Professional Documents
Culture Documents
Screenshot 2024-01-24 at 10.31.48 PM
Screenshot 2024-01-24 at 10.31.48 PM
catalogue
SEPTEMBER 2023
version
CATALOGUE
2023
SEPTEMBER
about
US
Fluid-App,
The value of experience!
3
technical
INFORMATION
Please read these instructions carefully before installation. All The use of filters is necessary to protect the system from MARKING CODE
operations must be carried out by specialised and competent bad-working, in order to avoid serious consequences for the
personnel. hydraulic installation and people. LETTER
ASSOCIATED MANUFACT.
The user must periodically check the condition and correct Fluid-app recommends a filtration of 15 microns for its valves. YEAR
WITH THE WEEK
functioning of the valves, the corrosion and the condition of the YEAR
2023 Y
OIL POWER SUPPLY
Use only mineral oil (HL, HLP) according to DIN 51524. The use of The solenoid valve coils must be supplied with voltages betwe- 2024 Z
other fluids may cause bad working of the valve. en +/- 10% of the nominal voltage at a maximum environment
temperature of 60°C. 2025 A Number of the
week.
VISCOSITY ’ The first week of
2026 B
The viscosity of the oil should be in the range of 15 mm2/s to SEALING the year starts
with the first
250mm2/s. O-rings mounted on the valves are in NBR 2027 C Monday
Recommended viscosity ISO VG 46 (for cartridge valves ISO VG The anti-extrusion rings used to protect the o-rings are made
32). of PTFE or NBR. 2028 D
2029 E
CONTAMINATION AND FILTRATION TESTING CONDITIONS
Excessive fluid contamination is the main cause of bad-wor- All the tests shown in the catalogue were carried out with mi- 2030 F
king in hydraulic installations. neral oil ISO VG 46 at a temperature of 40°C and an absolute
2031
Max. contamination with filter ISO 4406:1999 - class 19/17/14 filtration degree of 15 microns. G
5
products
Single counterbalance valves
GUIDE
MAX FLOW MAX PRESSURE CATALOGUE
TYPE 3D PORTS
l/min [USgpm] bar [PSI] PAGE MAX FLOW MAX PRESSURE CATALOGUE
TYPE 3D PORTS
l/min [USgpm] bar [PSI] PAGE
160
BSA [42,1]
24
BFA 40
BSPP
(GAS)
BSAY 26
BFC 42
60 350
[15,9] [5075]
350 BSPP
BSC [5075] (GAS)
28
BCA 44
60
[15,9]
CETOP3
BSI 30
BCC 46
BSL 32
160
BDA [42,1]
34
350 BSPP
BDAY [5075] (GAS)
36
60
[15,9]
BDC 38
6 7
products
Check valves
GUIDE
MAX FLOW MAX PRESSURE CATALOGUE
TYPE 3D PORTS CAVITY
l/min [USgpm] bar [PSI] PAGE MAX FLOW MAX PRESSURE CATALOGUE
TYPE 3D PORTS
l/min [USgpm] bar [PSI] PAGE
350 400
UFC [92,5] [5800]
/ 48 50 400
SBD [13,2] [5800]
78
50 500
UMC [13,2] [7250]
/ 50 BSPP
VCU (GAS)
80
70 350
FC111 [18,6] [5075]
BSPP FC112
VUC (GAS) FC113
52
FC114
VCB 82
120
[31,66]
FC115
350 FC116
VUD [5075] FC117
54
Flow control valves pressure compensated
FC118
150
SUA 72 150 210 BSPP
[39,6] RCP [39,6] [3050 ] (GAS)
/ 86
50 400 BSPP
SUD 74
[13,2] [5800] (GAS) F1B 58
15 250
FC105
[3,96] [3625]
150
SBA 76
[39,6] F1T 60
8 9
products
TYPE 3D
MAX FLOW
l/min [USgpm]
MAX PRESSURE
bar [PSI]
PORTS CAVITY
CATALOGUE
PAGE
GUIDE
Relief valves
15
F1C [3,96]
/ 62
TYPE 3D
MAX FLOW MAX PRESSURE
PORTS
CATALOGUE
l/min [USgpm] bar [PSI] PAGE
250 BSPP
[3625] (GAS)
30
18 M20B [8]
110
F2B [4,75]
FC106 64
50
M40B 112
Hose burst and shuttle valves [13,2 ]
80 320 BSPP
VBAT [21,1] [4641 ] (GAS)
/ 68
50
VAA [13,2]
108
45 350
VSS [12] [5075]
/ 104
Cetop valves
Flow dividers MAX FLOW MAX PRESSURE CATALOGUE
TYPE 3D PORTS
l/min [USgpm] bar [PSI] PAGE
MAX FLOW MAX PRESSURE CATALOGUE
TYPE 3D PORTS
l/min [USgpm] bar [PSI] PAGE
50
MC3 [13,2 ]
118
40 210 BSPP
VDF [10,6] [3050] (GAS)
116
210 BSPP
[3045] (GAS)
80
MC5 [21,1]
120
10 11
products
Pilot check valves
GUIDE
MAX FLOW MAX PRESSURE CATALOGUE
TYPE 3D PORTS
l/min [USgpm] bar [PSI] PAGE
VBD 88
50
[13,2]
VBS 90
VBDT 92
35
[9,2]
VBST 94
350 BSPP
[5075] (GAS)
VPD 96
VPF 98
60
[15,83 ]
VSP 100
DX
VSP 102
SX
12 13
products
Cartridge valves
GUIDE
MAX FLOW MAX PRESSURE CATALOGUE
TYPE 3D CAVITY
l/min [USgpm] bar [PSI] PAGE MAX FLOW MAX PRESSURE CATALOGUE
TYPE 3D CAVITY
l/min [USgpm] bar [PSI] PAGE
M20 124
30 350
VM2 [7,92] [5075]
144
30
SAE8/2
[8]
M21 126
2 cm3 200
PM2 [0,12 in3] [2900]
146
50
M40 [13,5]
FC002 130
18 350
DR2 [4,75] [5075]
150
350
[5075]
80
M80 [21,1]
FC005 134
50 350
VBC [13,5] [5075]
FC004 154
35
UC2 [9,2]
136
40
VDF3 [10,6]
SAE10/4 156
80
UC3 [21,13]
138
SAE8/2
CU2 140
40
[10,6]
CB2 142
14 15
products
Solenoid valves
GUIDE
MAX FLOW MAX PRESSURE CATALOGUE
TYPE 3D CAVITY
l/min [USgpm] bar [PSI] PAGE MAX FLOW MAX PRESSURE CATALOGUE
TYPE 3D CAVITY
l/min [USgpm] bar [PSI] PAGE
22 210
E2F28E [5,8] [3045]
160
E2S24C
E2S20C
E2S24E 168
40 350
E2S20E [10,6] [5075]
162
E2S24A
E2S20A
E2S26C
E2L20C 40 350
E2S26E [10,6] [5076]
SAE8/2 170
SAE8/2
30 300
E2L20E [7,92] [4350]
164
E2S26A
E2L20A
E2S28C
E2S22C
E2S28E 172
40 350
E2S22E [10,6] [5076]
166
E2S28A
E2S22A
16 17
products
TYPE 3D
MAX FLOW
l/min [USgpm]
MAX PRESSURE
bar [PSI]
CAVITY
CATALOGUE
PAGE
GUIDE
MAX FLOW MAX PRESSURE CATALOGUE
TYPE 3D CAVITY
l/min [USgpm] bar [PSI] PAGE
E6S30A
174 E3S24C
E6S30E
12 210
[3,2] [3045]
SAE8/3 E3S24E 182
E6S31A
176 E3S24A
E6S31E
E3S26C
E3S20C
70 350
E3S26E [18,7] [5076]
SAE10/2 184
E3S20E 178
E3S26A
E3S20A
70 350
[18,7] [5076]
SAE10/2 E3S28C
E3S22C
E3S28E 186
E3S22E 180
E3S28A
E3S22A
18 19
products
TYPE 3D
MAX FLOW
l/min [USgpm]
MAX PRESSURE
bar [PSI]
CAVITY
CATALOGUE
PAGE
GUIDE
C22 / / / 188
CNS / / / 190
MANIFOLDS / / / 192
20 21
in-line
VALVES
23
BSA COUNTERBALANCE BSPP
SINGLE COUNTERBALANCE VALVES FOR OPEN CENTER
BSA counterbalance valves (Gas thread) are used to keep a load locked, the built-in relief valve protects the system
from overpressure in the cylinder by draining the oil.
300 20 1 300 20
240 16 240 16
3/8 1/2
180 12 180 12 3/8 1/2
120 8
1/4 120 8
1/4 3/4
60 4 60 4
1
0 0 0 0
0 40 80 120 160 l/min 0 40 80 120 160 l/min
0 10 20 30 40 USgpm 0 10 20 30 40 USgpm
V2 V1
TAMPER PROOF CAP M10
CODE
M
0
T
P
B
62200021
C1 C2
0 0
S ORDERING CODE
210 30/210 70
1/4 BSPP FA1007 BSA4B21
3/4 110 [3045] [435/3045] [966] 2,7
50 [1,97] 95 [3,74] 81 [3,19] 23 [0,91] 66 [2,60] 43 [1,70] 7 [0,28]
BSPP [4,33] 350 60/350 145 [6]
3/8 BSPP 30 [1,18] 6,5 [0,26] 51 [2,01] FA1008 BSA4B35
[5075] [870/5075] [2100]
1:6,2
1/2 BSPP 60 [2,36] 100 [3,94] 84 [3,31] 21 [0,83] 67,5 [2,66] 50 [1,97] 210 30/210 70
FA1009 BSA5B21
160 [3045] [435/3045] [966] 4,7
3/4 BSPP 70 [2,75] 40 [1,57] 140 [5,51] 120 [4,72] 95,5 [3,75] 60 [2,36] 10 [0,39] 1 BSPP
[6,29] 350 60/350 145 [10,3]
10,5 [0,41] 26 [1,02] 71 [2,79] FA1010 BSA5B35
1 BSPP 80 [3,15] 50 [1,97] 145 [5,71] 121 [4,76] 96 [3,78] 70 [2,75] [5075] [870/5075] [2100]
Steel body (on request aluminium body) Standard setting 350 bar [5075 PSI] to 5 l/m [1,32 USgpm] Standard setting 210 bar [3045 PSI] to 5 l/m [1,32 USgpm]
24 25
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
BSAY COUNTERBALANCE BSPP
SINGLE COUNTERBALANCE VALVES FOR OPEN CENTER
BSAY counterbalance valves (Gas thread) are used to keep a load locked, the built-in relief valve protects the system
from overpressure in the cylinder by draining the oil.
