Professional Documents
Culture Documents
1
Content
Compact four-way cassette units .................................. 4
2
Compact four-way cassette indoor units with DC fan motor
3
Compact four-way cassette indoor units with DC fan motor
Features ................................................................................ 5
Specifications ...................................................................... 6
Dimensions ........................................................................... 9
Capacity Tables.................................................................. 13
Accessories ........................................................................ 20
4
Compact four-way cassette indoor units with DC fan motor
1. Features
1.1 Low operation noise, quiet design for user comfort
Streamline plate ensures quietness
Creates natural and comfortable environment
570mm
260mm
1.6 Optimal design, smaller Control Box, Space saving and convenient for wiring
Using fire resistance galvanized steel for E-box material. Metal box makes the control part more stable
and prevents damaging
1.7 Drain up pump with 500mm lift fitted as standard, max. up to 600mm head which can be
customized.
5
Compact four-way cassette indoor units with DC fan motor
1.8 Adopting DC fan motor.
1.8.1 Efficiency can be up to 90%. Contrast with the AC fan motor, the power consumption of DC fan motor
can reduce up to 30%.
1.8.2 The motor adopts fully enclosed structure design. The motor bearing can operate 80,000 hours
continuously and easy for maintenance.
1.8.3 Thanks to the DC fan motor, this wall-mounted indoor unit can meet the latest CE certification
requirements.
6
Compact four-way cassette indoor units with DC fan motor
2. Specifications
Model SDV4-22CAF SDV4-28CAF
Power supply V-ph-Hz 220-240V~1Ph~50/60Hz
Capacity kW 2.2 2.8
Cooling Input W 15 16
Rated current A 0.26 0.26
Capacity kW 2.4 3.2
Heating Input W 13 13
Rated current A 0.26 0.26
Model WZDK37-38G WZDK37-38G
7
Compact four-way cassette indoor units with DC fan motor
Model SDV4-36CAF SDV4-45CAF
Capacity kW 4 5
Heating Input W 18 18
Rated current A 0.28 0.28
Model WZDK37-38G WZDK37-38G
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 27°C DB, 19°C WB, and outdoor
temperature: 35°C DB, equivalent ref. piping: 8m (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB, outdoor temperature: 7°C
DB, 6°C WB, and equivalent ref. piping: 8m horizontal)
8
Compact four-way cassette indoor units with DC fan motor
3. Dimensions
Unit: mm
9
Compact four-way cassette indoor units with DC fan motor
4. Service Spaces
There is enough room for installation and maintenance.
The ceiling is horizontal, and its structure can endure the weight of the indoor unit.
The outlet and the inlet are not impeded, and the influence of external air is the least.
The air flow can reach throughout the room.
The connecting pipe and drainpipe could be extracted out easily.
There is no direct radiation from heaters.
A≥280
>2300
Unit:mm
Keep more than 2.3m distance between the panel and ground of the room.
10
Compact four-way cassette indoor units with DC fan motor
5. Piping Diagrams (EXV beside)
motor
fan
T2B flare nut
T1 gas side
T2
liquid side
EXV
11
Compact four-way cassette indoor units with DC fan motor
6. Wiring Diagrams
SDV4-22CAF, SDV4-28CAF, SDV4-36CAF, SDV4-45CAF
12
Compact four-way cassette indoor units with DC fan motor
Function setting indication
13
Compact four-way cassette indoor units with DC fan motor
7. Capacity Tables
7.1 Cooling
TC: total capacity SC: sensible capacity WB: wet-bulb temperature DB: dry-bulb temperature
Indoor temperature (°C WB/DB)
Indoor Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32
Unit size temperature
(kW) (°C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.9 1.7
12 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.6
14 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.6
16 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.6
18 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.6
20 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.5
21 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.5
23 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.7 1.5
25 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.6 1.5
2.2 27 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.6 1.5
29 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.5 2.5 1.5
31 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.5 2.5 1.5
33 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.5 2.4 1.5
35 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.3 1.5 2.4 1.5
37 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.3 1.5 2.3 1.5
39 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.3 1.5
42 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.3 1.5
44 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.3 1.5
46 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.3 1.5
10 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.7 2.0
12 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.6 2.0
14 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.6 2.0
16 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.5 1.9
18 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.5 1.9
20 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.4 1.9
21 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.4 1.9
23 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.4 1.9
25 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.2 1.9 3.3 1.9
2.8 27 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.2 1.9 3.3 1.9
29 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.1 1.8 3.2 1.8
31 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.1 1.8 3.2 1.7
33 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.1 1.8 3.1 1.7
35 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 2.9 1.9 3.0 1.8 3.1 1.7
37 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 2.9 1.9 3.0 1.8 3.0 1.7
39 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 2.9 1.9 3.0 1.9 3.0 1.7
42 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 2.9 1.9 3.0 1.9 3.0 1.7
44 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 2.9 1.9 3.0 1.9 3.0 1.7
46 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 2.9 1.9 3.0 1.9 3.0 1.7
14
Compact four-way cassette indoor units with DC fan motor
Indoor temperature (°C WB/DB)
Indoor Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32
Unit size temperature
(kW) (°C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.7 2.5
12 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.7 2.5
14 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.6 2.4
16 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.5 2.4
18 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.5 2.4
20 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.4 2.3
21 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.4 2.3
23 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.1 2.3 4.3 2.2
25 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.1 2.3 4.2 2.2
3.6 27 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.0 2.2 4.2 2.2
29 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.0 2.2 4.1 2.2
31 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.2 2.6 4.1 2.2
33 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.2 2.6 3.9 2.1
35 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.2 2.6 3.9 2.1
37 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.7 2.4 3.8 2.3 3.9 2.1
39 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.7 2.4 3.8 2.3 3.8 2.1
42 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.7 2.4 3.8 2.3 3.8 2.1
44 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.7 2.4 3.8 2.3 3.8 2.1
46 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.7 2.4 3.8 2.3 3.8 2.1
10 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.9 3.0
12 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.9 3.0
14 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.8 3.0
16 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.6 2.9
18 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.7 3.0
20 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.7 3.0
21 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.6 3.0
23 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.5 3.0
25 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.2 3.0 5.4 2.9
4.5 27 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.1 3.0 5.2 2.8
29 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.1 2.9 5.2 2.8
31 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.0 2.9 5.1 2.7
33 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 4.9 2.8 5.1 2.7
35 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 4.8 2.8 5.0 2.7
37 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 4.8 2.9 4.9 2.6
39 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.6 2.8 4.7 2.8 4.8 2.6
42 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.6 2.8 4.7 2.8 4.8 2.6
44 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.6 2.8 4.7 2.8 4.8 2.6
46 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.6 2.8 4.7 3.1 4.8 2.6
15
Compact four-way cassette indoor units with DC fan motor
7.2 Heating
TC: total capacity WB: wet-bulb temperature DB: dry-bulb temperature
Indoor temperature (°C DB)
Outdoor temperature
Indoor Unit 16 18 20 21 22 24
(°C)
size (kW) TC TC TC TC TC TC
WB DB kW kW kW kW kW kW
-20 -19,8 1.34 1.34 1.34 1.34 1.34 1.34
-19 -18,8 1.44 1.44 1.44 1.44 1.44 1.44
-17 -16,7 1.51 1.51 1.51 1.51 1.51 1.51
-15 -14,7 1.56 1.56 1.56 1.56 1.56 1.56
-13 -12,6 1.66 1.66 1.66 1.66 1.66 1.66
-11 -10,5 1.68 1.70 1.70 1.70 1.70 1.70
-10 -9,5 1.75 1.75 1.75 1.75 1.75 1.75
-9,1 -8,5 1.80 1.80 1.80 1.80 1.80 1.80
-7,6 -7 1.82 1.82 1.82 1.82 1.82 1.82
2.2 -5,6 -5 1.90 1.90 1.90 1.90 1.90 1.90
-3,7 -3 1.99 1.99 1.99 1.99 1.99 1.99
-0,7 0 2.14 2.14 2.14 2.14 2.14 2.02
2,2 3 2.26 2.26 2.26 2.26 2.21 2.02
4,3 5 2.33 2.33 2.33 2.33 2.21 2.02
6,0 7 2.40 2.40 2.40 2.33 2.21 2.02
7,9 9 2.47 2.47 2.40 2.33 2.21 2.02
9,8 11 2.54 2.54 2.40 2.33 2.21 2.02
11,8 13 2.64 2.59 2.40 2.33 2.21 2.02
13,7 15 2.71 2.59 2.40 2.33 2.21 2.02
-20 -19,8 1.79 1.79 1.79 1.79 1.79 1.79
-19 -18,8 1.92 1.92 1.92 1.92 1.92 1.92
-17 -16,7 2.02 2.02 2.02 2.02 2.02 2.02
-15 -14,7 2.02 2.02 2.02 2.02 2.02 2.02
-13 -12,6 2.14 2.14 2.14 2.14 2.14 2.14
-11 -10,5 2.24 2.24 2.24 2.24 2.24 2.24
-10 -9,5 2.34 2.34 2.34 2.34 2.34 2.34
-9,1 -8,5 2.40 2.40 2.40 2.40 2.40 2.40
-7,6 -7 2.43 2.43 2.43 2.43 2.43 2.43
2.8 -5,6 -5 2.53 2.53 2.53 2.53 2.53 2.53
-3,7 -3 2.66 2.66 2.66 2.66 2.66 2.66
-0,7 0 2.85 2.85 2.85 2.85 2.85 2.69
2,2 3 3.01 3.01 3.01 3.01 2.94 2.69
4,3 5 3.10 3.10 3.10 3.10 2.94 2.69
6,0 7 3.20 3.20 3.20 3.10 2.94 2.69
7,9 9 3.30 3.30 3.20 3.10 2.94 2.69
9,8 11 3.39 3.39 3.20 3.10 2.94 2.69
11,8 13 3.52 3.46 3.20 3.10 2.94 2.69
13,7 15 3.62 3.46 3.20 3.10 2.94 2.69
16
Compact four-way cassette indoor units with DC fan motor
Indoor temperature (°C DB)
Outdoor temperature
Indoor Unit 16 18 20 21 22 24
(°C)
size (kW) TC TC TC TC TC TC
WB DB kW kW kW kW kW kW
-20 -19,8 2.24 2.24 2.24 2.24 2.24 2.24
-19 -18,8 2.40 2.40 2.40 2.40 2.40 2.40
-17 -16,7 2.52 2.52 2.52 2.52 2.52 2.52
-15 -14,7 2.60 2.60 2.60 2.60 2.60 2.60
-13 -12,6 2.68 2.68 2.68 2.68 2.68 2.68
-11 -10,5 2.80 2.80 2.80 2.80 2.80 2.80
-10 -9,5 2.92 2.92 2.92 2.92 2.92 2.92
-9,1 -8,5 3.00 3.00 3.00 3.00 3.00 3.00
-7,6 -7 3.04 3.04 3.04 3.04 3.04 3.04
3.6 -5,6 -5 3.16 3.16 3.16 3.16 3.16 3.16
-3,7 -3 3.32 3.32 3.32 3.32 3.32 3.32
-0,7 0 3.56 3.56 3.56 3.56 3.56 3.36
2,2 3 3.76 3.76 3.76 3.76 3.68 3.36
4,3 5 3.88 3.88 3.88 3.88 3.68 3.36
6,0 7 4.00 4.00 4.00 3.88 3.68 3.36
7,9 9 4.12 4.12 4.00 3.88 3.68 3.36
9,8 11 4.24 4.24 4.00 3.88 3.68 3.36
11,8 13 4.40 4.32 4.00 3.88 3.68 3.36
13,7 15 4.52 4.32 4.00 3.88 3.68 3.36
-20 -19,8 2.80 2.80 2.80 2.80 2.80 2.80
-19 -18,8 3.00 3.00 3.00 3.00 3.00 3.00
-17 -16,7 3.15 3.15 3.15 3.15 3.15 3.15
-15 -14,7 3.25 3.25 3.25 3.25 3.25 3.25
-13 -12,6 3.35 3.35 3.35 3.35 3.35 3.35
-11 -10,5 3.50 3.50 3.50 3.50 3.50 3.50
-10 -9,5 3.65 3.65 3.65 3.65 3.65 3.65
-9,1 -8,5 3.75 3.75 3.75 3.75 3.75 3.75
-7,6 -7 3.80 3.80 3.80 3.80 3.80 3.80
4.5 -5,6 -5 3.95 3.95 3.95 3.95 3.95 3.95
-3,7 -3 4.15 4.15 4.15 4.15 4.15 4.15
-0,7 0 4.45 4.45 4.45 4.45 4.45 4.20
2,2 3 4.70 4.70 4.70 4.70 4.60 4.20
4,3 5 4.85 4.85 4.85 4.85 4.60 4.20
6,0 7 5.00 5.00 5.00 4.85 4.60 4.20
7,9 9 5.15 5.15 5.00 4.85 4.60 4.20
9,8 11 5.30 5.30 5.00 4.85 4.60 4.20
11,8 13 5.50 5.40 5.00 4.85 4.60 4.20
13,7 15 5.65 5.40 5.00 4.85 4.60 4.20
17
Compact four-way cassette indoor units with DC fan motor
8. Electrical Characteristics
Indoor Unit Power Supply IFM
Model
Hz Voltage Min. Max. MCA MFA kW FLA
SDV4-22CAF 50/60 220-240 198 254 0.28 15 0.037 0.22
SDV4-28CAF 50/60 220-240 198 254 0.28 15 0.037 0.22
SDV4-36CAF 50/60 220-240 198 254 0.33 15 0.037 0.26
SDV4-45CAF 50/60 220-240 198 254 0.33 15 0.037 0.26
Remark:
MCA: Min. Current Amps. (A)
MFA: Max. Fuse Amps. (A)
kW: Fan Motor Rated Output (kW)
FLA: Full Load Amps. (A)
IFM: Indoor Fan Motor
18
Compact four-way cassette indoor units with DC fan motor
9. Sound Levels
9.1 Test condition
1.4m
Note:
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Semi-anechoic chamber conversion value, measured at a point which is 1.4m under the unit.
19
Compact four-way cassette indoor units with DC fan motor
10. Accessories
10.1 Standard accessories
Name Quantity Outline
1. Nut M10 10
2. Washer Φ10 10
4. Bolt M6 / /
5. Soundproof / insulation sheath 1
9. Tightening band 5
11. Frame 1
20
Four-way cassette indoor units with DC fan motor
21
Four way cassette indoor units with DC fan motor
Features ................................................................. 23
Specifications ........................................................ 25
Dimensions ............................................................ 26
Accessories ........................................................... 42
22
Four-way cassette indoor units with DC fan motor
1. Features
External appearance
Regardless of difference in capacity, all indoor units feature the same panel size and design, in
consideration or harmonized interior decoration.
Four way uniform airflow
Four air discharge ports provide strong air flow circulation to cool or heat every corner of a room and
evenly distribute temperature. High airflow mode can maximize the conditioning effect in rooms that are
over 3m high.
Ultra-thin machine body to easy installation and maintenance
2.8kW~8.0kW models in 230mm height and 9.0kW~14kW models in 300mm height which can be installed
in narrow false ceilings.
Higher efficiency
Adopting DC fan motor, efficiency can be up to 90%. Contrast with the AC fan motor, the power
consumption of DC fan motor can reduce up to 30%.
Power Inpu t:W DC and AC motors power contrast
200
DC moto r
150
AC moto r
100
50
Air Flow:CFM
0
DC fan motor
The motor adopts fully enclosed structure design. The motor bearing can operate 80,000 hours
continuously and easy for maintenance.
23
Four way cassette indoor units with DC fan motor
b) Duct connection is possible.
