You are on page 1of 1

CLEAN WATER LINE LEGEND D

F FAUCET 75
34
HB HOSE BIBB C
KS KITCHEN SINK
A B C D A B C D 50 TE
R TA
NK R
PPEEDION
1 2"
F CT LR
31 P
GATE VALVE B WA
O
ON
MM& B
U NE DF
O GR
CO TO
WT WATER TANK 3125 3150 3475
3125 3150 3475
GV C T
3100 25 &B
WASTE PIPE
2000
A 31 GV T DN
05
CLEAN WATER LINE 5 GV
5 03 DR
OO
M

GV OM BE
HB O
DS DOWN SPOUT WATER TANK

2000
DN SERVICE AREA T&B DR

2000
BE
RD ROOF DRAIN KS ABOVE SLAB 00 CL
OS
ET
50
5
-IN 15
4
20 AL
K

4350
04
4
W

MASTER
GV GV 1 OM Y
BEDROOM 03 " PPR RO ON

1400
2

4
1 COMMON
BEDROOM " PPR D LC
2
UPFEED T&B
UPFEED BE W BA
CONNECTION LO
CONNECTION TO GRDFLR
00
57 BE
TO GRDFLR EN
DN OP LL
HA
LY
MI
FA

2500
GV GV

5700
KS 00
13

5700
UP 3 2'

2700
00
36

BEDROOM 04 BEDROOM 05

800
BEDROOM 01
3

3600
3 D 1

1300
1300
OPEN BELOW
OPEN GARDEN WALK-IN CLOSET

2'
HB
2' 34
75
C 3 10
0
A RE
A 00
14
V ICE R
R KS GV PP EEDION
SE 1 2" 00
50 F R
DN UPNECTDFL
25
31
B

3600
DINING AREA LIVING AREA
O GR


3600

00 HB O
FAMILY HALL BALCONY 20 GV C TO

3
4
GV
5 00
12 36

5000
CAR PORT A 3

2 PLANT BOX
CV
2 O OM
01
ER M
800

STROO DR
HB A UP BE 00

1550
M M ED 50

1550
PORCH B
GV
1 1 KS T CV
3200

GARDEN 00 50 R 50
PO
5
43 15
GV
20
UP CA
R M GV
EA
AR
4 00
00
27 R DE
N
LIV
ING
57 GA
EN
0 OPHB EA
80 AR CH
NG R
NI PO
00 DI UP
13 B OX

3 2'
PL

HB
A NT

R DE
N
00
36 GA

CLEAN WATER LAYOUT CLEAN WATER LAYOUT


0
80

2 GROUND FLOOR PLAN 2 SECOND FLOOR PLAN 2 00


32

P6 SCALE 1: 100 MTS P7 SCALE 1: 100 MTS 1

ISOMETRIC LAYOUT
2 CLEAN WATER
P8 SCALE 1: 100 MTS

DET'L OF VENT BELOW FLR.

FLOOR DRAIN
FINISH FLOOR (STAINLESS W/ SCREEN
REMOVABLE CLEANOUT & STRAINER)
COVER FRAME D

FIN. FLR. LINE FINISH FLOOR


C

VENT BELOW FLOOR


MIN.
300

B
FERRULE
PLUG
BRASS SCREW A

TO MAIN LINE
SIZE AS INDICATED
IN THE PLAN

SEWER LINE P-TRAP


50 0.089 0.046 0.225
DET'L OF VENT BELOW FLR. FLOOR DRAIN MOUNTING DETAIL 0.089 0.046 0.225
FLOOR CLEANOUT DETAIL 75
100 0.089 0.052 0.225

2 TYP. PIPE SPECIFICATIONS


P 9 SCALE 1: 50 MTS

DESIGN PROFESSIONAL PROJECT TITLE OWNER : SHEET CONTENTS : APPROVED SHEET NO.

CLEAN WATER LAYOUT


..\MSEC LOGOS\MSEC.1CROP.jpg CLEAN WATER ISOMETRIC LAYOUT P-2
MASTER PLUMBER PROPOSED SINGLE STOREY RESIDENTIAL BUILDING MR. & MRS. ABENILDE TYPICAL PIPE SPECIFICATIONS
PRC NO. PTR NO.
TIN NO. DATE ISSUED: CAD BY: AR. T.L.R.
KAWA-KAWA HILL, TUBURAN LIGAO CITY
Email : msempirecosntruction@gmail.com PLACE ISSUED: LOCATION : LOT 5, CENTRAL CITY SUBDIVISION, LEGAZPI CITY, ALBAY OWNER REPRESENTATIVE CAD DATE: FEB. 2023

You might also like