LIGHTNING PROTECTION

SYSTEMS
TECHNICAL ADVICE BUDGET WITHOUT COMMITMENT
Resolution of doubts, queries and issues related to Contact us, tell us what you need and receive your
lightning rods, accessories and/or grounding. estimate for free without obligation.

PROJECTS TRAINING
Preparation of technical documentation for all types of Training courses and webinars for all types of
lightning protection projects. professionals in the sector.

I N S TA L L AT I O N O F E A RT H I N G S R I S K S E VA L U AT I O N
With guarantees of compliance with the UNE 21186 Determination of risk level and protection level according
standard and using high quality materials. to the UNE 21186 or CTE SU 8 standards.

TESTING C E RT I F I C AT I O N
Verification of operation, with specialized devices, of all Manufacturer certification service for any related
the elements of the installation. element.
ABOUT US

We are manufacturers of lightning


protection systems
At Aiditec Systems we are leading the innovation in each project. Each installation that our engineers work
on is carefully studied to offer an adequate solution, always taking into account the needs and possibilities
of each client.

Each product that leaves our facilities goes through different quality tests, thus ensuring the proper functioning
of all of them, following as a guide the units tested and certified by the Technological Institute of Energy (ITE),
an accredited and independent laboratory. We are constantly working on new products, constantly investing
in R+D+I, knowing that innovation is our flag and a necessity for our customers.

We have a presence in the 5 continents, but we do not stop there, we continue in continuous international
expansion, offering advice and training to universities and companies that requier it.

In addition, we actively participate as members of the standarization workgroups in the field of lightning
protection.

R + D + I

We believe in innovation and


constant reinvention
We use state-of-the-art technology and methodologies in each of our projects to ensure their effectiveness
and guarantee the safety of all our clients. Thanks to that:

• Our products are safe and effective.


• We offer solutions tailored to the needs and demands of our customers.
• We offer high quality, professional, close and personalized attention.
• Our products and services have an excellent quality/price ratio.
• we are rigorous in the fulfillment of the acquired commitments.
• We are respectful with the environment.
• We guarantee the safety of all our clients.

D E S I G N A N D M A N U FA C T U R I N G

European technology
Our products meet all the requirements established in current regulations and have been designed,
manufactured and verified according to the most demanding quality standards. In addition, all the materials
used are of spanish origin.

We have certifications of accredited bodies, official and independent to give maximum guarantees. All our
lightning rods have a lifetime warranty.
ISO 9001

Quality management systems


Aiditec Systems, S.L. is a company certified in the ISO 9001 standard by SGS, a world leader in inspection,
verification and certification services for international trade operations.

This certification guarantees that Aiditec Systems, S.L. complies with the quality according to the ISO
9001:2015 standard in all work procedures, ensuring our company’s commitment to the quality of all our
products and services. In addition, this certification helps us identify and address risks, improve performance
and operate more efficiently, as well as demonstrate high levels of service quality when applying for new
contracts and markets.

I N T E R N A C I O N A L I Z AT I O N

Protection in the 5 continents


We have a presence in the 5 continents developing complete projects against lightning and surges.

Our headquarters are in Valencia (Spain) but we operate through a network of local distributors in more than
25 countries, adapting to the needs and demands of each place.

Our distributors are highly qualified and, in addition, we offer them a support plan that includes continuous
training, technical support, sales and marketing support tools.

SERVICES

Much more than manufacturers


PROJECTS

Our engineering team is qualified to carry out lightning protection projects, analyze the situation and design
the most suitable solution to provide the most effective protection.

ADVICE

Technical advice to all types of professionals in the sector for the correct installation of protection systems
against atmospheric discharges.

TRAINING

Training courses and webinars for all types of proffesionals who want to acquire knowledge in everything
related to this sector.

ONLINE CALCULATION OF PROTECTION

We have a technical department for the development of the different protection calculations. In addition,
anyone who wants can make their own risk calculation on our website, as well as the calculation for the
selection of surge protectors.
LIGHTNING PROTECTION

Security. Reliability. Endurance.


Lightning can affect us fundamentally in two, either by direct impact or through an overvoltage, so a complete
lightning protection system is made up of two systems; one of external protection against direct impacts, and
the other of internal protection to counteract the effects produced by overvoltages.

The installation of a lightning protection system designed and installed in accordance with the standards
minimizes the consequences of lightning as much as possible. On the other hand, to keep the system in
perfect condition over time, it will be necessary to carry out periodic reviews and maintenance.

WHY SHOULD WE INSTALL A LIGHTNING PROTECTION SYSTEM?

There are different reasons for installing a lightning protection system, but they could be reduced to two
fundamentally:

1. Having a lightning protection system is the best option to protect people, animals, structures, machinery
and facilities against this natural phenomenon.
2. To comply with the norms that regulate the installation of these systems. According to these standards,
in some cases the installation will be mandatory, necssary or recommended. To determine this question,
the calculation of the risk index must be performed. Different factors are taken into account in this
calculation, but basically two are taken into account; the probability of impact and the consequences
derived from it. Among the structures in which installation of a lightning protection system will be
necessary are:
• Buildings or open areas with public attendance.
• High-rise buildings.
• Constructions or tanks in which toxic, radioactive, flammable or explosive substances are handled
or contain and ATEX areas.
• Buildings containing especially vulnerable or valuable equipment or documents.
• In general, structures used for commercial, industrial, agricultural, administrative or residential
purposes.

In addition, it should be borne in mind that insurers recommend the installation and maintenance of these
protection systems to be able to adjust the amounts of the insurance, since in this way understand that the
user is using the appropiate means to protect himself from lightning and its effects.

E A R LY S T R E A M E R E M I S S I O N

Functioning of ESE lightning rod


When a storm forms, there is an increase in atmospheric electrical potential that can exceed 10kV/meter
quickly. The ESE internal device stores this energy in the electro-atmospherical capacitor, which is formed by
the outer metal casing and the earthed shaft.

With this increase of potential, two things happen at the same time; the first is that a downwards stream
is created from the clouds to the ground, and the second is that an upward artificial stream is created by
lightning rod. This ascending stream intercepts the descending one, guiding the electric discharge through
the lightning rod and conducts it to the ground safely.

The time that the upward stream of an ESE lightning rod forward to a stream created by any passive element,
such as a Franklin rod, is what determines the radius of protection. This is what os known as advance time in
priming (∆t). Therefore, there are different ESE models with different advance times depending on the meters
of protection needed in each case.
Index
ESE LIGHTNING RODS............................................................08

ADVANCE +...................................................................................................................10
SIGMA +..............................................................................................................................12
ELECTRON E15..................................................................................................................................14

PA S I V E L I G H T N I N G R O D S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 6

ACCESSORIES......................................................................20

GROUNDING....................................................................36

MEASURING DEVICES.............................................................42

AS Tester............................................................................................................................................44
ADT Counter......................................................................................................................................46

SURGE PROTECTION DEVICES...................................................48

SPD....................................................................................................................52
SPU.....................................................................................................................59
SELF-COMPSUMPTION AND ELECTRIC VEHICLE............................................................................61
ESE LIGHTNING RODS

ESE LIGHTNING RODS

ADVANCE+
The ADVANCE+ lightning rod with priming device (ESE) is the best protection with the latest
technologies incorporated and the best guarantee of operation. This device has successfully passed
the test based on the UNE 21186, NFC 17102, and NP 4426 standards for lightning rods with a
priming device:

DIMENSIONALS
Ensures that the dimensions are normalized.

SALT FOG AND HUMID SULFUROUS ATMOSPHERE


Certifies resistance in corrosive environments.

CURRENT (200 kA - 10/350 µs)


It guarantees the operation after several impacts.

ADVANCE IN PRIMING
Guarantees the protection radius.

> NEW TECHNOLOGIES

AS a result of the research carried out and the R&D projects developed, the ADVANCE+ lightning rod
incorporates the following new technologies:

EAC - ESTABILIZATION OF ADVANCE IN PRIMING


The dual-energy block allows achieving a maximum deviation of 5% in the advance time based
on the product certification regulations.

DSF - DEIONIZATION BY FORCED BLOWING


It allows deionization by the Ventury Effect of the ionization vault, releasing a large amount of
hot air at the moment of a lightning strike, expelling the carbon produced in the deflagration.

AAA - WATER INSULATION ASSURANCE


It allows the PDC electrodes to be isolated, maintaining their potential difference at all times in
extreme rain conditions due to electron displacement. By having a dual-energy block, the load of
the main system is ensured.

AAE - ELECTRICAL ARC LENGTH


It avoids the deposition of highly conductive carbon on the PDC electrodes, maintaining its
potential difference and avoiding self-discharge of the energy block.

> TECHNICAL CHARACTERISTICS

Material Stainless steel AISI-316L


Weight 3,5 kg
Withstand current 200 KA - wave 10/350 µs
Operating temperature - 40ºC ... + 130ºC
Metric Thread M-16 x 2

10 ESE LIGHTNING RODS www.aiditecsystems.com


ESE LIGHTNING RODS

> “ISOLATED RAIN” SYSTEM

The ESE ADVANCE+ guarantees the operation of its priming device and its effectiveness in protection in
extreme rain conditions thanks to the “ISOLATED RAIN” system.