24
Four-way cassette indoor units with DC fan motor
2. Specifications
Model SDV4-56CAF SDV4-71CAF SDV4-80CAF
Power supply 220-240V~50/60Hz
Capacity kW 5.6 7.1 8.0
Cooling
Power input W 31 46 48
Capacity kW 6.3 8.0 9.0
Heating
Power input W 31 46 48
Model WZDK80-38G
Type DC motor
Brand Shibaura
Indoor fan motor Insulation class E
Safe class IP20
Input W 44 55 55
Output W 35 44 44
Material Plastic
Type Centrifugal fan
Indoor fan
Diameter mm 476
Height mm 137
Number of rows 2
Tube pitch(a)×
mm 21×13.37
row pitch(b)
Fin spacing mm 1.5
Indoor coil Fin type Hydrophilic aluminium
Tube size mm Ф7
Tube type Innergroove tube
Coil length×height mm 1961×168
Number of circuits 8
3
Indoor air flow (H/M/L) m /h 1029/857/704 1200/996/748 1264/1055/811
25
Four way cassette indoor units with DC fan motor
Model SDV4-90CAF SDV4-100CAF SDV4-112CAF SDV4-140CAF
Power supply 220-240V~50/60Hz
Capacity kW 9.0 10.0 11.2 14.0
Cooling
Power input W 75 75 75 94
Capacity kW 10.0 11.1 12.5 15.0
Heating
Power input W 75 75 75 94
Model WZDK90-38G
Type DC motor
Brand Shibaura
Indoor fan motor Insulation class E
Safe class IP20
Input W 110 110 110 120
Output W 88 88 88 90
Material Plastic
Type Centrifugal fan
Indoor fan
Diameter mm 476
Height mm 170
Number of rows 2 2 2 3
Tube pitch(a)×
mm 21×13.37
row pitch(b)
Fin spacing mm 1.5
Indoor coil Fin type Hydrophilic aluminium
Tube size mm Ф7
Tube type Innergroove tube
Coil length×height mm 1955×252
Number of circuits 8 12
3 1596/1239/ 1596/1239/ 1596/1239/ 1727/1426/
Indoor air flow (H/M/L) m /h
1034 1034 1034 1224
Sound pressure level (H/M/L) dB(A) 47/41/36 47/41/36 47/41/36 50/45/35
Net dimension
mm 904×300×840
(W×H×D)
Indoor unit body Packing size
mm 955×330×955
(W×H×D)
Net/Gross weight kg 27.4/33.2 27.4/33.2 27.4/33.2 30/35.8
Net dimension
mm 950×54.5×950
(W×H×D)
Indoor unit panel Packing size
mm 1035×90×1035
(W×H×D)
Net/Gross weight kg 5/8
Refrigerant type R410A
Throttle type EXV
Design pressure MPa 4.4/2.6
(H/L) Liquid pipe mm Φ9.53
Pipe connections Gas pipe mm Φ15.9
Drain pipe mm Φ32
Controller Wireless remote controller (RM05)
Notes:
Capacities are based on the following conditions:
Cooling: Indoor temperature 27°C DB / 19°C WB; Outdoor temperature 35°C DB / 24°C WB.
Heating: Indoor temperature 20°C DB / 15°C WB; Outdoor temperature 7°C DB / 6°C WB.
Piping length: Interconnecting piping length is 8m, level difference is 0m.
Sound values are measured in a semi-anechoic room, at a position 1.4m downward from the unit center.
26
Four-way cassette indoor units with DC fan motor
3. Dimensions
Unit:mm
A B C D
Indoor unit model
mm mm mm mm
5.6-8.0kW 230 170 Ф9.53 Ф15.9
9.0-14.0kW 300 190 Ф9.53 Ф15.9
27
Four way cassette indoor units with DC fan motor
4. Service spaces
1) There is enough room for installation and maintenance.
2) The ceiling is horizontal, and its structure can endure the weight of the indoor unit.
3) The outlet and the inlet are not impeded, and the influence of external air is the least.
4) The air flow can reach throughout the room.
5) The connecting pipe and drainpipe could be extracted out easily.
6) There is no direct radiation from heaters.
Unit: mm
A H
Model
mm mm
≤8kW 230 260
≥9kW 300 330
28
Four-way cassette indoor units with DC fan motor
5. Piping diagrams
motor
fan
T2B flare nut
T1 gas side
T2
liquid side
EXV
29
Four way cassette indoor units with DC fan motor
6. Wiring diagrams
Models: 5.6-14kW
30
Four-way cassette indoor units with DC fan motor
7. Capacity tables
7.1 Cooling capacity tables
TC: Total Cooling Capacity SC: Sensible Cooling Capacity
Indoor air temp. (°C WB/DB)
Unit Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32
size air temp.
(kW) (°C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 7.3 3.5
12 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 7.2 3.5
14 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 7.1 3.5
16 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 7.0 3.4
18 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 6.8 3.4
20 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 6.7 3.3
21 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 6.6 3.3
23 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 6.6 3.3
25 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 6.5 3.2
5.6 27 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.4 3.5 6.4 3.2
29 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.3 3.5 6.4 3.3
31 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.2 3.4 6.2 3.2
33 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.2 3.4 6.2 3.2
35 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.0 3.3 6.0 3.1
37 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 5.9 3.2 6.0 3.1
39 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.7 3.4 5.8 3.2 6.0 3.1
42 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.7 3.4 5.8 3.2 6.0 3.1
44 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.7 3.4 5.8 3.2 6.0 3.1
46 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.7 3.7 5.8 3.2 6.0 3.1
10 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 9.2 4.6
12 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 9.1 4.5
14 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 9.0 4.5
16 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 8.9 4.4
18 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 8.7 4.3
20 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 8.5 4.2
21 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 8.4 4.2
23 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 8.3 4.1
25 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 8.2 4.1
7.1 27 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.1 4.3 8.2 4.1
29 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.5 8.0 4.3 8.1 4.1
31 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.5 7.9 4.3 7.8 4.0
33 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.5 7.8 4.2 7.8 4.0
35 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.5 7.6 4.1 7.7 4.0
37 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.4 4.4 7.5 4.1 7.6 4.0
39 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.2 4.3 7.4 4.1 7.6 4.0
42 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.2 4.3 7.4 4.1 7.6 4.0
44 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.2 4.3 7.4 4.1 7.6 4.0
46 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.2 4.3 7.4 4.1 7.6 4.0
31
Four way cassette indoor units with DC fan motor
Indoor air temp. (°C WB/DB)
Unit Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32
size air temp.
(kW) (°C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 10.4 5.6
12 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 10.2 5.5
14 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 10.2 5.5
16 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 10.0 5.4
18 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 9.8 5.3
20 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 9.6 5.2
21 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 9.4 5.1
23 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 9.4 5.1
25 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 9.3 5.1
8.0 27 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.1 5.3 9.2 5.1
29 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.5 9.0 5.3 9.1 5.0
31 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.5 8.9 5.2 8.8 4.9
33 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.5 8.8 5.2 8.8 4.9
35 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.5 8.6 5.1 8.6 4.8
37 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.3 5.4 8.4 5.0 8.6 4.8
39 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.1 5.3 8.3 5.0 8.6 4.8
42 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.1 5.3 8.3 5.0 8.6 4.8
44 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.1 5.3 8.3 5.0 8.6 4.8
46 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.1 5.3 8.3 5.0 8.6 4.8
10 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 11.7 6.0
12 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 11.5 5.9
14 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 11.4 5.9
16 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 11.3 5.8
18 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 11.0 5.8
20 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 10.8 5.7
21 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 10.6 5.6
23 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 10.5 5.5
25 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 10.4 5.5
9.0 27 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.3 5.9 10.4 5.4
29 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.1 5.7 10.3 5.4
31 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.0 5.7 9.9 5.3
33 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 9.9 5.6 9.9 5.3
35 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.5 6.0 9.6 5.5 9.7 5.3
37 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.3 5.8 9.5 5.4 9.6 5.3
39 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.2 5.7 9.4 5.3 9.6 5.3
42 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.2 5.7 9.4 5.3 9.6 5.3
44 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.2 5.7 9.4 5.3 9.6 5.3
46 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.2 5.7 9.4 5.3 9.6 5.3
32
Four-way cassette indoor units with DC fan motor
Indoor air temp. (°C WB/DB)
Unit Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32
size air temp.
(kW) (°C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 13.0 7.3
12 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 12.8 7.2
14 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 12.7 7.1
16 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 12.5 7.0
18 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 12.2 6.8
20 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 12.0 6.7
21 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 11.8 6.6
23 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.7 7.3 11.7 6.6
25 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.6 7.2 11.6 6.5
10.0 27 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.5 7.1 11.5 6.6
29 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.4 7.1 11.4 6.5
31 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.3 7.0 11.0 6.3
33 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.2 6.9 11.0 6.3
35 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.5 6.9 10.8 6.7 10.8 6.3
37 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.4 6.9 10.8 6.7 10.7 6.2
39 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.2 6.7 10.4 6.6 10.7 6.3
42 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.2 6.7 10.4 6.6 10.7 6.3
44 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.2 6.7 10.4 6.6 10.7 6.3
46 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.2 6.7 10.4 6.6 10.7 6.3
10 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 15.5 8.2
12 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 14.4 7.7
14 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 14.2 7.6
16 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 14.1 7.5
18 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 14.0 7.5
20 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 13.9 7.4
21 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 13.8 7.4
23 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.1 7.5 13.7 7.3
25 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.0 7.4 13.6 7.2
11.2 27 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 12.9 7.3 13.4 7.2
29 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 12.8 7.3 13.3 7.2
31 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 12.7 7.2 12.8 6.9
33 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 12.5 7.2 12.5 6.8
35 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.8 7.4 12.4 7.1 12.3 6.7
37 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.6 7.3 12.3 7.0 12.1 6.6
39 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.4 7.1 12.2 7.0 11.9 6.6
42 7.7 6.0 9.1 6.6 10.4 7.2 11.2 7.3 11.4 7.1 11.6 6.6 12.0 6.6
44 7.7 6.0 9.1 6.6 10.4 7.2 11.2 7.3 11.4 7.1 11.6 6.6 12.0 6.6
46 7.7 6.0 9.1 6.6 10.4 7.2 11.2 7.3 11.4 7.1 11.6 6.6 12.0 6.6
33
Four way cassette indoor units with DC fan motor
Indoor air temp. (°C WB/DB)
Unit Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32
size air temp.
(kW) (°C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 18.2 9.4
12 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 17.9 9.2
14 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 17.8 9.2
16 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 17.5 9.0
18 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 17.1 8.8
20 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 16.8 8.7
21 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 16.5 8.5
23 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.4 9.3 16.4 8.4
25 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.2 9.3 16.2 8.4
14.0 27 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.1 9.2 16.1 8.4
29 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.0 9.1 16.0 8.4
31 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 15.8 9.0 15.4 8.1
33 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 15.7 8.9 15.4 8.1
35 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.7 8.9 15.1 8.6 15.1 8.1
37 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.6 8.8 15.1 8.6 15.0 8.0
39 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.3 8.7 14.6 8.4 15.0 8.1
42 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.3 8.7 14.6 8.4 15.0 8.1
44 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.3 8.7 14.6 8.4 15.0 8.1
46 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.3 8.7 14.6 8.4 15.0 7.2
34
Four-way cassette indoor units with DC fan motor
35
Four way cassette indoor units with DC fan motor
Indoor air temp. (°C DB)
Outdoor
Unit size 16 18 20 21 22 24
air temp. (°C)
(kW) TC TC TC TC TC TC
WB DB kW kW kW kW kW kW
-20.0 -19.8 5.04 5.04 5.04 5.04 5.04 5.04
-19.0 -18.8 5.40 5.40 5.40 5.40 5.40 5.40
-17.0 -16.7 5.67 5.67 5.67 5.67 5.67 5.67
-15.0 -14.7 5.85 5.85 5.85 5.85 5.85 5.85
-13.0 -12.6 6.21 6.21 6.21 6.21 6.21 6.21
-11.0 -10.5 6.30 6.39 6.39 6.39 6.39 6.39
-10.0 -9.5 6.57 6.57 6.57 6.57 6.57 6.57
-9.1 -8.5 6.75 6.75 6.75 6.75 6.75 6.75
-7.6 -7.0 6.84 6.84 6.84 6.84 6.84 6.84
8.0 -5.6 -5.0 7.11 7.11 7.11 7.11 7.11 7.11
-3.7 -3.0 7.47 7.47 7.47 7.47 7.47 7.47
-0.7 0.0 8.01 8.01 8.01 8.01 8.01 7.56
2.2 3.0 8.46 8.46 8.46 8.46 8.28 7.56
4.1 5.0 8.73 8.73 8.73 8.73 8.28 7.56
6.0 7.0 9.00 9.00 9.00 8.73 8.28 7.56
7.9 9.0 9.27 9.27 9.00 8.73 8.28 7.56
9.8 11.0 9.54 9.54 9.00 8.73 8.28 7.56
11.8 13.0 9.90 9.72 9.00 8.73 8.28 7.56
13.7 15.0 10.17 9.72 9.00 8.73 8.28 7.56
-20.0 -19.8 5.60 5.60 5.60 5.60 5.60 5.60
-19.0 -18.8 6.00 6.00 6.00 6.00 6.00 6.00
-17.0 -16.7 6.30 6.30 6.30 6.30 6.30 6.30
-15.0 -14.7 6.50 6.50 6.50 6.50 6.50 6.50
-13.0 -12.6 6.90 6.90 6.90 6.90 6.90 6.90
-11.0 -10.5 7.00 7.10 7.10 7.10 7.10 7.10
-10.0 -9.5 7.30 7.30 7.30 7.30 7.30 7.30
-9.1 -8.5 7.50 7.50 7.50 7.50 7.50 7.50
-7.6 -7.0 7.60 7.60 7.60 7.60 7.60 7.60
9.0 -5.6 -5.0 7.90 7.90 7.90 7.90 7.90 7.90
-3.7 -3.0 8.30 8.30 8.30 8.30 8.30 8.30
-0.7 0.0 8.90 8.90 8.90 8.90 8.90 8.40
2.2 3.0 9.40 9.40 9.40 9.40 9.20 8.40
4.1 5.0 9.70 9.70 9.70 9.70 9.20 8.40
6.0 7.0 10.00 10.00 10.00 9.70 9.20 8.40
7.9 9.0 10.30 10.30 10.00 9.70 9.20 8.40
9.8 11.0 10.60 10.60 10.00 9.70 9.20 8.40
11.8 13.0 11.00 10.80 10.00 9.70 9.20 8.40
13.7 15.0 11.30 10.80 10.00 9.70 9.20 8.40
36
Four-way cassette indoor units with DC fan motor
Indoor air temp. (°C DB)
Outdoor
Unit size 16 18 20 21 22 24
air temp. (°C)
(kW) TC TC TC TC TC TC
WB DB kW kW kW kW kW kW
-20.0 -19.8 6.22 6.22 6.22 6.22 6.22 6.22
-19.0 -18.8 6.66 6.66 6.66 6.66 6.66 6.66
-17.0 -16.7 6.99 6.99 6.99 6.99 6.99 6.99
-15.0 -14.7 7.22 7.22 7.22 7.22 7.22 7.22
-13.0 -12.6 7.66 7.66 7.66 7.66 7.66 7.66
-11.0 -10.5 7.77 7.88 7.88 7.88 7.88 7.88
-10.0 -9.5 8.10 8.10 8.10 8.10 8.10 8.10
-9.1 -8.5 8.33 8.33 8.33 8.33 8.33 8.33
-7.6 -7.0 8.44 8.44 8.44 8.44 8.44 8.44
10.0 -5.6 -5.0 8.77 8.77 8.77 8.77 8.77 8.77
-3.7 -3.0 9.21 9.21 9.21 9.21 9.21 9.21
-0.7 0.0 9.88 9.88 9.88 9.88 9.88 9.32
2.2 3.0 10.43 10.43 10.43 10.43 10.21 9.32
4.1 5.0 10.77 10.77 10.77 10.77 10.21 9.32
6.0 7.0 11.10 11.10 11.10 10.77 10.21 9.32
7.9 9.0 11.43 11.43 11.10 10.77 10.21 9.32
9.8 11.0 11.77 11.77 11.10 10.77 10.21 9.32
11.8 13.0 12.21 11.99 11.10 10.77 10.21 9.32
13.7 15.0 12.54 11.99 11.10 10.77 10.21 9.32
-20.0 -19.8 7.00 7.00 7.00 7.00 7.00 7.00
-19.0 -18.8 7.50 7.50 7.50 7.50 7.50 7.50
-17.0 -16.7 7.88 7.88 7.88 7.88 7.88 7.88
-15.0 -14.7 8.13 8.13 8.13 8.13 8.13 8.13
-13.0 -12.6 8.63 8.63 8.63 8.63 8.63 8.63
-11.0 -10.5 8.75 8.88 8.88 8.88 8.88 8.88
-10.0 -9.5 9.13 9.13 9.13 9.13 9.13 9.13
-9.1 -8.5 9.38 9.38 9.38 9.38 9.38 9.38
-7.6 -7.0 9.50 9.50 9.50 9.50 9.50 9.50
11.2 -5.6 -5.0 9.88 9.88 9.88 9.88 9.88 9.88
-3.7 -3.0 10.38 10.38 10.38 10.38 10.38 10.38
-0.7 0.0 11.13 11.13 11.13 11.13 11.13 10.50
2.2 3.0 11.75 11.75 11.75 11.75 11.50 10.50
4.1 5.0 12.13 12.13 12.13 12.13 11.50 10.50
6.0 7.0 12.50 12.50 12.50 12.13 11.50 10.50
7.9 9.0 12.88 12.88 12.50 12.13 11.50 10.50
9.8 11.0 13.25 13.25 12.50 12.13 11.50 10.50
11.8 13.0 13.75 13.50 12.50 12.13 11.50 10.50
13.7 15.0 14.13 13.50 12.50 12.13 11.50 10.50
37
Four way cassette indoor units with DC fan motor
Indoor air temp. (°C DB)
Outdoor
Unit size 16 18 20 21 22 24
air temp. (°C)
(kW) TC TC TC TC TC TC
WB DB kW kW kW kW kW kW
-20.0 -19.8 8.40 8.40 8.40 8.40 8.40 8.40
-19.0 -18.8 9.00 9.00 9.00 9.00 9.00 9.00
-17.0 -16.7 9.45 9.45 9.45 9.45 9.45 9.45
-15.0 -14.7 9.75 9.75 9.75 9.75 9.75 9.75
-13.0 -12.6 10.35 10.35 10.35 10.35 10.35 10.35
-11.0 -10.5 10.50 10.65 10.65 10.65 10.65 10.65
-10.0 -9.5 10.95 10.95 10.95 10.95 10.95 10.95
-9.1 -8.5 11.25 11.25 11.25 11.25 11.25 11.25
-7.6 -7.0 11.40 11.40 11.40 11.40 11.40 11.40
14.0 -5.6 -5.0 11.85 11.85 11.85 11.85 11.85 11.85
-3.7 -3.0 12.45 12.45 12.45 12.45 12.45 12.45
-0.7 0.0 13.35 13.35 13.35 13.35 13.35 12.60
2.2 3.0 14.10 14.10 14.10 14.10 13.80 12.60
4.1 5.0 14.55 14.55 14.55 14.55 13.80 12.60
6.0 7.0 15.00 15.00 15.00 14.55 13.80 12.60
7.9 9.0 15.45 15.45 15.00 14.55 13.80 12.60
9.8 11.0 15.90 15.90 15.00 14.55 13.80 12.60
11.8 13.0 16.50 16.20 15.00 14.55 13.80 12.60
13.7 15.0 16.95 16.20 15.00 14.55 13.80 12.60
38
Four-way cassette indoor units with DC fan motor
8. Electrical characteristics
Indoor unit Power supply IFM
Model
Hz Voltage Min. Max. MCA MFA kW FLA
SDV4-56CAF 50/60 220-240 198 254 0.53 5 0.035 0.42
SDV4-71CAF 50/60 220-240 198 254 0.67 5 0.044 0.53
SDV4-80CAF 50/60 220-240 198 254 0.67 5 0.044 0.53
SDV4-90CAF 50/60 220-240 198 254 1.25 5 0.088 1
SDV4-100CAF 50/60 220-240 198 254 1.25 5 0.088 1
SDV4-112CAF 50/60 220-240 198 254 1.25 5 0.088 1
SDV4-140CAF 50/60 220-240 198 254 1.38 5 0.090 1.1
Remarks:
MCA: Min. Current Amps. (A)
MFA: Max. Fuse Amps. (A)
kW: Fan Motor Rated Output (kW)
FLA: Full Load Amps. (A)
IFM: Indoor Fan Motor
Note:
1) Voltage range
Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above
listed range limits.
