You are on page 1of 4

AAnalyst 50 Double-Beam

Atomic Absorption Spectrometer

AA.
It’s not just an

It’s an AAnalyst.

The market leader in AA adds a new member to the AAnalyst family


The AAnalyst™ 50 offers a simple, robust and cost effective solution to your routine flame atomic
absorption needs. Whether you’re looking to expand into flame AA, add additional capability or
replace an older system, the AAnalyst 50 offers unbeatable value, low risk and is a worthwhile
addition to any routine analysis laboratory.

You don’t need an impressive budget to have impressive features.


The AAnalyst 50’s performance is normally associated with more expensive designs. Experience the
benefits of the:

• Double beam optical design: You do not need to take any time to warm up the hollow cathode
lamps, or to continuously recalibrate due to the optical drift inherent in a single beam design. Just walk
up, insert the lamp, select the element, set up the instrument and you are ready to go. You can start to
run your samples quickly and easily.

• Proven sample introduction and burner systems: This system has been used in thousands of
PerkinElmer atomic absorption systems. With a robust, universal stainless steel nebulizer, many difficult
sample types can be accommodated.

• Standard Deuterium lamp background correction: Don’t forget background correction, to help
you deal with those more challenging samples – the AAnalyst 50 comes as standard with a Deuterium
lamp background correction system. This is ideally suited for a laboratory with a wide range of sample
types or many different users.

• Complete safety interlocks system: The AAnalyst 50 includes all the essential safety interlocks
and a semi-automatic gas box that are often found in more expensive atomic absorption systems.
This makes the AAnalyst 50 simple and easy to use, with little risk of any operation errors. You don’t
need to worry about safety with the AAnalyst 50 flame AA!

You can rely on the AAnalyst 50 – It’s the smart choice for any
laboratory requiring routine flame atomic absorption analysis.

Speed, stability and confidence!


Order online at www.perkinelmer.com/aanalyst50
The versatility and flexibility you expect from
PerkinElmer’s AAnalyst line
Optical system with double beam technology interaction with the instrument. The status of all these safety
The AAnalyst 50 utilizes a double beam optical system which interlocks is clearly displayed on the front panel of the instrument.
provides excellent stability. Using a separate sample and For optimal performance and ease-of-use, the AAnalyst 50
reference beam, a double beam system automatically com- has the proven PerkinElmer sample introduction and burner
pensates for changes in hollow cathode lamp intensity. This systems. A robust and cost-effective stainless steel nebulizer,
gives improved stability and precision, quicker start-up and a with the option of a Pt/Ir nebulizer assembly for handling more
considerably reduced need for operator adjustments during corrosive samples, maximizes stability and sensitivity, even for
the analysis, (regular recalibration is often required with single the toughest samples. Maintenance is simple and no special
beam systems). The high-efficiency optical system provides tools are required. The nebulizer is adjustable so a wide variety
greater light throughput, enhanced signal to noise ratio and of aqueous or organic samples can be analyzed. An inert
polymer spray chamber provides superior performance for
overall better analytical performance for all elements.
analysis of corrosive and high solids matrices. The spray
For difficult or dirty samples, background correction is essential. chamber is manufactured from a high-strength composite,
The AAnalyst 50 includes a standard Deuterium background which eliminates the need for pressure-relief devices.
correction system.
The PerkinElmer burner is equally user friendly. The corrosion-
Optically, the AAnalyst 50 has everything you need in a flame resistant solid titanium burner heads install easily in the burner
AA – and it won’t break your budget! chamber, while a fail-safe mechanism ensures that the heads
are always properly restrained without the need for hold-down
Safe operation, optimal performance and cables. No tools are required to assemble or disassemble the
maximum versatility burner system for routine maintenance.
The AAnalyst 50 includes an array of safety features, typical for
The versatility and performance you will experience with the
more expensive atomic absorption systems, such as drain bottle,
AAnalyst 50 is normally associated with much more expensive
nebulizer, flame, burner head type and gas pressure sensors.
systems. With the AAnalyst 50 you will realize:
These ensure your safety during operation and simplify user

Figure 1. Clear, easy-to-under- Figure 2. Time-proven, easy-to- Figure 3. The 10-cm solid titanium
stand error indicators and safety use sample introduction system burner head warms up quickly and
interlocks for flame operation. for the maximum up-time in a maintains a stable flame. A 5-cm
busy laboratory. nitrous oxide-acetylene burner is
also available for analysis of re-
fractory elements.