This system guarantees total isolation in adverse atmospheric conditions provided by the ELECTRODE
IONIZATION VAULT. This vault prevents the rain from putting the metal body of the lightning rod (at
atmospheric potential) in electrical contact with the metal shaft (at ground potential).

When an ESE does not have this insulation guarantee and adverse atmospheric conditions occur, such
as heavy rain, electrodes with different potentials can come into contact and cause a short circuit in the
ignition device that prevents the lightning rod from offering the necessary safety, drastically reducing
your radius of protection.

> INSTALLATION

The installation of the ESE ADVANCE+ must be carried out of following the indications of the Technical
Building Code (CTE) and standards UNE 21186, NFC 17102, and NP 4426. “Protección contra el rayo:
Pararrayos con dispositivo de cebado”.

> PRIMING ADVANCE TIMES (ΔT)

All models of the ESE ADVANCE+ have successfully passed the tests based on current regulations. The results of the laboratory test were
much higher, but by regulation, we certify the following advance times:

REF. Model ΔT Certificate


AS900101 ADVANCE+ A1 37 µs
AS900102 ADVANCE+ A2 60 µs

> PROTECTION RADIUS OF THE ESE ADVANCE+ FOR A HEIGHT OF 6 METERS IN RELATION TO THE PLANE TO BE PROTECTED

REF. Model Protection level


I II III IV
AS900101 ADVANCE+ A1 55 60 70 80
AS900102 ADVANCE+ A2 80 87 97 107

> LIFETIME WARRANTY

All ADVANCE+ ESE carry an INTERNATIONAL LIMITED LIFETIME WARRANTY against all manufacturing defects. More info about our
product warranty at: www.aiditecsystems.com/warranty

www.aiditecsystems.com ESE LIGHTNING RODS 11


ESE LIGHTNING RODS

ESE LIGHTNING RODS

SIGMA+
The ESE SIGMA+ is an incredibly effective and highly competitive premium protection system.
This device has successfully passed the tests based on the UNE 21186, NFC 17102, and NP 4426
standards for lightning rods with priming device:

DIMENSIONALS
Ensures that the dimensions are normalized.

SALT FOG AND SULFUROUS HUMID ATMOSPHERE


Certifies resistance in corrosive environments.

CURRENT (200 kA - 10/350 µs)


It guarantees the operation after several impacts.

ADVANCE IN PRIMING
Guarantees the protection radius.

> NEW TECHNOLOGIES

As a result of the research carried out and the R&D projects developed, the SIGMA+ lightning rod
incorporates the following new technologies:

EAC - STABILIZATION OF ADVANCE UN PRIMING


The dual-energy block allows achieving a maximum deviation of 5% in the advance time based
on the product certification regulations.

AAA - WATER INSULATION ASSURANCE


It allows the ESE electrodes to be isolated, maintaining their potential difference at all times in
extreme rain conditions due to electron displacement. By having a dual-energy block, the load of
the main system is ensured.

AAE - ELECTRICAL ARC LENGTH


It avoids the deposition of highly conductive carbon on the ESE electrodes, maintaining its
potential difference and avoiding self-discharge of the energy block.

> TECHNICAL CHARACTERISTICS

Material Stainless steel AISI-316L


Weight 2,2 kg
Withstand current 200 KA - wave 10/350 µs
Operating temperature - 40ºC ... + 130ºC
Metric Thread M-16 x 2

12 ESE LIGHTNING RODS www.aiditecsystems.com


ESE LIGHTNING RODS

> INSTALLATION

The installation of ESE SIGMA+ must be carried out following the indications of the Technical Building Code (CTE) and standards UNE
21186, NFC 17102, and NP 4426. “Protection against lightning: lightning rod with priming device”.

> PRIMING ADVANCE TIMES (ΔT)

All ESE SIGMA+ have successfully passed the tests based on current regulations. The results of the laboratory test were much higher, but
by regulation, we certify the following advance times:

REF. Model ΔT Certificate


AS800101 SIGMA+ S1 25 µs
AS800102 SIGMA+ S2 45 µs
AS800103 SIGMA+ S3 60 µs

> PROTECTION READIUS IN METERS FOR A HEIGHT OF 6 METERS IN RELATION TO THE PLANE TO BE PROTECTED

REF. Model Protection level


I II III IV
AS800101 SIGMA+ S1 40 50 55 65
AS800102 SIGMA+ S2 65 70 80 90
AS800103 SIGMA+ S3 80 87 97 107

> LIFETIME WARRANTY

ALL ESE SIGMA+ carry an INTERNATIONAL LIMITED LIFETIME WARRANTY against all manufacturing defects. More info about our
product warranty at: www.aiditecsystems.com/warranty

www.aiditecsystems.com ESE LIGHTNING RODS 13


ESE LIGHTNING RODS

ESE LIGHTNING RODS

ELECTRON E15
Due to its small size and incredible performance, the ELECTRON E15 lightning rod with priming
device (ESE) is perfect for protecting structures and small areas such as towers, antennas, or single-
family homes. This device has successfully passed the tests based on the UNE 21186, NFC 17102,
and NP 4426 standards for lightning rods with priming device:

DIMENSIONALS
Ensures that the dimensions are normalized.

SALT FOG AND SULFUROUS HUMID ATMOSPHERE


Certifies resistance in corrosive environments.

CURRENT (200 kA - 10/350 µs)


It guarantees the operation after several impacts.

ADVANCE IN PRIMING
Guarantees the protection radius.

> NEW TECHNOLOGIES

As a result of the research carried out and the R&D projects developed, the ESE ELECTRON E15
incorporates the following new technologies:

AAA - WATER INSULATION ASSURANCE


It allows the ESE electrodes to be isolated, maintaining their potential difference at all times in
extreme rain conditions due to electron displacement. By having a dual-energy block, the load of
the main system is ensured.

> TECHNICAL CHARACTERISTICS

Material Stainless steel AISI-316L


Weight 1,8 kg
Withstand current 200 KA - wave 10/350 µs
Operating temperature - 40ºC ... + 130ºC
Metric Thread M-16 x 2

> INSTALLATION

The installation of the ESE ELECTRON E15 must be carried out of following the indications of the
Technical Building Code (CTE) and standrds UNE 21186, NFC 17102 and NP 4426 “Protection
against lightning: lightning rod with priming device”.

14 ESE LIGTHNING ROD www.aiditecsystems.com


ESE LIGHTNING RODS

> PRIMING ADVANCE TIMES (ΔT)

The ESE ELECTRON E15 has successfully passed the tests based on current regulations. We can certify the following lead time:

REF. Model ΔT Certificate


AS800010 ELECTRON E15 15 µs

> PROTECTION RADIUS IN METERS FOR A HEIGHT OF 6 METERS IN RELATION TO THE PLAN TO BE PROTECTED

REF. Model Protection level


I II III IV
AS800010 ELECTRON E15 30 35 45 50

> LIFETIME WARRANTY

All ESE ELECTRON E15 carry an INTERNATIONAL LIMITED LIFETIME WARRANTY against all manufacturing defects. More info about
our product warranty at: www.aiditecsystems.com/warranty

FRANKLIN ROD ESE ELECTRON E15

Protected areas
Unprotected sensitive areas

www.aiditecsystems.com ESE LIGHTNING RODS 15


PASSIVE RODS

PA S S I V E R O D S

The Franklin rod is a device designed to protect buildings, structures and people against the dangerous effects of lightning. It was invented
by Benjamin Franklin in the 18th century and has been widely used ever since to prevent damage from lightning strikes from storms.

The Frranklin rod consists of several esential parts. The main piece is a conductive metal rod, generally made of cooper or stainless steel
alloys, which is installed in the highest part of the building or structure to be protected. The rod rises above the highest point of the ciling,
allowing it to draw lightning to itself.

As a thunderstorm approaches, the electric and magnetic fields generated by atmospheric charges cause the pointed end of the lightning
rod to ionize the surrounding air. This ionization forms a low-resistance path to earth for the electrical current from lightning, preventing
it from damaging the structure it protects.

Lightning current travels through the conductor to a down conductor, which in turn is connected to a network of conductors buried in the
ground, known as a grounding system. This system dissipates lightning energy safely into the ground, preventing it from damaging the
buildings or starting fires.

It is essential to note that the Franklin rod does not prevent lightning strikes, but rather provides a controlled path for the current to flow
to earth. Additionally, multiple arresters can be installed on large buildings or large areas to improve lightning protection.

Over the years, Franklin rod have proven to be highly effective in protecting against lightning, greatly reducing structural damage and risks
to people. However proper design ans intallation are essential to ensure proper operation. Therefore, it is recommended that a qualified
proffesional perform the installation ad periodic maintenance of the system to ensure optimal protection against the dangers of electrical
storms.

> FRANKLIN ROD

Franklin rods for protection against lightning. It can be used as a sensor elementt or be part of passive
protection systems. Includes a brass adapter piece for Ø 45 mm and internal connection with round
conductor Ø 8/10 mm (50/70 mm2).

