Blowout Preventer Specification & Performance Data Sheet

13-5/8" 10M Cameron Type U Double BOP


Bonnets: Upper - Standard; Lower - Large Bore & Tandem Boosters

Technical Information
Manufacturer: Cameron Hydraulic Operating Pressure: 1,500 psi Lifting Plate Capacity: 100,000 lbs

Size: 13-5/8" Max Operating Pressure: 3,000 psi Bonnet Bolt Specs

Pressure Rating: 10,000 psi Open/Close Port Size: 1.000 in Bolt Wrench: 2.250 in

Vertical Bore: 13.625 in Flange Gasket: BX-159 Bolt Lube: Moly Lube

Height: 66.630 in Outlet Size: 4-1/16" 10M Bolt Torque: 8,982 ft-lbs
Bolt Hex:
Weight: (Approximate) 26,810 lbs Outlet Gasket: BX-155 3.500 in
(Across the Flats)

Upper: 13-5/8" 10M Standard Bonnets


Bonnet Length Operating Data

Open & Unlocked: 175.54 in Gallons to Open: 5.50 Open Ratio: 2.30

Closed & Locked: 115.66 in Gallons to Close: 5.80 Close Ratio: 6.80

Lower: 13-5/8" 10M Blind Shear Rams w/ Large Bore Bonnets & Tandem Boosters
Bonnet Length Operating Data

Open & Unlocked: 220.92 in Gallons to Open: 10.50 Open Ratio: 3.70

Closed & Locked: 160.24 in Gallons to Close: 17.50 Close Ratio: 17.20

www.quailtools.com
Visit our website or download the Quail Tools Tubular & BOP Specification App for the latest updates and specifications!
The technical information contained herein, including the product Specification / Performance sheets and other attached documents, have been generated from material provided by the manufacturer where available. Field dimensions may vary. It is for reference only and
should not be construed as a recommendation. The user is fully responsible for the accuracy and suitability of use of all technical information. Quail Tools cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is
intended. The information provided for various wear conditions is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and/or end user to determine the appropriate performance ratings, acceptable use of the
product, and maintain safe operational practices.

New Iberia, LA (337) 365-8154 Victoria, TX (361) 579-0244 Odessa, TX (432) 366-1491 Evanston, WY (307) 789-5860
Texarkana, TX (903) 838-1624 Williston, ND (701) 774-2280 Morgantown, WV (304) 212-5191
Houston, TX (281) 445-1777 * Denver, CO (303) 534-1873 * Ok. City/Tulsa, OK (918) 994-4695 * Dallas, TX (972) 661-1443 * San Antonio, TX (210) 822-4801 * Pittsburgh, PA (724) 916-4643

**Uncontrolled When Printed**


Created By: KaciL QT-13.625_10M - Double_Standard_LB Boosters Generated On: 6/9/2021

You might also like