2
Peace of Mind
for Busy, Routine Labs

• Robust and sensitive performance for all elements using our • Built in parallel printer port
proven sample introduction system that is standard in all Transfer data to the optional printer for producing permanent
AAnalyst models. records and documentation using the parallel port. Printed
• Superb stability and reproducible results, day-in and day-out, information includes:
with minimal instrument drift. – Calibration including standard concentrations

• Continuous uptime with our simple and maintenance-free – Calibration statistics with slope and regression coefficient
design – Replicate readings with statistics
• High flexibility with the 6-lamp turret utilizing PerkinElmer – Sample results
Atomax™ hollow cathode lamps. – Date and time

The AAnalyst 50 is the optimum atomic absorption spectrometer, • Graphical LCD interface
specifically designed for routine metals analysis. The display is easy to learn and master using the clear 3-line
alphanumeric display. The large LCD display and membrane
Easy to operate and maintain keypad are chemically resistant and simple to read.
Your work environment may be complex but your AA need
• Expect more from the leader in atomic absorption
not be complicated. With the simplicity of the AAnalyst 50
you’ll be ready to analyze samples at any time. With over 40 years of experience and a product line that
includes flame AA systems, high performance graphite furnace
• Experience the versatile power of the flexible, menu- AA systems, flexible ICP-OES systems, and the most powerful
driven software ICP-MS systems, PerkinElmer is the undisputed leader in
The AAnalyst 50 user interface and software is optimized to inorganic analysis. We have placed over 40,000 systems
provide answers quickly and conveniently. Use the display throughout the world, performing inorganic analyses every hour
to control the operation of the instrument with the menu- of every day. With the largest technical service and support
driven software. Save your specific staff in the industry and a solid reputation for quality prod-
lamp operating parameters or choose ucts and service, the AAnalyst 50 flame atomic absorption
from our range of pre-loaded spectrometer delivers superior value at a great price.
measurement modes for simple
and efficient analysis.
– The parameters for each element
are stored and can be recalled for
future use saving you time and
reducing the risk of making
mistakes
– Calibration curve and statistics
are displayed allowing a quick
visual check before pro-
ceeding with the analysis

Figure 4. Lamp selection in the flexible Figure 5. Menu-driven built-in software


6-lamp turret. controlled from membrane keypad.

w w w. p e r k i n e l m e r. c o m 3
SPECIFICATIONS
Spectral Range 190 to 900 nm
Bandwidth 0.25, 0.75, and 2.0 nm
Photometric System High efficiency Double Beam Optics
Range 0 to 2.0 Abs
Integration Time 0.5 to 99 sec
Monochromator Czerny-Turner design, 330 mm focal length with 1800 lines/mm holographic grating with hard coated optical components
Sample Introduction Spray Chamber Inert polymer mixing chamber made of high strength composite material.
System Nebulizer High Precision stainless Steel nebulizer, with option to use the Pt-Ir capillary
Flow Rate User-adjustable from 3 to 8 mL/min
Burner Standard 10 cm all-titanium burner head
Light Source Hollow Cathode Lamp (HCL)
Background Correction High energy Deuterium Lamp, supplied as a standard item
Safety Features Fully interlocked operation prevents ignition if the proper burner head, the nebulizer, end cap or burner drain system
is not correctly installed, the level of the liquid is incorrect or gas pressures are too low. Interlocks will automatically
shut down the gases if flame not detected. The flame is automatically and safely extinguished in the event of a
power failure or when the emergency flame shut off button is used.
Flow Control Integral Gas control system with panel flow meters
Detector Data System Wide range Photomultiplier tube R928
Control Microprocessor; sealed membrane keypad
Display 240 x 64 dots Graphics type LCD module
Hardcopy Parallel port
Power Supply HC Lamp 0 to 30 mA, modulated dual supply (for two lamps)
D2 Lamp 15 to 300 mA, modulated
PMT -200 to -1000 V
Power Input Switchable 100 & 230V ±10%, 50/60 Hz, Max. 220 VA
Dimension 822 + 90 x 550 x 395 mm
Weight 70 Kg
Warranty 1 year
Accessories Optional Hollow Cathode Lamps, 5 cm N2O-C2H2 burner head, Nebulizer with Pt-Ir capillary, air compressor,
blower and vent assembly, and printer.

ORDERING INFORMATION
Part No. Description
N2010520 AAnalyst 50 English version
Part No. Description
03030299 Pt-Ir Alloy Nebulizer Assembly
N2010390 AAnalyst 50 Chinese version
03030447 Blower and Vent Assembly, 110V
N0400102 Single-slot Air-acetylene Burner Head
03030448 Blower and Vent Assembly, 230V
N0400100 Single-slot Nitrous oxide Burner Head
20110040 Lexmark E260d Laser Printer, 110V
N0400103 Three-slot Burner Head, 10 cm
20110030 Lexmark E260d Laser Printer, 230V
03030352 Stainless Steel nebulizer Assembly

Speed, stability and confidence!


Order online at www.perkinelmer.com/aanalyst50

PerkinElmer, Inc.
940 Winter Street
Waltham, MA 02451 USA
Phone: (800) 762-4000 or
(+1) 203-925-4602
www.perkinelmer.com

For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs

©2009 PerkinElmer, Inc. All rights reserved. The PerkinElmer logo and design are registered trademarks of PerkinElmer, Inc. AAnalyst and Atomax are trademarks of PerkinElmer, Inc.
All other trademarks not owned by PerkinElmer, Inc. or its subsidiaries that are depicted herein are the property of their respective owners. PerkinElmer reserves the right to change
this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors.

008234_01

You might also like