Reference Material Model Dimensions (mm)


AS700010 AISI 304 Multiple Franklin rod 1 x (Ø 16 x 170) + 3 x (Ø8 x 65)
AS700020 AISI 304 Simple Franklin rod Ø 16 x 170
AS700010
Complies with: UNE 21186, NFC 17102 and NP 4426

18 PASSIVE RODS www.aiditecsystems.com


PASSIVE RODS

PA S S I V E R O D S

FRANKLIN ROD - FARADAY CAGE

PROTECTION LEVEL: II determined according to the NF C 17-100.


DESCRIPTION: 50 cm franklin rods installed around the entire of the roof every 15 meters. 10 meters ceiling mesh grid. Each point is
connected to a downspout and its respective ground connection.

PROTECTION ZONE COVERED BY THE FARAAY CAGE

PROTECTION ZONE AT ROOF LEVEL


EARTH PROTECTION ZONE

SCHOOL BUILDING

www.aiditecsystems.com PASSIVE RODS 19


ACCESSORIES

ACCESSORIES

SPARK GAP
Lightning protection regulations indicate that each lightning rod must be have its own ground connection and independently must have a
velue below 10 ohms. On the other hand, they also recommend linking the lightning rod ground connections to other ground connections
to avoid potential differences.

Direct connections can be made, but it is always better to do it with spark gaps for different reasons:

• The facilitate that the main path of the lightning current is through the grounding of the lightning rod.
• It maintains the different ground connections at the same potential, avoiding dangerous spark jumps through unwanted areas, but
only at the moment of discharge, because in normal state it keeps them separated.
• They prevent some sensitive systems or equipment from being influenced by these direct connections.
• They protect against corrosion that can occur in some cases by directly connecting different ground connections.

Spark gaps are also used to protect antennas, metal structures, tanks, etc.

148 mm

40 mm

Ø
56
Ø 8 mm

mm

22 ACCESSORIES www.aiditecsystems.com
ACCESSORIES

> SPARK GAP FOR EARTHING AND OTHER STRUCTURES

Spark gap for equipotential protection for connection to lightning rods and grounding.

AS500550

Reference Material Round conductor Flat conductor


AS500550 Stainless steel Ø 8 to 10 mm Up to 30 mm
Complies with: UNE 21186, NFC 17102 and NP 4426

> SPARK GAP FOR ANTENNAS

It is connected to the antenna mast to ensure equipotential bonding between the metallic elements, thus avoiding dangerous sparks
between the lightning protection system and the antenna mast, which could even cause fire and damage to the structure.

+
AS600550 AS700150

Reference Material Antennas Round conductor Flat conductor


AS600910 Stainless steel Ø 30 to 50 mm Ø 8 to 10 mm Up to 30 mm
Complies with: UNE 21186, NFC 17102 and NP 4426

www.aiditecsystems.com ACCESSORIES 23
ACCESSORIES

ACCESSORIES

ADAPTATION PIECE
> ADAPTATION PIECE WITH INTERNAL CONNECTION

Adaptation piece for joining the lightning rod with the mast and internal connection with the down conductor.

AS700100

Reference Material Mast For conductor For plate


AS700100 Stainless steel Ø 45 mm Ø 8/10 mm 30 x 2 mm
Cimplies with: EN 50164, UNE 21186, NFC 17102 and NP 4426

> U-BOLT

U-Bolt for joining the lightning rod with the mastt and with a stainless steel flange for the external connection with the down conductor.

AS700150

Reference Material Mast For conductor For plate


AS700150 Stainless steel Up to Ø 45 mm Up to Ø 15 mm 50 x 5 mm
Complies with: UNE 21186, NFC 17102 and NP 4426

24 ACCESSORIES www.aiditecsystems.com
ACCESSORIES

ACCESSORIES

MASTS
> WALL-MOUNTED MAST

Mast made of galvanized steel or stainless steel (optimal for highly corrosive environments) with a diameter
of 45 and a thickness of 2 mm to be attached to buildings or structures with 2 supports (except 8 m masts
that are fixed with 3 supports + guys).

Reference Material Sections / Length Total length (m)


AS700229 Galvanized steel 1 section / 2 m 2
AS700229
AS700231 Galvanized steel 2 section / 2 m 4
AS700233 Galvanized steel 3 section / 2 m 6
AS700235 Galvanized steel 4 section / 2 m 8
AS700270 Stainless steel 1 section / 2 m 2
AS700271 Stainless steel 2 section / 2 m 4
AS700273 Stainless steel 3 section / 2 m 6
AS700275 Stainless steel 4 section / 2 m 8
Complies with: UNE 21186, NFC 17102 and NP 4426

> FREE STANDING MAST*

Masts to be installed on a concrete block embedded in the ground, made of galvanized steel and studied to
withstand winds of up to 140 Km/h. AS700310

Base plate Foundation


Reference Length Section Hinge Assembly
dimensions (mm) dimensions (cm)
AS700306 6m 2 Yes Screwed 400 x 400 x 10 80 x 80 x 80
AS700308 8m 3 Yes Screwed 400 x 400 x 10 80 x 80 x 80
AS700310 10 m 4 Yes Screwed 500 x 500 x 10 100 x 100 x 100
AS700312 12 m 5 Yes Screwed 500 x 500 x 10 100 x 100 x 100
AS700315 15 m 6 Yes Screwed 500 x 500 x 10 150 x 150 x 150
AS700320 20 m 8 - Welded 600 x 600 x 10 200 x 200 x 200
AS700325 25 m 10 - Welded 750 x 750 x 12 200 x 200 x 200
Complies with: UNE 21186, NFC 17102 and NP 4426
*Consult delivery time

www.aiditecsystems.com ACCESSORIES 25
ACCESSORIES

ACCESSORIES

ANCHORAGES

> SURFACE ANCHORAGE

Anchors for fixing masts up to Ø 45 mm to roofs and flat surfaces.

Reference Material Tube height Base plate dimensions


AS700400 Galvanized steel 75 cm 300 x 300 mm
AS700401 Galvanized steel 100 cm 500 x 500 mm
AS700400
AS700602 Zinc plated steel 45 cm 250 x 250 mm
AS700603 Zinc plated steel 75 cm 250 x 250 cm
Complies with: UNE 21186, NFC 17102 and NP 4426

26 ACCESSORIES www.aiditecsystems.com
ACCESSORIES

> ANCHORS TO RECESS OR SCREW

Standard anchor to embed or screw. Manufactured in a “U” profile of 20 x 40 x 20 and thickness of 3 mm.

Reference Material Length Type of fixing


AS700420 Galvanized steel 35 cm To embed
AS700421 Galvanized steel 50 cm To embed
AS700422 Galvanized steel 35 cm To screw
AS700423 Galvanized steel 50 cm To screw
AS700424 Galvanized steel 20 cm To screw AS700422

Complies with: UNE 21186, NFC 17102 and NP 4426

> LIGHT ANCHORAGE TO EMBED

Light anchor to embed. Manufactured in a “U” profile.

Reference Material Length


AS700440 Galvanized steel 35 cm
AS700441 Galvanized steel 50 cm AS700441

AS700640 Stainless steel 35 cm


AS700641 Stainless steel 50 cm
Complies with: UNE 21186, NFC 17102 and NP 4426

> ANCHORAGES TO WELD

Anchor for wleding to structures. Manufactures in a “U” profile of 20 x 40 x 20 mm and thickness of 3 mm.

Reference Material Length


AS700500 Galvanized steel 35 cm
AS700501 Galvanized steel 50 cm
AS700700 Zinc plated steel 35 cm
AS700501
AS700701 Zinc plated steel 50 cm
Complies with: UNE 21186, NFC 17102 and NP 4426

www.aiditecsystems.com ACCESSORIES 27
ACCESSORIES

> ADHUSTABLE ANCHORAGE*

Adjustable anchor made of a 20 x 40 x 20 mm “U” profile and 3 mm thick.


Fixation by screws.

Reference Material Regulation


AS700540 Galvanized steel From 50 to 80 cm
AS700540
Complies with: UNE 21186, NFC 17102 and NP 4426

> ANCHORAGE FOR TRESTLE TOWER

Anchors for fixing masts to turrets and lattices. Manufactured in a “U” profile of 20 x 40 x 20 and 3 mm thick.

Reference Material Length For turrets


AS700560 Galvanized steel 42 cm Model 180
AS700561 Galvanized steel 49 cm Model 250
AS700562 Galvanized steel 60 cm Model 360
AS700760 Zinc plated steel 42 cm Model 180
AS700761 Zinc plated steel 49 cm Model 250
AS700560

AS700762 Zinc plated steel 60 cm Model 360


Complies with: UNE 21186, NFC 17102 and NP 4426

*Consult delivery time

28 ACCESSORIES www.aiditecsystems.com
ACCESSORIES

ACCESSORIES

CONDUCTORS
> TAPE CONDUCTOR

Bara flat conductors are recommended by lightning protection regulations as downstream and ground
conductors.

Reference Material Dimensions


AS600121 Tinned copper 30 x 2 mm
AS600181
AS600181 Stainless steel 30 x 2 mm
Complies with: IEC 62305, EN 50164, EN 13601, BS 7430, UNE 21186, NFC 17102, NP 4426, AS 1567,
BS 6746, BS 2898, BS 6360 and AS 1866

> SOLID CONDUCTOR

Bare solid conductors are recommended by lightning protection regulations for use in highly corrosive
environments.

