PARAMETERS

1 Information on this Document


This document describes the detailed parameters of the following inverter model.

⚫ HSHV385K-G01
Without the written permission of Hopewind, no organization or individual may excerpt or reproduce part or all the
contents of this document and may not redistribute it in any form.

2 GTP
HSHV385K-G01
Inverter GTP
Sl. No.
Make HOPEWIND ELECTRIC CO., LTD.
Model HSHV385K-G01
Country of manufacturing China
A Input Data
Maximum DC Input Power @
1 < 577KW
50degC
2 MPP Voltage @ 50degC 500-1500V
3 Maximum MPPT Input Current 60A
5 Number of independent MPPTs 8
6 Maximum voltage DC 1500V
7 No . of Input(No fuse) 32

8 Input Current Monitoring Yes

9 DC Disconnection Device Yes (DC switch)


B Output Data
Rated AC Output Power
1 385KW

Maximum AC Max, Active Power (Cosθ=1)


2 385kW

5 AC Voltage 800V (640~920V)


6 Power Factor 0.8leading~0.8lagging

7 Rated Frequency 50Hz/ 60 Hz

8 Rated Current 277.9A

9 Current Harmonic Distortion Less than 3% at rated power

Shenzhen Hopewind Electric CO., Ltd. All rights reserved. Information may be subject to change without notice.
C Efficiency
1 Max Efficiency 99.01%
2 Euro Efficiency 98.70%
Internal Consumption @ Full Loadand
3.85kW/3.3kW
3 50degC

4 Standby consumption <20W

5 Night time consumption <10 W


D Environment Condition
1 Application Outdoor
2 Ingress Protection IP66
3 Ambient Temperature -25 ~+60degC
4 Derating Temperature 40 degC
5 Humidity 5%~100%

6 Max Altitude 4000m(>2000m derating)

7 Cooling Method smart air cooling


8 Noise <80dB
E Mechanical Design
1 Dimensions(W*H*D) 1135x919x416mm
2 Weight <135kg
F Protection
DC Side
1 Over Voltage Protection Yes
2 Over Current Protection Yes
3 Reverse Polarity Yes
4 PID Recovery Yes
5 Negative Grounding Yes (Negative grounding insulation detection)
6 Ground Fault Monitoring Yes
7 Insulation Monitoring Yes
8 Over Heat Protection Yes
9 Surge Protection Yes
10 Short Circuit Protection Yes
11 Fan Protection Yes
AC side
12 Over / Under Voltage Protection Yes
13 Over Current Protection Yes
14 Current Balance Yes
15 Over / Under Frequency Protection Yes
16 Sequence Protection Yes (phase sequence protection)
17 Short Circuit Protection Yes
18 Surge Protection Yes
19 Earth Fault Yes
20 Synchronization loss protection Yes
Shenzhen Hopewind Electric CO., Ltd. All rights reserved. Information may be subject to change without notice.
21 Over temperature protection. Yes
23 Grid monitoring Yes
24 Current balance Yes
25 Cooling system failure Yes
G Grid Support Features
2 HVRT Yes
3 LFRT Yes
4 HFRT Yes
5 Anti-Islanding Yes
6 Active & Reactive Power Regulation Yes
7 PF Control Yes
8 Soft Shut-Down Yes

H User Interface
1 LED Yes
2 Real Time Clock Yes
3 Trends with Real Time Data Yes
4 Communication Wi-Fi / APP, RS485 / PLC
5 Fault/ Alarm History Yes
6 Remote operation and control Yes
I Connection
1 DC side Termination with cable size Copper wire :4 to 6mm²

2 3-core (A, B, C)outdoor cable, cross-sectional


AC side Termination with cable size
area:120mm²(Copper)/400mm²(Aluminium)

Shenzhen Hopewind Electric CO., Ltd. All rights reserved. Information may be subject to change without notice.