (H×W×D) mm 300×550×700 300×550×700 300×550×700 300×700×700
Model — — — —
Type Sirocco fan Sirocco fan Sirocco fan Sirocco fan
Motor output ×
Number of units W 90×1 90×1 90×1 140×1

Fan m³/min 9/7.5/6.5 9/7.5/6.5 9.5/8/7 16/13/11


Airflow rate (HH/H/L)
cfm 318/265/229 318/265/229 335/282/247 565/459/388
External static
pressure Pa Standard 50 (30-100 +4) Standard 50 (30-100 +4) Standard 50 (30-100 +4) Standard 100 (30-160 +4)

Drive Direct drive Direct drive Direct drive Direct drive

Temperature control Microprocessor thermostat Microprocessor thermostat Microprocessor thermostat Microprocessor thermostat
for cooling and heating for cooling and heating for cooling and heating for cooling and heating
Air filter +5 +5 +5 +5
Liquid pipes mm I6.4 (Flare connection) I6.4 (Flare connection) I6.4 (Flare connection) I6.4 (Flare connection)
Gas pipes mm I12.7 (Flare connection) I12.7 (Flare connection) I12.7 (Flare connection) I12.7 (Flare connection)
Piping
connections VP25 VP25 VP25 VP25
Drain pipe mm
( External dia. 32
Internal dia. 25 ) ( External dia. 32
Internal dia. 25 ) ( External dia. 32
Internal dia. 25 ) ( External
Internal dia. 25 )
dia. 32

Mass kg 24 24 24 27
+6 Sound pressure level (HH/H/L) dB(A) 33/31/29 33/31/29 34/32/30 39/37/35
Fuse. Fuse. Fuse. Fuse.
Safety devices Fan driver overload Fan driver overload Fan driver overload Fan driver overload
protector. protector. protector. protector.
Refrigerant control Electronic expansion valve Electronic expansion valve Electronic expansion valve Electronic expansion valve
Operation and installation Operation and installation Operation and installation Operation and installation
manual. Clamp metal. Drain manual. Clamp metal. Drain manual. Clamp metal. Drain manual. Clamp metal. Drain
hose. Screws for duct hose. Screws for duct hose. Screws for duct hose. Screws for duct
flanges. Thermal insulation flanges. Thermal insulation flanges. Thermal insulation flanges. Thermal insulation
for tube. Sealing pads. for tube. Sealing pads. for tube. Sealing pads. for tube. Sealing pads.
Standard accessories
Clamps. Washer for fixing Clamps. Washer for fixing Clamps. Washer for fixing Clamps. Washer for fixing
plate. Washers. The resin plate. Washers. The resin plate. Washers. The resin plate. Washers. The resin
detent for wire. Screws. Air detent for wire. Screws. Air detent for wire. Screws. Air detent for wire. Screws. Air
discharge flange. Air suction discharge flange. Air suction discharge flange. Air suction discharge flange. Air suction
flange. flange. flange. flange.
Specification C: 3D084984B C: 3D084984B C: 3D084984B C: 3D084984B
Drawing No.
Sound level C: 4D085058 C: 4D085058 C: 4D085059 C: 4D085060

Notes:
+1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5 m, level difference: 0 m. Conversion formulae
+2. Indoor temp.: 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Equivalent piping length: 7.5 m, level difference: 0 m.
kcal/h=kW×860
+3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Btu/h=kW×3412
+4. External static pressure is changeable in 7 (FXMQ20/25/32AVE), 13 (FXMQ36/40AVE), 14 (FXMQ50/56/63/80/100/125AVE), cfm=m³/min×35.3
10 (FXMQ140PVE) stages within the ( ) range by remote controller. These values indicate the lowest and highest possible static pressures.
+5. Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity
method) 50% or more.
+6. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are
normally somewhat higher as a result of ambient conditions.
7. Refer to Electric Characteristics for the power input.