Reference Material Dimensions


AS600200 Copper Ø 8 mm
AS600260 Galvanized steel Ø 8 mm AS600200

AS600261 Galvanized steel Ø 10 mm


Complies with: IEC 62305, EN 50164, EN 13601, BS 7430, UNE 21186, NFC 17102, NP 4426, AS 1567,
BS 6746, BS 2898, BS 6360 and AS 1866

> STRANDED CONDUCTOR*

Bare stranded conductors are recommended by lightning protection regulations for use in highly corrosive
environments.

Reference Material Dimensions Wires


AS600301 Copper 50 mm2 19
AS600302 Copper 75 mm2 19
AS600303 Copper 95 mm2 19
Complies with: IEC 62305, EN 50164, EN 13601, BS 7430, UNE 21186, NFC 17102, NP 4426, AS 1567, AS600301

BS 6746, BS 2898, BS 6360 and AS 1866


*Consult delivery time

www.aiditecsystems.com ACCESSORIES 29
ACCESSORIES

ACCESSORIES

FIXINGS FOR CONDUCTORS


> FIXINGS FOR FLAT CONDUCTORS

Clamps for fixing flat conductors to buildings and strcutures. Includes plug and screw.

Reference Material For conductor Conductor elevation


AS600460 Stainless steel Up to 30 mm wide 10 mm
AS600460
AS600461 Stainless steel Up to 30 mm wide 60 mm with extension
AS600462 Stainless steel Up to 30 mm wide 110 mm with extension
AS600481 Nylon Up to 30 mm wide 25 mm
AS600482 Nylon Up to 30 mm wide 40 mm
AS600450 Stainless steel 30 x 2 mm Sin elevación
AS600482
Complies with: UNE 21186, NFC 17102 and NP 4426

> FIXINGS FOR ROUND CONDUCTORS

Staples for fixing round conductors to buildings and structures. Includes plug and screw.

Referencia Material For conductor Conductor elevation


AS600560 Nylon Ø 7 to 10 mm 10 mm
AS600561 Nylon Ø 7 to 10 mm 60 mm with extension AS600580

AS600562 Nylon Ø 7 to 10 mm 110 mm with extension


AS600580 Nylon Ø 8 mm 25 mm
AS600581 Nylon Ø 8 mm 40 mm AS600560

Cumple con: UNE 21186, NFC 17102 y NP 4426

> SEPARATORS

Spacers/extensions for fixing conductors to buildings and structures.

Referencia Material Diameter Length


AS600680 Stainless steel Ø 25 mm 50 mm
AS600681 Stainless steel Ø 25 mm 100 mm
AS600690 Brass Ø 25 mm 50 mm
AS600691 Nylon Ø 25 mm 100 mm
AS600691

Complies with: UNE 21186, NFC 17102 and NP 4426

30 ACCESSORIES www.aiditecsystems.com
ACCESSORIES

ACCESSORIES

SUPPORT FOR CONDUCTOR FIXATION


> FOR FLAT SURFACES

Supports for fixing conductors to flat surfaces.

Reference Material Support For conductor Status


AS600601
AS600600 Polypropylene Conical Ø 8 mm Empty
AS600601 Polypropylene Conical Ø 8 mm Filled
Complies with: UNE 21186, NFC 17102 and NP 4426

> FOR TILES

Supports for fixing conductors to tiles.

AS600640
Reference Material For conductor Type
AS600640 Stainless steel Ø 6 to 11 mm Adjustable 170/240 mm
AS600641 Stainless steel Ø 8 mm Extensible 170/280 mm
Adjustable 120/240 mm
AS600642 Stainless steel Ø 6 to 10 mm
(for ridge cap) AS600642

Adjustable 120/240 mm
AS600643 Cooper Ø 6 to 10 mm
(for ridge cap)
AS600643
Pressure.
AS600660 Stainless steel Ø 8 mm
For 8/10 mm thickness
AS600641
Pressure.
AS600661 Stainless steel Ø 8 mm
For 15/20 mm thickness
AS600670 Stainles steel Ø 6 to 10 mm For sandwich type roofs
AS600700 Stainless steel No include fixing For pipes from Ø 60 to 150 mm
AS600670
AS600720 Stainless steel No include fixing For pipes from Ø 60 to 150 mm
AS600740 Cooper No include fixing For pipes from Ø 60 to 150 mm
Complies with: EN 50164, UNE 21186, NFC 17102 and NP 4426 AS600700

www.aiditecsystems.com ACCESSORIES 31
ACCESSORIES

ACCESSORIES

JOINTS AND CONNECTIONS


> MULTICLAMP TERMINAL

Universal connector for round stainless steel conductors with multiple connection methods.

Reference Material Dimensions For conductor Screw AS600841

AS600841 Stainless steel 40 x 40 x 40 mm Ø 8 to 10 mm M-10 x 40 mm


Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426

> TEST LINK

Cross connector for flat and round conductors and test link. AS600823

Reference Material For conductor For flat For electrode


AS600823 Stainless steel Up to Ø 10 mm Up to 30 x 3 mm Up to Ø 17 mm
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426

> T CONNECTOR

T-connector for round conductors.

Reference Material For conductor


AS600806 Copper Ø 8 to 10 mm
AS600845 Galvanized steel Ø 8 to 10 mm AS600845

Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426

> LINEAR

Linear connector for round conductors.

Reference Material For conductor


AS600804 Copper Up to Ø 10 mm
AS600824 Stainless steel Up to Ø 10 mm
AS600824
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426

> PARALLEL

Parallel connector for round conductors.

Reference Material Section


AS600843 Brass - Stainless steel 16-95 mm2
AS600843
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426

32 ACCESSORIES www.aiditecsystems.com
ACCESSORIES

> TO GUTTER

Gutter connector for round conductors.

Reference Material For conductor


AS600821 Stainless steel Ø 6 to 10 mm AS600821

Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426

> BIMETALLIC

Bimetallic connector with an intermediate plate for flat and round conductors.

Reference Material For conductor For flat


AS600870 Cu / Fe Ø 8 to 10 mm -
AS600871 Cu / Fe Ø 8 to 10 mm Up to 30 mm
Cumple con: IEC 62305, EN 50164, UNE 21186, NFC 17102 y NP 4426 AS600870

> KS

KS type connector for round conductors.

Reference Material For conductor


AS600847
AS600847 Brass Ø 6 to 10 mm
AS600826 Brass Ø 6 to 10 mm
AS600808 Brass Ø 6 to 10 mm AS600826

Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426

www.aiditecsystems.com ACCESSORIES 33
ACCESSORIES

ACCESSORIES

OTHER ACCESSORIES
> GUARD TUBE

Tube for the mechanical protection of the down conductor of the protection system.

Reference Material Length For conductor For flat


AS600950 Galvanized steel 2m Up to Ø 15 mm Up to 30 mm
AS600951 Stainless steel 2m Up to Ø 15 mm Up to 30 mm
AS600952 cross-linked polyethylene 2m Up to Ø 15 mm Up to 30 mm
AS600950
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 y NP 4426

> WIND KIT

Fastening and tensioning of masts by means of steel winds to prevent falls due to the effect of the wind.

Reference Material Cable section Length


AS700352 Stainless steel Ø 3 mm 50 m
Complies with: UNE 21186, NFC 17102 and NP 4426 AS700352

> INSULATED CABLE*

Non-flammable insulated cable to ensure systems work in extreme conditions.

Reference Material Section Type of coating


AS600306 Copper 50 mm2 Flame retardant
Complies: UNE 21186, NFC 17102 and NP 4426 AS600306

*Consult delivery time

34 ACCESSORIES www.aiditecsystems.com
ACCESSORIES

> ZAPA TUBE

Flexible metal tube for cable protection.

Reference Material Section Type of coating


AS600752

AS600752 Steel Ø 16 mm PVC


Complies with: UNE 21186, NFC 17102 and NP 4426

> DISCONNECTOR BOX

Sectionalizing box for testing grounding resistance. AS600401

Reference Material Dimensions Section


AS600401 Polycarbonate + ABS 95 x 145 x 75 mm 35-70 mm2
Complies with: EN 60670, NP EN 60529 and EN 62262

> MULTILAYER PIPE*

Cross-linked polyethylene protection tube against metallic shocks.

Reference Material Diameter Section Length Weight


AS600951 Polietileno reticulado 3 mm Ø 8 - 10 mm 50 - 70 mm2 2000 mm 728 gr.
AS600960 Polietileno reticulado 3 mm Ø 8 - 10 mm 50 - 70 mm2 2500 mm 910 gr.
Complies with: UNE 21186, NFC 17102 and IEC 62305 AS600951

*Consult delivery time

NOTE

This catalog only includes the most common accessories for a complete installation. If you need a product with different
characteristics, contact os and and our technical department will advice you on the most appropriate choice.
Tel.: +34 963 842 957
Email: info@aiditecsystems.com

www.aiditecsystems.com ACCESSORIES 35
GROUNDING

GROUNDING

ELECTRODES
> ACTIVE ROD*

Active electrode with moisture exchanger and drainage of ionic compound especially indicated for carrying
out grounding in very high resistivity terrain. Includes stainless steel connector for conductors from Ø 8 to
10 mm and flat up to 30 mm.