2) Maximum allowable voltage unbalance between phase is 2%.
3) MCA; MCA = 1.25 × FLA
4) Select wire size based on the MCA.
5) Instead of fuse, use Circuit Breaker.
39
Four way cassette indoor units with DC fan motor
9. Sound levels
Four-way cassette type
1.4m
Note:
1. Sound values are measured in a seSDV4-anechoic room, at a position 1.4m downward from the unit center
2. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Sound pressure level dB(A)
Model
H M L
SDV4-56CAF 43 38 34
SDV4-71CAF 45 39 34
SDV4-80CAF 46 40 35
SDV4-90CAF 47 41 36
SDV4-100CAF 47 41 36
SDV4-112CAF 47 41 36
SDV4-140CAF 50 45 35
40
Four-way cassette indoor units with DC fan motor
Octave band level
SDV4-28CAF ~ SDV4-36CAF SDV4-45CAF ~ SDV4-56CAF
Audibility limits of
continuous white
sound Audibility limits of
continuous white
sound
Audibility limits of
continuous white
sound
Audibility limits of
continuous white
sound
Octave band center frequency(Hz)
41
Four way cassette indoor units with DC fan motor
10. Accessories
Attached accessories
Name Shape Quantity
Nut 8
Washer 8
Bolt M6 4
Connection pipe 1
Sponge (250×250×10) 1
Sponge (60×100×5) 1
Outlet pipe sheath 1
Tightening band 5
Signal line 1
Remote controller 1
Frame 1
42
Wall mounted indoor units with DC fan motor
43
Wall mounted indoor units with DC fan motor
Specifications .................................................................... 47
Dimensions ........................................................................ 49
Accessories........................................................................ 64
44
Wall mounted indoor units with DC fan motor
1. Features
1.2.1 Multi-refrigerant outlet pipe method: left\right\rear, more flexible for installation.
1.2.2 Longer connection pipe, Gas pipe: 468mm /Liquid pipe: 550mm, more flexible for the installation.
1.2.3 Adopts new fixing plate, easy for installation and stable.
1.2.4 The EXV is built-in the indoor unit, compact size, and convenient for the installation.
1.2.5 The front panel can be lifted up to max. 65 degree or be removed for maintaining. Easy access for
wiring and service. socket on main control board for water pump and PCB can be customized if you
need water pump function.
1.4.1 Adoption of the Fujikoki brand mechanical expansion valve which has 2000 steps, ensure precise flow
control, as well lower modulation noise when EXV operating.
45
Wall mounted indoor units with DC fan motor
1.4.2 Smoother airflow with less turbulence. Owing to the multiple-blade fan and the air guide design, the
airflow is getting smoother and more comfortable.
1.4.3 Louver’s air swing angle can be up to 90º.
1.4.4 Advanced 3-D spiral fan design reduces air resistance and operating sound
The motor bearing with unique design makes less operation vibration.
1.5 Wired control compatible. RM05 remote wireless controller which can set the indoor unit
address is standard, and wired controller is optional.
1.6.1 Efficiency can be up to 90%. Contrast with the AC fan motor, the power consumption of DC fan motor
can reduce up to 30%.
Power Inpu t:W DC and AC motors power contrast
200
DC moto r
150
AC moto r
100
50
Air Flow:CFM
0
1.6.2 The motor adopts fully enclosed structure design. The motor bearing can operate 80,000 hours
continuously and easy for maintenance.
1.6.3 Thanks to the DC fan motor, this wall-mounted indoor unit can meet the latest CE certification
requirements.
46
Wall mounted indoor units with DC fan motor
2. Specifications
Model SDV4-22HAF SDV4-28HAF SDV4-36HAF SDV4-45HAF
Power supply V-Ph-Hz 220-240V~, 1Ph, 50Hz
Capacity kW 2.2 2.8 3.6 4.5
Cooling Input W 19 19 22 26
Rated current A 0.28 0.28 0.31 0.35
Capacity kW 2.4 3.2 4.0 5.0
Heating Input W 19 19 22 26
Rated current A 0.28 0.28 0.31 0.35
Model WZDK20-38G WZDK20-38G WZDK20-38G WZDK20-38G
Type DC motor
Indoor fan
Brand Welling & Nidec
motor
Input W 17 17 20 24
Speed (h/m/l) r/min 810/760/700 810/760/700 880/810/760 930/840/740
Number of rows 2 2 2 2
Tube pitch x row pitch mm 21x13.37
Fin spacing mm 1.5
47
Wall mounted indoor units with DC fan motor
Number of circuits 6 6 6 6
3
Indoor air flow (H/M/L) m /h 915/840/708 1211/916/714 1373/915/710 1373/915/710
Indoor noise level (H/M/L) dB(A) 45/38/34 46/38//34 46/38//34 46/38//34
Dimension
mm 1070×230×315 1250×325×230
(W×H×D)
Indoor unit
Packing (W×H×D) mm 1180×315×415 1345×335×430
Net/Gross weight kg 14.4/18.4 18.3/23.4 18.3/23.4 18.3/23.4
Refrigerant type R410A
Type EXV (Mechanical gear modulation, Integrated with the evaporator)
Throttle
Model EFM-25YGMISZ-6M-A
Design pressure(H/L) MPa 4.4/2.6
Refrigerant Liquid side/ Gas
mm Ф9.53/ Ф15.9 Ф9.53/ Ф15.9
piping side
2
Connecting Power wiring mm 3x2.5
2
wiring Signal wiring mm 3x0.75
Drainage water pipe diameter mm OD Ф16.5
Controller Wireless remote controller (RM05) (Standard)
Notes: 1. Nominal cooling capacities are based on the following conditions: return air temperature: 27°C DB, 19°C WB,
outdoor temperature: 35°C DB, equivalent ref. piping: 8m (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB, outdoor temperature:
7°C DB, 6°C WB, equivalent ref. piping: 8m (horizontal)
48
Wall mounted indoor units with DC fan motor
3. Dimensions
Outline dimension and air outlet opening size
SDV4-22HAF, SDV4-28HAF, SDV4-36HAF
Main dimension:
Outer Length: 915mm, Height: 290mm, Depth: 230mm
Filter length: 663mm
Gas pipe: Ф12.7mm (length: approx. 468mm)
Liquid pipe: Ф6.35mm (length: approx. 550mm)
SDV4-45HAF, SDV4-56HAF
Main dimension:
Outer Length: 1070mm, Height: 315mm, Depth: 230mm
Filter length: 813mm
SDV4-45HAF :Gas pipe:Ф12.7mm (length: approx. 468mm)
Liquid pipe: Ф9.53 (length: approx. 550mm)
SDV4-56HAF: Gas pipe: Ф15.9mm (length: approx. 550mm)
Liquid pipe: Ф9.5mm (length: approx.468mm)
49
Wall mounted indoor units with DC fan motor
SDV4-71HAF, SDV4-80HAF, SDV4-90HAF
Main dimension:
Outer Length: 1250mm, Height: 245mm, Depth: 325mm
Filter length: 952mm
Gas pipe: Ф15.9mm (length: approx. 550mm)
Liquid tube: Ф9.5mm (length: approx.468mm)
50
Wall mounted indoor units with DC fan motor
4. Piping Diagrams
SDV4-22HAF, SDV4-28HAF, SDV4-36HAF, SDV4-45HAF, SDV4-56HAF
motor
fan
T2B flare nut
gas side
T1 EXV
T2
liquid side
51
Wall mounted indoor units with DC fan motor
5. Wiring Diagrams
SDV4-22HAF, SDV4-28HAF, SDV4-36HAF, SDV4-45HAF, SDV4-56HAF
52
Wall mounted indoor units with DC fan motor
Function setting indication
53
Wall mounted indoor units with DC fan motor
6. Capacity Tables
6.1 Cooling
TC: total capacity SC: sensible capacity WB: wet-bulb temperature DB: dry-bulb temperature
Indoor Indoor temperature (°C, WB/DB)
Outdoor
unit 14/20 16/23 18/26 19/27 20/28 22/30 24/32
temperature
size TC SC TC SC TC SC TC SC TC SC TC SC TC SC
(°C, WB)
(kW) kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.6 1.6 2.9 1.5
12.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.6 1.6 2.8 1.5
14.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.6 1.6 2.8 1.5
16.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.6 1.6 2.8 1.5
18.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.6 1.6 2.8 1.4
20.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.6 1.6 2.7 1.4
21.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.6 1.6 2.7 1.4
23.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.5 1.5 2.7 1.4
25.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.5 1.5 2.6 1.4
2.2 27.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.5 1.5 2.6 1.4
29.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.4 1.4 2.5 1.4
31.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.4 1.4 2.5 1.4
33.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.4 1.4 2.4 1.4
35.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.3 1.3 2.4 1.4
37.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.3 1.6 2.3 1.3 2.3 1.4
39.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.2 1.5 2.3 1.3 2.3 1.4
42.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.2 1.5 2.3 1.3 2.3 1.4
44.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.2 1.5 2.3 1.3 2.3 1.4
46.0 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.5 2.2 1.5 2.3 1.3 2.3 1.4
10.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.7 2.0
12.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.6 2.0
14.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.6 2.0
16.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.5 1.9
18.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.5 1.9
20.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.4 1.9
21.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.4 1.9
23.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.3 2.0 3.4 1.9
25.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.2 1.9 3.3 1.9
2.8 27.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.2 1.9 3.3 1.9
29.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.1 1.8 3.2 1.8
31.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.1 1.8 3.2 1.7
33.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 3.0 1.9 3.1 1.8 3.1 1.7
35.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 2.9 1.9 3.0 1.8 3.1 1.7
37.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 2.9 1.9 3.0 1.8 3.0 1.7
39.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 2.9 1.9 3.0 1.9 3.0 1.7
42.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 2.9 1.9 3.0 1.9 3.0 1.7
44.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 2.9 1.9 3.0 1.9 3.0 1.7
46.0 1.9 1.6 2.3 1.8 2.6 1.9 2.8 1.9 2.9 1.9 3.0 1.9 3.0 1.7
54
Wall mounted indoor units with DC fan motor
55
Wall mounted indoor units with DC fan motor
56
Wall mounted indoor units with DC fan motor
57
Wall mounted indoor units with DC fan motor
6.2 Heating
TC: total capacity WB: wet-bulb temperature DB: dry-bulb temperature
Indoor temperature (°C, DB)
Indoor Outdoor
16 18 20 21 22 24
unit size temperature (°C)
TC TC TC TC TC TC
(kW)
DB WB kW kW kW kW kW kW
-19.8 -20 1.34 1.34 1.34 1.34 1.34 1.34
-18.8 -19 1.44 1.44 1.44 1.44 1.44 1.44
-16.7 -17 1.51 1.51 1.51 1.51 1.51 1.51
-13.7 -15 1.56 1.56 1.56 1.56 1.56 1.56
-11.8 -13 1.66 1.66 1.66 1.66 1.66 1.66
-9.8 -11 1.68 1.70 1.70 1.70 1.70 1.70
-9.5 -10 1.75 1.75 1.75 1.75 1.75 1.75
-8.5 -9.1 1.80 1.80 1.80 1.80 1.80 1.80
-7 -7.6 1.82 1.82 1.82 1.82 1.82 1.82
2.4 -5 -5.6 1.90 1.90 1.90 1.90 1.90 1.90
-3 -3.7 1.99 1.99 1.99 1.99 1.99 1.99
0 -0.7 2.14 2.14 2.14 2.14 2.14 2.02
3 2.2 2.26 2.26 2.26 2.26 2.21 2.02
5 4.1 2.33 2.33 2.33 2.33 2.21 2.02
7 6 2.40 2.40 2.40 2.33 2.21 2.02
9 7.9 2.47 2.47 2.40 2.33 2.21 2.02
11 9.8 2.54 2.54 2.40 2.33 2.21 2.02
13 11.8 2.64 2.59 2.40 2.33 2.21 2.02
15 13.7 2.71 2.59 2.40 2.33 2.21 2.02
-19.8 -20 1.79 1.79 1.79 1.79 1.79 1.79
-18.8 -19 1.92 1.92 1.92 1.92 1.92 1.92
-16.7 -17 2.02 2.02 2.02 2.02 2.02 2.02
-13.7 -15 2.08 2.08 2.08 2.08 2.08 2.08
-11.8 -13 2.21 2.21 2.21 2.21 2.21 2.21
-9.8 -11 2.24 2.27 2.27 2.27 2.27 2.27
-9.5 -10 2.34 2.34 2.34 2.34 2.34 2.34
-8.5 -9.1 2.40 2.40 2.40 2.40 2.40 2.40
-7 -7.6 2.43 2.43 2.43 2.43 2.43 2.43
3.2 -5 -5.6 2.53 2.53 2.53 2.53 2.53 2.53
-3 -3.7 2.66 2.66 2.66 2.66 2.66 2.66
0 -0.7 2.85 2.85 2.85 2.85 2.85 2.69
3 2.2 3.01 3.01 3.01 3.01 2.94 2.69
5 4.1 3.10 3.10 3.10 3.10 2.94 2.69
7 6 3.20 3.20 3.20 3.10 2.94 2.69
9 7.9 3.30 3.30 3.20 3.10 2.94 2.69
11 9.8 3.39 3.39 3.20 3.10 2.94 2.69
13 11.8 3.52 3.46 3.20 3.10 2.94 2.69
15 13.7 3.62 3.46 3.20 3.10 2.94 2.69
58
Wall mounted indoor units with DC fan motor
Indoor temperature (°C, DB)
Indoor Outdoor
16 18 20 21 22 24
unit size temperature (°C)
TC TC TC TC TC TC
(kW)
DB WB kW kW kW kW kW kW
-19.8 -20 2.24 2.24 2.24 2.24 2.24 2.24