240 16 240 16
3/8
180 12 180 12 3/8
1/2 1/2
120 8 1/4 120 8
1/4
60 4 60 4
0 0 0 0
0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
(1,85 Max)
47 Max
47 Max
F F
P
CODE
C1 C2 C1 C2
H H
62200021
G G
(0 8,5
(0 8,5
3)
3)
,3
,3
E E ORDERING CODE
0 0 0 0
V1 V1 V2 V2
MAX FLOW MAX STANDARD INCREASE TO
(0,88)
(0,88)
(2,01)
(2,01)
0
0
0
B
L
C
22,5
22,5
51
210 30/210 80
FA1013 BSA1B21YA
1/4 30 [3045] [435/3045] [1160] 1,05
BSPP [7,9] 350 60/350 135 [2,3]
TECHNICAL CHARACTERISTICS mm [Inches] FA1014 BSA1B35YA
[5075] [870/5075] [1960]
210 30/210 80
FA1015 BSA2B21YA
3/8 40 350 [3045] [435/3045] [1160] 1
F B H L P C E G 1:4,25
BSPP [10,6] [5075] 350 60/350 135 [2,2]
FA1016 BSA2B35YA
[5075] [870/5075] [1960]
1/4 BSPP 210 30/210 80
25 [0,98] 50 [1,97] 95 [3,74] 66 [2,26] 81 [3,19] 5,5 [0,22] 44,5 [1,73] FA1017 BSA3B21YA
1/2 60 [3045] [435/3045] [1160] 1,2
3/8 BSPP
BSPP [15,9] 350 60/350 135 [2,65]
FA1018 BSA3B35YA
1/2 BSPP 30 [1,18] 60 [2,36] 105 [4,13] 70 [2,76] 89 [3,19] 8,5 [0,33] 51,5 [2,03] [5075] [870/5075] [1960]
Steel body Standard setting 350 bar [5075 PSI] to 5 l/m [1,32 USgpm] Standard setting 210 bar [3045 PSI] to 5 l/m [1,32 USgpm]
26 27
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
BSC COUNTERBALANCE BSPP
SINGLE COUNTERBALANCE VALVES FOR CLOSED CENTER
BSC counterbalance valves (Gas thread) are used to keep a load locked, the built-in relief valve protects the system
from overpressure in the cylinder by draining the oil.
C2 C1
F H L M P Q R S
1/4 BSPP
50 [1,97] 95 [3,74] 81 [3,19] 23 [0,91] 66 [2,60] 43 [1,70] 7 [0,28]
3/8 BSPP
1/2 BSPP 60 [2,36] 100 [3,94] 84 [3,31] 21 [0,83] 67,5 [2,66] 50 [1,97] 10 [0,39]
V2 V1
PERFORMANCES
240 16 240 16
3/8
180 12 180 12 3/8
1/2 1/2
120 8 1/4 120 8
1/4
60 4 60 4
0 0 0 0
0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
(1,18)
(2)
51
0
P
0
C1 C2
0 0
ORDERING CODE
S
210 30/210 80
0
L
210 30/210 80
FA1023 BSC3B21
60 [3045] [435/3045] [1160] 1,28
1/2 BSPP
[15,9] 350 60/350 135 [2,84]
FA1024 BSC3B35
[5075] [870/5075] [1960]
Standard setting 350 bar [5075 PSI] to 5 l/m [1,32 USgpm] Standard setting 210 bar [3045 PSI] to 5 l/m [1,32 USgpm]
28 29
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
BSI COUNTERBALANCE BSPP
SINGLE COUNTERBALANCE VALVES FOR OPEN CENTER, SINGLE FLANGED VERSION
The BSI counterbalance valves (Gas thread) allow you to keep a load locked, the built-in relief valve protects the
system from overpressure in the cylinder by sending the oil to drain.
240 16 240 16
3/8
180 12 180 12
1/2 3/8 1/2
120 8 1/4 120 8 1/4
60 4 60 4
0 0 0 0
0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
(3,94)
(2,56)
(2,56)
(1,38)
(1,38)
35,8
35,8
(1,41)
(1,41)
100
100
65
65
35
35
29,5
29,5
(1,16)
(1,16)
F F
0
0
0
V2 V2 V1 V1 CODE
0 0 0 0
62200021
15 15
(0,59) (0,59)
C1 C1
(0
(0
8, 3)
8, 3)
5
5
,3
,3
45 45
(1,77) (1,77)
ORDERING CODE
60 60
(2,36) (2,36)
V2 V2 V1 V1
(1,97)
(1,97)
0
50P
P
M
M
50
210 30/210 80
FA1027 BSI1B21
30 [3045] [435/3045] [1160] 1,30
1/4 BSPP
[7,9] 350 60/350 135 [2,9]
TECHNICAL CHARACTERISTICS mm [Inches] FA1028 BSI1B35
[5075] [870/5075] [1960]
Steel body (on request aluminium body) Standard setting 350 bar [5075 PSI] to 5 l/m [1,32 USgpm] Standard setting 210 bar [3045 PSI] to 5 l/m [1,32 USgpm]
30 31
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
BSL COUNTERBALANCE BSPP
SINGLE COUNTERBALANCE VALVES FOR CLOSED CENTER, SINGLE FLANGED VERSION
The BSL counterbalance valves (Gas thread) allow you to keep a load locked, the built-in relief valve protects the
system from overpressure in the cylinder by sending the oil to drain.
C1 V2
F M P
1/4 BSPP
80 [3,15] 20 [0,78]
3/8 BSPP
V1 V2
PERFORMANCES
240 16 240 16
3/8
180 12 180 12
1/2 3/8 1/2
120 8 1/4 120 8 1/4
60 4 60 4
(2,56)
(2,56)
(3,93)
(3,93)
(2,24)
(2,24)
0 0 0 0
(1,38)
(1,38)
100
100
65
65
35
35
30 40 30 40
57
57
0 10 20 50 60 l/min 0 10 20 50 60 l/min
29,5
29,5
(1,16)
(1,16)
F F
0
V2 V2 V1 V1
0 0 0 0
ORDERING CODE
15 15
(0,59) (0,59)
MAX FLOW MAX STANDARD INCREASE TO
F RANGE SPRING PILOT WEIGHT
CODE TYPE l/min PRESSURE SETTING TURN
C1 C1 ports bar [PSI] RATIO kg [lb]
(0
(0
8, 3)
8, 3)
5
,3
,3
45 45
(1,77) (1,77) 210 30/210 80
FA1033 BSL1B21
30 [3045] [435/3045] [1160] 1,36
60 60 1/4 BSPP
[7,9] [3]
(2,36) (2,36) 350 60/350 135
FA1034 BSL1B35
V2 V2 V1 V1 [5075] [870/5075] [1960]
(1,97)
(1,97)
0
0
P
P
M
210 30/210 80
50
50
210 30/210 80
FA1037 BSL3B21
60 [3045] [435/3045] [1160] 1,70
1/2 BSPP
[15,9] 350 60/350 135 [3,74]
FA1038 BSL3B35
[5075] [870/5075] [1960]
Standard setting 350 bar [5075 PSI] to 5 l/m [1,32 USgpm] Standard setting 210 bar [3045 PSI] to 5 l/m [1,32 USgpm]
32 33
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
BDA COUNTERBALANCE BSPP
DOUBLE COUNTERBALANCE VALVES FOR OPEN CENTER
BDA counterbalance valves (Gas thread) are used to keep a load locked, the built-in relief valve protects the system
from overpressure in the cylinder by draining the oil.
300 20
1/2 1 300 20
0 10 20 30 40 USgpm 0 10 20 30 40 USgpm
V1 V2
TAMPER PROOF CAP M10
(1,85 Max)
(1,85 Max)
CODE
47 Max
47 Max
62200021
D
F F
L
L
B
C1 C1 C2 C2
0 0 0 0 ORDERING CODE
R R
S S 210 30/210 80
FA2001 BDA1B21
H H 30 [3045] [435/3045] [1160] 1,80
1/4 BSPP
V1 V1 V2 V2 [7,9] 350 60/350 135 [4]
FA2002 BDA1B35
[5075] [870/5075] [1960]
0
0
C
M
P
P
N
210 30/210 70
FA2007 BDA4B21
110 [3045] [435/3045] [966] 4,30
1/4 BSPP 3/4 BSPP
50 [1.97] 23 [0,91] 127 [5] 6 [0,24] 44 [1,75] [28,9] 350 60/350 145 [9,46]
FA2008 BDA4B35
3/8 BSPP 30 [1,18] 75 [2,95] 8,2 [0,32] 150 [5,90] 51 [2,01] 99 [3,9] [5075] [870/5075] [2100]
1:6,2
1/2 BSPP 60 [2,36] 21 [0,83] 129 [5,08] 8,5 [0,33] 51,5 [2,03] 210 30/210 70
FA2009 BDA5B21
160 [3045] [435/3045] [966] 6,8
1 BSPP
3/4 BSPP 70 [2,75] 40 [1,57] 9 [0,35] 61 [2,4] [42,1] 350 60/350 145 [15]
26 [1,02] 105 [4,13] 10,5 [0,41] 210 [8,27] 184 [7,24] 71 [2,78] 139 [5,47] FA2010 BDA5B35
[5075] [870/5075] [2100]
1 BSPP 80 [3,15] 50 [1,97] 10 [0,39] 70 [2,75]
Standard setting 350 bar [5075 PSI] to 5 l/m [1,32 USgpm] Standard setting 210 bar [3045 PSI] to 5 l/m [1,32 USgpm]
Steel body (on request aluminium body)
34 35
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
BDAY COUNTERBALANCE BSPP
DOUBLE COUNTERBALANCE VALVES FOR OPEN CENTER
BDAY counterbalance valves (Gas thread) are used to keep a load locked, the built-in relief valve protects the system
from overpressure in the cylinder by draining the oil.
C V V C
C1 C2 PSI bar PSI bar
300 20 300 20
240 16 240 16
3/8 3/8
180 12 180 12
1/2 1/2
120 8 1/4 120 8 1/4
60 4 60 4
0 0 0 0
0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
V1 V2
197 Max
47 Max
(5,59)
(2,95)
(5,91)
(0,31)
CODE
150
142
75
8
F
0
C1 C2
8,5 3)
(0
H 62200021
,3
R
Q
P
0 0 ORDERING CODE
V1 V2
(0.88)
(3,90)
(5,02)
(5,91)
(2,01)
0
127,5
22,5
0
150
B
99
51
210 30/210 80
FA2011 BDA1B21YA
30 [3045] [435/3045] [1160] 1,8
1/4 BSPP
[7,9] 350 60/350 135 [4]
FA2012 BDA1B35YA
TECHNICAL CHARACTERISTICS mm [Inches] [5075] [870/5075] [1960]
210 30/210 80
FA2013 BDA2B21YA
40 [3045] [435/3045] [1160] 350 1,72
3/8 BSPP 1:4,25
[10,6] 350 60/350 135 [5075] [3,8]
F B H P Q R FA2014 BDA2B35YA
[5075] [870/5075] [1960]
210 30/210 80
1/4 BSPP FA2015 BDA3B21YA
60 [3045] [435/3045] [1160] 2
25 [0,98] 50 [1.97] 5,5 [0,22] 40,5 [1,59] 44,5 [1,75] 1/2 BSPP
3/8 BSPP [15,9] 350 60/350 135 [4,4]
FA2016 BDA3B35YA
[5075] [870/5075] [1960]
1/2 BSPP 30 [1,18] 60 [2,36] 8,5 [0,33] 46,5 [1,83] 51,5 [1,03]
Standard setting 350 bar [5075 PSI] to 5 l/m [1,32 USgpm] Standard setting 210 bar [3045 PSI] to 5 l/m [1,32 USgpm]
Steel body
36 37
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
BDC COUNTERBALANCE BSPP
DOUBLE COUNTERBALANCE VALVES FOR CLOSED CENTER
BDC counterbalance valves (Gas thread) are used to keep a load locked, the built-in relief valve protects the system
from overpressure in the cylinder by draining the oil.
