You are on page 1of 3

Report No.

JP/ETTL/ 14-15/TE- 1
Booking Advice No. :
Issued To Date of Receiving :
Date of Report :
Name of Work
Letter Reference
Sample Particulars : A sample of Construction-Water (Bore Hole Water) was received.
Results
S.No. NAME OF THE TEST OBSERVATION REQUIREMENT CONFORMITY
838 as per IS 10500 & 456

1. CHEMICAL TEST
1 Acidity ,as per IS 3025 Pt - 22 ,Value in ml 1.9 5.0 Max Yes
2 Sulphates as SO4 ,as per IS 3025 Pt - 24 ,Value in mg/Liter 66 400 Max Yes
3 pH Value ,as per IS 3025 Pt - 11 7.31 6.5-8.5 Yes
4 Total Hardness as CaCO3 as per IS 3025 Pt - 21 ,Value in mg/Liter 462 600 Max Yes
5 Iron as Fe ,as per IS 3025 Pt - 53 ,Value in mg/Liter 0.02 0.3 Max Yes
6 Chlorides as Cl ,as per IS 3025 Pt - 32 ,Value in mg/Liter 612 1000 Max Yes
7 Magnesium as Mg, as per IS 3025 Pt - 46 ,Value in mg/Liter 3.4 100 Max Yes
8 Fluoride as F , as per IS 3025 Pt - 60 ,Value in mg/Liter 0.6 1.5 Max Yes
9 Alkalinity ,as per IS 3025 Pt - 23 ,Value in ml 184 300 Max Yes

Remarks: The Sample Conforms to IS 456 with respect to above test.


**********End of Result *********

Authorised Signatory

Report No. JP/ETTL/ 14-15/TE- 2


Booking Advice No. :
Issued To Date of Receiving :
Date of Report :
Name of Work
Letter Reference
Sample Particulars : A sample of Construction-Water (Salt Water) was received.
Results
S.No. NAME OF THE TEST OBSERVATION REQUIREMENT CONFORMITY
838 as per IS 10500 & 456

1. CHEMICAL TEST
1 Acidity ,as per IS 3025 Pt - 22 ,Value in ml 1.4 5.0 Max Yes
2 Sulphates as SO4 ,as per IS 3025 Pt - 24 ,Value in mg/Liter 72 400 Max Yes
3 pH Value ,as per IS 3025 Pt - 11 7.40 6.5-8.5 Yes
4 Total Hardness as CaCO3 as per IS 3025 Pt - 21 ,Value in mg/Liter 116 600 Max Yes
5 Iron as Fe ,as per IS 3025 Pt - 53 ,Value in mg/Liter 0.02 0.3 Max Yes
6 Chlorides as Cl ,as per IS 3025 Pt - 32 ,Value in mg/Liter 612 1000 Max Yes
7 Magnesium as Mg, as per IS 3025 Pt - 46 ,Value in mg/Liter 0.9 100 Max Yes
8 Fluoride as F , as per IS 3025 Pt - 60 ,Value in mg/Liter 0.7 1.5 Max Yes
9 Alkalinity ,as per IS 3025 Pt - 23 ,Value in ml 196 300 Max Yes

Remarks: The Sample Conforms to IS 456 with respect to above test.


**********End of Result *********

Authorised Signatory

Report No. JP/ETTL/ 14-15/TE- 3


Booking Advice No. :
Issued To Date of Receiving :
Date of Report :
Name of Work
Letter Reference
Sample Particulars : A sample of Construction-Water (Hudda Supply Water) was received.
Results
S.No. NAME OF THE TEST OBSERVATION REQUIREMENT CONFORMITY
838 as per IS 10500 & 456

1. CHEMICAL TEST
1 Acidity ,as per IS 3025 Pt - 22 ,Value in ml 0.6 5.0 Max Yes
2 Sulphates as SO4 ,as per IS 3025 Pt - 24 ,Value in mg/Liter 45 400 Max Yes
3 pH Value ,as per IS 3025 Pt - 11 7.41 6.5-8.5 Yes
4 Total Hardness as CaCO3 as per IS 3025 Pt - 21 ,Value in mg/Liter 128 600 Max Yes
5 Iron as Fe ,as per IS 3025 Pt - 53 ,Value in mg/Liter 0.01 0.3 Max Yes
6 Chlorides as Cl ,as per IS 3025 Pt - 32 ,Value in mg/Liter 156 1000 Max Yes
7 Magnesium as Mg, as per IS 3025 Pt - 46 ,Value in mg/Liter 1.0 100 Max Yes
8 Fluoride as F , as per IS 3025 Pt - 60 ,Value in mg/Liter BDL 1.5 Max -
9 Alkalinity ,as per IS 3025 Pt - 23 ,Value in ml 94 300 Max Yes

Remarks: The Sample Conforms to IS 456 with respect to above test.


**********End of Result *********

Authorised Signatory