-18.8 -19 2.40 2.40 2.40 2.40 2.40 2.40
-16.7 -17 2.52 2.52 2.52 2.52 2.52 2.52
-13.7 -15 2.60 2.60 2.60 2.60 2.60 2.60
-11.8 -13 2.76 2.76 2.76 2.76 2.76 2.76
-9.8 -11 2.80 2.84 2.84 2.84 2.84 2.84
-9.5 -10 2.92 2.92 2.92 2.92 2.92 2.92
-8.5 -9.1 3.00 3.00 3.00 3.00 3.00 3.00
-7 -7.6 3.04 3.04 3.04 3.04 3.04 3.04
4.0 -5 -5.6 3.16 3.16 3.16 3.16 3.16 3.16
-3 -3.7 3.32 3.32 3.32 3.32 3.32 3.32
0 -0.7 3.56 3.56 3.56 3.56 3.56 3.36
3 2.2 3.76 3.76 3.76 3.76 3.68 3.36
5 4.1 3.88 3.88 3.88 3.88 3.68 3.36
7 6 4.00 4.00 4.00 3.88 3.68 3.36
9 7.9 4.12 4.12 4.00 3.88 3.68 3.36
11 9.8 4.24 4.24 4.00 3.88 3.68 3.36
13 11.8 4.40 4.32 4.00 3.88 3.68 3.36
15 13.7 4.52 4.32 4.00 3.88 3.68 3.36
-19.8 -20 2.80 2.80 2.80 2.80 2.80 2.80
-18.8 -19 3.00 3.00 3.00 3.00 3.00 3.00
-16.7 -17 3.15 3.15 3.15 3.15 3.15 3.15
-13.7 -15 3.25 3.25 3.25 3.25 3.25 3.25
-11.8 -13 3.45 3.45 3.45 3.45 3.45 3.45
-9.8 -11 3.50 3.55 3.55 3.55 3.55 3.55
-9.5 -10 3.65 3.65 3.65 3.65 3.65 3.65
-8.5 -9.1 3.75 3.75 3.75 3.75 3.75 3.75
-7 -7.6 3.80 3.80 3.80 3.80 3.80 3.80
5.0 -5 -5.6 3.95 3.95 3.95 3.95 3.95 3.95
-3 -3.7 4.15 4.15 4.15 4.15 4.15 4.15
0 -0.7 4.45 4.45 4.45 4.45 4.45 4.20
3 2.2 4.70 4.70 4.70 4.70 4.60 4.20
5 4.1 4.85 4.85 4.85 4.85 4.60 4.20
7 6 5.00 5.00 5.00 4.85 4.60 4.20
9 7.9 5.15 5.15 5.00 4.85 4.60 4.20
11 9.8 5.30 5.30 5.00 4.85 4.60 4.20
13 11.8 5.50 5.40 5.00 4.85 4.60 4.20
15 13.7 5.65 5.40 5.00 4.85 4.60 4.20
59
Wall mounted indoor units with DC fan motor
Indoor temperature (°C, DB)
Indoor Outdoor
16 18 20 21 22 24
unit size temperature (°C)
TC TC TC TC TC TC
(kW)
DB WB kW kW kW kW kW kW
-19.8 -20 3.53 3.53 3.53 3.53 3.53 3.53
-18.8 -19 3.78 3.78 3.78 3.78 3.78 3.78
-16.7 -17 3.97 3.97 3.97 3.97 3.97 3.97
-13.7 -15 4.10 4.10 4.10 4.10 4.10 4.10
-11.8 -13 4.35 4.35 4.35 4.35 4.35 4.35
-9.8 -11 4.41 4.47 4.47 4.47 4.47 4.47
-9.5 -10 4.60 4.60 4.60 4.60 4.60 4.60
-8.5 -9.1 4.73 4.73 4.73 4.73 4.73 4.73
-7 -7.6 4.79 4.79 4.79 4.79 4.79 4.79
6.3 -5 -5.6 4.98 4.98 4.98 4.98 4.98 4.98
-3 -3.7 5.23 5.23 5.23 5.23 5.23 5.23
0 -0.7 5.61 5.61 5.61 5.61 5.61 5.29
3 2.2 5.92 5.92 5.92 5.92 5.80 5.29
5 4.1 6.11 6.11 6.11 6.11 5.80 5.29
7 6 6.30 6.30 6.30 6.11 5.80 5.29
9 7.9 6.49 6.49 6.30 6.11 5.80 5.29
11 9.8 6.68 6.68 6.30 6.11 5.80 5.29
13 11.8 6.93 6.80 6.30 6.11 5.80 5.29
15 13.7 7.12 6.80 6.30 6.11 5.80 5.29
-19.8 -20 4.48 4.48 4.48 4.48 4.48 4.48
-18.8 -19 4.80 4.80 4.80 4.80 4.80 4.80
-16.7 -17 5.04 5.04 5.04 5.04 5.04 5.04
-13.7 -15 5.20 5.20 5.20 5.20 5.20 5.20
-11.8 -13 5.52 5.52 5.52 5.52 5.52 5.52
-9.8 -11 5.60 5.68 5.68 5.68 5.68 5.68
-9.5 -10 5.84 5.84 5.84 5.84 5.84 5.84
-8.5 -9.1 6.00 6.00 6.00 6.00 6.00 6.00
-7 -7.6 6.08 6.08 6.08 6.08 6.08 6.08
8.0 -5 -5.6 6.32 6.32 6.32 6.32 6.32 6.32
-3 -3.7 6.64 6.64 6.64 6.64 6.64 6.64
0 -0.7 7.12 7.12 7.12 7.12 7.12 6.72
3 2.2 7.52 7.52 7.52 7.52 7.36 6.72
5 4.1 7.76 7.76 7.76 7.76 7.36 6.72
7 6 8.00 8.00 8.00 7.76 7.36 6.72
9 7.9 8.24 8.24 8.00 7.76 7.36 6.72
11 9.8 8.48 8.48 8.00 7.76 7.36 6.72
13 11.8 8.80 8.64 8.00 7.76 7.36 6.72
15 13.7 9.04 8.64 8.00 7.76 7.36 6.72
60
Wall mounted indoor units with DC fan motor
Indoor temperature (°C, DB)
Indoor Outdoor
16 18 20 21 22 24
unit size temperature (°C)
TC TC TC TC TC TC
(kW)
DB WB kW kW kW kW kW kW
-19.8 -20 5.04 5.04 5.04 5.04 5.04 5.04
-18.8 -19 5.40 5.40 5.40 5.40 5.40 5.40
-16.7 -17 5.67 5.67 5.67 5.67 5.67 5.67
-13.7 -15 5.85 5.85 5.85 5.85 5.85 5.85
-11.8 -13 6.21 6.21 6.21 6.21 6.21 6.21
-9.8 -11 6.30 6.39 6.39 6.39 6.39 6.39
-9.5 -10 6.57 6.57 6.57 6.57 6.57 6.57
-8.5 -9.1 6.75 6.75 6.75 6.75 6.75 6.75
-7 -7.6 6.84 6.84 6.84 6.84 6.84 6.84
9 -5 -5.6 7.11 7.11 7.11 7.11 7.11 7.11
-3 -3.7 7.47 7.47 7.47 7.47 7.47 7.47
0 -0.7 8.01 8.01 8.01 8.01 8.01 7.56
3 2.2 8.46 8.46 8.46 8.46 8.28 7.56
5 4.1 8.73 8.73 8.73 8.73 8.28 7.56
7 6 9.00 9.00 9.00 8.73 8.28 7.56
9 7.9 9.27 9.27 9.00 8.73 8.28 7.56
11 9.8 9.54 9.54 9.00 8.73 8.28 7.56
13 11.8 9.90 9.72 9.00 8.73 8.28 7.56
15 13.7 10.17 9.72 9.00 8.73 8.28 7.56
-19.8 -20 5.60 5.60 5.60 5.60 5.60 5.60
-18.8 -19 6.00 6.00 6.00 6.00 6.00 6.00
-16.7 -17 6.30 6.30 6.30 6.30 6.30 6.30
-13.7 -15 6.50 6.50 6.50 6.50 6.50 6.50
-11.8 -13 6.90 6.90 6.90 6.90 6.90 6.90
-9.8 -11 7.00 7.10 7.10 7.10 7.10 7.10
-9.5 -10 7.30 7.30 7.30 7.30 7.30 7.30
-8.5 -9.1 7.50 7.50 7.50 7.50 7.50 7.50
-7 -7.6 7.60 7.60 7.60 7.60 7.60 7.60
10 -5 -5.6 7.90 7.90 7.90 7.90 7.90 7.90
-3 -3.7 8.30 8.30 8.30 8.30 8.30 8.30
0 -0.7 8.90 8.90 8.90 8.90 8.90 8.40
3 2.2 9.40 9.40 9.40 9.40 9.20 8.40
5 4.1 9.70 9.70 9.70 9.70 9.20 8.40
7 6 10.00 10.00 10.00 9.70 9.20 8.40
9 7.9 10.30 10.30 10.00 9.70 9.20 8.40
11 9.8 10.60 10.60 10.00 9.70 9.20 8.40
13 11.8 11.00 10.80 10.00 9.70 9.20 8.40
15 13.7 11.30 10.80 10.00 9.70 9.20 8.40
Note: The above table is only the heat pump heating capacity, for the type with electrical heater, the total
capacity should plus the additional electrical heating capacity, which is a constant data.
61
Wall mounted indoor units with DC fan motor
7. Electrical Characteristics
Indoor Unit Power Supply IFM
Model
Hz Voltage Min. Max. MCA MFA KW FLA
SDV4-22HAF 50 220~240 198 253 0.24 6 0.02 0.19
SDV4-28HAF 50 220~240 198 253 0.24 6 0.02 0.19
SDV4-36HAF 50 220~240 198 253 0.28 6 0.02 0.22
SDV4-45HAF 50 220~240 198 253 0.31 6 0.02 0.25
SDV4-56HAF 50 220~240 198 253 0.36 6 0.02 0.29
SDV4-71HAF 50 220~240 198 253 0.54 6 0.06 0.43
SDV4-80HAF 50 220~240 198 253 0.7 6 0.06 0.56
SDV4-90HAF 50 220~240 198 253 0.7 6 0.06 0.56
Remark:
MCA: Min. Current Amps. (A)
MFA: Max. Fuse Amps. (A)
KW: Fan Motor Rated Output (kW)
FLA: Full Load Amps. (A)
IFM:Indoor Fan Motor
62
Wall mounted indoor units with DC fan motor
8. Sound Levels
8.1 Test condition
0.8 m
63
Wall mounted indoor units with DC fan motor
9. Accessories
9.1 Standard accessories
Name Quantity Shape Usage
4. Wrapping tape 1 /
5. Drain pipe 1 /
7. Remote controller
1 /
(including operation manual)
9. Mounting screw
2 Installation Holder for remote controller
(ST2.9 10-C-H)
64
Ceiling & floor standing indoor units with DC fan motor
65
Ceiling & floor standing indoor units with DC fan motor
66
Ceiling & floor standing indoor units with DC fan motor
1. Features
1.1 Panel with LED display
Efficiency can be up to 90%. Contrast with the AC fan motor, the power consumption of DC fan motor can
reduce up to 30%.
Power Inpu t:W DC and AC motors power contrast
200
DC moto r
150
AC moto r
100
50
Air Flow:CFM
0
1.8.1 The ceiling type can be easily installed into a corner of the ceiling even if the ceiling is very narrow.
1.8.2 It is especially useful when installation of an air conditioner in the center of the ceiling is impossible
due to a structure such as one lighting.
1.8.3 The EXV is built-in the indoor unit, compact size, and convenient for the installation.
1.8.4 Reserved the socket on main control board for water pump and PCB can be customized if you need
water pump function.
1.10 Two direction auto swing (vertical & horizontal) and wide
angle air flow
67
Ceiling & floor standing indoor units with DC fan motor
1.12 Wired control compatible
RM05 remote wireless controller which can set the indoor unit address is standard, and wired controller
is optional.
When the indoor unit is powered off, it will auto restart when powered on again after 3 minutes and
operate in the original state.
68
Ceiling & floor standing indoor units with DC fan motor
2. Specifications
Model SDV4-36FAF SDV4-45FAF SDV4-56FAF SDV4-71FAF
Power supply V- Ph-Hz 220-240V, 1Ph, 50/60Hz
Capacity kW 3.6 4.5 5.6 7.1
Cooling Input W 23 94 94 94
Rated current A 0.32 0.72 0.72 0.72
Capacity kW 4 5 6.3 8
Heating Input W 23 94 94 94
Rated current A 0.32 0.72 0.72 0.72
Model WZDK100-38GS-2 WZDK100-38GS-2 WZDK100-38GS-2 WZDK100-38GS-2
Type DC motor
Indoor fan Brand Panasonic
motor Input W 23 94 94 94
Output W 20 80 80 80
Speed (h/m/l) r/min 756/666/592 1310/1190/1040 1310/1190/1040 1310/1190/1040
Number of rows 2 3 3 3
Tube pitch * row pitch mm 25.4*22 25.4*22 25.4*22 25.4*22
Fin spacing mm 1.8 1.8 1.8 1.8
Fin type Hydrophilic aluminum
Indoor coil
Tube outside Ф9.52
mm
diameter and type Inner groove tube
length * height * width mm 804*254*44 804*254*66 804*254*66 804*254*66
Number of circuits 3 3 3 3
3
Indoor air flow (H/M/L) m /h 550/480/420 930/830/720 930/830/720 930/830/720
Indoor noise level (H/M/L) dB(A) 40/38/36 43/41/38 43/41/38 43/41/38
Dimension (W*H*D) mm 990*203*660 990*203*660 990*203*660 990*203*660
Indoor unit Packing (W*H*D) mm 1089*296*744 1089*296*744 1089*296*744 1089*296*744
Net/Gross weight kg 25/31 27/33 27/33 27/33
Refrigerant type R410A
Type EXV (Built-in)
Throttle
Model BD20FKS(L)
Design pressure MPa 4.4/2.6
Refrigerant
Liquid side/ Gas side mm Ф6.35/ Ф12.7 Ф9.52/ Ф15.9
piping
2
Connecting Power wiring mm 3*2.5(L≤20m); 3*3.5(L≤50m)
2
wiring Signal wiring mm 3*0.75
Drainage water pipe diameter ODФ25
Controller Wireless remote controller (RM05) (Standard)
Notes: 1. Nominal cooling capacities are based on the following conditions: return air temperature: 27°CDB, 19°CWB,
outdoor temperature:35°CDB,equivalent ref. Piping: 8m(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temperature: 20°CDB, outdoor temperature:
7°CDB,6°CWB,equivalent ref. Piping: 8m(horizontal)
69
Ceiling & floor standing indoor units with DC fan motor
Type DC motor
Indoor fan Brand Panasonnic
motor Input W 126 126 65 * 2 65 * 2
Output W 100 100 55* 2 55* 2
Speed (h/m/l) r/min 1310/1210/1115 1310/1210/1115 1170/1070/995 1170/1070/995
Number of rows 3 3 3 3
Tube pitch * row
mm 25.4*22 25.4*22 25.4*22 25.4*22
pitch
Fin spacing mm 1.8 1.8 1.8 1.8
Fin type Hydrophilic aluminum
Indoor coil
Tube outside Ф9.52
mm
diameter and type Inner groove tube
length * height *
mm 1094*254*66 1360*254*66
width
Number of circuits 5 5 5 5
3
Indoor air flow (H/M/L) m /h 1,280/1,170/1,050 1,280/1,170/1,050 1,890/1,700/1,580 1,890/1,700/1,580
70
Ceiling & floor standing indoor units with DC fan motor
3. Dimensions
3.1 Outline dimension
kW A B C D E F G
3.6-7.1 990 660 203 505 506 907 200
8.0-9.0 1280 660 203 795 506 1195 200
11.2-14.0 1670 680 244 1070 450 1542 200
71
Ceiling & floor standing indoor units with DC fan motor
4. Service Spaces
SDV4-36FAF, SDV4-45FAF, SDV4-56FAF, SDV4-71FAF,
SDV4-80FAF, SDV4-90FAF, SDV4-112FAF, SDV4-140FAF
>600mm
Obstacle
>600mm
Piping connection
Keep more than 600mm clearance between the unit and left/right side wall.
Air Outlet
Obstacle
600mm
As well 600mm and up between the front panel and wall. For well ventilation.
Drop ceiling
>20
Air Outlet
Keep 20mm up between the rear and wall if standing installed. As well 20mm between top and the drop
ceiling if under ceiling installed
Note:
This indoor unit may be installed on ceilings up to 3.5 m in height. However, if the ceiling is higher
than 2.7m, the remote control with follow me function should be customized.
72
Ceiling & floor standing indoor units with DC fan motor
5. Piping Diagrams
SDV4-36FAF, SDV4-45FAF, SDV4-56FAF, SDV4-71FAF,
SDV4-80FAF, SDV4-90FAF, SDV4-112FAF, SDV4-140FAF
motor
fan
T2B flare nut
gas side
T1 EXV
T2
liquid side
73
Ceiling & floor standing indoor units with DC fan motor
6. Wiring Diagrams
SDV4-36FAF, SDV4-45FAF, SDV4-56FAF, SDV4-71FAF, SDV4-80FAF, SDV4-90FAF
74
Ceiling & floor standing indoor units with DC fan motor
SDV4-140FAF
75
Ceiling & floor standing indoor units with DC fan motor
Power settings
Note: Base on different purposes to setting the switch cords on PC panel of indoor electrical control box. Once finish the
setting, please cut off the main power, and then input power again, otherwise, setting function could not work.