C1 C2
F H R S C M
1/4 BSPP
50 [1,97] 6 [0,24] 44 [1,73] 23 [0,91] 127 [5]
3/8 BSPP
1/2 BSPP 60 [2,36] 8,5 [0,33] 51,5 [2,03] 21 [0,83] 129 [5,08]
V1 V2
PERFORMANCES
240 16 240 16
3/8
180 12 180 12
1/2 3/8 1/2
120 8 1/4 120 8
1/4
60 4 60 4
0 0 0 0
0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
(5,91)
(8,15)
207
150
57
75
F
(1,18)
0
30
ORDERING CODE
0
C1 C2
0 0
R
MAX FLOW STANDARD RANGE INCREASE TO MAX
F PILOT WEIGHT
CODE TYPE l/min SETTING SPRING TURN PRESSURE
ports RATIO kg [lb]
[USgpm] bar [PSI] bar [PSI] bar [PSI] bar [PSI]
8,2 )
2
(0,3 210 30/210 80
S FA2017 BDC1B21
H
[3045] [435/3045] [1160]
1/4 BSPP 30 [7,9] 1,9 [4,2]
V1 V2 350 60/350 135
FA2018 BDC1B35
[5075] [870/5075] [1960]
(3,10)
(2)
0
51
M
99
210 30/210 80
FA2021 BDC3B21
[3045] [435/3045] [1160]
1/2 BSPP 60 [15,9] 2,10 [4,6]
350 60/350 135
FA2022 BDC3B35
[5075] [870/5075] [1960]
Standard setting 350 bar [5075 PSI] to 5 l/m [1,32 USgpm] Standard setting 210 bar [3045 PSI] to 5 l/m [1,32 USgpm]
38 39
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
BFA COUNTERBALANCE BSPP
DOUBLE COUNTERBALANCE VALVES FOR OPEN CENTER, FLANGED VERSION
BFA counterbalance valves (Gas thread) are used to keep a load locked, the built-in relief valve protects the system
from overpressure in the cylinder by draining the oil.
240 16 240 16
3/8
180 12
1/2
180 12 3/8
1/2
120 8 1/4 120 8 1/4
60 4 60 4
0 0 0 0
0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
V1 V2
F
(7,76)
(5,91)
(3,90)
(2,01)
CODE
150
197
51
99
60 V2 V1
62200021
(2,36)
50
8,5 (1,97)
(0,33
)
9
)
C2 (0,35 C1
10 ORDERING CODE
(0,37)
0 0
210 30/210 80
FA2023 BFA1B21
30 [3045] [435/3045] [1160] 2,05
1/4 BSPP
[7,9] 350 60/350 135 [4,52]
TECHNICAL CHARACTERISTICS mm [Inches] FA2024 BFA1B35
[5075] [870/5075] [1960]
Steel body (on request aluminium body) Standard setting 350 bar [5075 PSI] to 5 l/m [1,32 USgpm] Standard setting 210 bar [3045 PSI] to 5 l/m [1,32 USgpm]
40 41
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
BFC COUNTERBALANCE BSPP
DOUBLE COUNTERBALANCE VALVES FOR CLOSED CENTER, FLANGED VERSION
BFC counterbalance valves (Gas thread) are used to keep a load locked, the built-in relief valve protects the system
from overpressure in the cylinder by draining the oil.
C1 C2
F C D
1/4 BSPP
23 [0,91] 127 [5]
3/8 BSPP
V1 V2
PERFORMANCES
240 16 240 16
0 0 0 0
0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
F
(8,15)
(5,91)
(3,90)
(2,01)
(2,24)
207
150
51
99
57
ORDERING CODE
0
V2 V1
60
(2,36)
50
8,5 (1,97)
(0,33) MAX FLOW MAX STANDARD INCREASE TO
F RANGE SPRING PILOT WEIGHT
CODE TYPE l/min PRESSURE SETTING TURN
ports bar [PSI] RATIO kg [lb]
[USgpm] bar [PSI] bar [PSI] bar [PSI]
9
)
C2 (0,35 C1 210 30/210 80
10 FA2029 BFC1B21
30 [3045] [435/3045] [1160] 2,15
(0,37) 1/4 BSPP
0 0 [7,9] 350 60/350 135 [4,74]
FA2030 BFC1B35
O-Ring 10,77 x 2,62 [5075] [870/5075] [1960]
29,5
(1,16)
0
210 30/210 80
FA2033 BFC3B21
60 [3045] [435/3045] [1160] 2,05
1/2 BSPP
[15,9] 350 60/350 135 [4,52]
FA2034 BFC3B35
[5075] [870/5075] [1960]
Standard setting 350 bar [5075 PSI] to 5 l/m [1,32 USgpm] Standard setting 210 bar [3045 PSI] to 5 l/m [1,32 USgpm]
42 43
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
BCA COUNTERBALANCE CETOP3
DOUBLE COUNTERBALANCE VALVES, CETOP 3 FOR OPEN CENTER
Counterbalance valves are used to keep a load locked, the built-in relief valve protects the system from overpressu-
re in the cylinder by draining the oil.
PSI bar
A1 P T B1 300 20
240 16
A1/B1 A/B
A/B A1/B1
180 12
120 8
60 4
0 0
0 10 20 30 40 50 60 l/min
94,5
0
0
7 6,25
P (0,25)
12,1
(0,28) (0,48) CODE
A1
22,5
(0,88)
B1 62200021
38 38,75 32,9
(1,50) T (1,53) (1,29)
45
(1,77)
(2,63)
(2,97)
(3,32)
66,8
0
84,3
75,5
A B
0
ORDERING CODE
198 Max
0
(1,85)
(7,79)
151
Standard setting 350 bar [5075 PSI] to 5 l/m [1,32 USgpm] Standard setting 210 bar [3045 PSI] to 5 l/m [1,32 USgpm]
44 45
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
BCC COUNTERBALANCE CETOP3
DOUBLE COUNTERBALANCE VALVES, CETOP 3 FOR CLOSED CENTER
Counterbalance valves are used to keep a load locked, the built-in relief valve protects the system from overpressure
in the cylinder by draining the oil.
PSI bar
A1 P T B1 300 20
240 16
A1/B1 A/B
A/B A1/B1
180 12
120 8
60 4
0 0
0 10 20 30 40 50 60 l/min
94,5
54
0
0
0
7 6,25
P (0,25)
12,1
(0,28) (0,48)
A1
22,5 ORDERING CODE
(0,88)
B1
38 38,75 32,9
(1,50) T (1,53) (1,29)
MAX FLOW MAX STANDARD INCREASE TO
45 F RANGE SPRING PILOT WEIGHT
(1,77) CODE TYPE l/min PRESSURE SETTING TURN
ports bar [PSI] RATIO kg [lb]
(2,63)
(2,97)
(3,32)
84,3
75,5
Standard setting 350 bar [5075 PSI] to 5 l/m [1,32 USgpm] Standard setting 210 bar [3045 PSI] to 5 l/m [1,32 USgpm]
59
(2,32)
6
O-Ring 8,73x1,78 (0,24)
(5,94)
(2,24)
(8,19)
0
208
57
151
mm [Inches]
46 47
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
UFC CHECK VALVES BSPP
CHECK VALVES
The UFC (Gas thread) check valves allow the full flow of oil in one direction and stop the flow in the opposite direction.
The applications where these valves can be used are many, agricultural machinery or industrial installations.
75 5 3/4
60 4
1-1/2
2 1 60 4 1/2
3/8 45 3
45 3 1-1/4
30 2
30 2
1/4 1
15 1
15 1
0 0 0 0
0 20 40 60 80 100 120 l/min 0 50 100 150 200 250 300 350 l/min
2 1
F
ORDERING CODE
Steel body On request (only for poppet type) FA3024 UFS3B05 1/2 BSPP 70[18,5] 0,23 [0,50]
• Calibration hole
48 49
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
UMC CHECK VALVES BSPP
CHECK VALVES
The UMC (Gas thread) check valves allow the full flow of oil in one direction and stop the flow in the opposite di-
rection. The applications where these valves can be used are many, agricultural machinery or industrial installations.
F L A HEX
PERFORMANCES
PSI bar 1 2
75 5
60 4
1/2
45 3
3/8
30 2
1/4
15 1
A A
0 0
0 10 20 30 40 50 l/min
ORDERING CODE
2 1
F
On request
3 [43,5] 0,11
FA3029 UMC3B05 1/2 BSPP 50 [13,2] 60 [44,3] 50 [36,8]
6 [87] [0,24]
mm [Inches]
0,03
FA3032 UMS1B05 1/4 BSPP 10 [2,64] 30 [22,2] 20 [14,75]
[0,07]
Ball type
500 0,18
FA3033 UMS2B05 3/8 BSPP 30 [7,92] 45 [33,2] 35 [25,8]
[7250] 0,5 [0,40]
[7,3]
0,23
FA3034 UMS3B05 1/2 BSPP 50 [13,2] 60 [44,3] 50 [36,8]
[0,50]
50 51
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
VUC CHECK VALVES BSPP
CHECK VALVES POPPET TYPE
The VUC check valve allow the free flow through in a direction while the flow is blocked in the opposite one. It is sui-
table for integrated circuits mounted on hydraulic blocks. The unidirectional check valve is useful where the design
requires small size valve. The external seal is ensured by an o-ring.
PSI bar 2 1
180 12
150 10
1/2
1 2 120 8 1/4 3/8
3/4
90 6
CODE TYPE 1/8
60 4
CHI08 VUC0B 30 2
CHI09 VUC1B 0 0
0 20 40 60 80 100 120 l/min
CHI010 VUC2B
0 5 10 15 20 25 30 USgpm
CHI011 VUC3B
CHI012 VUC4B
D
A
0
1 2
C
F
ORDERING CODE
F L A C D 0,002
FA3035 VUC0B FC119 1/8 BSPP 10 [2,65] 6 [4,4]
[0,004]
0,005
1/8 BSPP 7,5 [0,29] 3,5 [0,13] 5,6 [0,22] 1,6 [0,06] FA3036 VUC1B FC111 1/4 BSPP 20 [5,3] 15 [11]
[0,011]
1/2 BSPP 12,7 [0,5] 6,5 [0,25] 13,5 [0,53] 3,8 [0,15] 0,040
FA3039 VUC4B FC114 3/4 BSPP 120 [31,66] 50 [37]
[0,088]
3/4 BSPP 14,8 [0,58] 7,6 [0,3] 16,5 [0,65] 5 [0,19] See cavity paragraph p. 205
52 53
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
Max leakage: 0,25 cm3/min - 5 drops/min | Cracking pressure: 0,5 bar 7,25 PSI
VUD CHECK VALVES BSPP
CHECK VALVES POPPET TYPE
The VUD check valve allow the free flow through in a direction while the flow is blocked in the opposite one. It is sui-
table for integrated circuits mounted on hydraulic blocks. The unidirectional check valve is useful where the design
requires small size valve. The external seal is ensured by an o-ring.
HYDRAULIC CIRCUIT
F L A HEX
PERFORMANCES
PSI bar 2 1
304 21
261 18
3/8
217 15 1/8
3/4
174 12 1/2
1/4
139 9
87 6
43 3
0 0
0 20 40 60 80 100 120 l/min
HEX
A
0
0 5 10 15 20 25 30 USgpm
ORDERING CODE
1 2 TIGHTENING CRACKING
F
10 9 0,003
FA3040 VUD0B FC120 1/8 BSPP
[2,65] [6,6] [0,007]
20 15 0,007
FA3041 VUD1B FC107 1/4 BSPP
[5,3] [11] [0,015]
80 40 0,023
FA3043 VUD3B FC109 1/2 BSPP
[21,11] [29,5] [0,05]
120 50 0,050
FA3044 VUD4B FC110 3/4 BSPP
[31,66] [37] [0,11]
54 55
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
Max leakage: 0,25 cm3/min - 5 drops/min | Cracking pressure: 0,5 bar 7,25 PSI
VUS CHECK VALVES BSPP
CHECK VALVES BALL TYPE
The VUS check valve allow the free flow through in a direction while the flow is blocked in the opposite one. It is sui-
table for integrated circuits mounted on hydraulic blocks. The check valve is useful where the design requires small
size valve. The external seal is ensured by an o-ring.