154 FXMQ20-125A / FXMQ140P


EDMT341534 Specifications

Ceiling mounted duct type


Model FXMQ40AVE FXMQ50AVE FXMQ56AVE FXMQ63AVE
Power supply 1 phase, 220V, 60Hz 1 phase, 220V, 60Hz 1 phase, 220V, 60Hz 1 phase, 220V, 60Hz
kcal/h 3,900 4,800 5,400 6,100
+1 +3 Cooling capacity Btu/h 1,540 19,100 2,150 24,200
kW 4.5 5.6 6.3 7.1
kcal/h 4,300 5,400 6,100 6,900
+2 +3 Heating capacity Btu/h 17,100 21,500 24,200 27,300
kW 5.0 6.3 7.1 8.0
Casing / Colour Galvanized steel plate Galvanized steel plate Galvanized steel plate Galvanized steel plate
Dimensions: (H×W×D) mm 300×700×700 300×1,000×700 300×1,000×700 300×1,000×700
Model — — — —
Type Sirocco fan Sirocco fan Sirocco fan Sirocco fan
Motor output ×
Number of units W 140×1 350×1 350×1 350×1

Fan m³/min 16/13/11 18/16.5/15 19.5/17.5/16 19.5/17.5/16


Airflow rate (HH/H/L)
cfm 565/459/388 635/582/530 688/618/565 688/618/565
External static
pressure Pa Standard 100 (30-160 +4) Standard 100 (50-200 +4) Standard 100 (50-200 +4) Standard 100 (50-200 +4)

Drive Direct drive Direct drive Direct drive Direct drive

Temperature control Microprocessor thermostat Microprocessor thermostat Microprocessor thermostat Microprocessor thermostat
for cooling and heating for cooling and heating for cooling and heating for cooling and heating
Air filter +5 +5 +5 +5
Liquid pipes mm I6.4 (Flare connection) I6.4 (Flare connection) I9.5 (Flare connection) I9.5 (Flare connection)
Gas pipes mm I12.7 (Flare connection) I12.7 (Flare connection) I15.9 (Flare connection) I15.9 (Flare connection)
Piping
connections VP25 VP25 VP25 VP25
Drain pipe mm
( External dia. 32
Internal dia. 25 ) ( External dia. 32
Internal dia. 25 ) ( External dia. 32
Internal dia. 25 ) ( External
Internal dia. 25 )
dia. 32

Mass kg 27 35 35 35
+6 Sound pressure level (HH/H/L) dB(A) 39/37/35 41/39/37 42/40/38 42/40/38 9
Fuse. Fuse. Fuse. Fuse.
Safety devices Fan driver overload Fan driver overload Fan driver overload Fan driver overload
protector. protector. protector. protector.
Refrigerant control Electronic expansion valve Electronic expansion valve Electronic expansion valve Electronic expansion valve
Operation and installation Operation and installation Operation and installation Operation and installation
manual. Clamp metal. Drain manual. Clamp metal. Drain manual. Clamp metal. Drain manual. Clamp metal. Drain
hose. Screws for duct hose. Screws for duct hose. Screws for duct hose. Screws for duct
flanges. Thermal insulation flanges. Thermal insulation flanges. Thermal insulation flanges. Thermal insulation
for tube. Sealing pads. for tube. Sealing pads. for tube. Sealing pads. for tube. Sealing pads.
Standard accessories
Clamps. Washer for fixing Clamps. Washer for fixing Clamps. Washer for fixing Clamps. Washer for fixing
plate. Washers. The resin plate. Washers. The resin plate. Washers. The resin plate. Washers. The resin
detent for wire. Screws. Air detent for wire. Screws. Air detent for wire. Screws. Air detent for wire. Screws. Air
discharge flange. Air suction discharge flange. Air suction discharge flange. Air suction discharge flange. Air suction
flange. flange. flange. flange.
Specification C: 3D084984B C: 3D084984B C: 3D084984B C: 3D084984B
Drawing No.
Sound level C: 4D085060 C: 4D085061 C: 4D085062 C: 4D085062

Notes:
+1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5 m, level difference: 0 m. Conversion formulae
+2. Indoor temp.: 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Equivalent piping length: 7.5 m, level difference: 0 m.
kcal/h=kW×860
+3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Btu/h=kW×3412
+4. External static pressure is changeable in 7 (FXMQ20/25/32AVE), 13 (FXMQ36/40AVE), 14 (FXMQ50/56/63/80/100/125AVE), cfm=m³/min×35.3
10 (FXMQ140PVE) stages within the ( ) range by remote controller. These values indicate the lowest and highest possible static pressures.
+5. Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity
method) 50% or more.
+6. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are
normally somewhat higher as a result of ambient conditions.
7. Refer to Electric Characteristics for the power input.