SW1 definition
SW2 definition
76
Ceiling & floor standing indoor units with DC fan motor
SW5 definition
77
Ceiling & floor standing indoor units with DC fan motor
7. Capacity Tables
7.1 Cooling
TC: total capacity SC: sensible capacity WB: wet-bulb temperature DB: dry-bulb temperature
Indoor temperature (°C WB/DB)
Indoor Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32
Unit size temperature
(kW) (°C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.7 2.5
12.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.7 2.5
14.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.6 2.4
16.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.5 2.4
18.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.5 2.4
20.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.4 2.3
21.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.3 2.4 4.4 2.3
23.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.1 2.3 4.3 2.2
25.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.1 2.3 4.2 2.2
3.6 27.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.0 2.2 4.2 2.2
29.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.0 2.2 4.1 2.2
31.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.2 2.6 4.1 2.2
33.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.2 2.6 3.9 2.1
35.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.8 2.5 4.2 2.6 3.9 2.1
37.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.7 2.4 3.8 2.3 3.9 2.1
39.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.7 2.4 3.8 2.3 3.8 2.1
42.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.7 2.4 3.8 2.3 3.8 2.1
44.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.7 2.4 3.8 2.3 3.8 2.1
46.0 2.5 1.9 2.9 2.1 3.4 2.3 3.6 2.4 3.7 2.4 3.8 2.3 3.8 2.1
10.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.9 3.0
12.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.9 3.0
14.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.8 3.0
16.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.6 2.9
18.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.7 3.0
20.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.7 3.0
21.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.6 3.0
23.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.3 3.4 5.5 3.0
25.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.2 3.0 5.4 2.9
4.5 27.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.1 3.0 5.2 2.8
29.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.1 2.9 5.2 2.8
31.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 5.0 2.9 5.1 2.7
33.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 4.9 2.8 5.1 2.7
35.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 4.8 2.8 5.0 2.7
37.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.8 3.0 4.8 2.9 4.9 2.6
39.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.6 2.8 4.7 2.8 4.8 2.6
42.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.6 2.8 4.7 2.8 4.8 2.6
44.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.6 2.8 4.7 2.8 4.8 2.6
46.0 3.1 2.4 3.7 2.6 4.2 2.8 4.5 2.9 4.6 2.8 4.7 3.1 4.8 2.6
78
Ceiling & floor standing indoor units with DC fan motor
Indoor temperature (°C WB/DB)
Indoor Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32
Unit size temperature
(kW) (°C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 7.3 3.5
12.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 7.2 3.5
14.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 7.1 3.5
16.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 7.0 3.4
18.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 6.8 3.4
20.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 6.7 3.3
21.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 6.6 3.3
23.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 6.6 3.3
25.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.6 3.6 6.5 3.2
5.6 27.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.4 3.5 6.4 3.2
29.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.3 3.5 6.4 3.3
31.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.2 3.4 6.2 3.2
33.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.2 3.4 6.2 3.2
35.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 6.0 3.3 6.0 3.1
37.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.9 3.5 5.9 3.2 6.0 3.1
39.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.7 3.4 5.8 3.2 6.0 3.1
42.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.7 3.4 5.8 3.2 6.0 3.1
44.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.7 3.4 5.8 3.2 6.0 3.1
46.0 3.9 2.7 4.6 3.0 5.3 3.3 5.6 3.4 5.7 3.7 5.8 3.2 6.0 3.1
10.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 9.2 4.6
12.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 9.1 4.5
14.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 9.0 4.5
16.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 8.9 4.4
18.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 8.7 4.3
20.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 8.5 4.2
21.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 8.4 4.2
23.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 8.3 4.1
25.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.4 4.5 8.2 4.1
7.1 27.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.4 8.1 4.3 8.2 4.1
29.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.5 8.0 4.3 8.1 4.1
31.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.5 7.9 4.3 7.8 4.0
33.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.5 7.8 4.2 7.8 4.0
35.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.5 4.5 7.6 4.1 7.7 3.9
37.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.4 4.4 7.5 4.1 7.6 4.0
39.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.2 4.3 7.4 4.1 7.6 4.0
42.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.2 4.3 7.4 4.1 7.6 4.0
44.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.2 4.3 7.4 4.1 7.6 4.0
46.0 4.9 3.6 5.8 4.0 6.7 4.3 7.1 4.5 7.2 4.3 7.4 4.1 7.6 4.0
10.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 10.4 5.6
12.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 10.2 5.5
14.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 10.2 5.5
16.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 10.0 5.4
18.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 9.8 5.3
20.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 9.6 5.2
21.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 9.4 5.1
23.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 9.4 5.1
25.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.4 5.5 9.3 5.0
8.0 27.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.4 9.1 5.3 9.2 5.1
29.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.5 9.0 5.3 9.1 5.0
31.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.5 8.9 5.2 8.8 4.8
33.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.5 8.8 5.2 8.8 4.8
35.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.4 5.5 8.6 5.1 8.6 4.8
37.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.3 5.4 8.4 5.0 8.6 4.9
39.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.1 5.3 8.3 5.0 8.6 4.9
42.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.1 5.3 8.3 5.0 8.6 4.9
44.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.1 5.3 8.3 5.0 8.6 4.9
46.0 5.5 4.4 6.6 4.9 7.5 5.3 8.0 5.5 8.1 5.3 8.3 5.0 8.6 4.9
79
Ceiling & floor standing indoor units with DC fan motor
Indoor temperature (°C WB/DB)
Indoor Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32
Unit size temperature
(kW) (°C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 11.7 6.0
12.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 11.5 5.9
14.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 11.4 5.9
16.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 11.3 5.8
18.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 11.0 5.8
20.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 10.8 5.7
21.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 10.6 5.6
23.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 10.5 5.5
25.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.6 6.1 10.4 5.5
9.0 27.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.3 5.9 10.4 5.4
29.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.1 5.7 10.3 5.4
31.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 10.0 5.7 9.9 5.3
33.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.6 6.0 9.9 5.6 9.9 5.3
35.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.5 6.0 9.6 5.5 9.7 5.3
37.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.3 5.8 9.5 5.4 9.6 5.3
39.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.2 5.7 9.4 5.3 9.6 5.3
42.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.2 5.7 9.4 5.3 9.6 5.3
44.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.2 5.7 9.4 5.3 9.6 5.3
46.0 6.2 4.9 7.3 5.3 8.4 5.8 9.0 5.9 9.2 5.7 9.4 5.3 9.6 5.3
10.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 13.0 7.3
12.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 12.8 7.2
14.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 12.7 7.1
16.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 12.5 7.0
18.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 12.2 6.8
20.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 12.0 6.7
21.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.9 7.3 11.8 6.6
23.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.7 7.3 11.7 6.6
25.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.6 7.2 11.6 6.5
10.0 27.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.5 7.1 11.5 6.6
29.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.4 7.1 11.4 6.5
31.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.3 7.0 11.0 6.3
33.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.6 7.0 11.2 6.9 11.0 6.3
35.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.5 6.9 10.8 6.7 10.8 6.3
37.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.4 6.9 10.8 6.7 10.7 6.2
39.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.2 6.7 10.4 6.6 10.7 6.3
42.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.2 6.7 10.4 6.6 10.7 6.3
44.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.2 6.7 10.4 6.6 10.7 6.3
46.0 6.9 5.6 8.1 6.2 9.4 6.9 10.0 7.0 10.2 6.7 10.4 6.6 10.7 6.3
10.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 15.5 8.2
12.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 14.4 7.7
14.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 14.2 7.6
16.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 14.1 7.5
18.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 14.0 7.5
20.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 13.9 7.4
21.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.3 7.6 13.8 7.4
23.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.1 7.5 13.7 7.3
25.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 13.0 7.4 13.6 7.2
11.2 27.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 12.9 7.3 13.4 7.2
29.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 12.8 7.3 13.3 7.2
31.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 12.7 7.2 12.8 6.9
33.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.9 7.4 12.5 7.2 12.5 6.8
35.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.8 7.4 12.4 7.1 12.3 6.7
37.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.6 7.3 12.3 7.0 12.1 6.6
39.0 7.7 5.9 9.1 6.5 10.5 7.1 11.2 7.2 11.4 7.1 12.2 7.0 11.9 6.6
42.0 7.7 6.0 9.1 6.6 10.4 7.2 11.2 7.3 11.4 7.1 11.6 6.6 12.0 6.6
44.0 7.7 6.0 9.1 6.6 10.4 7.2 11.2 7.3 11.4 7.1 11.6 6.6 12.0 6.6
46.0 7.7 6.0 9.1 6.6 10.4 7.2 11.2 7.3 11.4 7.1 11.6 6.6 12.0 6.6
80
Ceiling & floor standing indoor units with DC fan motor
10.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 18.2 9.4
12.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 17.9 9.2
14.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 17.8 9.2
16.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 17.5 9.0
18.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 17.1 8.8
20.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 16.8 8.7
21.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.7 9.3 16.5 8.5
23.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.4 9.3 16.4 8.4
25.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.2 9.3 16.2 8.4
14.0 27.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.1 9.2 16.1 8.4
29.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 16.0 9.1 16.0 8.4
31.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 15.8 9.0 15.4 8.1
33.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.8 9.0 15.7 8.9 15.4 8.1
35.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.7 8.9 15.1 8.6 15.1 8.1
37.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.6 8.8 15.1 8.6 15.0 8.0
39.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.3 8.7 14.6 8.4 15.0 8.1
42.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.3 8.7 14.6 8.4 15.0 8.1
44.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.3 8.7 14.6 8.4 15.0 8.1
46.0 9.7 7.2 11.3 7.9 13.2 8.8 14.0 9.0 14.3 8.7 14.6 8.4 15.0 8.1
81
Ceiling & floor standing indoor units with DC fan motor
7.2 Heating
TC: total capacity
WB: wet-bulb temperature DB: dry-bulb temperature
Indoor temperature (°C DB)
Outdoor temperature
Indoor Unit size 16 18 20 21 22 24
(°C)
(kW) TC TC TC TC TC TC
WB DB kW kW kW kW kW kW
-20 -19.8 2.24 2.24 2.24 2.24 2.24 2.24
-19 -18.8 2.40 2.40 2.40 2.40 2.40 2.40
-17 -16.7 2.52 2.52 2.52 2.52 2.52 2.52
-15 -14.7 2.60 2.60 2.60 2.60 2.60 2.60
-13.00 -12.60 2.68 2.68 2.68 2.68 2.68 2.68
-11.00 -10.50 2.80 2.80 2.80 2.80 2.80 2.80
-10.00 -9.50 2.92 2.92 2.92 2.92 2.92 2.92
-9.10 -8.50 3.00 3.00 3.00 3.00 3.00 3.00
-7.60 -7.00 3.04 3.04 3.04 3.04 3.04 3.04
3.6 -5.60 -5.00 3.16 3.16 3.16 3.16 3.16 3.16
-3.70 -3.00 3.32 3.32 3.32 3.32 3.32 3.32
-0.70 0.00 3.56 3.56 3.56 3.56 3.56 3.36
2.20 3.00 3.76 3.76 3.76 3.76 3.68 3.36
4.10 5.00 3.88 3.88 3.88 3.88 3.68 3.36
6.00 7.00 4.00 4.00 4.00 3.88 3.68 3.36
7.90 9.00 4.12 4.12 4.00 3.88 3.68 3.36
9.80 11.00 4.24 4.24 4.00 3.88 3.68 3.36
11.80 13.00 4.40 4.32 4.00 3.88 3.68 3.36
13.70 15.00 4.52 4.32 4.00 3.88 3.68 3.36
-20 -19.8 2.80 2.80 2.80 2.80 2.80 2.80
-19 -18.8 3.00 3.00 3.00 3.00 3.00 3.00
-17 -16.7 3.15 3.15 3.15 3.15 3.15 3.15
-15 -14.7 3.25 3.25 3.25 3.25 3.25 3.25