F L A C D HEX T O-RING
1/2 BSPP 22,5 [0,88] 7[0,28] 10 [0,39] 2,5 [0,1] 6 HEX 5 14 x 1,78
PERFORMANCES
PSI bar 2 1
120 8
3/8 3/4
90 6
1/2
1/4
60 4
O-RING
HEX T
30 2
0
0 0
0 10 20 30 40 50 60 70 80 l/min
1 2
C
F
ORDERING CODE
TIGHTENING CRACKING
F MAX FLOW MAX PRESSURE WEIGHT
CODE TYPE CAVITY TORQUE PRESSURE
A A ports l/min [USgpm ] bar [PSI]
Nm [lbt ft] bar [PSI]
kg [lb]
D
20 4 0,01
FA3045 VUS1B FC107 1/4 BSPP
[5,3] [3] [0,022]
30 6 0,018
It’s possible to install the valve in both directions FA3046 VUS2B FC108 3/8 BSPP
[7,9] 350 [4,4] 0,5 [0,040]
[5075] [7,3]
50 10 0,033
FA3047 VUS3B FC109 1/2 BSPP
[13,2] [7,4] [0,073]
mm [Inches]
80 20 0,082
FA3048 VUS4B FC110 3/4 BSPP
[21] [14,8] [0,18]
56 57
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
Max leakage: 0,25 cm3/min - 5 drops/min | Cracking pressure: 0,5 bar 7,25 PSI
F1B FLOW CONTROL 1/4 BSPP
1/4 BSPP FLOW CONTROL VALVES - PRESSURE COMPENSATED
The fixed compensated flow control valve F1B (1/4 G) is used to keep the descent speed of a load constant, regard-
less of the operating pressure and the value of the load. Typical use is related to tail lifts and hydraulic platforms.
CODE CODE
HYDRAULIC CIRCUIT
33300011 33300027
52 11
(2,12)
54
(2,04) (0,43)
0
1/4 BSPP
1 2
BSPP 1/4
BSPP 1/4
HEX 19 HEX 19
ORDERING CODE
1 1
FA4001 F1B01
[0,26] [0,04]
2 1,2
FA4002 F1B02
[0,53] [0,05]
FLOW FLOW 3 1,5
CONTROL CONTROL FA4003 F1B03
[0,79] [0,06]
ØH ØH 4 1,7
FA4004 F1B04
[1,06] [0,07]
(0,06)
(0,06)
1,5
1,5
5 1,9
FA4005 F1B05
[1,32] [0,07]
BSPP 1/4
BSPP 1/4
2 2 1 1 6 2,1
FA4006 F1B06 FC105 [1,58] [0,08]
1/4 BSPP
7 2,3 250 4 0,014
FA4007 F1B07
See cavity [1,85] [0,09] [3625] [3] [0,031]
paragraph
p. 204 8 2,4
(0,43)
(0,43)
FA4008 F1B08
(1,04)
(1,04)
(0,2)
(0,2)
0
0
26,5
26,5
[2,11] [0,09]
5
5
11
11
9 2,7
FA4009 F1B09
[2,38] [0,11]
10 2,8
mm [Inches] FA4010 F1B10
[2,64] [0,11]
11 3,1
FA4011 F1B11
[2,90] [0,12]
12 3,3
FA4012 F1B12
[3,17] [0,13]
15 5
FA4013 F1B15
[3,96] [0,20]
58 59
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
F1T FLOW CONTROL 1/4 BSPP
1/4 BSPP FLOW CONTROL VALVES - PRESSURE COMPENSATED - DOUBLE CUT
The fixed compensated flow control valve F1T (1/4 G) is used to keep the descent speed of a load constant, regardless
of the operating pressure and the value of the load. Typical use is related to tail lifts and hydraulic platforms.
CODE CODE
HYDRAULIC CIRCUIT
33300011 33300027
52 11
(2,12)
54
(2,04) (0,43)
0
1/4 BSPP
1 2
BSPP 1/4
BSPP 1/4
HEX 19 HEX 19
ORDERING CODE
1 1
FA4067 F1T01
[0,26] [0,04]
2 1,2
FA4068 F1T02
[0,53] [0,05]
FLOW FLOW 3 1,5
CONTROL FA4069 F1T03
CONTROL [0,79] [0,06]
ØH ØH 4 1,7
FA4070 F1T04
(0,06)
[1,06] [0,07]
(0,06)
(0,06)
(0,06)
1,5
1,5
1,5
1,5
5 1,9
FA4071 F1T05
BSPP 1/4
BSPP 1/4
[1,32] [0,07]
2 2 1 1 6 2,1
FA4072 F1T06 FC105 [1,58] [0,08]
1/4 BSPP
7 2,3 250 4 0,014
FA4073 F1T07
See cavity [1,85] [0,09] [3625] [3] [0,031]
paragraph
8 2,4
(0,43)
p. 204
(0,2)
(0,43)
(1,04)
(0,2)
26,5
(1,04)
FA4074 F1T08
0
26,5
50
[2,11] [0,09]
511
11
9 2,7
FA4075 F1T09
[2,38] [0,11]
10 2,8
mm [Inches] FA4076 F1T10
[2,64] [0,11]
11 3,1
FA4077 F1T11
[2,90] [0,12]
12 3,3
FA4078 F1T12
[3,17] [0,13]
15 5
FA4079 F1T15
[3,96] [0,20]
60 61
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
F1C FLOW CONTROL Ø 12,7
D. 12.7 FLOW CONTROL VALVES-PRESSURE COMPENSATED
The fixed compensated flow control valve F1C (d. 12.7) is used to keep the descent speed of a load constant, regard-
less of the operating pressure and the value of the load.
CONTROLLED FLOW AT
ØH MAX PRESSURE WEIGHT
CODE TYPE 100 bar ± 10%
mm [Inches] bar [PSI] kg [lb]
l/min [USgpm]
1 1
1 2 FA4080 F1C01
[0,26] [0,04]
2 1,2
FA4081 F1C02
[0,53] [0,05]
3 1,5
FA4082 F1C03
[0,79] [0,06]
4 1,7
FA4083 F1C04
[1,06] [0,07]
5 1,9
FA4084 F1C05
[1,32] [0,07]
6 2,1
FA4085 F1C06
[1,58] [0,08]
8 2,4
FA4087 F1C08
[2,11] [0,09]
9 2,7
FA4088 F1C09
[2,38] [0,11]
10 2,8
FA4089 F1C10
[2,64] [0,11]
FLOW
FLOW FA4090 F1C11
11 3,1
CONTROL [2,90] [0,12]
CONTROL
ØH 12 3,3
ØH FA4091 F1C12
12,7 12,7 [3,17] [0,13]
(0,50)
(0,50) 15 5
FA4092 F1C15
[3,96] [0,20]
22 1 1
0 0
(0,98)
(0,04)
(0,04)0
(0,29)
(0,98)
0
(0,29)
25
7,4
1
25
7,4
mm [Inches]
62 63
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
F2B FLOW CONTROL 3/8 BSPP
3/8 BSPP FLOW CONTROL VALVES - PRESSURE COMPENSATED
The fixed compensated flow control valve F2B (3/8 G) is used to keep the descent speed of a load constant, regard-
less of the operating pressure and the value of the load. Typical use is related to tail lifts and hydraulic platforms.
CODE CODE
HYDRAULIC CIRCUIT
33300028 33300029
54 13
(2,48)
(2,12) (0,51)
63
0
3/8 BSPP
1 2
BSPP 3/8
BSPP 3/8
HEX 22 HEX 22
ORDERING CODE
1 0,6
FA4014 F2B01
[0,26] [0,02]
2 1,4
FA4015 F2B02
[0,53] [0,06]
3 1,7
FA4016 F2B03
[0,79] [0,07]
FLOW
CONTROL
FLOW 4 2,1
CONTROL FA4017 F2B04
[1,06] [0,08]
ØH
ØH 5 2,3
FA4018 F2B05
(0,06)
[1,32] [0,09]
(0,06)
1,5
1,5
6 2,6
BSPP 3/8
FA4019 F2B06
BSPP 3/8
22 1 1
FC106
[1,58] [0,10]
(0,16) 0
(1,1)
13,513,5
28
4
(0,53)
9 3,3
0
(1,1)
28
FA4022 F2B09
[2,38] [0,13]
10 3,5
FA4023 F2B10
[2,64] [0,14]
11 3,7
mm [Inches] FA4024 F2B11
[2,90] [0,15]
12 4
FA4025 F2B12
[3,17] 0,16]
16 5,2
FA4026 F2B16
[4,22] [0,2]
18 5,8
FA4027 F2B18
[4,75] [0,23]
64 65
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
VBA HOSE BURST BSPP
HOSE BURST VALVES
The VBA hose burst are mounted directly on the cylinder to avoid an uncontrolled descent of the load in the event of
a hose break.
L
0
L
HEX
F
1 2
F F
CODE L HEX CODE L HEX
ports ports
33300026 1/4 BSPP 61 [2,40] 19 [0,75] 33300018 1/4 BSPP 39 [1,53] 19 [0,75]
33300028 3/8 BSPP 63 [2,48] 22 [0,87] 33300019 3/8 BSPP 45 [1,77] 22 [0,87]
TOOL PERFORMANCES
S
inch mm 2 1
0,12 3
3/4 1
0,08 2 1/2
3/8
1 2 WEIGHT 1/4
F
CODE TYPE
C
kg lbt 0,04 1
S
0
ORDERING CODE
TECHNICAL CHARACTERISTICS mm [Inches] FA6001 VBA1B FC100 1/4 BSPP 25 [6,6] 4 [3] 0,008 [0,017]
1 [0,7]
FA6002 VBA2B FC101 3/8 BSPP 50 [13,2] 6 [4,5] 0,014 [0,030]
F C D L
FA6003 VBA3B FC102 1/2 BSPP 80 [21,1] 350 [5075] 10 [7,5] 0,025 [0,055]
1/4 BSPP 8 [0,31] 2,5 [0,10] 8,2 [0,32]
FA6004 VBA4B FC103 3/4 BSPP 150 [39,6] 15 [11] 2 [1,5] 0,05 [0,11]
3/8 BSPP 10 [0,39] 3,25 [0,13] 11 [0,43]
1/2 BSPP 11,5 [0,45] 4 [0,16] 13 [0,51] FA6005 VBA5B FC104 1 BSPP 180 [47,5] 20 [15] 0,10 [0,22]
3/4 BSPP 14,5 [0,57] 5,2 [0,20] 18 [0,70] S setting on request - hole on the plate on request
66 67
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
Max leakage in the version without hole: 0,25 cm3/min - 5 drops/min
VBAT HOSE BURST BSPP
HOSE BURST VALVES
The VBAT hose burst are mounted directly on the cylinder to avoid an uncontrolled descent of the load in the event of
a hose break.