FXMQ20-125A / FXMQ140P 155


Specifications EDMT341534

Ceiling mounted duct type


Model FXMQ80AVE FXMQ100AVE FXMQ125AVE
Power supply 1 phase, 220V, 60Hz 1 phase, 220V, 60Hz 1 phase, 220V, 60Hz
kcal/h 7,700 9,600 12,000
+1 +3 Cooling capacity Btu/h 30,700 38,200 47,800
kW 9.0 11.2 14.0
kcal/h 9,000 10,800 13,800
+2 +3 Heating capacity Btu/h 34,100 42,700 54,600
kW 10.0 12.5 16.0
Casing / Colour Galvanized steel plate Galvanized steel plate Galvanized steel plate
Dimensions: (H×W×D) mm 300×1,000×700 300×1,400×700 300×1,400×700
Model — — —
Type Sirocco fan Sirocco fan Sirocco fan
Motor output ×
Number of units W 350×1 350×1 350×1

Fan m³/min 25/22.5/20 32/27/23 39/33/28


Airflow rate (HH/H/L)
cfm 883/794/706 1,130/953/812 1,377/1,165/988
External static
pressure Pa Standard 100 (50-200 +4) Standard 100 (50-200 +4) Standard 100 (50-200 +4)

Drive Direct drive Direct drive Direct drive

Temperature control Microprocessor thermostat for cooling Microprocessor thermostat for cooling Microprocessor thermostat for cooling
and heating and heating and heating
Air filter +5 +5 +5
Liquid pipes mm I9.5 (Flare connection) I9.5 (Flare connection) I9.5 (Flare connection)
Gas pipes mm I15.9 (Flare connection) I15.9 (Flare connection) I15.9 (Flare connection)
Piping
connections VP25 VP25 VP25
Drain pipe mm
( External dia. 32
Internal dia. 25 ) ( External dia. 32
Internal dia. 25 ) ( External
Internal dia. 25 )
dia. 32

Mass kg 35 45 45
+6 Sound pressure level (HH/H/L) dB(A) 43/41/39 43/41/39 44/42/40
Fuse. Fuse. Fuse.
Safety devices
Fan driver overload protector. Fan driver overload protector. Fan driver overload protector.
Refrigerant control Electronic expansion valve Electronic expansion valve Electronic expansion valve
Operation and installation manual. Operation and installation manual. Operation and installation manual.
Clamp metal. Drain hose. Screws for Clamp metal. Drain hose. Screws for Clamp metal. Drain hose. Screws for
duct flanges. Thermal insulation for duct flanges. Thermal insulation for duct flanges. Thermal insulation for
Standard accessories tube. Sealing pads. Clamps. Washer tube. Sealing pads. Clamps. Washer tube. Sealing pads. Clamps. Washer
for fixing plate. Washers. The resin for fixing plate. Washers. The resin for fixing plate. Washers. The resin
detent for wire. Screws. Air discharge detent for wire. Screws. Air discharge detent for wire. Screws. Air discharge
flange. Air suction flange. flange. Air suction flange. flange. Air suction flange.
Specification C: 3D084984B C: 3D084984B C: 3D084984B
Drawing No.
Sound level C: 4D085063 C: 4D085064 C: 4D085067

Notes:
+1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5 m, level difference: 0 m. Conversion formulae
+2. Indoor temp.: 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Equivalent piping length: 7.5 m, level difference: 0 m.
kcal/h=kW×860
+3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Btu/h=kW×3412
+4. External static pressure is changeable in 7 (FXMQ20/25/32AVE), 13 (FXMQ36/40AVE), 14 (FXMQ50/56/63/80/100/125AVE), cfm=m³/min×35.3
10 (FXMQ140PVE) stages within the ( ) range by remote controller. These values indicate the lowest and highest possible static pressures.
+5. Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity
method) 50% or more.
+6. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are
normally somewhat higher as a result of ambient conditions.
7. Refer to Electric Characteristics for the power input.