-13.00 -12.60 3.35 3.35 3.35 3.35 3.35 3.35
-11.00 -10.50 3.50 3.50 3.50 3.50 3.50 3.50
-10.00 -9.50 3.65 3.65 3.65 3.65 3.65 3.65
-9.10 -8.50 3.75 3.75 3.75 3.75 3.75 3.75
-7.60 -7.00 3.80 3.80 3.80 3.80 3.80 3.80
4.5 -5.60 -5.00 3.95 3.95 3.95 3.95 3.95 3.95
-3.70 -3.00 4.15 4.15 4.15 4.15 4.15 4.15
-0.70 0.00 4.45 4.45 4.45 4.45 4.45 4.20
2.20 3.00 4.70 4.70 4.70 4.70 4.60 4.20
4.10 5.00 4.85 4.85 4.85 4.85 4.60 4.20
6.00 7.00 5.00 5.00 5.00 4.85 4.60 4.20
7.90 9.00 5.15 5.15 5.00 4.85 4.60 4.20
9.80 11.00 5.30 5.30 5.00 4.85 4.60 4.20
11.80 13.00 5.50 5.40 5.00 4.85 4.60 4.20
13.70 15.00 5.65 5.40 5.00 4.85 4.60 4.20
82
Ceiling & floor standing indoor units with DC fan motor
Indoor temperature (°C DB)
Outdoor temperature
Indoor Unit size 16 18 20 21 22 24
(°C)
(kW) TC TC TC TC TC TC
WB DB kW kW kW kW kW kW
-20 -19.8 3.53 3.53 3.53 3.53 3.53 3.53
-19 -18.8 3.78 3.78 3.78 3.78 3.78 3.78
-17 -16.7 3.97 3.97 3.97 3.97 3.97 3.97
-15 -14.7 4.10 4.10 4.10 4.10 4.10 4.10
-13.00 -12.60 4.22 4.22 4.22 4.22 4.22 4.22
-11.00 -10.50 4.41 4.41 4.41 4.41 4.41 4.41
-10.00 -9.50 4.60 4.60 4.60 4.60 4.60 4.60
-9.10 -8.50 4.73 4.73 4.73 4.73 4.73 4.73
-7.60 -7.00 4.79 4.79 4.79 4.79 4.79 4.79
5.6 -5.60 -5.00 4.98 4.98 4.98 4.98 4.98 4.98
-3.70 -3.00 5.23 5.23 5.23 5.23 5.23 5.23
-0.70 0.00 5.61 5.61 5.61 5.61 5.61 5.29
2.20 3.00 5.92 5.92 5.92 5.92 5.80 5.29
4.10 5.00 6.11 6.11 6.11 6.11 5.80 5.29
6.00 7.00 6.30 6.30 6.30 6.11 5.80 5.29
7.90 9.00 6.49 6.49 6.30 6.11 5.80 5.29
9.80 11.00 6.68 6.68 6.30 6.11 5.80 5.29
11.80 13.00 6.93 6.80 6.30 6.11 5.80 5.29
13.70 15.00 7.12 6.80 6.30 6.11 5.80 5.29
-20 -19.8 4.48 4.48 4.48 4.48 4.48 4.48
-19 -18.8 4.80 4.80 4.80 4.80 4.80 4.80
-17 -16.7 5.04 5.04 5.04 5.04 5.04 5.04
-15 -14.7 5.20 5.20 5.20 5.20 5.20 5.20
-13.00 -12.60 5.36 5.36 5.36 5.36 5.36 5.36
-11.00 -10.50 5.60 5.60 5.60 5.60 5.60 5.60
-10.00 -9.50 5.84 5.84 5.84 5.84 5.84 5.84
-9.10 -8.50 6.00 6.00 6.00 6.00 6.00 6.00
-7.60 -7.00 6.08 6.08 6.08 6.08 6.08 6.08
7.1 -5.60 -5.00 6.32 6.32 6.32 6.32 6.32 6.32
-3.70 -3.00 6.64 6.64 6.64 6.64 6.64 6.64
-0.70 0.00 7.12 7.12 7.12 7.12 7.12 6.72
2.20 3.00 7.52 7.52 7.52 7.52 7.36 6.72
4.10 5.00 7.76 7.76 7.76 7.76 7.36 6.72
6.00 7.00 8.00 8.00 8.00 7.76 7.36 6.72
7.90 9.00 8.24 8.24 8.00 7.76 7.36 6.72
9.80 11.00 8.48 8.48 8.00 7.76 7.36 6.72
11.80 13.00 8.80 8.64 8.00 7.76 7.36 6.72
13.70 15.00 9.04 8.64 8.00 7.76 7.36 6.72
-20 -19.8 5.04 5.04 5.04 5.04 5.04 5.04
-19 -18.8 5.40 5.40 5.40 5.40 5.40 5.40
-17 -16.7 5.67 5.67 5.67 5.67 5.67 5.67
-15 -14.7 5.85 5.85 5.85 5.85 5.85 5.85
-13.00 -12.60 6.03 6.03 6.03 6.03 6.03 6.03
-11.00 -10.50 6.30 6.30 6.30 6.30 6.30 6.30
-10.00 -9.50 6.57 6.57 6.57 6.57 6.57 6.57
-9.10 -8.50 6.75 6.75 6.75 6.75 6.75 6.75
-7.60 -7.00 6.84 6.84 6.84 6.84 6.84 6.84
8.0 -5.60 -5.00 7.11 7.11 7.11 7.11 7.11 7.11
-3.70 -3.00 7.47 7.47 7.47 7.47 7.47 7.47
-0.70 0.00 8.01 8.01 8.01 8.01 8.01 7.56
2.20 3.00 8.46 8.46 8.46 8.46 8.28 7.56
4.10 5.00 8.73 8.73 8.73 8.73 8.28 7.56
6.00 7.00 9.00 9.00 9.00 8.73 8.28 7.56
7.90 9.00 9.27 9.27 9.00 8.73 8.28 7.56
9.80 11.00 9.54 9.54 9.00 8.73 8.28 7.56
11.80 13.00 9.90 9.72 9.00 8.73 8.28 7.56
13.70 15.00 10.17 9.72 9.00 8.73 8.28 7.56
83
Ceiling & floor standing indoor units with DC fan motor
Indoor temperature (°C DB)
Outdoor temperature
Indoor Unit size 16 18 20 21 22 24
(°C)
(kW) TC TC TC TC TC TC
WB DB kW kW kW kW kW kW
-20 -19.8 5.60 5.04 5.60 5.60 5.60 5.60
-19 -18.8 6.00 5.40 6.00 6.00 6.00 6.00
-17 -16.7 6.30 6.30 6.30 6.30 6.30 6.30
-15 -14.7 6.50 6.50 6.50 6.50 6.50 6.50
-13.00 -12.60 6.70 6.70 6.70 6.70 6.70 6.70
-11.00 -10.50 7.00 7.00 7.00 7.00 7.00 7.00
-10.00 -9.50 7.30 7.30 7.30 7.30 7.30 7.30
-9.10 -8.50 7.50 7.50 7.50 7.50 7.50 7.50
-7.60 -7.00 7.60 7.60 7.60 7.60 7.60 7.60
9.0 -5.60 -5.00 7.90 7.90 7.90 7.90 7.90 7.90
-3.70 -3.00 8.30 8.30 8.30 8.30 8.30 8.30
-0.70 0.00 8.90 8.90 8.90 8.90 8.90 8.40
2.20 3.00 9.40 9.40 9.40 9.40 9.20 8.40
4.10 5.00 9.70 9.70 9.70 9.70 9.20 8.40
6.00 7.00 10.00 10.00 10.00 9.70 9.20 8.40
7.90 9.00 10.30 10.30 10.00 9.70 9.20 8.40
9.80 11.00 10.60 10.60 10.00 9.70 9.20 8.40
11.80 13.00 11.00 10.80 10.00 9.70 9.20 8.40
13.70 15.00 11.30 10.80 10.00 9.70 9.20 8.40
-20 -19.8 6.16 6.16 6.16 6.16 6.16 6.16
-19 -18.8 6.60 6.60 6.60 6.60 6.60 6.60
-17 -16.7 6.93 6.93 6.93 6.93 6.93 6.93
-15 -14.7 7.15 7.15 7.15 7.15 7.15 7.15
-13.00 -12.60 7.37 7.37 7.37 7.37 7.37 7.37
-11.00 -10.50 7.70 7.70 7.70 7.70 7.70 7.70
-10.00 -9.50 8.03 8.03 8.03 8.03 8.03 8.03
-9.10 -8.50 8.25 8.25 8.25 8.25 8.25 8.25
-7.60 -7.00 8.36 8.36 8.36 8.36 8.36 8.36
10.0 -5.60 -5.00 8.69 8.69 8.69 8.69 8.69 8.69
-3.70 -3.00 9.13 9.13 9.13 9.13 9.13 9.13
-0.70 0.00 9.79 9.79 9.79 9.79 9.79 9.24
2.20 3.00 10.34 10.34 10.34 10.34 10.12 9.24
4.10 5.00 10.67 10.67 10.67 10.67 10.12 9.24
6.00 7.00 11.00 11.00 11.00 10.67 10.12 9.24
7.90 9.00 11.33 11.33 11.00 10.67 10.12 9.24
9.80 11.00 11.66 11.66 11.00 10.67 10.12 9.24
11.80 13.00 12.10 11.88 11.00 10.67 10.12 9.24
13.70 15.00 12.43 11.88 11.00 10.67 10.12 9.24
-20 -19.8 7.00 7.00 7.00 7.00 7.00 7.00
-19 -18.8 7.50 7.50 7.50 7.50 7.50 7.50
-17 -16.7 7.88 7.88 7.88 7.88 7.88 7.88
-15 -14.7 8.13 8.13 8.13 8.13 8.13 8.13
-13.00 -12.60 8.38 8.38 8.38 8.38 8.38 8.38
-11.00 -10.50 8.75 8.75 8.75 8.75 8.75 8.75
-10.00 -9.50 9.13 9.13 9.13 9.13 9.13 9.13
-9.10 -8.50 9.38 9.38 9.38 9.38 9.38 9.38
-7.60 -7.00 9.50 9.50 9.50 9.50 9.50 9.50
11.2 -5.60 -5.00 9.88 9.88 9.88 9.88 9.88 9.88
-3.70 -3.00 10.38 10.38 10.38 10.38 10.38 10.38
-0.70 0.00 11.13 11.13 11.13 11.13 11.13 10.50
2.20 3.00 11.75 11.75 11.75 11.75 11.50 10.50
4.10 5.00 12.13 12.13 12.13 12.13 11.50 10.50
6.00 7.00 12.50 12.50 12.50 12.13 11.50 10.50
7.90 9.00 12.88 12.88 12.50 12.13 11.50 10.50
9.80 11.00 13.25 13.25 12.50 12.13 11.50 10.50
11.80 13.00 13.75 13.50 12.50 12.13 11.50 10.50
13.70 15.00 14.13 13.50 12.50 12.13 11.50 10.50
84
Ceiling & floor standing indoor units with DC fan motor
Indoor temperature (°C DB)
Outdoor temperature
Indoor Unit size 16 18 20 21 22 24
(°C)
(kW) TC TC TC TC TC TC
WB DB kW kW kW kW kW kW
-20 -19.8 8.68 8.68 8.68 8.68 8.68 8.68
-19 -18.8 9.30 9.30 9.30 9.30 9.30 9.30
-17 -16.7 9.77 9.77 9.77 9.77 9.77 9.77
-15 -14.7 10.08 10.08 10.08 10.08 10.08 10.08
-13.0 -12.6 10.4 10.4 10.4 10.4 10.4 10.4
-11.0 -10.5 10.9 10.9 10.9 10.9 10.9 10.9
-10.0 -9.5 11.3 11.3 11.3 11.3 11.3 11.3
-9.1 -8.5 11.6 11.6 11.6 11.6 11.6 11.6
-7.6 -7.0 11.8 11.8 11.8 11.8 11.8 11.8
14.0 -5.6 -5.0 12.3 12.3 12.3 12.3 12.3 12.3
-3.7 -3.0 12.9 12.9 12.9 12.9 12.9 12.9
-0.7 0.0 13.8 13.8 13.8 13.8 13.8 13.0
2.2 3.0 14.6 14.6 14.6 14.6 14.3 13.0
4.1 5.0 15.0 15.0 15.0 15.0 14.3 13.0
6.0 7.0 15.5 15.5 15.5 15.0 14.3 13.0
7.9 9.0 16.0 16.0 15.5 15.0 14.3 13.0
9.8 11.0 16.4 16.4 15.5 15.0 14.3 13.0
11.8 13.0 17.1 16.7 15.5 15.0 14.3 13.0
13.7 15.0 17.5 16.7 15.5 15.0 14.3 13.0
85
Ceiling & floor standing indoor units with DC fan motor
8. Electrical Characteristics
Indoor Unit Power Supply IFM
Model
Hz Voltage Min. Max. MCA MFA KW FLA
SDV4-36FAF 50/60 220-240 198 254 0.32 5 0.020 0.15
SDV4-45FAF 50/60 220-240 198 254 0.89 5 0.080 0.72
SDV4-56FAF 50/60 220-240 198 254 0.89 5 0.080 0.72
SDV4-71FAF 50/60 220-240 198 254 0.89 5 0.080 0.72
SDV4-80FAF 50/60 220-240 198 254 1.14 5 0.100 1.14
SDV4-90FAF 50/60 220-240 198 254 1.14 5 0.100 1.14
SDV4-112FAF 50/60 220-240 198 254 1.25 5 0.055*2 0.6*2
SDV4-140FAF 50/60 220-240 198 254 1.25 5 0.055*2 0.6*2
Remark:
MCA: Min. CircuitAmps. (A)
MFA: Max. Fuse Amps. (A)
KW: Fan Motor Rated Output (kW)
FLA: Full Load Amps. (A)
IFM: Indoor Fan Motor
86
Ceiling & floor standing indoor units with DC fan motor
9. Sound Levels
9.1 Test condition
Note:
1. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
2. Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m.
87
Ceiling & floor standing indoor units with DC fan motor
9.3 Octave Band Level
SDV4-36FAF SDV4-45FAF SDV4-56FAF SDV4-71FAF
Sound pressure level dB (0dB=0.0002μ bar )
88
Ceiling & floor standing indoor units with DC fan motor
10. Accessories
Name Quantity Shape Usage
Installation manual 1 / /
Hook 2 /
Hanging arm 2 /
89
Ceiling & floor standing indoor units with DC fan motor
90
Concealed duct indoor units with DC fan motor
91
Concealed duct indoor units with DC fan motor
2. Specifications ................................................................ 95
92
Concealed duct indoor units with DC fan motor
1. Features
1.1 Compact design
Min.5mm
210mm
Ceiling
93
Concealed duct indoor units with DC fan motor
1.4.2 The display board is connected with the E-box in factory, which makes troubleshooting easier by
LED display.
SDV4-22DAF to SDV4-71DAF
SDV4-80DAF to SDV4-140DAF
1.4.3 The electrical control box is possible to remove 1m far away from the main unit, which is suitable for
the small space hard to maintain. (It should be required by client in advance. Contact supplier for help)
1.4.4 The EXV is fixed inside the indoor unit, which is weld connection and convenient for installation.
1.4.5 Standard functional port such as Remote On/Off dry contact switch, and Alarm signal output
(220V).
94
Concealed duct indoor units with DC fan motor
2. Specifications
Model SDV4-22DAF SDV4-28DAF
Power supply V-Hz-Ph 220-240V~50/60Hz
Capacity kW 2.2 2.8
Cooling Input W 39 39
Rated current A 0.31 0.31
Capacity kW 2.6 3.2
Heating Input W 39 39
Rated current A 0.31 0.31
Model WZDK100-38GS WZDK100-38GS
Type DC motor DC motor
Indoor fan
Brand Pansonic/Nidec/Welling Pansonic/Nidec/Welling
motor
Input W 22 22
Speed (H/M/L) r/min 980/850/750 980/850/750
Number of rows 2 2
Tube pitch(a) × row
mm 21×13.37 21×13.37
pitch(b)
Fin spacing mm 1.5 1.5
Indoor coil Fin type Hydrophilic aluminum Hydrophilic aluminum
Tube outside diameter Ф7 Ф7
mm
and type Inner groove tube Inner groove tube
Coil length x height mm 515×147 515×147
Number of circuits 3 4
3
Indoor air flow (H/M/L) m /h 521/450/380 521/450/380
Indoor external static pressure (H) Pa 10(10~30) 10(10~30)
Indoor noise level (H/M/L) dB(A) 35/34/31 36/34/31
Dimension (W×H×D) mm 740x210x500 740x210x500
Indoor
Packing (W×H×D) mm 870×285×525 870×285×525
unit
Net/Gross weight kg 17.5/20 17.5/20
Fresh Air intake hole diameter (round) mm Ф92 Ф92
Refrigerant type R410A R410A
Type EXV EXV
Throttle
Model BD20FKS(L) BD20FKS(L)
Design pressure(H/L) MPa 4.4/2.6 4.4/2.6
Refrigerant piping Liquid / Gas mm Ф6.35 / Ф12.7 Ф6.35 / Ф12.7
2
3×2.5(L≤20m) 3×2.5(L≤20m)
Power wiring mm
Connecting wiring 3×3.5(L≤50m) 3×3.5(L≤50m)
2
Signal wiring mm 3×0.75 3×0.75
Drainage water pipe diameter mm OD Ф25 OD Ф25
Controller Wired controller KJR-29B (6 meters connection wire)
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 27°C DB/19°C WB, outdoor
temperature:35°C DB, equivalent piping: 8m (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB, outdoor temperature:
7°C DB/6°C WB, equivalent piping: 8m (horizontal).
95
Concealed duct indoor units with DC fan motor
2
3×2.5(L≤20m) 3×2.5(L≤20m)
Connecting Power wiring mm
3×3.5(L≤50m) 3×3.5(L≤50m)
wiring 2
Signal wiring mm 3×0.75 3×0.75
96
Concealed duct indoor units with DC fan motor
2
3×2.5(L≤20m) 3×2.5(L≤20m)
Connecting Power wiring mm
3×3.5(L≤50m) 3×3.5(L≤50m)
wiring 2
Signal wiring mm 3×0.75 3×0.75
97
Concealed duct indoor units with DC fan motor
2
3×2.5(L≤20m) 3×2.5(L≤20m)
Power wiring mm
Connecting wiring 3×3.5(L≤50m) 3×3.5(L≤50m)
2
Signal wiring mm 3×0.75 3×0.75
Drainage water pipe diameter OD Ф25 OD Ф25
Controller Wired controller KJR-29B (6 meters connection wire)
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 27°C DB/ 19°C WB, outdoor
temperature:35°C DB, equivalent piping: 8m (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB, outdoor temperature:
7°C DB/6°CWB, equivalent piping: 8m (horizontal).
98
Concealed duct indoor units with DC fan motor
2
3×2.5(L≤20m) 3×2.5(L≤20m)
Power wiring mm
Connecting wiring 3×3.5(L≤50m) 3×3.5(L≤50m)
2
Signal wiring mm 3×0.75 3×0.75
Drainage water pipe diameter OD Ф25 OD Ф25
Controller Wired controller KJR-29B (6 meters connection wire)
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 27°C DB/ 19°C WB, outdoor
temperature: 35°C DB, equivalent piping: 8m (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 20°C DB, outdoor temperature:
7°C DB/6°CWB, equivalent piping: 8m (horizontal).
99
Concealed duct indoor units with DC fan motor
3. Dimensions
For models: SDV4-15DAF, SDV4-22DAF, SDV4-28DAF, SDV4-36DAF
SDV4-45DAF, SDV4-56DAF, SDV4-71DAF, SDV4-80DAF, SDV4-90DAF, SDV4-112DAF, SDV4-140DAF
Outline dimension and air outlet opening size: (Unit: mm)
Air filter
Air filter
100
Concealed duct indoor units with DC fan motor
101
Concealed duct indoor units with DC fan motor
4. Service Spaces
Ensure the needed spaces for installation and maintenance.
The ceiling is horizontal and its structure can endure the weight of the indoor unit.
The outlet and the inlet are not impeded, and the influence of external air is the least.
The air flow can reach throughout the room.
The connecting pipe and drainpipe could be extracted out easily.
There is no direct radiation from heaters.
Confirm that there is enough room for installation and maintenance:
(1) Air inlet and air outlet duct should be apart far enough to prevent air outlet entering air inlet.
(2) There is dust filter on the indoor unit.
Recommended duct connection:
Canvas tie-in Canvas tie-in
Isolation booth
102
Concealed duct indoor units with DC fan motor
5. Piping Diagrams
motor
fan
T2B flare nut
gas side
T1 EXV
T2
liquid side
103
Concealed duct indoor units with DC fan motor
6. Wiring Diagrams
For models:
SDV4-15DAF, SDV4-22DAF, SDV4-28DAF, SDV4-36DAF , SDV4-45DAF, SDV4-56DAF, SDV4-71DAF,
SDV4-80DAF, SDV4-90DAF, SDV4-112DAF, SDV4-140DAF
104
Concealed duct indoor units with DC fan motor
7. Fan Performance
How to read the diagram
For static pressure dial code, please see the following Table:
Model
22-71 0 - 15Pa 10 - 25Pa 15 - 30Pa
80-90 0 - 25Pa 20 - 35Pa 30 - 50Pa
112 0 - 50Pa 40 - 70Pa 60 - 80Pa
140 0 - 50Pa 40 - 80Pa 70 - 100Pa
1.The noise is higher when ENC2 is than that when it is , and the noise is higher when ENC2 is
2.In the curve diagram for static pressure air flow volume, 2H means ENC2 is , and the fan in high
speed. 2M means ENC2 is , and the fan in medium speed. 2L means ENC2 is , and the fan in low
speed.