Reference Material Diameter Length Form


AS500070 Copper + Composite 28 mm 1500 Vertical
AS500071 Cooper + Composite 28 mm 2000 Vertical
AS500080 Cooper + Composite 50 mm 1500 Vertical
AS500081 Cooper + Composite 50 mm 2000 Vertical AS500070

Complies with: IEC 62305, UL 467, EN 50164, UNE 21186, NFC 17102 and NP 4426

> GRAPHITE ELECTRODE*

Rigid graphite electrode indicated for making earth connections in particularly aggressive terrain. Includes
stainless steel connector for conductors from Ø 8 to 10 mm and flat up to 30 mm.

Reference Material Diameter Length Drilling


AS500040 Rigid graphite 50 mm 400 mm 2m
AS500041 Rigid graphite 50 mm 800 mm 2m
AS500040
Complies with: UNE 21186, NFC 17102 and NP 4426

> ELECTRODO DE ACERO COBRIZADO*

Electrodo de acero cobrizado para tomas de tierra con un alto grado de resistencia a la corrosión.

Referencia Material Diámetro Longitud Recubrimiento Acabado


AS500101 Acero cobrizado 14,2 mm 2m 254 micras Liso
AS500131 Acero cobrizado 14,2 mm 2m 100 micras Liso
AS500161 Acero cobrizado 14,2 mm 2m 254 micras Roscado AS500101

Cumple con: BS 7430, BS 6651, UL 467, NFPA 780, IEC 62305, EN 50164, UNE 21186, NFC 17102 y NP 4426

> ELECTRODO DE ACERO INOXIDABLE*

Electrodo de acero inoxidable para tomas de tierra con un alto grado de resistencia a la corrosión.

Referencia Material Diámetro Longitud Acabado


AS500133 Acero inoxidable 14,2 mm 2m Liso
AS500133
Cumple con: IEC 62305, UL 467, EN 50164, UNE 21186, NFC 17102 y NP 4426
*Consult delivery time

38 GROUNDING www.aiditecsystems.com
GROUNDING

GROUNDING

ACCESSORIES FOR ELECTRODES


> ELECTRODE UNION CONNECTOR

Accesory for extension and driving of the electrodes.

Reference Material For electrode


AS500140 Bronze / Copper SMOOTH of Ø 14,2 mm
AS500190 Bronze / Copper THREADED of Ø 14,2 mm
AS500140
Complies with: UNE 21186, NFC 17102 and NP 4426

> STAPLES

Staples for joining electrodes with grounding conductors.

Reference Material For electrode For round conductor For flat conductor AS500390

AS500330 Copper Up to Ø 20 mm Up to 70 mm2 Up to 30 mm


AS500390 Brass Up to Ø 14,2 mm Up to 70 mm2 -
AS500391 Bronze Up to 5/8’’ - -
AS500391
Complies with: UNE 21186, NFC 17102 and NP 4426

> THREADABLE ACCESSORIES

Accessories for extension and nailing of stainless steel electrodes.

Reference Accessories Material For electrode AS500280

AS500250 Screw Hardened steel Ø 16 mm


AS500250

AS500251 Spike Hardened steel Ø 16 mm


AS500252 Nailed point Stainless steel Ø 16 mm
AS500280 Nailed point Galvanized steel Ø 20 mm
AS500252
Complies with: UNE 21186, NFC 17102 and NP 4426

www.aiditecsystems.com GROUNDING 39
GROUNDING

GROUNDING

EARTHING IMPROVERS
> WELLCONDUCTOR

Totally ecological, non-corrosive, very hygroscopic and fast-acting ionic compound that substantially
improves the conductivity of the ground.

Reference Material Weight


AS500460 3 compounds 700 gr
Complies with: EN 50164, UNE 21186, NFC 17102 and NP 4426 AS500460

> GROUND PLATES

Plates with connector for conductors recommended as grounding electrodes to obtain a very low resistance
in very rocky terrain due to the large surface in contact with the ground.
AS500411
Reference Material Dimensions For conductor
AS500401 Copper 500 x 500 x 1,5 mm 6
AS500411 Copper 500 x 500 x 1,5 mm 8
Complies with: EN 50164, UNE 21186, NFC 17102 and NP 4426

INSPECTION PITS FOR GROUNDING


> EARTHING PIT

Polypropylene box to locate and organize the earth connections. Chemical and UV resistant.

Reference Material Dimensions Hole


AS500512 Polypropylene 200 x 200 x 200 mm Ø 200 mm
AS500513 Polypropylene 300 x 300 x 300 mm Ø 200 mm
Complies with: EN 50164, UNE 21186, NFC 17102 and NP 4426 AS500512

> CONNECTION BREIDGE FOR INSPECTION PIT

Stainless steel connection bridge for the equipotential bonding of earthing electrodes and round conductors
of Ø 8/10 mm and flat conductors up to 30 mm wide.

Reference Material Dimensions Connections For onspection pit


AS500540 Stainless steel 60 x 5 x 196 mm 6 AS500512
AS500541 Stainless steel 60 x 5 x 242 mm 8 AS500513
Complies with: EN 50164, UNE 21186, NFC 17102 and NP 4426 AS500540

40 GROUNDING www.aiditecsystems.com
GROUNDING

GROUNDING

EQUIPOTENTIAL BONDING
> BONDING BAR

Compensation and equipotentiality bars to be fixed using thermostable, self-extinguishing, halogen-free


and UV-resistant insulators. With a connection system using M-10 stainless steel crews, which allows the
joining of conductors of different types and ections using suitable connection terminals.

Reference Material Dimensions Connections


AS500570 Copper 250 x 40 x 5 mm 6
AS500570

AS500571 Copper 310 x 40 x 5 mm 8

AS500572 Copper 370 x 40 x 5 mm 10 AS500581

AS500573 Copper 430 x 40 x 5 mm 12


AS500580 Stainless steel 250 x 40 x 6 mm 6 AS500582

AS500581 Stainless steel 310 x 40 x 6 mm 8


AS500582 Stainless steel 370 x 40 x 6 mm 10
AS500573

AS500583 Stainless steel 430 x 40 x 6 mm 12


Complies with: DIN EN 62561-1

> FIXED GROUND TERMINAL*

Fixed connection points to connect to the framework of the structure or ground system.

Reference Material Contact plate Length Weight Thread


AS500135 Stainless teel Ø 80 mm 190 mm 217 gr. M-10 AS500135

Complied with: IEC 62305 and EN 50164

*Consult delivery time

NOTE

This catalog only includes the most common grounding accessories. If you need a product with different characteristics, contact
us and our technical department will advise you on the most appropiate choice.
Tel.: +34 963 842 957
Email: info@aiditecsystems.com

www.aiditecsystems.com GROUNDING 41
MEASUREMENT DEVICES

MEASUREMENT DEVICES

AS TESTER PRO
> LIGHTNING ROD TESTER WITH PRIMING DEVICE

The AS TESTER PRO is a high-tech portable measurement device that performs an automatic and complete test of the operation of
lightning rods with priming device. It is valid for all ESEs manufactured by Aiditec Systems, S.L.

Connection terminals

Controls
Battery
location
Power
button

> TECHNICAL CHARACTERISTICS

Reference AS600999
Dimensions 145 x 95 x 35 mm
Weight 276 gr.
Maximum output voltage 15 V
Lightning rod ignition test 0.3 mA ± 2%
Autonomy 1000 test
Battery 3,7 V / 1800 mAh
Operating temperature - 20ºC ... + 65ºC
Complies with: EN 62561-6, EN 50164-6 and UTE C 17-106

44 MEASUREMENT DEVICES www.aiditecsystems.com


MEASUREMENT DEVICES

Functioning
> INSTRUCTIONS

1. Plug the cables into the connection terminals of the tester.


2. Connect the clamps on the lightning rod in test position, as indicated in diagram regardless of
polarity.
3. Press the power button.
4. Select “New test”.
5. Press imultaneously the two TEST buttons to start the cycle.
6. Wait a few seconds while the tester performs the test.

> CONNECTION

The measurement must always be made between 2 existing potentials in all lightning rods with priming
devices (ESE):
• ATMOSPHERIC POTENTIAL (tip and body)
• EARTH POTENTIAL* (axis)

*If the measurement is made with the lightning rod installed, the connection to ground potential can be made
on the mast or the downpipe, since both elements would be attached to the axis of the lightning rod.

> SAFETY

• Do not touch the lightning rod at the time of testing.


• This equipment produces high voltage. Handle the alligator clips correctly.
• It is neccessary to press the test button with both hands.
• Avoid testing in stormy conditions.

> DISPLAYED MESSAGES

TEST OK Satisfactory test


TEST OK
TEST FAILED Faulty test

> OTHER MESSAGES ON DISPLAY

• OPEN CIRCUIT: Open circuit >> ESE is faulty.


