a) Before commencing installation, make sure you read the warnings. b) In addition to the figures, you must follow the instructions given in the INSTALLATION MANUAL.
CABLE ARRANGEMENT A
ENGLISH
PILLAR FASTENINGS INSTALLATION DISTANCES.
B
GIUNO ULTRA BT A20 mm GIUNO ULTRA BT A50 mm
b a 90 100 110 125 135 145 155 165 175 b a 115 135 155 175 195 215 235 255 275
90 110 104 98 95 91 115 110 110 108 101 96 92
100 105 99 95 91 88 135 106 106 110 102 96 92
110 108 100 95 91 88 155 107 106 108 103 96 91 87
125 99 93 89 86 175 103 107 106 96 91 86
135 99 93 89 195 104 106 97 90 86
145 95 97 89 215 101 99 90 85
155 95 91 235 96 101 90 84
165 91 91 86 255 95 89 83
175 91 85 275 88
INSTALLATION DIAGRAM.
C
D
Z=b-X > 45mm
F
X
c
m
α° Kg
0 = 1040 m
N O U LT RA BT A2 2 8 5 m m
G IU = 1
RA BT A50
P
a GIUNO ULT
* *
P P **P P
1 2 3 4
*
Not provided! Accessory available in product list
POWER CABLE.
30 mm
E
H07RN-F 4x2.5mm2
5mm 0-2mm
1 4
4 3
SW
V1
3 -REF SWE 5 3,9
2 13
1
V1
OK
2 ON
KO
Wire before installation
P1 V2
Y D3
1 T2
R2
P2
1
D1
P1 44,5
D2
D3
12
T1
M8
R1 P2
P2 63,5
2
12
M8
2
P3 54,5
12
M8
D1 T1 V1
29,5 8
Ø12
30
M8
24
D3 T2 V2 R1 R2 M8 D2
10 88 8
Ø12 2,5
25
M8
13 M8
ITALIANO
MAXIMUM TILT
G
L1 L2
BT A20 79 127
L1 L2
BT A50 112 159
ENGLISH
CORRECT INSTALLATION
H
CLOSE
FRANÇAIS
P1
R1
R1
307 mm MAX
41 mm
R2
OPEN
A1
DEUTSCH
CLOSE
R1
P1 R2
65 mm
455 mm MAX
R1
A1
OPEN
NEDERLANDS
A1 P1 41 R1 R2 R3
Ø5
10 18 20
Ø9,8
Ø 0,5 2
12 10
Not provided!
Not provided!
CLOSE
B
A 2
Closing limit stop Closing slow-down
A
2
LOCKING SETTINGS L
(perform after limit switches have been set). See table 1
MAX 180°
MAX 90°
IF NECESSARY. Attention!!
Turn SLOWLY until you hear (and can touch)
ENGLISH
the mechanical stop inside mechanism!!!
1
2
V1
Locking open
2
C1
NO locking open,
C1
3
Locking closed,
2
C1
NO locking closed
3
C1
Non-locking, 2 3
C1
C1
4 C1
6
1 V1
9.5
2,9
V1
2
GIUNO ULTRA BT A20 - GIUNO ULTRA BT A50 - 7
D814076 0AA00_04
COVER POSITIONING.
M
V1
3,5
13
V2
3,5
R1 22
Left
V1 R1 3,5 1
V2
Ø 5,8 Ø 8.5
Right
Careful not to damage the limit switch wires
N
M C
P D F
65
O a P
91
b
CU 94
GIUNO ULTRA BT A 50 1450 mm
GIUNO ULTRA BT A 20 1190 mm
L2
L1
102
L1 CU L2
BT A20 776 268 1108
BT A50 883 390 1347
Q R
b
F S
SX DX
Left Right
F F
ENGLISH
R1 Ø5 R2 Ø5 V1
2,9 1 T
9.5
1
T1 269
M5
R1 2 3
R2
L
OI
V2
A1
T1
V1
max 3 Nm
34 mm BT A 20
V2
18 mm BT A 50
A1 A1
Ø1
Ø6
V2
M6
12
1) GENERAL INFORMATION Correct installation entails maintaining a rod stroke margin of approx. 10mm on
Compact and strong hydraulic piston, available in the GIUNO ULTRA BT A20 and the maximum stroke to avoid possible trouble with operation.
GIUNO ULTRA BT A50 versions.
Operating force is adjusted with extreme precision by means of the control unit’s
11) FASTENING OF FITTINGS TO LEAF Fig. I
electronic control.
12) ADJUSTING THE LIMIT SWITCHES (Fig. J-K)
2) TECHNICAL SPECIFICATIONS Position the slow-down sensors (Ref. B fig. J-K) towards the centre of the motor,
Power supply (*) 24V near the limit switch board; position the limit switch sensors (Ref. A Fig. J-K) at
the motor ends.
Max. power input 90W Enter the limit switch adjustment menu and bring the door to the desired
Max. pressure 30 bar position. To position the door you can release the motor and position it manually
or operate buttons + and – (+ Opens, - Closes). Once the door is in the desired
Pump delivery rate 1,2 l/min. position, adjust the limit switch sensor: starting from the motor end, move the
ENGLISH
Operating force 3000 N sensor towards the centre of the motor until the limit switch board LED lights
up; when the limit switch is working, the relative board LED is on, when it is not,
Pulling force 2600 N the LED is off. Adjust both the opening and closing limit switches. After adjusting
Ambient temperature range - 20°C to 60°C the limit switch position (Ref. A Fig. J-K), adjust the position of the slow-down
start (Ref. B Fig.J-K).
Type of use very intensive
Impact reaction electronic clutch (with control panel) 13) LOCKING SETTING Fig. L
Manual operation release key
14) COVER POSITIONING Fig. M
Protection rating IP 55
Actuator weight GIUNO ULTRA BT A20: 6,6 kg 15) MAIN PARTS OF AUTOMATED SYSTEM Fig. N
GIUNO ULTRA BT A50: 7,4 kg M) 24V permanent magnet motor
P) Lobe pump
Overall dimensions Fig. Q D) Control valve assembly
Oil Idrolux Winter C) Cylinder with piston
F) Limit switch sensors
Sound pressure <70dB(A) Components provided: fittings attached to pillar and gate - release key - instruction
(*) Special supply voltages to order. manual.
WARNING: With leaves over 3 metres long, the solenoid lock must be
used and locking devices must be opened (Fig. M Ref. 2)