1H, 1M, 1L indicate the testing diagram of the fan in high, medium and low speed when ENC2 is .
0H, 0M, 0L indicate the testing diagram of the fan in high, medium and low speed when ENC2 is .
Pa 40 Pa 40
35 35
2H
30 30 2H
25 25
2M 2M
1H
20 20 1H
2L 2L
1M 1M
15 1L 15
0H 1L 0H
10 10
0M 0M
0L
5 5 0L
0 0
200 300 400 500 600 700 800 300 400 500 600 700 800 900
Model:22~28 m3/h Model:36 m3/h
105
Concealed duct indoor units with DC fan motor
Pa 40 Pa 40
35 35
2H
30 30 2H
25 2M 25
1H 2M
20 20
2L 1H
2L
15 1M 15 1M
1L 0M 0H
1L
10 10
0H
5 0L 5 0M
0L
0 0
300 400 500 600 700 800 900 1000 1100 300 400 500 600 700 800 900 1000 1100
Model:45 m3/h Model:56 m3/h
Pa 40
Pa 60
35
2H 50
30 2H
25 2M
40
1H
2M
20 30
2L 1M 1H
2L
15 20 1M
1L 0H
1L 0H
10 0M 0M
0L
10
0L
5
0
0 400 600 800 1000 1200 1400 1600 1800 2000
400 600 800 1000 1200 1400
Model:71 m3/h Model:80~90 m3/h
Pa 120
Pa 100
2H
2H 100
80
2M
1H
80
60 2M
2L 1M 60
2L 1H
40 1L 0H 40 1M
0M
20 20
1L
0H
0L
0M
0L
0 0
750 1000 1250 1500 1750 2000 2250 2500 500 1000 1500 2000 2500 3000
Model:112 m3/h Model:140 m3/h
If the external static pressure is too great (due to long extension of duct, for example), the air flow volume
may drop too low at each air outlet.
So there’s a limit air flow volume line for each speed and it is the min. airflow of this duct unit. At this flow
volume, the fan achieves the max. ESP and indoor evaporator may be protected by low temperature.
As well, there’s a limit airflow volume, which is the max. value at each speed. It requests the unit to connect
ducts for air inlet and outlet to prevent damage from the high temperature of motor/evaporator.
106
Concealed duct indoor units with DC fan motor
8. Capacity Tables
8.1 Cooling
TC: Total capacity SC: Sensible capacity WB: Wet-bulb temperature DB: Dry-bulb temperature
Indoor temperature (°C WB/DB)
Indoor Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32
Unit size temperature
(kW) (°C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.9 1.7
12.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.6
14.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.6
16.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.6
18.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.6
20.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.5
21.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.5
23.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.7 1.5
25.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.6 1.5
2.2 27.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.6 1.5
29.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.5 2.5 1.5
31.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.5 2.5 1.5
33.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.5 2.4 1.5
35.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.3 1.5 2.4 1.5
37.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.3 1.5 2.3 1.5
39.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.3 1.5
42.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.3 1.5
44.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.3 1.5
46.0 1.5 1.4 1.8 1.5 2.1 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.3 1.5
10.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 3.0 2.1 3.3 2.2 3.7 2.2
12.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 3.0 2.1 3.3 2.2 3.6 2.1
14.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 3.0 2.1 3.3 2.2 3.6 2.1
16.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 3.0 2.1 3.3 2.2 3.5 2.1
18.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 3.0 2.1 3.3 2.2 3.5 2.1
20.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 3.0 2.1 3.3 2.2 3.4 2.1
21.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 3.0 2.1 3.3 2.2 3.4 2.1
23.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 3.0 2.1 3.3 2.1 3.4 2.1
25.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 3.0 2.1 3.2 2.1 3.3 2.0
2.8 27.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 3.0 2.1 3.2 2.1 3.3 2.0
29.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 3.0 2.1 3.1 2.0 3.2 1.9
31.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 3.0 2.1 3.1 2.0 3.2 1.9
33.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 3.0 2.1 3.1 2.0 3.1 1.9
35.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 2.9 2.0 3.0 2.0 3.1 1.9
37.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 2.9 2.0 3.0 2.0 3.0 1.8
39.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 2.9 2.0 3.0 2.1 3.0 1.9
42.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 2.9 2.0 3.0 2.1 3.0 1.9
44.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 2.9 2.0 3.0 2.1 3.0 1.9
46.0 1.9 1.7 2.3 1.9 2.6 2.1 2.8 2.1 2.9 2.0 3.0 2.1 3.0 1.9
107
Concealed duct indoor units with DC fan motor
Indoor temperature (°C WB/DB)
Indoor Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32
Unit size temperature
(kW) (°C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.3 2.6 4.7 2.7
12.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.3 2.6 4.7 2.7
14.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.3 2.6 4.6 2.6
16.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.3 2.6 4.5 2.6
18.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.3 2.6 4.5 2.6
20.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.3 2.6 4.4 2.5
21.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.3 2.6 4.4 2.5
23.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.1 2.5 4.3 2.4
25.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.1 2.5 4.2 2.4
3.6 27.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.0 2.4 4.2 2.4
29.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.0 2.4 4.1 2.4
31.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.2 2.8 4.1 2.4
33.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.2 2.8 3.9 2.3
35.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.7 4.2 2.8 3.9 2.3
37.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.7 2.6 3.8 2.5 3.9 2.3
39.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.7 2.6 3.8 2.5 3.8 2.3
42.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.7 2.6 3.8 2.5 3.8 2.3
44.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.7 2.6 3.8 2.5 3.8 2.3
46.0 2.5 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.7 2.6 3.8 2.5 3.8 2.3
10.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 5.3 3.7 5.9 3.3
12.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 5.3 3.7 5.9 3.3
14.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 5.3 3.7 5.8 3.3
16.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 5.3 3.7 5.6 3.2
18.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 5.3 3.7 5.7 3.3
20.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 5.3 3.7 5.7 3.3
21.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 5.3 3.7 5.6 3.3
23.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 5.3 3.7 5.5 3.2
25.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 5.2 3.3 5.4 3.2
4.5 27.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 5.1 3.2 5.2 3.0
29.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 5.1 3.2 5.2 3.0
31.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 5.0 3.1 5.1 2.9
33.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 4.9 3.1 5.1 2.9
35.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 4.8 3.0 5.0 2.9
37.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.8 3.2 4.8 3.1 4.9 2.8
39.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.6 3.1 4.7 3.1 4.8 2.8
41.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.6 3.1 4.7 3.1 4.8 2.8
43.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.6 3.1 4.7 3.1 4.8 2.8
45.0 3.1 2.6 3.7 2.8 4.2 3.1 4.5 3.2 4.6 3.1 4.7 3.1 4.8 2.8
10.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.6 3.9 7.3 3.9
12.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.6 3.9 7.2 3.8
14.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.6 3.9 7.1 3.8
16.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.6 3.9 7.0 3.7
18.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.6 3.9 6.8 3.7
20.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.6 3.9 6.7 3.6
21.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.6 3.9 6.6 3.6
23.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.6 3.9 6.6 3.5
25.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.6 3.9 6.5 3.5
5.6 27.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.4 3.8 6.4 3.5
29.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.3 3.8 6.4 3.6
31.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.2 3.7 6.2 3.4
33.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.2 3.7 6.2 3.4
35.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 6.0 3.6 6.0 3.4
37.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.9 3.8 5.9 3.5 6.0 3.4
39.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.7 3.7 5.8 3.5 6.0 3.4
41.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.7 3.7 5.8 3.5 6.0 3.4
43.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.7 3.7 5.8 3.5 6.0 3.4
45.0 3.9 3.0 4.6 3.3 5.3 3.6 5.6 3.7 5.7 3.7 5.8 3.5 6.0 3.4
108
Concealed duct indoor units with DC fan motor
Indoor temperature (°C WB/DB)
Indoor Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32
Unit size temperature
(kW) (°C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 8.4 4.9 9.2 5.0
12.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 8.4 4.9 9.1 4.9
14.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 8.4 4.9 9.0 4.9
16.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 8.4 4.9 8.9 4.8
18.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 8.4 4.9 8.7 4.7
20.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 8.4 4.9 8.5 4.6
21.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 8.4 4.9 8.4 4.5
23.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 8.4 4.9 8.3 4.5
25.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 8.4 4.9 8.2 4.4
7.1 27.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 8.1 4.7 8.2 4.5
29.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 8.0 4.7 8.1 4.5
31.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 7.9 4.6 7.8 4.3
33.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 7.8 4.6 7.8 4.3
35.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.5 4.8 7.6 4.5 7.7 4.2
37.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.4 4.8 7.5 4.5 7.6 4.3
39.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.2 4.7 7.4 4.4 7.6 4.3
42.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.2 4.7 7.4 4.4 7.6 4.3
44.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.2 4.7 7.4 4.4 7.6 4.3
46.0 4.9 3.9 5.8 4.3 6.7 4.7 7.1 4.9 7.2 4.7 7.4 4.4 7.6 4.3
10.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.1 9.4 4.6 10.4 5.6
12.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.1 9.4 4.6 10.2 5.5
14.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.1 9.4 4.6 10.2 5.5
16.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.1 9.4 4.6 10.0 5.4
18.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.1 9.4 4.6 9.8 5.3
20.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.1 9.4 4.6 9.6 5.2
21.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.1 9.4 4.6 9.4 5.1
23.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.1 9.4 4.6 9.4 5.1
25.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.1 9.4 4.6 9.3 5.0
8.0 27.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.1 9.1 4.6 9.2 5.1
29.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.2 9.0 4.7 9.1 5.0
31.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.2 8.9 4.7 8.8 4.8
33.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.2 8.8 4.7 8.8 4.8
35.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.4 5.2 8.6 4.7 8.6 4.8
37.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.3 5.2 8.4 4.8 8.6 4.9
39.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.1 5.2 8.3 4.8 8.6 4.9
42.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.1 5.2 8.3 4.8 8.6 4.9
44.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.1 5.2 8.3 4.8 8.6 4.9
46.0 5.5 6.4 6.6 5.9 7.5 5.6 8.0 5.5 8.1 5.2 8.3 4.8 8.6 4.9
10.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.6 6.5 10.6 6.6 11.7 6.6
12.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.6 6.5 10.6 6.6 11.5 6.5
14.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.6 6.5 10.6 6.6 11.4 6.4
16.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.6 6.5 10.6 6.6 11.3 6.3
18.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.6 6.5 10.6 6.6 11.0 6.3
20.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.6 6.5 10.6 6.6 10.8 6.2
21.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.6 6.5 10.6 6.6 10.6 6.1
23.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.6 6.5 10.6 6.6 10.5 6.0
25.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.6 6.5 10.6 6.6 10.4 6.0
9.0 27.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.6 6.5 10.3 6.4 10.4 5.9
29.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.6 6.5 10.1 6.2 10.3 5.8
31.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.6 6.5 10.0 6.2 9.9 5.7
33.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.6 6.5 9.9 6.1 9.9 5.7
35.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.5 6.5 9.6 6.0 9.7 5.7
37.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.3 6.3 9.5 5.9 9.6 5.8
39.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.2 6.2 9.4 5.8 9.6 5.8
42.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.2 6.2 9.4 5.8 9.6 5.8
44.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.2 6.2 9.4 5.8 9.6 5.8
46.0 6.2 5.3 7.3 5.8 8.4 6.3 9.0 6.4 9.2 6.2 9.4 5.8 9.6 5.8
109
Concealed duct indoor units with DC fan motor
Indoor temperature (°C WB/DB)
Indoor Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32
Unit size temperature
(kW) (°C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.9 8.1 13.3 8.3 15.5 9.0
12.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.9 8.1 13.3 8.3 14.4 8.4
14.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.9 8.1 13.3 8.3 14.2 8.2
16.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.9 8.1 13.3 8.3 14.1 8.2
18.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.9 8.1 13.3 8.3 14.0 8.1