F M D L HEX A B
24 21 [0,82]
M22x 1,5 15 [0,59]
1/2 BSPP 13 [0,51] 27 9,5 [0,37] 21,5 [0,84]
PERFORMANCES
S
inch mm 1 2
0,12 3
0,08 2
1/2
3/8
0,04 1
HEX
0 0
S 0 10 20 30 40 50 60 70 80 90 l/min
1 2
D
F
M
ORDERING CODE
TORQUE OF TORQUE OF
MAX TORQUE OF
F MAX FLOW TIGHTENING ADJUSTMENT SCREW WEIGHT
CODE TYPE PRESSURE TIGHTENING
ports l/min [USgpm] TUBE TIGHTENING kg [lb]
bar [PSI] Nm [lbt ft]
Nm [lbt ft] Nm [lbt ft]
20
0
B
L
A
FA6006 VBA2BT10
[15] 0,044
50 30 1 [0,097]
mm [Inches] 40
FA6007 VBA2BT12 3/8 BSPP
[13.2] 320 [22] [30] [0,7]
[4641]
0,060
FA6008 VBA2BT15
60 [0,13]
80 50 [45] 2 0,077
FA6009 VBA3BT15 1/2 BSPP
[21.1] [37] [1,5] [0,17]
68 69
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
Max leakage in the version without hole: 0,25 cm3/min - 5 drops/min
CFR FLOW CONTROL BSPP
FLOW CONTROL VALVES-PRESSURE COMPENSATED
Compensated flow control valve, allows the free passage of oil in one direction and regulates the flow in the opposite
direction. The internal compensation system keeps the actuator speed constant, regardless of the load, and guaran-
tees high adjustment sensitivity.
F L H E
1/4 BSPP
87,5 [3,44] 66 [2,60] 36,5 [1,44]
1 2 3/8 BSPP
Steel body
PERFORMANCES
150 10 75 5
1/4 3/8
H H 120 8
3/8
60 4
1/4
90 6 45 3 1/2
60 4
1/2 30 2
30 2 15 1
0 0 0 0
0 10 20 30 40 50 l/min 0 10 20 30 40 50 l/min
1 1 2 2
F
0 0 ORDERING CODE
25
FA4028 CFR1B 1/4 BSPP
[6,6] 0,5
30 250 [1,10]
FA4029 CFR2B 3/8 BSPP
[7,9] [3625]
45 0,8
FA4030 CFR3B 1/2 BSPP
[12] [1,76]
70 71
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
SUA FLOW CONTROL BSPP
UNIDIRECTIONAL FLOW CONTROL VALVES
The unidirectional flow control valves SUA (Gas thread) allow the free passage of the oil in one direction and regulate
it in the opposite direction.
F L H ØD A
Steel body
PERFORMANCES
105 7 105 7
1/4 1/2 1
3/8
90 6 90 6 3/4
D D 75 5 75 5
60 4 3/8 60 4
H (Min) H (Min) 1
45 3
1/2 3/4 45 3
1/4
30 2 30 2
15 1 15 1
0 0 0 0
0 30 60 90 120 150 180 l/min 0 30 60 90 120 150 180 l/min
A A
ORDERING CODE
CODE TYPE
ports l/min [USgpm] bar [PSI] kg [lb]
0 0
25
FLOW FLOW FA4031 SUA1B 1/4 BSPP
[6,6] 0,4
CONTROL CONTROL
0
0
L
35 [0,88]
mm [Inches] FA4032 SUA2B 3/8 BSPP
[9,3]
50 400 0,6
FA4033 SUA3B 1/2 BSPP
[13,2] [5800] [1,32]
90 1,45
FA4034 SUA4B 3/4 BSPP
[23,8] [3,2]
150 2
FA4035 SUA5B 1 BSPP
[39,6] [4,4]
72 73
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
SUD FLOW CONTROL - LOCK NUT BSPP
UNIDIRECTIONAL FLOW CONTROL VALVES
The unidirectional flow control valves SUD (Gas thread) allow the free passage of the oil in one direction and regulate
it in the opposite direction.
F L H
Steel body
PERFORMANCES
60 4
3/8 60 4
H (Min) H (Min) 45 3 45 3
1/2
30 2 1/4 30 2
15 1 15 1
0 0 0 0
0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
M20X1 M20X1
ORDERING CODE
2 2 1 1
F
0
0
[6,6]
L
50 0,55
FA4038 SUD3B 1/2 BSPP
[13,2] [1,21]
74 75
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
SBA FLOW CONTROL BSPP
BIDIRECTIONAL FLOW CONTROL VALVES
The bidirectional flow control valves SBA (Gas thread) regulate the speed of an actuator in both directions.
F L H ØD A
1/4 BSPP
2 1 54 [2,13] 76 [2,99] 25 [0,98]
3/8 BSPP 30 [1,18] M20 x 1
Steel body
PERFORMANCES
60 4 60 4
45 3 45 3
30 2 30 2
15 1 15 1
0 0 0 0
0 10 20 30 40 50 60 l/min 0 30 60 90 120 150 180 l/min
A A
ORDERING CODE
2 2 1 1
F
0 0
25 0,3
FA4039 SBA1B 1/4 BSPP
[6,6] [0,66]
0
0
0
0
L
35 0,31
FA4040 SBA2B 3/8 BSPP
mm [Inches] [9,3] [0,68]
50 400 0,5
FA4041 SBA3B 1/2 BSPP
[13,2] [5800] [1,1]
90 1,1
FA4042 SBA4B 3/4 BSPP
[23,8] [2,43]
150 1,5
FA4043 SBA5B 1 BSPP
[39,6] [3,3]
76 77
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
SBD FLOW CONTROL - LOCK NUT BSPP
BIDIRECTIONAL FLOW CONTROL VALVES
The bidirectional flow control valves SBD (Gas thread) regulate the speed of an actuator in both directions.
F L H
2 1 1/4 BSPP
54 [2,13] 74 [2,91] 25 [0,98]
3/8 BSPP
Steel body
PERFORMANCES
1 2
25 PSI bar
(0,98)
120 8
105 7 1/4
1/2
H (Min) 90 6
3/8
75 5
60 4
45 3
30 2
15 1
M20X1 0 0
0 10 20 30 40 50 60 l/min
2 1
F
ORDERING CODE
0
CODE TYPE
ports l/min [USgpm] bar [PSI] kg [lb]
mm [Inches]
78 79
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
VCU FLOW CONTROL BSPP
UNIDIRECTIONAL FLOW CONTROL VALVES
The unidirectional flow control valves VCU (Gas thread) allow the free passage of the oil in one direction and regulate
it in the opposite direction.
F ØD L
Steel body
PERFORMANCES
75 5 75 5
60 4 1/2 60 4
3/8
45 3
1/4 45 3
1/4 1/2
0
3/8
L
30 2 30 2
0 15 1 15 1
0 0 0 0
0 10 20 30 40 50 60 70 l/min 0 10 20 30 40 50 60 70 l/min
0 2,5 5 7,5 10 12,5 15 17,5 USgpm 0 2,5 5 7,5 10 12,5 15 17,5 USgpm
2 1
F
D
FLOW ORDERING CODE
CONTROL
F MAX FLOW MAX PRESSURE WEIGHT
CODE TYPE
ports l/min [USgpm] bar [PSI] kg [lb]
mm [Inches]
80 81
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
VCB FLOW CONTROL BSPP
BIDIRECTIONAL FLOW CONTROL VALVES
The bidirectional flow control valves VCB (Gas thread) regulate the speed of an actuator in both directions
F ØD L
Steel body
PERFORMANCES
PSI bar 2 1
90 6
75 5
60 4 1/2
3/8
45 3
1/4
0
30 2
0 15 1
0 0
0 10 20 30 40 50 60 70 l/min
2 1
F
D
FLOW ORDERING CODE
CONTROL
82 83
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
RCT FLOW CONTROL BSPP
3 WAYS FLOW CONTROL VALVES, PRESSURE COMPENSATED WITH EXCEEFING FLOW TO TANK
The 3-way flow control valves allow the regulation and constant maintenance of the flow regardless of the load, by
means of an internal compensation system, in the RCT version the excess flow goes to the drain.
F B H L ØD N C E S G Z A
P R 3/8 BSPP
40 [1,57] 90 [3,54] 90 [3,54] 6,5 [0,26] 54 [2,13] 31 [1,22] 6 [0,24] 73 [2,87] 40 [1,57] 70 [2,76] 134 [5,28]
1/2 BSPP
Aluminium body
PERFORMANCES
35 140
12,5 50
20 80
30 120
A 10 40
25 100
15 60
7,5 30 20 80
(1,36)
34,5
10 40
15 60
G
5 20
0
10 40
2,5 10 5 20
H 5 20
0 0 0 0 0 0
R 0 40 80 120 160 200 bar 0 40 80 120 160 200 bar 0 40 80 120 160 200 bar
S 0 560 1120 1680 2240 2800 PSI 0 560 1120 1680 2240 2800 PSI 0 560 1120 1680 2240 2800 PSI
D
N
P
C
ORDERING CODE
E
0 0 0 F MAX FLOW MAX PRESSURE WEIGHT
CODE TYPE
T ports l/min [USgpm] bar [PSI] kg [lb]
0
F
Z
0
L
E
84 85
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
RCP FLOW CONTROL BSPP
3 WAYS FLOW CONTROL VALVES, PRESSURE COMPENSATED WITH EXCEEFING FLOW TO PRESSURE
The 3-way flow control valves allow the regulation and constant maintenance of the flow regardless of the load, by
means of an internal compensation system, in the RCP version the excess flow it is under pressure available for a
second use.
F B H L ØD N C E T G Z A M
P 3/8 BSPP
40 [1,57] 70 [2,76] 130 [5,11] 6,5 [0,26] 64 [2,52] 28 [1,10] 6 [0,24] 82 [3,23] 45 [1,77] 120 [4,72] 114 [4,49] 10 [0,39]
1/2 BSPP
3/4 BSPP 50 [1,97] 90 [3,54] 155 [6,10] 9,5 [0,37] 80 [3,15] 35 [1,38] 10 [0,39] 98 [3,86] 54 [2,13] 145 [5,71] 135 [5,32] /
E R Aluminium body
PERFORMANCES
12,5 50
20 80
10 40
A 15 60
7,5 30
10 40
5 20
2,5 10 5 20
0
T
0 0 0 0
H -200 -120 -40 40 120 200 bar -200 -120 -40 40 120 200 bar
N
D 0 560 1120 1680 2240 2800 PSI 0 560 1120 1680 2240 2800 PSI
P
C
E P
0 0 0
E R ORDERING CODE
F
0
(1,44)
0
Z
L
36,5
86 87
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
VBD CHECK VALVES BSPP
DOUBLE ACTING PILOT CHECK VALVES
VBD pilot check valves are used to lock a double acting actuator in place in both directions, ensuring the load is
locked
C1 C2
F B H L M N P A C D
1/4 BSPP
30 [1,18] 40 [1,57] 63 [2,5] 16,5 [0,65] 46,5 [1,83] 7 [0,28] 22,5 [0,65] 85,5 [3,4] 31,5 [0,24]
3/8 BSPP
1/2 BSPP 35 [1,38] 50 [2,0] 82 [3,23] 23 [0,90] 59 [2,32] 15 [0,59] 31,5 [1,24] 113,5 [4,5] 41 [1,61]
V1 V2 Steel body
PERFORMANCES
75 5
1/2 120 8
60 4
3/8
3/8 90 6 1/4
45 3 1/2
1/4 60 4
30 2
30 2
15 1
C
C
A
A
0
F F 0 0
0 10 20 30 40 50 l/min
0 0
0 10 20 30 40 50 l/min
M8
M8
0
B
0 0
P P
C1 C1 C2 C2
F
H H ORDERING CODE
0
0
D
N
M
CRACKING
F MAX FLOW MAX PRESSURE WEIGHT
CODE TYPE PILOT RATIO PRESSURE
ports l/min [USgpm] bar [PSI] kg [lb]
bar [PSI]
mm [Inches]
FA5001 VBD1B 1/4 BSPP 20 [5,3] 0,65 [1,43]
1:5,5
350
FA5002 VBD2B 3/8 BSPP 35 [9,2] 4,5 [65] 0,6 [1,32]
[5075]
88 89
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
VBS CHECK VALVES BSPP
SINGLE ACTING PILOT CHECK VALVES
The VBS pilot check valves are used to lock a single acting actuator in position, ensuring that the load is locked.
