Professional Documents
Culture Documents
Non-Combustibility Apparatus
CSI-91 Brochure (Rev 1.1)
Introduction
Disclaimer: Product improvement is a continuing goal at CSI. Designs and revisions are subject to change without notice or obligation.
CSI-91 Brochure (Rev 1.1)
✓ Stainless Steel Sample Holder Assembly Computerized Data Acquisition (DAQ) System
with calibrated thermocouples per
specification for Surface and/or Center The CSI-91 Data Acquisition System is offered as
temperature measurements a standard feature. This includes the laptop,
✓ Stainless Steel Base Frame for stable data acquisition hardware and Windows 10 CSI
positioning of furnace software license. It allows the user to perform
✓ Conformance Certificate accurate and repeatable test results,
✓ Operator’s Manual and Software Manual calibration, generate test reports, and much
more.
Operator’s Control Console
The DAQ systems includes all the required data
Dedicated Control Console includes all the acquisition hardware and pre-installed and
controls required to operate the CSI-91. 1.5 kVa configured test software on a CSI supplied
power transformer, programmable Eurotherm laptop.
power controller, cooling fan and switches are
included. The 3 main functions of the software:
The power controller has a range of 0 to 600W
and safety power maximum limit to prevent ✓ Calibration
over temperature. The power controller acts as this function allows the user to set the
a voltage stabilizer and compensates for any parameters for the furnace temperature
supply voltage fluctuations and displays the stabilization and measures the furnace
power, voltage and current being supplied to thermocouple for the stabilization period.
the furnace assembly in real time. This ensures
a constant and reliable test results. ✓ Sample Testing
There is a power adjustment knob that goes This function provides all of the data storage and
from 0 – 100% (0 to 600W) to control the power acquisition, stabilization and test period timing,
output to the furnace. The furnace temperature and other associated tasks for the testing of
is displayed in the test software. materials, The operator inputs the data file
name, sample, pretest comments, and other
pertinent data. After insertion of the sample into
the furnace the user is informed of the
stabilization time, acquisition of the baseline
thermopile reading, insertion of the test sample
and progression through testing period. At the
end of the test run, the user may select to run
another test and use or modify the previous test.
Disclaimer: Product improvement is a continuing goal at CSI. Designs and revisions are subject to change without notice or obligation.
CSI-91 Brochure (Rev 1.1)
Installation Requirements
Disclaimer: Product improvement is a continuing goal at CSI. Designs and revisions are subject to change without notice or obligation.
� .::.J lnsrru111Pnrs� Inc.
,..�,®Cu5IOl115CiPnliTic
With customers worldwide and a strong network of partners and representatives, CSI is one of the premier manufacturers of high technology material
test instrumentation.
CSI has been supplying test instruments and laboratory apparatus to industries, laboratories, government agencies, and universities in this country and
abroad. The knowledge and expertise we have acquired from years of test instrument design, manufacture, and experience in the testing field is
available to serve our valued clients.
Rev 1.0/2019 / CSI and the CSI logo are registered trademarks of Custom Scientific Instruments, Inc. / Due to the CSl's continuous development policy;
technical changes could be made without prior notice.