156 FXMQ20-125A / FXMQ140P


EDMT341534 Specifications

Ceiling mounted duct type


Model FXMQ140PVE
Power supply 1 phase, 220-240/220V, 50/60Hz
kcal/h 13,800
+1 +3 Cooling capacity Btu/h 54,600
kW 16.0
kcal/h 15,500
+2 +3 Heating capacity Btu/h 61,400
kW 18.0
+7 Cooling 60Hz kW 0.404
Power input Heating 60Hz kW 0.380
Casing / Colour Galvanized steel plate
Dimensions: (H×W×D) mm 300×1,400×700
Model —
Type Sirocco fan
Motor output ×
W 350×1
Number of units
m³/min 46/39/32
Fan
Airflow rate (HH/H/L) l/s 767/650/533
cfm 1,624/1,377/1,130
+4 External static
Pa Standard 100 (50-140 +4)
pressure
Drive Direct drive
Temperature control Microprocessor thermostat for cooling and heating
Air filter +5
Liquid pipes mm I9.5 (Flare connection)
Gas pipes mm I15.9 (Flare connection)
Piping
connections VP25
Drain pipe mm
( External
Internal dia. 25 )
dia. 32
9
Mass kg 47
+6 Sound pressure level (HH/H/L) dB(A) 46/45/43
Fuse.
Safety devices
Fan driver overload protector.
Refrigerant control Electronic expansion valve
Operation manual. Installation manual. Drain hose. Sealing pads. Clamps. Washers. Screws. Insulation for fitting. Clamp
Standard accessories
metal. Air discharge flange. Air suction flange.
Specification C: 3D060388E
Drawing No.
Sound level C: 4D063786

Notes:
+1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5 m, level difference: 0 m. Conversion formulae
+2. Indoor temp.: 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Equivalent piping length: 7.5 m, level difference: 0 m.
kcal/h=kW×860
+3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Btu/h=kW×3412
+4. External static pressure is changeable in 7 (FXMQ20/25/32AVE), 13 (FXMQ36/40AVE), 14 (FXMQ50/56/63/80/100/125AVE), cfm=m³/min×35.3
10 (FXMQ140PVE) stages within the ( ) range by remote controller. These values indicate the lowest and highest possible static pressures. l/s=m³/min×1000/60
+5. Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity
method) 50% or more.
+6. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are
normally somewhat higher as a result of ambient conditions.
+7. Power input values are based on conditions of rated external static pressure.
8. Refer to Electric Characteristics for the power input when the airflow rate is maximum at maximum external static pressure.

FXMQ20-125A / FXMQ140P 157


Dimensions EDMT341534

2. Dimensions
FXMQ20AVE / FXMQ25AVE / FXMQ32AVE
Unit (mm)

3D085069

158 FXMQ20-125A / FXMQ140P


EDMT341534 Dimensions

FXMQ36AVE / FXMQ40AVE
Unit (mm)

3D085072
9

FXMQ20-125A / FXMQ140P 159


Dimensions EDMT341534

FXMQ50AVE
Unit (mm)

3D085073

160 FXMQ20-125A / FXMQ140P


EDMT341534 Dimensions

FXMQ56AVE / FXMQ63AVE / FXMQ80AVE


Unit (mm)

3D085074
9

FXMQ20-125A / FXMQ140P 161


Dimensions EDMT341534

FXMQ100AVE / FXMQ125AVE
Unit (mm)

3D085075A

162 FXMQ20-125A / FXMQ140P


EDMT341534 Dimensions

FXMQ140PVE
Unit (mm)

3D060162H
9

FXMQ20-125A / FXMQ140P 163


Piping Diagrams EDMT341534

3. Piping Diagrams
FXMQ20AVE / FXMQ25AVE / FXMQ32AVE / FXMQ36AVE / FXMQ40AVE / FXMQ50AVE / FXMQ56AVE /
FXMQ63AVE / FXMQ80AVE / FXMQ100AVE / FXMQ125AVE