C1 C2
F B H L M N P A C D
1/4 BSPP
30 [1,18] 40 [1,57] 63 [2,5] 16,5 [0,65] 46,5 [1,83] 7 [0,28] 22,5 [0,65] 85,5 [3,4] 31,5 [0,24]
3/8 BSPP
1/2 BSPP 35 [1,38] 50 [2,0] 82 [3,23] 23 [0,90] 59 [2,32] 15 [0,59] 31,5 [1,24] 113,5 [4,5] 41 [1,61]
V1 V2 Steel body
PERFORMANCES
75 5
1/2 120 8
60 4
3/8
3/8 90 6 1/4
45 3 1/2
1/4 60 4
30 2
30 2
15 1
C
C
A
A
0
F F
0 0 0 0
M8
M8
0
B
0 10 20 30 40 50 l/min 0 10 20 30 40 50 l/min
V1 V1 V2 V2
0 2,5 5 7,5 10 12,5 USgpm 0 2,5 5 7,5 10 12,5 USgpm
0 0
P P
C1 C1 C2 C2
F
H H ORDERING CODE
0
0
D
N
M
CRACKING
F MAX FLOW MAX PRESSURE WEIGHT
CODE TYPE PILOT RATIO PRESSURE
ports l/min [USgpm] bar [PSI] kg [lb]
bar [PSI]
mm [Inches]
FA5004 VBS1B 1/4 BSPP 20 [5,3] 0,61 [1,34]
1:5,5
350
FA5005 VBS2B 3/8 BSPP 35 [9,2] 4,5 [65] 0,58 [1,28]
[5075]
90 91
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
VBDT CHECK VALVES BSPP
DIN2353 DOUBLE ACTING PILOT CHECK VALVES
VBDT pilot check valves are used to lock a double acting actuator in position, ensuring that the load is locked. This
version was made for valve mounting with rigid tube.
75 5
120 8
3/8
60 4
3/8 90 6 1/4
45 3
1/4
60 4
30 2
30 2
15 1
V1 V2
0 0 0 0
0 10 20 30 40 l/min 0 10 20 30 40 l/min
ORDERING CODE
(2,48)
(1,24)
(1,32)
33,5
(3,8)
96,5
31,5
63
(2,48)
(1,24)
(1,32)
33,5
(3,8)
(1,18)
96,5
31,5
0
63
30
F
(1,18)
0
30
F CRACKING
0
(0,47)
(0,47)
(0,28) (0,28)
12
12
12
12
(1,83)
0
46,5
16,5
(0,65)
Steel body
(1,83)
0
46,5
16,5
mm [Inches]
92 93
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
VBST CHECK VALVES BSPP
DIN2353 SINGLE ACTING PILOT CHECK VALVES
VBST pilot check valves are used to lock a single acting actuator in position, ensuring that the load is locked. This
version was made for valve mounting with rigid tube.
75 5
120 8
3/8
60 4
3/8 90 6 1/4
45 3
1/4
60 4
30 2
30 2
15 1
V1 V2
0 0 0 0
0 10 20 30 40 l/min 0 10 20 30 40 l/min
ORDERING CODE
(1,24)
(1,32)
33,5
(3,8)
96,5
31,5
63
(2,48)
(1,24)
(1,32)
33,5
(3,8)
(1,18)
96,5
31,5
0
63
30
F
(1,18)
0
30
F
0
V1 V1
V2 V2 CRACKING
F MAX FLOW MAX PRESSURE WEIGHT
0 0 CODE TYPE
ports l/min [USgpm] bar [PSI]
PILOT RATIO PRESSURE
kg [lb]
7 7 bar [PSI]
(0,47)
(0,47)
(0,47)
(0,47)
(0,28) (0,28)
12
12
12
12
C1 C2 350
C1 C2 [5075]
1:5,5 4,5 [65]
40 FA5010 VBS2BT 3/8 BSPP 35 [9,2] 0,59 [1,3]
(1,57) 40
(1,57)
(0,65)
(1,83)
Steel body
(0,65) 0
46,5
16,5
(1,83)
0
46,5
16,5
mm [Inches]
94 95
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
VPD CHECK VALVES BSPP
DOUBLE ACTING PILOT CHECK VALVES
VPD pilot check valves are used to lock a double acting actuator in place in both directions, ensuring the load is
locked.
C1 C2
F A B C E L M N P ØD Q R S T
90 14 30 60 6,5 76 17 45 107
3/8 BSPP
10 50 30 60 [3,54] [0,55] [1,18] [2,36] [0,25] [3] [0,67] [1,77] [4,21]
[0,39] [1,97] [1,18] [2,36] 110 20 37 73 8,5 90 22 55 132
1/2 BSPP
[4,33] [0,78] [1,45] [2,87] [0,33] [3,54] [0,86] [2,16] [5,19]
Steel body
V1 V2
PERFORMANCES
PSI bar
C2 V2 PSI bar
V2 C2
C1 V1 V1 C1
240 16 240 16
120 8 120 8
F
0
R
T
L
60 4 60 4
V2 V1
E 0 0 0 0
0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
B 0 2,5 5 7,5 10 12,5 15 USgpm 0 2,5 5 7,5 10 12,5 15 USgpm
D
0 0
C2 C1
0
C
ORDERING CODE
0
P
N
M
CRACKING
F MAX FLOW MAX PRESSURE WEIGHT
CODE TYPE PILOT RATIO PRESSURE
ports l/min [USgpm ] bar [PSI] kg [lb]
bar [PSI]
mm [Inches]
FA5011 VPD2B 3/8 BSPP 35 [9,2] 1:7 1,2 [2,64]
350 [5075] 4,5 [65]
FA5013 VPD3B 1/2 BSPP 60 [15,83] 1:4 1,45 [3,20]
96 97
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
Max leakage: 0,25 cm3/min - 5 drops/min | Cracking pressure: 0,5 bar 7,25 PSI
VPF CHECK VALVES BSPP
DOUBLE ACTING PILOT CHECK VALVES, FLANGED VERSION
VPF pilot check valves are used to lock a double acting actuator in place in both directions, ensuring the load is
locked.
C1 C2
F C ØD E G H I L M N P Q R S T U
Steel body
V1 V2
PERFORMANCES
PSI bar
C2 V2 PSI bar
V2 C2
C1 V1 V1 C1
240 16 240 16
120 8 120 8
G
C
H
0
F 60 4 60 4
I
V2 V1 0 0 0 0
U 0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
C2 C1
D
0 0
ORDERING CODE
0
0
P
L
N
M
CRACKING
F MAX FLOW MAX PRESSURE WEIGHT
CODE TYPE PILOT RATIO PRESSURE
ports l/min [USgpm ] bar [PSI] kg [lb]
bar [PSI]
mm [Inches]
FA5012 VPF2B 3/8 BSPP 35 [9,2] 1:7 1,2 [2,64]
350 [5075] 4,5 [65]
FA5014 VPF3B 1/2 BSPP 60 [15,83] 1:4 1,45 [3,20]
98 99
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
Max leakage: 0,25 cm3/min - 5 drops/min | Cracking pressure: 0,5 bar 7,25 PSI
VSP MANUAL CHECK VALVES BSPP - RIGHT
SINGLE ACTING PILOT CHECK VALVES WITH MANUAL SHUT-OFF
VSP pilot check valves are mainly used to lock a single acting cylinder in position, they are made in left and right
hand versions.
120 5 120 8
C2 C1 90 4 3/8 90 6
3/8
60 3 60 4
30 2 30 2
0 0 0 0
0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
(1,67)
(3,31)
(0,69)
42,5
(1,38)
84
10
71
17,5
35
0
(0
0
9 )
V2 V1
,35
0 0
10
ORDERING CODE
3/8 BSPP
(0,39)
CRACKING
F MAX FLOW MAX PRESSURE WEIGHT
C2 C1 37 37 CODE TYPE
ports l/min [USgpm] bar [PSI]
PILOT RATIO PRESSURE
kg [lb]
(1,46) (1,46) bar [PSI]
50
(2,87)
(1,97) FA5015 VSP2BDX 3/8 BSPP 40 [10,52] 350 [5075] 1:4,20 4,5 [65] 1,08 [2,38]
72
Steel body
91
(3,58)
mm [Inches]
100 101
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
VSP MANUAL CHECK VALVES BSPP - LEFT
SINGLE ACTING PILOT CHECK VALVES WITH MANUAL SHUT-OFF
VSP pilot check valves are mainly used to lock a single acting cylinder in position, they are made in left and right
hand versions.
120 5 120 8
3/8
C1 C2 90 4 90 6
3/8
60 3 60 4
30 2 30 2
0 0 0 0
0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
(2,79)
(1,67)
(3,31)
42,5
(0,69)
84
(1,38)
10
71
9
)
17,5
35
,35
0
V1 V2
(0
ORDERING CODE
0 0
10
3/8 BSPP
(0,39)
CRACKING
F MAX FLOW MAX PRESSURE WEIGHT
CODE TYPE PILOT RATIO PRESSURE
ports l/min [USgpm] bar [PSI] kg [lb]
bar [PSI]
37 37 C1
(1,46) (1,46)
C2
FA5016 VSP2BSX 3/8 BSPP 40 [10,52] 350 [5075] 1:4,20 4,5 [65] 1,08 [2,38]
50
(2,87)
(1,97)
72
Steel body
91
(3,58)
mm [Inches]
102 103
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
VSS SHUTTLE VALVES BSPP
SHUTTLE VALVES
VSS shuttle valves are used when two pressure lines converge in the valve at the same time (the lower pressure line
locks).
3 F L A C D P M N
1/4 BSPP 57 [2,24] 52 [2,04] 12 [0,47] 29,5 [1,16] 9 [0,35] 24,5 [0,96] 43 [1,69]
1 2 3/8 BSPP 70 [2,76] 60 [2,36] 13,5 [0,53] 32 [1,26] 8 [0,31] 30 [1,18] 52 [2,05]
Steel body
PERFORMANCES
PSI bar
90 6
75 5
1/4 3/8
60 4
M
A
N
0
P
L
45 3
6,5 )
3
30 2
,26 40
(0
15 1
(1,57) 0 0
D 0 10 20 30 40 50 l/min
2
1 C
F
0 0
(1,18)
0
30
ORDERING CODE
mm [Inches]
F MAX FLOW MAX PRESSURE WEIGHT
CODE TYPE
ports l/min [USgpm] bar [PSI] kg [lb]
104 105
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
VSD SEQUENCE BSPP
SEQUENCE VALVES
VSD sequence valves are used with two cylinders; the end of the work of the first one coincides with the beginning of
the second one, at a given setting pressure.
F H C A
Steel body
PERFORMANCES
PSI bar
300 20 35
(4,21 Max)
21
107 Max
225 15
(0,24)
(2,52)
10
2,76)
150 10
64
70
6
(1,18)
30
75 5
0
0 0
H 0 10 20 30 40 50 l/min
(0 6,5
,26
) ORDERING CODE
A
0 0
10/70 16,5
FA6012 VSD2BC10
[145/1015] [239]
20/210 33
FA6013 VSD2BC21 3/8 BSPP 40 [10,6] 0,9 [1,98]
[290/3045] [479]
70/350 70
FA6014 VSD2BC35
[1015/5075] [1015]
M8
20/210 33
FA6016 VSD3BC21 1/2 BSPP 50 [13,2] 1 [2,21]
25 [290/3045] [479]
70/350 70
FA6017 VSD3BC35
[1015/5075] [1015]
106 107
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
VAA DOUBLE CROSS BSPP
DOUBLE CROSS RELIEF VALVES 50 L
VAA valves with steel manifold and two pressure relief valves, they control the pressure on both connection lines.