• SHORT CIRCUIT: Short circuit >> ESE has short circuit or low resistive value.
• LEAKAGE CORRENT: Leak current >> ESE has current leakage.
• OUT OF RANGE: Out of range >> ESE works at voltages outside those specified.

WARNING

The AS TESTER PRO lightning rod tester only guarantees the proper functioning of the priming device but not the physical integrity
of the lightning rod, so a positive result in a lightning rodd that has suffered physical damage does not mean that it maintains
its condition. Level of coverage, since this does not depend only on the priming device, but also on physycal parameters, so to
guarantee the level of coverage, a visual inspection of the physical integrity of the lightning rod is also required.

www.aiditecsystems.com MEASUREMENT DEVICES 45


MEASUREMENT DEVICES

MEASUREMENT DEVICES

ADT COUNTER
> THE MOST VERSATILE, COMPLETE AND EASY TO INSTALL LIGHTNING METER

The ADT Counter counts and records the direct strikes and surges of a lightning protection system.

It is a device thet does not intervene in the operation of the protection system, but it is undoubtedly a very important element, because it
is the only way of knowing that the system has suffered a lightning strike and that a revision of the system must be carried out to verify
that everything is in correct condition and we continue to be protected.

Due to its design and its materials, it is robust, reliable and autonomous. It does not need external power supply and is compatible with
any lightning rod.

> BENEFITS

• Quick and easy installation.


• It is not necessary to disconnect or section the downspout.
• Valid to install in any type of driver.
• It can be used to count and record direct hits and surges.

> LOCATION

The device must be located at any point on the downspout between the protection tube and the mast. It is inserted in the downpipe with
less ohmic resistance or, failing that, in the straightest and most direct to ground.

> TECHNICAL CHARACTERISTICS

Reference AS600920
Dimensions 82 x 69 x 45 mm
Weight 285 gr.
Minimum threshold current (Itc 8/20 µs) 1 kA
Withstand and counted current (Imcw 10/350 µs) 100 kA
For conductor up to Ø 15 mm
For tapes up to 60 x 10 mm
Operating temperature - 20ºC ... + 65ºC
Complies with: EN 62561-6, EN 50164-6 and UTE C 17-106

46 MEASUREMENT DEVICES www.aiditecsystems.com


MEASUREMENT DEVICES

ADT Counter certificate

CERTIFICADO DE ENSAYO / TEST CERTIFICATE

Contador de Rayos ADT COUNTER


Lightning Event Counter ADT COUNTER

DESCRIPCIÓN DEL PRODUCTO / PRODUCT DESCRIPTION

El contador de impactos de rayos ADT Counter ha superado con éxito los ensayos eléctricos conforme a la norma UNE EN 62561-6, de acuerdo
con los tests consecutivos de mínima corriente umbral, corriente de no detección y corriente soportada y contada.

The lightning event counter ADT Counter has successfully passed the electrical test according to UNE EN 62561-6, according to the consecutive
tests of minimum current threshold, no current detection and withtand current and counted.

ORGANISMO QUE REALIZA LOS ENSAYOS / INSTITUTION PERFORMING THE TESTS

Instituto Tecnológico de la Energía ITE - Red de Institutos Tecnológicos de la Generalitat Valenciana.


Informe IE-ITE 140055-EN, de acuerdo con la norma UNE EN 62561-6: “Requisitos para los contadores de impactos de rayos”

Enery Technological Institute ITE - Network of Technological Institutes of the Valencian.


Report IE-ITE 140055-EN, according to standard EN 62561-6: “Requierements for lightning event counters”

CLASIFICACIÓN / CLASIFICATION

Para conexión con conductores de un SPCR / To connect with conductors of a LPS


Para conexión con conductores de SPD / To connect with SPD conductors

DATOS TÉCNICOS / TECHNICAL DATA

REF. AS600920

Dimensiones
82 x 69 x 45 mm
Dimensions
Peso
320 gr.
Weight
Código IP
IP-43
IP code
Temperatura de funcionamiento
- 20ºC ... + 65ºC
Operating temperature
Para conductor redondo Hasta / Up to
For round conductor Ø 15 mm
Para conductor plano Hasta / Up to
For flat conductor 60 x 10 mm
Mínima corriente umbral (Itc) con onda 8/20
1 kA
Minimum current threshold (Itc) with wave 8/20
No detección con Itc/2
0,5 kA
No detection (Itc/2) with wave 8/20
Corriente soportada contada (Imcw) con onda 10/350
100 kA
Withstand current and counted (Imcw) with wave 10/350
Cualquier punto de la bajante entre
Ubicación el tubo de protección y el mástil.
Location Any point on the downspout between
the protection tube and the mast.
Garantía limitada internacional 1 año
Limited international warranty 1 year

www.aiditecsystems.com MEASUREMENT DEVICES 47


SURGE PROTECTION DEVICES

SURGE PROTECTION DEVICES

WHY INSTALL THEM?

> FACILITIES WITH LIGHTNING RODS

It is necessary to install surge protection devices at least in the main electric switchboards of facilities equiped with lightning ross,
especially in those installations closest to the lightning rod.

In the case of high resistivity of the terrain, the need for installing overvoltage protection is even more crucial. The grater earth potential
differences, the higher energetic impact of overvoltages will be.

REASONS WHY TO INSTALL PROTECTION DEVICES

• Lack of insulation: a poor isolated insulation will be reached by atmospheric discharges when lightning strikes the lightning rod.
This devices redirect energy to the ground.

• Electromagnetic fields: as a result of lightning strikes, strong currents are generated. As a result magnetic fields are induced in
every conductor nearby, such as electric, data and coaxial cables.

> LARGE-SCALE FACILITIES

When lightning strikes the earth, currents may be induced in long-distance cables used for electric lines especially in large-scale facilities.
In order to avoid the loads of the installation to be damaged, surge protective devices must be installed at both ends of cables used for
the loads connection.

The higher the resistivity of the terrain, the grater the voltage gradients are and the need to protect both ends of the cable.

REASONS TO INSTALL PROTECTION DEVICES

• Inductions: when a lightning strikes the earth, an electrical potential funnel is generated and therefore electrical potential
differences appear in the terrain. Consequently, if an electric, coaxial or data cable runs between two different potential curves,
a current will be induced thereon and affect the loads fed by this cable.

50 SURGE PROTECTION DEVICES www.aiditecsystems.com


SURGE PROTECTION DEVICES

> ELECTRICAL FACILITIES WITH ELECTRONIC DEVICES

The transient overvoltages transmitted by the distribution networks have their origin the electrical distributors, line faults and mainly in
the atmospheric discharges that reach high-voltage lines.

Since the discharge lamps, variable speed drives, connection and disconnection of generators cause surges and short-term currents with
high-peak values, transient surges caused by network users and their surroundings can not be obviated.

In order to reduce incidences and avoid users, devices and facilities themeselves to be damaged, it is neccessary to install the properly
sorge protective devices for this kind of installations, at least in the main electrical switchboard and those with a high risk of suffering
the consequences of overvoltages.

REASONS WHY TO INSTALL SURGE PROTECTION DEVICES

• Induced atmospheric discharges on High-Voltage lines: an atmospheric discharge is the most damaging problem that you can
find in an installation. As a High-Voltage power line is the most likely place for a lightning to strike, most of the time it will reach
the installation through the electrical supply.

• Overvoltages originated in the electrical network: manoeuvres such as the switching of electric substation in electrical network
may cause micro-interruptions which are associated to transient voltage peaks that will be transmitted thrughout the whole
electrical network. As a result, the power supply of users facilities will be affected. Sometimes the value of voltage supplied by
electricity companies is higher that the maximum supported by electronic devices and consequently these are affected.

• The influence of power liads over electronics: the start or stop of engines and generators, the variable speed drives, etc.,
may produce overvoltages in the electronic devices. According to the magnitude of the overvoltage, electronic devices of the
installation may be damaged gradually or quickly.

ATMOPHERIC DISCHARGE
TO GROUND

Coaxial cable or Data that crosses two curves at


different potential and through which a current
is induced.

FUNNEL OF POTENTIAL

Power supply cable that crosses two curves at


different potential and through which a current is
induced.

www.aiditecsystems.com SURGE PROTECTION DEVICES 51


SURGE PROTECTION DEVICES

SURGE PROTECTION DEVICES

SPD - MODULAR PROTECTION SYSTEMS

> SURGE PROTECTION DEVICES TYPE 1

Surge protection devices Type 1 are recommended for installations where is a high probability of atmospheric
discharges.

C O M PA C T S U R G E P R O T E C T I O N D E V I C E S
Reference Description Uc. Máx Iimp Up
AD4-400/240 Tetrapolar 255 V 100 kA 1,5 kV
AD2-400/240 Bipolar 255 V 100 kA 1,5 kV
AD1-200/240 Unipolar F-N 255 V 50 kA 1,5 kV
AD1-400/240 Unipolar N-T 255 V 100 kA 1,5 kV
Available for all types of ground systems. TT, IT, TN-S and TN-C AD1-200/240
Standards: IEC 61643-1, EN 61643-11 and UL 1449

52 SURGE PROTECTION DEVICES www.aiditecsystems.com


SURGE PROTECTION DEVICES

> SURGE PROTECTION DEVICES TYPE 1 + 2

Surge protection devices Type 1+2 are installed at the head of installations to protect and it is combined the
characteristics of Type 1 and Type 2.