C: 4D077607C

164 FXMQ20-125A / FXMQ140P


EDMT341534 Piping Diagrams

FXMQ140PVE

C: 4D034245M

„ Refrigerant pipe connection port diameters


(mm)
Model Gas Liquid
FXMQ140PVE I15.9 I9.5

FXMQ20-125A / FXMQ140P 165


Wiring Diagrams EDMT341534

4. Wiring Diagrams
FXMQ20AVE / FXMQ25AVE / FXMQ32AVE / FXMQ36AVE / FXMQ40AVE / FXMQ50AVE / FXMQ56AVE /
FXMQ63AVE / FXMQ80AVE / FXMQ100AVE / FXMQ125AVE

3D084439A

166 FXMQ20-125A / FXMQ140P


EDMT341534 Wiring Diagrams

FXMQ140PVE

C: 3D058783F
9

FXMQ20-125A / FXMQ140P 167


Electric Characteristics EDMT341534

5. Electric Characteristics
FXMQ20AVE / FXMQ25AVE / FXMQ32AVE / FXMQ36AVE / FXMQ40AVE / FXMQ50AVE / FXMQ56AVE /
FXMQ63AVE / FXMQ80AVE / FXMQ100AVE / FXMQ125AVE

4D084942

168 FXMQ20-125A / FXMQ140P


EDMT341534 Electric Characteristics

FXMQ140PVE

C: 4D060439D

FXMQ20-125A / FXMQ140P 169


Safety Devices Setting EDMT341534

6. Safety Devices Setting

Model FXMQ20AVE FXMQ25AVE FXMQ32AVE FXMQ36AVE FXMQ40AVE FXMQ50AVE FXMQ56AVE FXMQ63AVE FXMQ80AVE FXMQ100AVE FXMQ125AVE FXMQ140PVE
Printed circuit board 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V
fuse 3.15A 3.15A 3.15A 3.15A 3.15A 3.15A 3.15A 3.15A 3.15A 3.15A 3.15A 3.15A
Printed circuit board 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 250V 250V 250V 250V 250V 250V
fuse (Fan driver) 6.3A 6.3A 6.3A 6.3A 6.3A 6.3A 6.3A
Drain pump thermal
°C 145 145 145 145 145 145 145 145 145 145 145 145
fuse
C: 4D085099
C: 3D034597M

170 FXMQ20-125A / FXMQ140P


EDMT341534 Capacity Tables

7. Capacity Tables
7.1 Cooling Capacity
Indoor air temp.
Capacity 14.0°CWB 16.0°CWB 18.0°CWB 19.0°CWB 20.0°CWB 22.0°CWB 24.0°CWB
Model
indication 20°CDB 23°CDB 26°CDB 27°CDB 28°CDB 30°CDB 32°CDB
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
FXMQ20AVE 20 1.5 1.4 1.8 1.6 2.1 1.8 2.2 1.8 2.2 1.8 2.3 1.7 2.3 1.7
FXMQ25AVE 25 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.1 2.8 2.1 2.9 2.0 3.0 2.0
FXMQ32AVE 32 2.4 1.9 2.9 2.2 3.4 2.5 3.6 2.6 3.6 2.6 3.7 2.5 3.8 2.4
FXMQ36AVE 36 2.7 2.5 3.2 2.9 3.7 3.2 4.0 3.3 4.0 3.2 4.1 3.1 4.2 3.1
FXMQ40AVE 40 3.0 2.7 3.6 3.1 4.2 3.5 4.5 3.5 4.5 3.5 4.7 3.3 4.8 3.3
FXMQ50AVE 50 3.8 3.3 4.5 3.8 5.2 4.2 5.6 4.3 5.7 4.2 5.8 4.1 5.9 4.0
FXMQ56AVE 56 4.3 3.6 5.1 4.2 5.9 4.7 6.3 4.8 6.4 4.7 6.5 4.4 6.7 4.5
FXMQ63AVE 63 4.8 3.9 5.7 4.5 6.6 5.1 7.1 5.2 7.2 5.1 7.4 4.8 7.5 4.8
FXMQ80AVE 80 6.1 4.9 7.2 5.7 8.4 6.4 9.0 6.6 9.1 6.5 9.3 6.3 9.5 6.1
FXMQ100AVE 100 7.6 6.2 9.0 7.2 10.5 8.1 11.2 8.3 11.3 8.1 11.6 7.9 11.9 7.7
FXMQ125AVE 125 9.5 7.7 11.3 8.8 13.1 9.9 14.0 10.2 14.2 10.1 14.5 9.8 14.9 9.6
FXMQ140PVE 140 10.8 9.0 12.9 10.4 15.0 11.7 16.0 12.0 16.2 11.9 16.6 11.5 17.0 11.3