C1 V1 PSI bar
300 20 35
225 15 21
150 10 10
75 5
0 0
0 10 20 30 40 50 l/min
C2 V2
(3,15)
(1,18)
80
30
110,4
(4,35) ORDERING CODE
ports kg [lb]
,35
70/350 70
FA6041 VAA2BC35
C1 [1015/5075] [1015]
25
A C2 350 [5075]
10/70 12
7,5 FA6042 VAA3BC10
[145/1015] [174]
(0,29) M8
0 0 20/210 33
FA6043 VAA3BC21 1/2 BSPP 50 [13,2] 18,5 [0,73] 51,5 [2,03] 1,16 [2,55]
[290/3045] [479]
40,4
(1,18)
30
(1,59)
(1,97)
0
50
mm [Inches]
108 109
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
M20B RELIEF VALVES - 30 l/min BSPP
RELIEF VALVES 30 l/min
The purpose of the M20B pressure relief valve is to protect the hydraulic system from malfunctions or failures caused
by excessively high pressures in the circuit.
PSI bar
1 300 20
225 15
2 150 10
35
21
11
75 5
04
0 0
1
0 10 20 30 l/min
ORDERING CODE
INCREASE
F MAX FLOW MAX PRESSURE RANGE SPRING WEIGHT
CODE TYPE TO TURN
ports l/min [USgpm] bar [PSI] bar [PSI] kg [lb]
bar [PSI]
52 6,5 10/40 20
FA6018 M201BC04
(2,05) 47 )
(0,26
[145/580] [290]
(2,01) 20/110 40
FA6019 M201BC11
[290/1595] [580]
33
(1,3)
2 1/4 BSPP 20 [5,3]
30/210 70
FA6020 M201BC21
[435/3045 [1015]
13 FA6021 M201BC35
40/350 130
1 1 (0,51)
[580/5075] [1885]
F
(1,18)
15
30
(0,20)
30/210 70
(0,87)
(1,38)
(1,57)
FA6024 M202BC21
0
[435/3045 [1015]
40
35
22
5
40/350 130
FA6025 M202BC35
[580/5075] [1885]
mm [Inches]
Steel body
110 111
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
M40B RELIEF VALVES - 50 l/min BSPP
RELIEF VALVES 50 l/min
The purpose of the M40B pressure relief valve is to protect the hydraulic system from malfunctions or failures caused
by excessively high pressures in the circuit.
1 F L M N P H
Steel body
PERFORMANCES
PSI bar
300 20 35
225 15 21
0 0
0 10 20 30 40 50 l/min
H H
ORDERING CODE
N N 2 2
25
INCREASE
F MAX FLOW MAX PRESSURE RANGE SPRING WEIGHT
CODE TYPE TO TURN
ports l/min [USgpm] bar [PSI] bar [PSI] kg [lb]
M8 bar [PSI]
(0
(0
5, 1)
5, 1)
2
2
,2
,2
1 1 1 1 P P 10/70 16,5
F
5 5 FA6026 M402BC10
[145/1015] [239]
HANDKNOB CODE (0,20) (0,20)
20/210 33
62200012 0 0 0 0 FA6027 M402BC21 3/8 BSPP 40 [10,6]
[290/3045] [479]
0,6 [1,32]
70/350 70
(1,54)
(1,54)
0
FA6028 M402BC35
(0,20)
(0,20)
40
40
[1015/5075] [1015]
0
M0
L
M
5
350 [5075]
10/70 16,5
FA6029 M403BC10
[145/1015] [239]
20/210 33
mm [Inches] FA6030 M403BC21 1/2 BSPP 50 [13,2] 0,7 [1,54]
[290/3045] [479]
70/350 70
FA6031 M403BC35
[1015/5075] [1015]
112 113
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
M80B RELIEF VALVES - 80 l/min BSPP
RELIEF VALVES 80 l/min
The purpose of the M80 pressure relief valve is to protect the hydraulic system from malfunctions or failures caused
by excessively high pressures in the circuit.
PSI bar
1 300 20
225 15 35
2 150 10
25
10
75 5
0 0
1
0 20 40 60 80 l/min
0 5 10 15 20 USgpm
127 Max
127 Max
(5 Max)
(5 Max)
ORDERING CODE
INCREASE
F MAX FLOW MAX PRESSURE RANGE SPRING WEIGHT
CODE TYPE TO TURN
ports l/min [USgpm] bar [PSI] bar [PSI] kg [lb]
bar [PSI]
70 70 10/100 16,5
(2,75) (2,75) FA6032 M804BC10
[145/1450] [239]
50,5 50,5
(1,99) (1,99)
2 2 FA6033 M804BC25 3/4 BSPP 80 [21,1] 350 [5075]
20/250
[290/3625]
33
[479]
1 [2,2]
50/350 70
30
FA6034 M804BC35
[725/5075] [1015]
19,5 19,5
1 1 1 1 (0,76) (0,76) Steel body
F
M10
6,5 6,5 7 7
(0,25 (0,25 (0,27) (0,27)
) )
HANDKNOB CODE 0 0 0 0
62200010
(0,79)
(0,79)
(1,57)
(1,57)
0
(0,72)
(0,72)
(1,89)
(1,89)
(2,16)
(2,16)
0
40
40
20
20
18,5
18,5
48
48
55
55
mm [Inches]
114 115
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
VDF DIVIDER BSPP
FLOW DIVIDERS
Flow dividers/unifiers allow the inlet flow to be divided into two equal parts, while in the opposite direction they unify it.
P PSI bar
900 60
750 50 3-10
7-20
600 40
U1 U2 450 30
15-40
300 20
2-5
pe i ati s
150 10
Maximum division error: ±10% of the oil flow
0 0 in U1 or U2 and 120 bar [1750 PSI] pressure
0 10 20 30 40 50 l/min difference between U1 and U2.
0 2,5 5 7,5 10 12,5 USgpm (Division rate 50%÷50%)
ORDERING CODE
(2,84)
(0,28)
(0,32)
72
F
8
7
0
(3,15)
(1,34)
(1,97)
(0,71)
0
1/2 BSPP
80
50
35
34
18
116 117
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
MC3 CETOP 3
CETOP 3 SINGLE MANIFOLDS
The MC3 bases allow the assembly of a single CETOP 3 solenoid valve, they are supplied with a relief valve.
A-B-P-T M
P T B A ports ports
P T
121,5 Max
(4,78 Max) PERFORMANCES
(2,52)
(0,27)
64
PSI bar
0
(0,35)
(0,22)
5,5
21
9
225 15
80
74 (3,15)
T (2,91) M5 150 10
10
62 61,5
(2,44)
A
(2,42)
50 A 75 5
(1,97)
P T
P 0 0
M 0 10 20 30 40 50 l/min
26
B M B 21
0 2,5 5 7,5 10 12,5 USgpm
(1,02)
15 (0,83)
(0,59) 6
(0,27)
0 0 0 0
5,5
(0,22)
(0,74)
(2,02)
(2,76)
(0,79)
0
(1,46)
51,25
18,75
0
70
(1,06)
(1,95)
20
37
0
49,5
27
ORDERING CODE
HANDKNOB CODE
62200012 10/70 16,5
FA6035 MC3C10
[145/1015] [239]
50 [13,3] 210 [3045] 0,8 [1,76]
25 20/210 33
FA6036 MC3C21
mm [Inches] [290/3045] [479]
118 119
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
MC5 CETOP 5
CETOP 5 SINGLE MANIFOLDS
The MC5 bases allow the assembly of a single CETOP 5 solenoid valve, they are supplied with a relief valve.
A-B-P-T M
ports ports
P A B T
1/2 BSPP 1/4 BSPP
A B
Aluminium body
P T
152 Max
(5,98 Max)
PERFORMANCES
(0,22)
(3,33)
84,5
5,5
PSI bar
0
225 15
(0,22)
(0,22)
5,5
9
90
150 10
21
84,5 (3,54)
T (3,33)
74,5 10
(2,93) 75 5
M6
55
P (2,16) 0 0
42,5 T T 0 20 40 60 80 l/min
(1,67) 0 2,5 10 15 20 USgpm
24,5
(0,96)
B B A A
5,5 9
(0,22) P (0,35)
0 0 0 0
5,5
(0,22)
M
(3,54)
(2,83)
(0,71)
0
(1,95)
(1,24)
0
49,5
90
(1,77)
72
0
31,5
18
45
ORDERING CODE
HANDKNOB CODE
62200010 10/100 25
FA6037 MC5C10
[145/1450] [362]
80 [21,1] 210 [3045] 1,20 [2,64]
20/210 40
30 FA6038 MC5C21
mm [Inches] [290/3045] [580]
120 121
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
cartridge
VALVES
123
M20 SAE8/2 - 30 l/min - 350 bar
DIRECT ACTING RELIEF VALVES NON-GUIDED VERSION
The purpose of the M20 relief valves is to protect the hydraulic system from malfunctions or failures caused by
excessive pressure in the circuit.
Non-guided version, with mechanical stop under pressure.
PSI bar
375 25 35
21
300 20
11
225 15
1 2 150 10
04
75 5
0 0
0 5 10 15 20 25 30 l/min
HEX 22
ORDERING CODE
2
3/4-16UNF-2A MAX FLOW MAX PRESSURE RAGE SPRING
INCREASE TO TIGHTENING
WEIGHT
CODE TYPE CAVITY TURN TORQUE
l/min [USgpm] bar [PSI] bar [PSI] kg [lb]
bar [PSI] Nm [lbt ft]
1 FA7001 M20C04
10/40 20
12,7 [145/580] [290]
SAE8/2
(0,50) FA7002 M20C11
3/4-16UNF- 20/110 40
2B [290/1959] [580]
30 [8] 350 [5075] 30 [22] 0,11 [0,24]
See cavity 30/210 70
FA7003 M20C21
paragraph [435/3045] [1015]
p. 196
(0,98)
40/350 130
(1,04)
26,5
0
FA7004 M20C35
25
[580/5075] [1885]
mm [Inches]
124 125
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
M21 SAE8/2 - 30 l/min - 350 bar
DIRECT ACTING RELIEF VALVES GUIDED VERSION
The purpose of the M21 relief valves is to protect the hydraulic system from malfunctions or failures caused by exces-
sive pressure in the circuit.
Guided version, with mechanical stop under pressure.
PSI bar
375 25 35
21
300 20
11
225 15
1 2 150 10
04
75 5
0 0
0 5 10 15 20 25 30 l/min
(1,32)
(1,06)
33,5
25
27
ORDERING CODE
0
1 FA7005 M21C04
10/40 20
[145/580] [290]
12,7 SAE8/2
(0,50) FA7006 M21C11
3/4-16UNF- 20/110 40
2B [290/1959] [580]
30 [8] 350 [5075] 30 [22] 0,11 [0,24]
See cavity 30/210 70
FA7007 M21C21
paragraph [435/3045] [1015]
HEX 22 p. 196
40/350 130
FA7008 M21C35
[580/5075] [1885]
mm [Inches]
126 127
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
M30 M20 X 1,5 - 50 l/min - 350 bar
DIRECT ACTING RELIEF VALVES GUIDED VERSION
The purpose of the M30 pressure relief valves is to protect the hydraulic system from malfunctions or failures caused
by excessively high pressures in the circuit.