C O M PA C T S U R G E P R O T E C T I O N D E V I C E S
Uc. Máx Iimp (L-N)
Reference Description In Up
(F-N / N-T) (F-N / N-T)
BD4-100/240 Tetrapolar 275 V / 255 V 12,5 / 25 kA 50 kA 1,5 / 1,8 kV
BD4-100/240 S Tetrapolar 275 V / 255 V 12,5 / 25 kA 50 kA 1,5 / 1,8 kV
BD2-100/240 Bipolar 275 V / 255 V 12,5 / 25 kA 50 kA 1,5 / 1,8 kV
BD2-100/240 S Bipolar 275 V / 255 V 12,5 / 25 kA 50 kA 1,5 / 1,8 kV BD1-100/240

BD1-100/240 Unipolar 255 V 25 kA 50 kA 1,8 kV


BD4M-50/240 Tetrapolar 275 V / 255 V 12,5 / 50 kA 20 kA 1,5 kV
BD2M-50/240 Bipolar 275 V / 255 V 12,5 / 50 kA 20 kA 1,5 kV
For remote signaling please consult price and reference.
Available for all types of ground systems. TT, IT, TN-S and TN-C
Standards: IEC 61643-1, EN 61643-11 and UL 1449 BD4-100/240

PLUGGABLE SURGE PROTECTION DEVICES


Uc. Máx Iimp (L-N)
Reference Description In Up
(F-N / N-T) (F-N / N-T)
BD4-60/240 Tetrapolar 275 V / 255 V 7 / 15 kA 30 kA 1,5 / 1,8 kV
BD2-60/240 Bipolar 275 V / 255 V 7 / 15 kA 30 kA 1,5 / 1,8 kV
BV1-60/240 Unipolar 275 V 7 kA 60 kA 1,5 kV
For remote signaling please consult price and reference.
Available for all ttypes of ground systems. TT, IT, TN-S and TN-C
Standards: IEC 61643-1, EN 61643-11 and UL 1449 BD2-60/240

CARTRIDGE FOR PLUGGABLE SURGE PROTECTION DEVICES


Uc. Máx Iimp (L-N)
Reference Description In Up
(F-N / N-T) (F-N / N-T)
BD2-60/240 V Cartridge F-N 275 V 7 kA 30 kA 1,5 kV
BD2-60/240 D Cartridge N-T 255 V 15 kA 30 kA 1,8 kV
BD4-60/240 V Cartridge F-N 275 V 7 kA 30 kA 1,5 kV
BD4-60/240 D Cartridge N-T 255 V 15 kA 30 kA 1,8 kV BD4-60/240 D

www.aiditecsystems.com SURGE PROTECTION DEVICES 53


SURGE PROTECTION DEVICES

> SURGE PROTECTION DEVICES TYPE 2

Surge protection devices Type 2 are installed at the head of electrical installations and at secondary power
panels. Protect electronic and electrical equipment against transient overvoltages of origin industrial,
atmospheric and maneuvering.

PLUGGABLE SURGE PROTECTION DEVICES


Reference Description Uc. Máx In I Máx Up
BV1-40/240 Unipolar 275 V 20 kA 40 kA 1,2 kV
BD2-40/240 Bipolar 275 V / 255 V 20 kA 40 kA 1,2 / 1,5 kV
BD4-40/240 Tetrapolar 275 V / 255 V 20 kA 40 kA 1,2 / 1,5 kV
BV4M-40/240 Tetrapolar 275 V 20 kA 40 kA 1,2 kV
BV2M-40/240 Bipolar 275 V 20 kA 40 kA 1,2 kV
For remote signaling please consult price and reference.
Available for all types of ground systems. TT, IT, TN-S and TN-C BV1-40/240
Standards: IEC 61643-1, EN 61643-11 and UL 1449

CARTRIDGE FOR PLUGGABLE SURGE PROTECTION DEVICES


Reference Description Uc. Máx In I Máx Up
BD2-40/240 V Cartridge F-N 275 V 20 kA 40 kA 1,2 kV
BD2-40/240 D Cartridge N-T 255 V 20 kA 40 kA 1,5 kV
BV4M-40/240 V Cartridge F-N / N-T 275 V 20 kA 40 kA 1,2 kV
BV2M-40/240 V
BV2M-40/240 V Cartridge F-N / N-T 275 V 20 kA 40 kA 1,2 kV

54 SURGE PROTECTION DEVICES www.aiditecsystems.com


SURGE PROTECTION DEVICES

> SURGE PROTECTION DEVICES TYPE 2 + 3

Type 2+3 surge protection devices are installed in the power supply of the final receivers and combine the
characteristics of Type 1 and Type 3.

PLUGGABLE SURGE PROTECTION DEVICES


Reference Description Uc. Máx In I Máx Up Uoc
BV1-20/240 Unipolar 275 V 10 kA 20 kA 1,1 kV 20 kV
BD2-20/240 Bipolar 275 V / 255 V 10 kA 20 kA 1,1 / 1,3 kV 20 kV
BD4-20/240 Tetrapolar 275 V / 255 V 10 kA 20 kA 1,1 / 1,3 kV 20 kV
BV2M-20/240 Bipolar 275 V 10 kA 20 kA 1,1 kV 20 kV
BV4M-20/240 Tetrapolar 275 V 10 kA 20 kA 1,1 kV 20 kV
For remote signaling please consult price and reference.
Available for all types of ground systems. TT, IT, TN-S and TN-C BD4-20/240

Standards: IEC 61643-1, EN 61643-11 and UL 1449

CARTRIDGE FOR PLUGGABLE SURGE PROTECTION DEVICES


Reference Description Uc. Máx In I Máx Up Uoc
BD2-20/240 V Cartridge F-N 275 V 10 kA 20 kA 1,1 kV 20 kV
BD4-20/240 V Cartridge F-N 275 V 10 kA 20 kA 1,1 kV 20 kV
BV2M-20/240 V Cartridge F-N / N-T 275 V 10 kA 20 kA 1,1 kV 20 kV
BV4M-20/240 V Cartridge F-N / N-T 275 V 10 kA 20 kA 1,1 kV 20 kV
BD2-20/240 D Cartridge N-T 255 V 10 kA 20 kV 1,3 kV 20 kV
BD4-20/240 D Cartridge N-T 255 V 10 kA 20 kV 1,3 kV 20 kV BD4-20/240 D

www.aiditecsystems.com SURGE PROTECTION DEVICES 55


SURGE PROTECTION DEVICES

> SURGE PROTECTION DEVICES FOR PHOTOVOLTAIC INSTALLATIONS

Surge protection devices for the protection of equipment that work in direct current. They protect photovoltaic
equipment against transient overvoltages of atmospheric origin and maneuver.

PLUGGABLE SURGE PROTECTION DEVICES


Reference Description Ucpv PV In I Máx Up
BF3-40/600 Tripolar 620 Vcc 20 kA 40 kA 2,0 kV
BF3-40/1000 Tripolar 1060 Vcc 20 kA 40 kA 3,6 kV
BF3-40/1500 Tripolar 1520 Vcc 20 kA 40 kA 4,0 kV
For remote signaling please consult price and reference.
Standards: IEC 61643-1, EN 61643-11 and UL 1449 BF3-40/1000

CARTRIDGE FOR PLUGGABLE SURGE PROTECTION DEVICES


Reference Description Ucpv PV In I Máx Up
BF3-40/600 V Cartridge 620 V 20 kA 40 kA 2,0 kV
BF3-40/1000 V Cartridge 1060 V 20 kA 40 kA 3,6 kV
BF3-40/1500 V Cartridge 1520 V 20 kA 40 kA 4,0 kV
BF3-40/1000 V

SOLAR GARDEN PROTECTION SCHEME


NETWORK

1. BF3 series surge protector. Surge protectors for direct current installations. They protect the
inverters and other electrical equipment against transient overvoltages that come from strings.
2. BD4-40/240 surge protector.
3. BD4-100/240 surge protector. Protects the electrical installation from transient overvoltages that
may enter through the electrical connection.
DISTRIBUTION
PANEL

INVERTER
SOLAR
PANELS

56 SURGE PROTECTION DEVICES www.aiditecsystems.com


SURGE PROTECTION DEVICES

> SURGE PROTECTION DEVICES FOR DATA LINES

Surge protection devices for data lines protect the electronic equipment in the network of communication
against any overvoltage induced on the data lines. These surge protectors must be installed as close as
possible to the equipment to protect.