TC: Total capacity: kW


SHC: Sensible heat capacity: kW
Notes: 1. These capacity tables are for use when selecting a VRV indoor unit. The actual capacity of the VRV system depends on factors such
as the selected model of outdoor units, outdoor air temperature and piping length. Please confirm that the corrected capacity of the
VRV system satisfies the required heat load.
2. shows rated conditions.

7.2 Heating Capacity 9


Indoor air temp.°CDB
Capacity
Model indication 16.0 18.0 20.0 21.0 22.0 24.0
kW kW kW kW kW kW
FXMQ20AVE 20 2.6 2.6 2.5 2.4 2.3 2.2
FXMQ25AVE 25 3.4 3.4 3.2 3.1 3.0 2.8
FXMQ32AVE 32 4.2 4.2 4.0 3.9 3.7 3.5
FXMQ36AVE 36 4.7 4.7 4.5 4.4 4.2 4.0
FXMQ40AVE 40 5.2 5.2 5.0 4.8 4.7 4.4
FXMQ50AVE 50 6.6 6.6 6.3 6.1 5.9 5.5
FXMQ56AVE 56 7.4 4.4 7.1 6.9 6.7 6.2
FXMQ63AVE 63 8.4 8.4 8.0 7.7 7.5 7.0
FXMQ80AVE 80 10.5 10.5 10.0 9.7 9.4 8.7
FXMQ100AVE 100 13.1 13.1 12.5 12.1 11.7 10.9
FXMQ125AVE 125 16.8 16.8 16.0 15.5 15.0 13.9
FXMQ140PVE 140 18.9 18.9 18.0 17.4 16.8 15.7

Notes: 1. These capacity tables are for use when selecting a VRV indoor unit. The actual capacity of the VRV system depends on factors such
as the selected model of outdoor units, outdoor air temperature and piping length. Please confirm that the corrected capacity of the
VRV system satisfies the required heat load.
2. shows rated conditions.