20.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.9 8.1 13.3 8.3 13.9 8.1
21.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.9 8.1 13.3 8.3 13.8 8.0
23.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.9 8.1 13.1 8.1 13.7 7.9
25.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.9 8.1 13.0 8.1 13.6 7.9
11.2 27.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.9 8.1 12.9 8.0 13.4 7.8
29.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.9 8.1 12.8 7.9 13.3 7.9
31.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.9 8.1 12.7 7.8 12.8 7.5
33.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.9 8.1 12.5 7.8 12.5 7.4
35.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.8 8.0 12.4 7.7 12.3 7.3
37.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.6 7.9 12.3 7.6 12.1 7.1
39.0 7.7 6.4 9.1 7.1 10.5 7.7 11.2 7.8 11.4 7.8 12.2 7.6 11.9 7.1
42.0 7.7 6.6 9.1 7.2 10.4 7.8 11.2 8.0 11.4 7.8 11.6 7.2 12.0 7.2
44.0 7.7 6.6 9.1 7.2 10.4 7.8 11.2 8.0 11.4 7.8 11.6 7.2 12.0 7.2
46.0 7.7 6.6 9.1 7.2 10.4 7.8 11.2 8.0 11.4 7.8 11.6 7.2 12.0 7.2
10.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.8 9.8 16.7 10.2 18.2 10.2
12.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.8 9.8 16.7 10.2 17.9 10.0
14.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.8 9.8 16.7 10.2 17.8 10.0
16.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.8 9.8 16.7 10.2 17.5 9.8
18.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.8 9.8 16.7 10.2 17.1 9.6
20.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.8 9.8 16.7 10.2 16.8 9.4
21.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.8 9.8 16.7 10.2 16.5 9.3
23.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.8 9.8 16.4 10.2 16.4 9.2
25.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.8 9.8 16.2 10.1 16.2 9.1
14.0 27.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.8 9.8 16.1 10.0 16.1 9.2
29.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.8 9.8 16.0 9.9 16.0 9.1
31.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.8 9.8 15.8 9.8 15.4 8.8
33.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.8 9.8 15.7 9.7 15.4 8.8
35.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.7 9.7 15.1 9.4 15.1 8.8
37.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.6 9.6 15.1 9.4 15.0 8.7
39.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.3 9.4 14.6 9.2 15.0 8.8
42.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.3 9.4 14.6 9.2 15.0 8.8
44.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.3 9.4 14.6 9.2 15.0 8.8
46.0 9.7 7.8 11.3 8.6 13.2 9.6 14.0 9.8 14.3 9.4 14.6 9.2 15.0 8.8
110
Concealed duct indoor units with DC fan motor
8.2 Heating
TC: Total capacity WB: Wet-bulb temperature DB: Dry-bulb temperature
Indoor temperature (℃ DB)
Outdoor temperature
Indoor Unit size 16 18 20 21 22 24
(℃)
(kW) TC TC TC TC TC TC
WB DB kW kW kW kW kW kW
-20.00 -19.80 1.46 1.46 1.46 1.46 1.46 1.46
-19.00 -18.80 1.56 1.56 1.56 1.56 1.56 1.56
-17.00 -16.70 1.64 1.64 1.64 1.64 1.64 1.64
-15.00 -14.70 1.69 1.69 1.69 1.69 1.69 1.69
-13.00 -12.60 1.79 1.79 1.79 1.79 1.79 1.79
-11.00 -10.50 1.82 1.85 1.85 1.85 1.85 1.85
-10.00 -9.50 1.90 1.90 1.90 1.90 1.90 1.90
-9.10 -8.50 1.95 1.95 1.95 1.95 1.95 1.95
-7.60 -7.00 1.98 1.98 1.98 1.98 1.98 1.98
2.2 -5.60 -5.00 2.05 2.05 2.05 2.05 2.05 2.05
-3.70 -3.00 2.16 2.16 2.16 2.16 2.16 2.16
-0.70 0.00 2.31 2.31 2.31 2.31 2.31 2.18
2.20 3.00 2.44 2.44 2.44 2.44 2.39 2.18
4.10 5.00 2.52 2.52 2.52 2.52 2.39 2.18
6.00 7.00 2.60 2.60 2.60 2.52 2.39 2.18
7.90 9.00 2.68 2.68 2.60 2.52 2.39 2.18
9.80 11.00 2.76 2.76 2.60 2.52 2.39 2.18
11.80 13.00 2.86 2.81 2.60 2.52 2.39 2.18
13.70 15.00 2.94 2.81 2.60 2.52 2.39 2.18
-20.00 -19.80 1.79 1.79 1.79 1.79 1.79 1.79
-19.00 -18.80 1.92 1.92 1.92 1.92 1.92 1.92
-17.00 -16.70 2.02 2.02 2.02 2.02 2.02 2.02
-15.00 -14.70 2.02 2.02 2.02 2.02 2.02 2.02
-13.00 -12.60 2.14 2.14 2.14 2.14 2.14 2.14
-11.00 -10.50 2.24 2.24 2.24 2.24 2.24 2.24
-10.00 -9.50 2.34 2.34 2.34 2.34 2.34 2.34
-9.10 -8.50 2.40 2.40 2.40 2.40 2.40 2.40
-7.60 -7.00 2.43 2.43 2.43 2.43 2.43 2.43
2.8 -5.60 -5.00 2.53 2.53 2.53 2.53 2.53 2.53
-3.70 -3.00 2.66 2.66 2.66 2.66 2.66 2.66
-0.70 0.00 2.85 2.85 2.85 2.85 2.85 2.69
2.20 3.00 3.01 3.01 3.01 3.01 2.94 2.69
4.10 5.00 3.10 3.10 3.10 3.10 2.94 2.69
6.00 7.00 3.20 3.20 3.20 3.10 2.94 2.69
7.90 9.00 3.30 3.30 3.20 3.10 2.94 2.69
9.80 11.00 3.39 3.39 3.20 3.10 2.94 2.69
11.80 13.00 3.52 3.46 3.20 3.10 2.94 2.69
13.70 15.00 3.62 3.46 3.20 3.10 2.94 2.69
-20.00 -19.80 2.24 2.24 2.24 2.24 2.24 2.24
-19.00 -18.80 2.40 2.40 2.40 2.40 2.40 2.4
-17.00 -16.70 2.52 2.52 2.52 2.52 2.52 2.52
-15.00 -14.70 2.60 2.60 2.60 2.60 2.60 2.60
-13.00 -12.60 2.68 2.68 2.68 2.68 2.68 2.68
-11.00 -10.50 2.80 2.80 2.80 2.80 2.80 2.80
-10.00 -9.50 2.92 2.92 2.92 2.92 2.92 2.92
-9.10 -8.50 3.00 3.00 3.00 3.00 3.00 3.00
-7.60 -7.00 3.04 3.04 3.04 3.04 3.04 3.04
3.6 -5.60 -5.00 3.16 3.16 3.16 3.16 3.16 3.16
-3.70 -3.00 3.32 3.32 3.32 3.32 3.32 3.32
-0.70 0.00 3.56 3.56 3.56 3.56 3.56 3.36
2.20 3.00 3.76 3.76 3.76 3.76 3.68 3.36
4.10 5.00 3.88 3.88 3.88 3.88 3.68 3.36
6.00 7.00 4.00 4.00 4.00 3.88 3.68 3.36
7.90 9.00 4.12 4.12 4.00 3.88 3.68 3.36
9.80 11.00 4.24 4.24 4.00 3.88 3.68 3.36
11.80 13.00 4.4 4.32 4.00 3.88 3.68 3.36
13.70 15.00 4.52 4.32 4.00 3.88 3.68 3.36
111
Concealed duct indoor units with DC fan motor
Indoor temperature (℃ DB)
Outdoor temperature
Indoor Unit size 16 18 20 21 22 24
(℃)
(kW) TC TC TC TC TC TC
WB DB kW kW kW kW kW kW
-20.00 -19.80 2.80 2.80 2.80 2.80 2.80 2.80
-19.00 -18.80 3.00 3.00 3.00 3.00 3.00 3.00
-17.00 -16.70 3.15 3.15 3.15 3.15 3.15 3.15
-15.00 -14.70 3.25 3.25 3.25 3.25 3.25 3.25
-13.00 -12.60 3.45 3.45 3.45 3.45 3.45 3.45
-11.00 -10.50 3.50 3.55 3.55 3.55 3.55 3.55
-10.00 -9.50 3.65 3.65 3.65 3.65 3.65 3.65
-9.10 -8.50 3.75 3.75 3.75 3.75 3.75 3.75
-7.60 -7.00 3.80 3.80 3.80 3.80 3.80 3.80
4.5 -5.60 -5.00 3.95 3.95 3.95 3.95 3.95 3.95
-3.70 -3.00 4.15 4.15 4.15 4.15 4.15 4.15
-0.70 0.00 4.45 4.45 4.45 4.45 4.45 4.20
2.20 3.00 4.70 4.70 4.70 4.70 4.60 4.20
4.10 5.00 4.85 4.85 4.85 4.85 4.60 4.20
6.00 7.00 5.00 5.00 5.00 4.85 4.60 4.20
7.90 9.00 5.15 5.15 5.00 4.85 4.60 4.20
9.80 11.00 5.30 5.30 5.00 4.85 4.60 4.20
11.80 13.00 5.50 5.40 5.00 4.85 4.60 4.20
13.70 15.00 5.65 5.40 5.00 4.85 4.60 4.20
-20.00 -19.80 3.53 3.53 3.53 3.53 3.53 3.53
-19.00 -18.80 3.78 3.78 3.78 3.78 3.78 3.78
-17.00 -16.70 3.97 3.97 3.97 3.97 3.97 3.97
-15.00 -14.70 4.10 4.10 4.10 4.10 4.10 4.10
-13.00 -12.60 4.35 4.35 4.35 4.35 4.35 4.35
-11.00 -10.50 4.41 4.47 4.47 4.47 4.47 4.47
-10.00 -9.50 4.60 4.60 4.60 4.60 4.60 4.60
-9.10 -8.50 4.73 4.73 4.73 4.73 4.73 4.73
-7.60 -7.00 4.79 4.79 4.79 4.79 4.79 4.79
5.6 -5.60 -5.00 4.98 4.98 4.98 4.98 4.98 4.98
-3.70 -3.00 5.23 5.23 5.23 5.23 5.23 5.23
-0.70 0.00 5.61 5.61 5.61 5.61 5.61 5.29
2.20 3.00 5.92 5.92 5.92 5.92 5.80 5.29
4.10 5.00 6.11 6.11 6.11 6.11 5.80 5.29
6.00 7.00 6.30 6.30 6.30 6.11 5.80 5.29
7.90 9.00 6.49 6.49 6.30 6.11 5.80 5.29
9.80 11.00 6.68 6.68 6.30 6.11 5.80 5.29
11.80 13.00 6.93 6.80 6.30 6.11 5.80 5.29
13.70 15.00 7.12 6.80 6.30 6.11 5.80 5.29
-20.00 -19.80 4.48 4.48 4.48 4.48 4.48 4.48
-19.00 -18.80 4.80 4.80 4.80 4.80 4.80 4.80
-17.00 -16.70 5.04 5.04 5.04 5.04 5.04 5.04
-15.00 -14.70 5.20 5.20 5.20 5.20 5.20 5.20
-13.00 -12.60 5.36 5.36 5.36 5.36 5.36 5.36
-11.00 -10.50 5.60 5.60 5.60 5.60 5.60 5.60
-10.00 -9.50 5.84 5.84 5.84 5.84 5.84 5.84
-9.10 -8.50 6.00 6.00 6.00 6.00 6.00 6.00
-7.60 -7.00 6.08 6.08 6.08 6.08 6.08 6.08
7.1 -5.60 -5.00 6.32 6.32 6.32 6.32 6.32 6.32
-3.70 -3.00 6.64 6.64 6.64 6.64 6.64 6.64
-0.70 0.00 7.12 7.12 7.12 7.12 7.12 6.72
2.20 3.00 7.52 7.52 7.52 7.52 7.36 6.72
4.10 5.00 7.76 7.76 7.76 7.76 7.36 6.72
6.00 7.00 8.00 8.00 8.00 7.76 7.36 6.72
7.90 9.00 8.24 8.24 8.00 7.76 7.36 6.72
9.80 11.00 8.48 8.48 8.00 7.76 7.36 6.72
11.80 13.00 8.8 8.64 8.00 7.76 7.36 6.72
13.70 15.00 9.04 8.64 8.00 7.76 7.36 6.72
112
Concealed duct indoor units with DC fan motor
Indoor temperature (℃ DB)
Outdoor temperature
Indoor Unit size 16 18 20 21 22 24
(℃)
(kW) TC TC TC TC TC TC
WB DB kW kW kW kW kW kW
-20 -19.8 5.04 5.04 5.04 5.04 5.04 5.04
-19 -18.8 5.40 5.40 5.40 5.40 5.40 5.40
-17 -16.7 5.67 5.67 5.67 5.67 5.67 5.67
-15 -14.7 5.85 5.85 5.85 5.85 5.85 5.85
-13.00 -12.60 6.21 6.21 6.21 6.21 6.21 6.21
-11.00 -10.50 6.30 6.39 6.39 6.39 6.39 6.39
-10.00 -9.50 6.57 6.57 6.57 6.57 6.57 6.57
-9.10 -8.50 6.75 6.75 6.75 6.75 6.75 6.75
-7.60 -7.00 6.84 6.84 6.84 6.84 6.84 6.84
8.0 -5.60 -5.00 7.11 7.11 7.11 7.11 7.11 7.11
-3.70 -3.00 7.47 7.47 7.47 7.47 7.47 7.47
-0.70 0.00 8.01 8.01 8.01 8.01 8.01 7.56
2.20 3.00 8.46 8.46 8.46 8.46 8.28 7.56
4.10 5.00 8.73 8.73 8.73 8.73 8.28 7.56
6.00 7.00 9.00 9.00 9.00 8.73 8.28 7.56
7.90 9.00 9.27 9.27 9.00 8.73 8.28 7.56
9.80 11.00 9.54 9.54 9.00 8.73 8.28 7.56
11.80 13.00 9.90 9.72 9.00 8.73 8.28 7.56
13.70 15.00 10.17 9.72 9.00 8.73 8.28 7.56
-20 -19.8 5.60 5.60 5.60 5.60 5.60 5.60
-19 -18.8 6.00 6.00 6.00 6.00 6.00 6.00
-17 -16.7 6.30 6.30 6.30 6.30 6.30 6.30
-15 -14.7 6.50 6.50 6.50 6.50 6.50 6.50
-13.00 -12.60 6.90 6.90 6.90 6.90 6.90 6.90
-11.00 -10.50 7.00 7.10 7.10 7.10 7.10 7.10
-10.00 -9.50 7.30 7.30 7.30 7.30 7.30 7.30
-9.10 -8.50 7.50 7.50 7.50 7.50 7.50 7.50
-7.60 -7.00 7.60 7.60 7.60 7.60 7.60 7.60
9.0 -5.60 -5.00 7.90 7.90 7.90 7.90 7.90 7.90
-3.70 -3.00 8.30 8.30 8.30 8.30 8.30 8.30
-0.70 0.00 8.90 8.90 8.90 8.90 8.90 8.40
2.20 3.00 9.40 9.40 9.40 9.40 9.20 8.40
4.10 5.00 9.70 9.70 9.70 9.70 9.20 8.40
6.00 7.00 10.00 10.00 10.00 9.70 9.20 8.40
7.90 9.00 10.30 10.30 10.00 9.70 9.20 8.40
9.80 11.00 10.60 10.60 10.00 9.70 9.20 8.40
11.80 13.00 11.00 10.80 10.00 9.70 9.20 8.40
13.70 15.00 11.30 10.80 10.00 9.70 9.20 8.40
-20 -19.8 7.00 7.00 7.00 7.00 7.00 7.00
-19 -18.8 7.50 7.50 7.50 7.50 7.50 7.50
-17 -16.7 7.88 7.88 7.88 7.88 7.88 7.88
-15 -14.7 8.13 8.13 8.13 8.13 8.13 8.13
-13.00 -12.60 8.63 8.63 8.63 8.63 8.63 8.63
-11.00 -10.50 8.75 8.88 8.88 8.88 8.88 8.88
-10.00 -9.50 9.13 9.13 9.13 9.13 9.13 9.13
-9.10 -8.50 9.38 9.38 9.38 9.38 9.38 9.38
-7.60 -7.00 9.50 9.50 9.50 9.50 9.50 9.50
11.2 -5.60 -5.00 9.88 9.88 9.88 9.88 9.88 9.88
-3.70 -3.00 10.38 10.38 10.38 10.38 10.38 10.38
-0.70 0.00 11.13 11.13 11.13 11.13 11.13 10.50
2.20 3.00 11.75 11.75 11.75 11.75 11.50 10.50
4.10 5.00 12.13 12.13 12.13 12.13 11.50 10.50
6.00 7.00 12.50 12.50 12.50 12.13 11.50 10.50
7.90 9.00 12.88 12.88 12.50 12.13 11.50 10.50
9.80 11.00 13.25 13.25 12.50 12.13 11.50 10.50
11.80 13.00 13.75 13.50 12.50 12.13 11.50 10.50
13.70 15.00 14.13 13.50 12.50 12.13 11.50 10.50
113
Concealed duct indoor units with DC fan motor
Indoor temperature (℃ DB)
Outdoor temperature
Indoor Unit size 16 18 20 21 22 24
(℃)
(kW) TC TC TC TC TC TC
WB DB kW kW kW kW kW kW
-20 -19.8 8.68 8.68 8.68 8.68 8.68 8.68
-19 -18.8 9.30 9.30 9.30 9.30 9.30 9.30
-17 -16.7 9.77 9.77 9.77 9.77 9.77 9.77
-15 -14.7 10.08 10.08 10.08 10.08 10.08 10.08
-13.00 -12.60 10.70 10.70 10.70 10.70 10.70 10.70
-11.00 -10.50 10.85 11.01 11.01 11.01 11.01 11.01
-10.00 -9.50 11.32 11.32 11.32 11.32 11.32 11.32
-9.10 -8.50 11.63 11.63 11.63 11.63 11.63 11.63
-7.60 -7.00 11.78 11.78 11.78 11.78 11.78 11.78
14.0 -5.60 -5.00 12.25 12.25 12.25 12.25 12.25 12.25
-3.70 -3.00 12.87 12.87 12.87 12.87 12.87 12.87
-0.70 0.00 13.80 13.80 13.80 13.80 13.80 13.02
2.20 3.00 14.57 14.57 14.57 14.57 14.26 13.02
4.10 5.00 15.04 15.04 15.04 15.04 14.26 13.02
6.00 7.00 15.50 15.50 15.50 15.04 14.26 13.02
7.90 9.00 15.97 15.97 15.50 15.04 14.26 13.02
9.80 11.00 16.43 16.43 15.50 15.04 14.26 13.02
11.80 13.00 17.05 16.74 15.50 15.04 14.26 13.02
13.70 15.00 17.52 16.74 15.50 15.04 14.26 13.02
114
Concealed duct indoor units with DC fan motor
9. Electrical Characteristics
Indoor Unit Power Supply IFM
Model
Hz Voltage Min. Max. MCA MFA KW FLA
SDV4-22DAF 50/60 220-240 187 264 0.375 15 0.017 0.3
SDV4-28DAF 50/60 220-240 187 264 0.375 15 0.017 0.3
SDV4-36DAF 50/60 220-240 187 264 0.375 15 0.02 0.3
SDV4-45DAF 50/60 220-240 187 264 0.5 15 0.028 0.4
SDV4-56DAF 50/60 220-240 187 264 0.5 15 0.034 0.4
SDV4-71DAF 50/60 220-240 187 264 0.5 15 0.034 0.4
SDV4-80DAF 50/60 220-240 187 264 0.75 15 0.048 0.6
SDV4-90DAF 50/60 220-240 187 264 0.75 15 0.048 0.6
SDV4-112DAF 50/60 220-240 187 264 1.75 15 0.135 1.4
SDV4-140DAF 50/60 220-240 187 264 1.125 15 0.113 0.9
Remark:
MCA: Min. Current Amps. (A)
MFA: Max. Fuse Amps. (A)
KW: Fan Motor Rated Output (kW)
FLA: Full Load Amps. (A)
IFM:Indoor Fan Motor
115
Concealed duct indoor units with DC fan motor
116
Concealed duct indoor units with DC fan motor
SDV4-45DAF, SDV4-56DAF SDV4-71DAF
Audibility limits of
Audibility limits of
continuous white
continuous white
sound
sound
Audibility limits of
Audibility limits of continuous white
continuous white sound
sound
SDV4-140DAF
Sound pressure level dB (0dB=0.0002μ bar)
Audibility limits of
continuous white
sound
117
Concealed duct indoor units with DC fan motor
11. Accessories
11.1 Standard accessories
For models: SDV4-15DAF, SDV4-22DAF, SDV4-28DAF, SDV4-36DAF, SDV4-45DAF,
SDV4-56DAF,SDV4-71DAF, SDV4-80DAF, SDV4-90DAF, SDV4-112DAF, SDV4-140DAF
Name Quantity Shape Usage
118
NOTE CONCERNING PROTECTION OF
ENVIRONMENT
This product must not be disposed of via normal household waste after its service life, but must be
taken to a collection station for the recycling of electrical and electronic devices. The symbol on the
product, the operating instructions or the packaging indicate such disposal procedures. The materials
are recyclable in accordance with their respective symbols. By means of re-use, material recycling or
any other form of recycling old appliances you are making an important contribution to the protection
of our environment. Please ask your local council where your nearest disposal station is located.
In case of quality problem or other please contact your local supplier or authorized service center.
Emergency number: 112
PRODUCER
SINCLAIR CORPORATION Ltd.
1-4 Argyll St.
LONDON
W1F 7LD
United Kingdom
www.sinclair-world.com
This product was manufactured in China (Made in China).
www.sinclair-solutions.com
info@sinclair-solutions.com