S U R G E P R OT E C T I O N D E V I C E S F O R D ATA L I N E S
Up
Reference Description Uc. Máx In I Máx IL
(L-L / L-T)
TD/5-B0 1 pair 6 Vcc 5 kA 10 kA 80/350 V 500 mA
TD/12-B0 1 pair 15 Vcc 5 kA 10 kA 150/350 V 500 mA
TD/24-B0 1 pair 28 Vcc 5 kA 10 kA 200/500 V 500 mA
TD/48-B0 1 pair 60 Vcc 5 kA 10 kA 250/500 V 500 mA
TD/110-A0 1 pair 180 Vcc 5 kA 10 kA 0,5 kV 500 mA
TD/250-A0 1 pair 275 Vcc 5 kA 10 kA 1/0,75 kV 500 mA
TD/5-B0
Standards: IEC 61643-1

SURGE PROTECTION DEVICES FOR TELEPHONE LINES, ADSL AND


ETHERNET
Uc. In I Máx Up
Reference Description IL
Máx (L-L / L-T) (L-L / L-T) (L-L / L-T) TD/110-RJ11-4

For telephone
TD/110-RJ11-4 lines with 180 Vcc 2 kA 5 kA 200/500 V 0,5 A
RJ1 connector
For Ethernet with
TD/5-RJ45-8-CAT 6 RJ45 connector, 6 Vcc 2,5 kA 5 kA 15/800 V 0,5 A TD/5-RJ45-8-CAT 6-POE

Cat 6
Ethernet
6 Vcc
TD/5-RJ45-8-CAT 6-POE RJ45, Cat 6 2,5 kA 5 kA 25/600 V 0,8 A
(57 Vcc POE)
Power Over Ethernet
Standards: IEC 61643-1

www.aiditecsystems.com SURGE PROTECTION DEVICES 57


SURGE PROTECTION DEVICES

> SURGE PROTECTION DEVICES FOR COAXIAL CABLES

Surge protection devices for coaxial cables protect electronic equipment associated with the coaxial
installation against any overvoltage induced on coaxial cables. These surge protectors must be installed as
close as possible to the equipment to protect.

SURGE PROTECTION DEVICES FOR COAXI AL CABLES


Reference Description Uc. Máx I Máx Impedancia Up
BNC type
CD-90-B-HH-75 70 Vcc 20 kA 75 Ω 700 V
Female - Female
BNC type
CD-250-B-HH-75 200 Vcc 20 kA 75 Ω 700 V
Female - Female
BNC type
CD-90-B-MH-75 70 Vcc 20 kA 75 Ω 700 V
Male - Female
BNC type
CD-250-B-MH-75 200 Vcc 20 kA 75 Ω 700 V
Male - Female
F type
CD-90-F-HH-75 70 Vcc 20 kA 75 Ω 700 V
Female - Female
F type
CD-250-F-HH-75 200 Vcc 20 kA 75 Ω 700 V
Female - Female
F type
CD-90-F-MH-75 70 Vcc 20 kA 75 Ω 700 V
Male - Female
F type
CD-250-F-MH-75 200 Vcc 20 kA 75 Ω 700 V
Male - Female
Available in other types of connection and impedance.
Standards: EN 61643-2

NOTE

In this catalog only the most common protectors are considered. If you need protectors with different characteristics, contact us
and our technical department will advise you on the most appropiate choice.
Tel.: +34 963 842 957
Email: info@aiditecsystems.com

58 SURGE PROTECTION DEVICES www.aiditecsystems.com


SURGE PROTECTION DEVICES

SURGE PROTECTION DEVICES

SPU - UNIFIED PROTECTION SYSTEM


Unified Protection Systems ake SPU -Sistemas de Protección Unificado- are made up of multiple redundant protection coordinated sets
with each other and designed according to the maximum discharge capacity criteria ans a minimum residual voltage. Its design allows
the implementation of accessory modules, as well as their adaptation to the needs of each installation, giving preference to safety and
the proper functioning of itself.

SPUs have been conceived to ensure the protection of the installations against overvoltagesm either atmospheric and industrial origin,
MF/AM harmonics and peaks associated with micro-interruptions. Optionally, the electrical installation will be protected against surges,
power interruptions and phase asymetry effects by adding a PTR4 set. This set is time and voltage programmable.

> TECHNICAL CHARACTERISTICS

• Great discharge capacity for 8/20 µs and 10/350 µs waveforms.


• Residual values close to the voltage of the protected installation.
• Frequency filtering.
• They are 3 or 4 effective and auto-coordinated protective sets each one by itself.
• Remove surges between phases, phases-earth, phases-neutral, neutral-earth.
• Responses time of 0,025 µs.
• Micro-interrumptions in the order of miliseconds are removed in low power installations.
• Repairable.

MAAIN FEATURES FOR DEFINING THE DIFFERENT RANGE OF SPU SERIES


4D SERIES 2D SERIES 4S SERIES 2S SERIES 3F SERIES
Installation mode Parallel Parallel Series Series Parallel
Nominal voltage (v) (1) 230/240 230 230/240 230 400
Protection against industrial
* * * * *
transient surges 8/20 μs
Protection against transient
* * * - -
lightning surge 10/350 μs (2)
Permanent surge protection (3) * * * - -
Undervoltage protection (3) * * * - -
Protection of phase asymmetry (3) * * * - -
MF/AF harmonic protection * * * * *
(1) Available in other voltages upon request.
(2) According to models.
(3) Requires addition of the PTR4 set.

www.aiditecsystems.com SURGE PROTECTION DEVICES 59


SURGE PROTECTION DEVICES

> SERIE SPU

SERIE 4D. Parallel connected three-phase surge protective devices.

SERIE 2D. SParallel connected single-phase surge protective devices.

SERIE 4S. Series connected three-phase protective devices.

SERIE 2S. Series connected singlee-phase surge protective devices.

SERIE DK. Parallel connected High Voltage surge protective devices.

SERIE TC. Protective devices for data lines and communication.

> ADVANTAGES AND BENEFIRTS OF INSTALLING SPU DEVICES

Our protection systems have been designed to protect every kind of electrical and electronic installations of any power, especially those
which have sensitive electronic devices. By installing a SPU system you are avoiding installations to be affected by: surges, permanent
overvoltages, micro-interrumptions, harmonics, undervoltages, phase asymmetry and electromagnetic compatibility.

> CUSTOM DEVICES

Since not all installations are alike and they need to be protected effectively, it is necessary to adapt to their features as well as our
customers demands. In MD we offer the possibility to modify the performances of our products to siut their needs. Therefore, any device
developed by MD can be:
• Set to special supply voltages: 500 V, 690 V, etc.
• Modify the IP rating in installations that require it.
• Increase the capacity of energy dissipation in installations bound to very energetic discharges.
• Increase the frequency filtering capacity.
• Adapt them to any network tipology: biphasic, three-phase lines without neutral, IT, TT, etc.
• Incorporate acoustic alarms.

60 SURGE PROTECTION DEVICES www.aiditecsystems.com


SURGE PROTECTION DEVICES

SURGE PROTECTION DEVICES

SELF-COMPSUMPTION
The SPF series equipment is specially designed for the protection of solar panel installations for self-
consumption that are connected to:

• The inside of a consumer network.


• A physical electrical connection to the transmission or distribution network.

This series of protectors for photovoltaic systems are intended to protect against overcurrents and
overvoltages caused by lightning strikes in the continuous part of direct current photovoltaic energy
generating installations of up to 1000Vdc.

SELF-CONSUMPTION PROTECTION SCHEME

TT WIRING 6mm2
CABLEADO TT 6mm2
CONNECTION
BORNA TERMINAL 35mm
CONEXIÓN 35mm
SEC. RECOMMENDED
SEC. RECOMENDADA
FROM 35 TO 16mm
DE 35 A 16mm22

PROTECTION BOX
STRING + ALTERNATE
CC WIRING 6mm2
AC WIRING 10 mm2

SPF 3/3-40/1000/15 (121)

ELECTRIC VEHICLE
SPVE panels are specially designed to protect vehicle charging stations as specified in ITC-
BT-52.

These panels protect the vehicle charging station against short circuits, ground faults and
overvoltages.

The protection against permanent overvoltages complies with the POP 50:550 regulation,
protecting the installation against voltages greater than 275 V.

The protection against transient overvoltages will protect the loads against voltage peaks of
atmospheric origin, as well as the transients associated with the maneuvers carried out on
the electrical network.

Options: They can also be supplied with lock, Schuko base, differentials with automatic
reconnection, polycarbonate casing and energy meter.

www.aiditecsystems.com SURGE PROTECTION DEVICES 61


GENERAL CONDITIONS

• Standard packaging is included.


• All products have a minimum guarantee of 2 years against any manufacturing defect.
• All our ADVANCE+, SIGMA+ and ELECTRON E15 have a limited lifetime warranty against all manufacturing defects.

LEGAL NOTICES

• Due to the policy of constant improvement of our products, Aiditec Systems, S.L. reserves the right to modify without prior notice
the products in this catalogue according to the evolution of the standards and techniques used at any time.
• The photos, drawings and technical descriptions in this catalogue are not contractual.
• Aiditec Systems, S.L. is not responsible for printing errors that may appear in this catalogue.
• Copying, electronic or other reproduction is only permitted under the authorization of Aiditec Systems, S.L.

October 2023. This catalog replaces the previous ones until further notice.
LIGHTNING PROTECTION SYSTEMS
AIDITEC SYSTEMS, S.L.
C/ Torres, 7 bajo dcha. 46018 Valencia, España (EUROPA)
info@aiditecsystems.com www.aiditecsystems.com
Tel. +34 963 842 957