FXMQ20-125A / FXMQ140P 171


Fan Performances EDMT341534

8. Fan Performances
FXMQ20AVE / FXMQ25AVE

3D085082

172 FXMQ20-125A / FXMQ140P


EDMT341534 Fan Performances

FXMQ32AVE

3D085083
9

FXMQ20-125A / FXMQ140P 173


Fan Performances EDMT341534

FXMQ36AVE / FXMQ40AVE

3D085084

174 FXMQ20-125A / FXMQ140P


EDMT341534 Fan Performances

FXMQ50AVE

3D085085
9

FXMQ20-125A / FXMQ140P 175


Fan Performances EDMT341534

FXMQ56AVE / FXMQ63AVE

3D085086

176 FXMQ20-125A / FXMQ140P


EDMT341534 Fan Performances

FXMQ80AVE

3D085087
9

FXMQ20-125A / FXMQ140P 177


Fan Performances EDMT341534

FXMQ100AVE

3D085088

178 FXMQ20-125A / FXMQ140P


EDMT341534 Fan Performances

FXMQ125AVE

3D085089
9

FXMQ20-125A / FXMQ140P 179


Fan Performances EDMT341534

FXMQ140PVE

3D063787

180 FXMQ20-125A / FXMQ140P


EDMT341534 Airflow Auto Adjustment Characteristics

9. Airflow Auto Adjustment Characteristics


FXMQ20AVE / FXMQ25AVE

3D085090
9

FXMQ20-125A / FXMQ140P 181


Airflow Auto Adjustment Characteristics EDMT341534

FXMQ32AVE

3D085091

182 FXMQ20-125A / FXMQ140P


EDMT341534 Airflow Auto Adjustment Characteristics

FXMQ36AVE / FXMQ40AVE

3D085093
9

FXMQ20-125A / FXMQ140P 183


Airflow Auto Adjustment Characteristics EDMT341534

FXMQ50AVE

3D085094

184 FXMQ20-125A / FXMQ140P


EDMT341534 Airflow Auto Adjustment Characteristics

FXMQ56AVE / FXMQ63AVE

3D085095
9

FXMQ20-125A / FXMQ140P 185


Airflow Auto Adjustment Characteristics EDMT341534

FXMQ80AVE

3D085096

186 FXMQ20-125A / FXMQ140P


EDMT341534 Airflow Auto Adjustment Characteristics

FXMQ100AVE

3D085097
9

FXMQ20-125A / FXMQ140P 187


Airflow Auto Adjustment Characteristics EDMT341534

FXMQ125AVE

3D085098

188 FXMQ20-125A / FXMQ140P


EDMT341534 Sound Levels

10. Sound Levels


FXMQ20AVE / FXMQ25AVE

4D085058
9

FXMQ32AVE

4D085059

FXMQ20-125A / FXMQ140P 189


Sound Levels EDMT341534

FXMQ36AVE / FXMQ40AVE

4D085060
FXMQ50AVE

4D085061

190 FXMQ20-125A / FXMQ140P


EDMT341534 Sound Levels

FXMQ56AVE / FXMQ63AVE

4D085062
9

FXMQ80AVE

4D085063

FXMQ20-125A / FXMQ140P 191


Sound Levels EDMT341534

FXMQ100AVE

4D085064
FXMQ125AVE

4D085067

192 FXMQ20-125A / FXMQ140P


EDMT341534 Sound Levels

FXMQ140PVE

4D063786
9

FXMQ20-125A / FXMQ140P 193


Centre of Gravity EDMT341534

11. Centre of Gravity


FXMQ20AVE / FXMQ25AVE / FXMQ32AVE / FXMQ36AVE / FXMQ40AVE / FXMQ50AVE / FXMQ56AVE /
FXMQ63AVE / FXMQ80AVE / FXMQ100AVE / FXMQ125AVE
Unit (mm)

C: 4D085081

194 FXMQ20-125A / FXMQ140P


EDMT341534 Centre of Gravity

FXMQ140PVE
Unit (mm)

C: 4D060438C

FXMQ20-125A / FXMQ140P 195


Accessories EDMT341534

12. Accessories
12.1 Optional Accessories (for Unit)
Model
Item
FXMQ20AVE FXMQ25AVE FXMQ32AVE FXMQ36AVE FXMQ40AVE FXMQ50AVE FXMQ56AVE FXMQ63AVE FXMQ80AVE FXMQ100AVE FXMQ125AVE FXMQ140PVE
High 65% KAF372AA36 KAF372AA56 KAF372AA80 KAF372AA160
efficiency filter 90% KAF373AA36 KAF373AA56 KAF373AA80 KAF373AA160
Filter chamber KDDF37AA36 KDDF37AA56 KDDF37AA80 KDDF37AA160
Long life replacement
filter KAF371AA36 KAF371AA56 KAF371AA80 KAF371AA160

Long life filter chamber KAF375AA36 KAF375AA56 KAF375AA80 KAF375AA160


kit
White KTBJ25K36W KTBJ25K56W KTBJ25K80W KTBJ25K160W
Fresh
Service panel white KTBJ25K36F KTBJ25K56F KTBJ25K80F KTBJ25K160F

Brown KTBJ25K36T KTBJ25K56T KTBJ25K80T KTBJ25K160T


Air discharge adaptor KDAJ25K36A KDAJ25K56A KDAJ25K71A KDAJ25K140A
C: 4D084946A
C: 3D060443D

12.2 Optional Accessories (for Controls)


Refer to page 834.

196 FXMQ20-125A / FXMQ140P