Chengdu Ebyte Electronic Technology Co., Ltd.

E78-900M22S User manual

Carbon Monoxide Module


(TTL serial port type)

SM-CO-P01
Ver 2.1

Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd. 1


Chengdu Ebyte Electronic Technology Co.,Ltd. SM-CO-P01 User Manual

CONTENTS
Disclaimer..............................................................................................................................................................................3
1. Product Overview............................................................................................................................................................. 4
1.1 Brief Introduction...................................................................................................................................................... 4
1.2 Feature....................................................................................................................................................................... 4
1.3 Main parameters........................................................................................................................................................ 4
1.4 System Frame Diagram............................................................................................................................................. 7
1.5 Product selection....................................................................................................................................................... 7
2. Configuration software installation and use.................................................................................................................. 8
2.1 Sensor connected to computer...................................................................................................................................8
2.2 Use of Sensor Monitoring Software.......................................................................................................................... 8
3. Communication protocol..................................................................................................................................................9
3.1 Communication basic parameters..............................................................................................................................9
3.2 Data Frame Format Definition.................................................................................................................................. 9
3.3 register address........................................................................................................................................................ 10
3.4 Communication protocol example and explanation................................................................................................ 11
4. Notice............................................................................................................................................................................... 12
About us...............................................................................................................................................................................12

Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd. 2


Chengdu Ebyte Electronic Technology Co., Ltd. E78-900M22S User manual

Disclaimer

EBYTE reserves all rights to this document and the information contained herein.

Products, names, logos and designs described herein may in whole or in part be

subject to intellectual property rights. Reproduction, use, modification or disclosure to

third parties of this document or any part thereof without the express permission of

EBYTE is strictly prohibited.

The information contained herein is provided “as is” and EBYTE assumes no

liability for the use of the information. No warranty, either express or implied, is given,

including but not limited, with respect to the accuracy, correctness, reliability and

fitness for a particular purpose of the information. This document may be revised by

EBYTE at any time. For most recent documents, visit www.ebyte.com.

Note:

The contents of this manual are subject to change due to product version upgrades

or other reasons.Chengdu Ebyte Electronic Technology Co.,Ltd. reserves the right to

make changes to the contents of this manual without notice or suggestion.This manual

serves only as a user guide and Chengdu Ebyte Electronic Technology Co.,Ltd.

endeavours to provide accurate information in this manual, but Chengdu Billionaire

Electronics Co., Ltd. does not ensure that the contents are completely error-free and

that all statements, information and suggestions in this manual do not constitute any

express or implied warranty.

Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd. 3


Chengdu Ebyte Electronic Technology Co.,Ltd. SM-CO-P01 User Manual

1. Product Overview

1.1 Brief Introduction

This module is widely used in the whole machine development of household gas leakage alarm and gas leakage
detection components. The input power supply, induction probe and signal output in the sensor are completely isolated.
Safe and reliable, small size, easy to install.

1.2 Feature

This product adopts high-sensitivity electrochemical probe with stable signal and high precision. It has the
characteristics of wide measurement range, fast response speed, convenient use and easy installation. In particular, it has
the basic functions of a household gas leakage alarm, and only needs external status indication, buzzer, relay, and
solenoid valve to achieve the function of a household gas leakage alarm that meets the national standard.

1.3 Main parameters

detect gas carbon monoxide (gas)


sensor type Electrochemistry
Interface Type 8pin and 7pin 2.0mm header
Signal output TTL serial port (Modbus-RTU
protocol)
Response time ≤30 s
Recovery ≤30 s
Time
Operating DC 4.8V~5.3V
Voltage
Working ≤5mA
current
Measurement 0~10000PPM
range
Resolution 1PPM
Alarm value Can be set (default 150PPM)
precision ±50PPM
(when the concentration is 150PPM)
life expectancy 10 Year
follow the National standard GB 15322.2
standard
Use Temperature: -10 ~ 55 ℃
environment Humidity: 20% ~ 90% RH

Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd. 4


Chengdu Ebyte Electronic Technology Co.,Ltd. SM-CO-P01 User Manual

storage Temperature: -20 ~ 60 ℃


environment Humidity: 20% ~ 65% RH
Dimensions 40mm×25mm×24mm

Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd. 5


Chengdu Ebyte Electronic Technology Co., Ltd. E78-900M22S User manual

Pin function description


pin number definitio Function Description
n
1 VCC 5V module power input
2 GND reference place
3 CTL1 Control output 1:
1. Continuously low level when there is no alarm or fault.
2. In the alarm state, the continuous high level.
4 RXD Serial port RXD data receiving pin
5 TXD Serial port TXD data transmission pin
6 CTL2 Control output 2:
1. Continuously low level when there is no alarm or fault.
2. In the alarm state, the continuous high level.
7 CTL3 Control output 3, buzzer control: high level beep
8 CTL4 Control output 4, fault light control: high level on, low level off
9 VDD Module 3.3V output, output current <100mA
10 IO1 Alarm light control port: high level on, low level off
11 IO2 Power light control port: high level on, low level off
12 IO3 Self-test key input port: low level key is valid
13 IO4 NC (keep floating)
14 IO5 NC (keep floating)
15 IO6 NC (keep floating)

Introduction to work status


1. Power-on self-test
When the power is turned on, the three lights are turned on in turn. After a delay of about 5 minutes, the buzzer will beep
once and enter the normal working state, and the "power" light will flash.
2. Normal working condition
When the module is in no fault or alarm state, the "Power" light flashes. In this state, press the "self-test" button, the
module will perform acousto-optic self-test.
3. Alarm status
When there is no fault in the module and the gas concentration on site is higher than the alarm setting value, the "alarm"
light is always on, the buzzer makes a rapid sound, and a control signal is output. At this point, you can press the
"self-test" button to mute the sound.
When the gas concentration drops to within the alarm setting value, the module automatically returns to normal working
state.
4. Fault status
When the sensor fails, the "fault" light is always on, and the buzzer makes intermittent sounds.
Fault light warning light power light
Working status (recommended (recommende (recommende buzzer
yellow) d red) d green)
normal status extinguished extinguished flicker silent

Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd. 6


Chengdu Ebyte Electronic Technology Co.,Ltd. SM-CO-P01 User Manual

fault state Always bright extinguished extinguished Tweet intermittently


Alarm status extinguished Always bright extinguished Tweet intermittently
Keep tweeting 5
Self-check status running water lamp
times
"Self-check" key: Press the "Self-check" key in normal state to carry out self-check; in alarm state, press the "Self-check"
key to silence the alarm.

1.4 System Frame Diagram

Principles of application of detection components

The principle of application of the alarm

1.5 Product selection

SM- company no.

CO- Methane

P01 TTL serial communication (Modbus-RTU protocol)

Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd. 7


Chengdu Ebyte Electronic Technology Co.,Ltd. SM-CO-P01 User Manual

N01- 485 serial communication (Modbus-RTU protocol )

8 Flat card rail shell

2. Configuration software installation and use


Our company provides supporting "sensor monitoring software", which can easily use the computer to read the
parameters of the sensor, and flexibly modify the device ID and address of the sensor.
Note that there is only one sensor on the bus when using automatic acquisition by software.

2.1 Sensor connected to computer

After the sensor is correctly connected to the computer via USB to TTL and provides power, you can see the correct
COM port in the computer (check the COM port in "My Computer - Properties - Device Manager - Port").

Open the data package, select "Debugging Software"---"Parameter Configuration Software", find and open it.

If the COM port is not found in the device manager, it means that you have not installed the USB to TTL driver (included in the data
package) or the driver has not been installed correctly, please contact a technician for help.

2.2 Use of Sensor Monitoring Software

①. The configuration interface is shown in the figure. First, obtain the serial port number according to the method in Chapter 3.1 and
select the correct serial port.
②. Click the test baud rate of the software, the software will test the baud rate and address of the current device, the default baud rate
is 9600bit/s, and the default address is 0x01.
③. Modify the address and baud rate according to the needs of use, and at the same time, you can query the current functional status of
the device.
④. If the test is unsuccessful, please re-check the equipment wiring and driver installation

Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd. 8


Chengdu Ebyte Electronic Technology Co.,Ltd. SM-CO-P01 User Manual

3. Communication protocol

3.1 Communication basic parameters

coding 8 bit binary


data bits 8 bits
parity bit None
stop bit 1 person
error checking CRC (Redundant Cyclic Code)
baud rate 2400bit/s, 4800bit/s, 9600 bit/s can be set, the factory default is 9600bit/s

3.2 Data Frame Format Definition

Using Modbus-RTU communication protocol, the format is as follows:


Initial structure ≥4 bytes of time

Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd. 9


Chengdu Ebyte Electronic Technology Co.,Ltd. SM-CO-P01 User Manual

Address code = 1 byte


Function code = 1 byte
Data area = N bytes
Error check = 16-bit CRC code
Time to end structure ≥ 4 bytes
Address code: the address of the transmitter, which is unique in the communication network (factory default 0x01).
function code:
function code meaning operable register address
0x03 read register data 0x02、0x100~0x10D
0x10 write multiple registers 0x102~0x10D
Data area: The data area is the specific communication data, pay attention to the high byte of the 16bits data first!
CRC code: two-byte check code.
Host query frame structure:

register start addre register le Check code high


address code function code Check code low
ss ngth

1 Byte 1 Byte 2 Byte 2 Byte 1 Byte 1 Byte


Slave response frame structure:

address c function number of v second data a Nth data area


data area check code
ode code alid bytes rea

1 Byte 1 Byte 1 Byte 2 Byte 2 Byte 2 Byte 2 Byte

3.3 register address

register quantity meaning status data range


address
0x02 1 Gas read only 0~10000PPM
concentration
0x100 1 Device model read only 0~0xFFFF
0x101 1 Device software read only 0~0xFFFF
version
0x102 10 device name read and write 0~0xFFFF
0x10C 1 Device address read and write 0~0xFF
0x10D 1 Serial port read and write Same with Serial Port
properties Properties Register
Serial port properties:
data bits meaning
BIT15~BIT8 Parity check selection
0: No verification (factory default)

Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd. 10


Chengdu Ebyte Electronic Technology Co.,Ltd. SM-CO-P01 User Manual

1: odd parity
2: Even parity
BIT7~BIT0 Baud rate selection
0: 1200bps
1: 2400bps
2: 4800bps
3: 9600bps(Factory default)
4: 19200bps

3.4 Communication protocol example and explanation

Example 1: Read the gas concentration value of device address 0x01 Query frame (hexadecimal):

address c function co starting address Check code hi


Data length Check code low
ode de gh

0x01 0x03 0x00 0x02 0x00 0x01 0x25 0xCA

Response frame (hexadecimal):

return valid Gas concen check code


address c function cod check code
number of b tration value high
ode e low
ytes

0x01 0x03 0x02 0x00 0x03 0xF8 0x45


Gas concentration calculation:
Concentration: 0003 H (hex) = 3PPM
Example 2: Modify the device address 0x01 to 0x02
Query frame (hexadecimal):

data area w
address function starting address Data length ord
data area check code
code code Section num
ber (2*N)

0x01 0x10 0x01 0x0C 0x00 0x01 0x02 0x00 0x02 0x37 0x9D
Response frame (hexadecimal):

address c function cod starting addr check code check code


Data length
ode e ess low high

0x01 0x10 0x01 0x0C 0x00 0x01 0xC0 0x36

Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd. 11


Chengdu Ebyte Electronic Technology Co.,Ltd. SM-CO-P01 User Manual

4. Notice

1. It is forbidden to insert or unplug or touch the sensor on the module by hand.


2. It is forbidden to modify or shift the installation state of electronic components.
3.The module should avoid contact with organic solvents (including silica gel and other adhesives), coatings,
pharmaceuticals, oils and high-concentration gases.
4. The module cannot withstand excessive impact or vibration.
5. The module needs to be preheated for more than 20 minutes when it is powered on for the first time.
6. Do not use this module in systems involving personal safety.
7. Do not install the module in a strong air convection environment.
8. Do not place the module in high-concentration organic gas for a long time.

About us

Technical support: support@cdebyte.com


Documents and RF Setting download link: www.ebyte.com
Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com
-------------------------------------------------------------------------------------------------
Phone: +86 028-61399028
Web: www.ebyte.com