PSI bar
300 20
35
225 15
21
1 2 150 10
10
75 5
0 0
0 10 20 30 40 50 l/min
30
(2,44)
(1,42)
ORDERING CODE
62
36
M20x1.5
M20X1,5
INCREASE
10 MAX FLOW MAX PRESSURE RAGE SPRING TIGHTENING WEIGHT
CODE TYPE CAVITY TO TURN
(0,39) l/min [USgpm] bar [PSI] bar [PSI] TORQUE kg [lb]
bar [PSI]
1
M10
Nm [lbt ft]
18 10/70 16,5
FA7041 M30C10 FC002
2 (0,71)
M20X1,5
[145/1015] [239]
20/210 33
Hex.24 FA7042 M30C21 50 [13,3] 350 [5075] 30 [22] 0,16 [0,35]
See cavity [290/2045] [479]
paragraph
Capper washer p. 196 70/350 70
FA7043 M30C35
HANDKNOB CODE 12 x 18 x 1,5 [1015/5075] [1015]
code 61600013
62200010
mm [Inches]
128 129
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
M40 M20 X 1,5 - 50 l/min - 350 bar
DIRECT ACTING RELIEF VALVES GUIDED VERSION
The purpose of the M40 pressure relief valves is to protect the hydraulic system from malfunctions or failures caused
by excessively high pressures in the circuit.
PSI bar
300 20 TOOL
35
225 15
21 CHI07
1 2 150 10
10
75 5
0 0
0 10 20 30 40 50 l/min
25
HEX 22 CHI07 ORDERING CODE
2 M20x1,5
M14X1,5 M20X1,5
MAX FLOW MAX INCREASE TO
10 RAGE SPRING TIGHTENING TIGHTENING WEIGHT
CODE TYPE CAVITY l/min PRESSURE TURN
bar [PSI] TORQUE TORQUE kg [lb]
(0,39) [USgpm] bar [PSI] bar [PSI]
Nm [lbt ft] Nm [lbt ft]
M8
10/70 16,5
M14x1,5 FA7009 M40C10 FC003 [145/1015] [239]
1 M20X1,5
20/210 33
FA7010 M40C21 50 [13,3] 350 [5075] 10 [7] 40 [30] 0,13 [0,29]
See cavity [290/2045] [479]
paragraph
p. 197 70/350 70
(1,14)
(1,89)
(1,16)
HANDKNOB CODE
29,5
FA7011 M40C35
0
29
48
[1015/5075] [1015]
62200012
mm [Inches]
130 131
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
M42 SAE 10/2 - 50 l/min - 350 bar
DIRECT ACTING RELIEF VALVES GUIDED VERSION
The purpose of the M42 pressure relief valves is to protect the hydraulic system from malfunctions or failures caused
by excessively high pressures in the circuit.
PSI bar
300 20
225 15 35
1 2 150 10 21
10
75 5
0 0
0 10 20 30 40 50 l/min
30
ORDERING CODE
HEX 25
1
15,85 SAE10/2 10/70 16,5
FA7012 M42C10
7/8-14UN- [145/1015] [239]
(0,62) F-2B
20/210 33
FA7013 M42C21 50 [13,5] 350 [5075] 40 [30] 0,18 [0,37]
[290/2045] [479]
See cavity
(1,46)
(1,26)
(1,73)
paragraph
0
37,2
70/350 70
44
32
mm [Inches]
132 133
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
M80 M24 X 1,5 - 80 l/min - 350 bar
DIRECT ACTING RELIEF VALVES GUIDED VERSION
The purpose of the M80 pressure relief valves is to protect the hydraulic system from malfunctions or failures caused
by excessively high pressures in the circuit.
PSI bar
300 20
225 15 35
1 2 150 10 21
10
75 5
0 0
0 20 40 60 80 l/min
0 5 10 15 20 USgpm
30
ORDERING CODE
HEX 30
2 M24x1,5
MAX INCREASE TIGHTENING
MAX FLOW RAGE SPRING WEIGHT
12 CODE TYPE CAVITY
l/min [USgpm]
PRESSURE
bar [PSI]
TO TURN TORQUE
kg [lb]
bar [PSI] bar [PSI] Nm [lbt ft]
(0,47)
M10
10/100 25
FA7015 M80C10
21 FC005 [145/1450] [362]
M24X1,5
1 (0,83)
FA7016 M80C25 80 [21,1] 350 [5075]
20/250 40
60 [44] 0,25 [0,55]
See cavity [290/3625] [580]
paragraph
50/350 90
(2,03)
p. 203
0
(1,76)
FA7017 M80C35
44,7
51,5
[725/5075] [1305]
HANDKNOB CODE
62200010
mm [Inches]
134 135
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
UC2 SAE8/2 - 35 l/min - 350 bar
CHECK VALVES POPPET TYPE
The UC2 cartridge check valve allows free oil flow in one direction and blocks it in the opposite direction.
PSI bar
120 8
2 1 90 6
60 4
30 2
0 0
0 10 20 30 40 l/min
ORDERING CODE
HEX 22
TIGHTENING
2 CODE TYPE CAVITY
MAX FLOW
l/min [USgpm]
MAX PRESSURE
bar [PSI]
SPRING
bar [PSI]
TORQUE
Nm [lbt ft]
WEIGHT
kg [lb]
3/4-16UNF-2A
FA7018 UC205 0,5 [7,3]
SAE8/2
1 FA7019 UC230
3/4-16UNF-2B
3 [43,5]
12,7 See cavity
35 [9,2] 350 [5075] 30 [22] 0,08 [0,17]
paragraph
(0,50) FA7020 UC245 p. 196 4,5 [65]
Poppet type
FA7021 UC260 6 [87]
(0,69)
(1,04)
0
26,5
17,5
SAE8/2
FA7044 US205 3/4-16UNF-2B 35 [9,2] 350 [5075] 0,5 [7,3] 30 [22] 0,08 [0,17]
Ball type
mm [Inches]
136 137
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
UC3 SAE10/2 - 80 l/min - 350 bar
CHECK VALVES POPPET TYPE
The UC3 cartridge check valve allows free oil flow in one direction and blocks it in the opposite direction.
PSI bar
120 8
2 1 90 6
60 4
30 2
0 0
0 20 40 60 80 l/min
0 5 10 15 20 USgpm
7/8-14UNF-2A
HEX 27
ORDERING CODE
2
0 TIGHTENING
SPRING MAX FLOW MAX PRESSURE WEIGHT
CODE TYPE CAVITY TORQUE
bar [PSI] l/min [USgpm] bar [PSI] kg [lb]
1 Nm [lbt ft]
(1,30)
0
33
22
mm [Inches]
138 139
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
CU2 SAE 8/2 - 40 l/min - 350 bar
UNIDIRECTIONAL FLOW CONTROL VALVES
The one-way flow control valves allow regulation in one direction and free passage in the opposite direction.
PSI bar
300 20
225 15
2 1
1 2 150 10
1 2
75 5
0 0
0 10 20 30 40 l/min
CU2V
ORDERING CODE
TIGHTENING
MAX FLOW MAX PRESSURE WEIGHT
CODE TYPE CAVITY TORQUE
CONTROL
SAE8/2
FA7022 CU2C 3/4-16UNF-2B
HEX 24 40 [10,6] 350 [5075] 30 [22] 0,13 [0,30]
See cavity
FA7023 CU2V paragraph
2 p. 196
3/4-16UNF-2A
1
12,7
(0,50)
(1,04)
(1,36)
34,5
26,5
0
mm [Inches]
140 141
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
CB2 SAE8/2 - 40 l/min - 350 bar
BIDIRECTIONAL FLOW CONTROL VALVES
Bidirectional flow control valves, allow flow regulation in both directions.
PSI bar 1 2
150 10
2 1 120 8
90 6
60 4
30 2
0 0
0 10 20 30 40 l/min
CB2V
ORDERING CODE
TIGHTENING
MAX FLOW MAX PRESSURE WEIGHT
CODE TYPE CAVITY TORQUE
l/min [USgpm] bar [PSI] kg [lb]
Nm [lbt ft]
SAE8/2
HEX 22 FA7024 CB2C 3/4-16UNF-2B 0,1 [0,22]
2 See cavity
40 [10,6] 350 [5075] 30 [22]
1
12,7
(0,50)
mm [Inches]
(0,73)
(1,04)
0
18,5
26,5
142 143
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
VM2 SAE 8/2 - 30 l/min - 350 bar
EMERGENCY VALVES
The bidirectional valves, with direct action VM2 normally closed 2 ways 2 positions, allow manual intervention, the
opening is obtained by manually pushing the rear button, removing the hand automatically the valve closes.
2
PSI bar
300 20
1 2
225 15
150 10
2 1
75 5
0 0
0 10 20 30 l/min
HEX 22
ORDERING CODE
2
0
TIGHTENING
1 CODE TYPE CAVITY
MAX FLOW
l/min [USgpm]
MAX PRESSURE
bar [PSI]
TORQUE
WEIGHT
kg [lb]
Nm [lbt ft]
12,7
(0,50)
SAE8/2
3/4-16UNF-2B
FA7026 VM2 30 [7,9] 350 [5075] 30 [22] 0,12 [0,26]
(1,48)
(1,04)
See cavity
0
26,5
37
paragraph
p. 196
mm [Inches]
144 145
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
PM2 SAE 8/2 - 2 cm3 - 200 bar
HAND PUMPS
PM2 hand pumps are made in SAE8/2 cavities, often mounted as emergency on mini power packs or mounted on
integrated blocks.
660 300
550 250
440 200
330 150
220 100
110 50
0 0
0 50 100 150 200 bar
ORDERING CODE
TIGHTENING
MAX PRESSURE DISPLACEMENT WEIGHT
CODE TYPE CAVITY TORQUE
bar [PSI] cm3 [in3] kg [lb]
Nm [lbt ft]
SAE8/2
3/4-16UNF-2B
FA7027 PM2 200 [2900] 2 [0,12] 30 [22] 0,46 [1,01]
See cavity
paragraph
p. 196
M5 x 45
2
3/4-16UNF-2A
1
(1,00)
25,5
12,7
(0,50)
25,5
(2,28)
(1,06)
(1,00)
0
58
27
mm [Inches]
146 147
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
DC2 SAE 8/2 - 12 l/min - 250 bar
FIXED FLOW CONTROL VALVES - PRESSURE COMPENSATED
The DC2 compensated fixed flow control valves are used to keep the descent speed of a load constant, regardless of
the operating pressure and the value of the load.
1 1
FA7046 DC201
[0,26] [0,04]
2 1,2
1 2
FA7047 DC202
[0,53] [0,05]
3 1,5
FA7048 DC203
[0,79] [0,06]
4 1,7
FA7049 DC204
[1,06] [0,07]
5 1,9
FA7050 DC205
[1,32] [0,07]
SAE8/2
3/4-16UNF-2B 6 2,1
FA7051 DC206
[1,58] [0,08] 250 30 0,06
See cavity 7 2,3 [3625] [22] [0,13]
FA7052 DC207 paragraph [1,85] [0,09]
p. 196
8 2,4
FA7053 DC208
[2,11] [0,09]
9 2,7
Hex.22 FA7054 DC209
[2,38] [0,11]
ØH 10 2,8
FA7055 DC210
3/4-16UNF-2A [2,64] [0,11]
11 3,1
FA7056 DC211
[2,90] [0,12]
FLOW
1 CONTROL 12 3,3
FA7057 DC212
[3,17] [0,13]
12,7
(0,50)
2
(0,29)
(1,08)
27,5
7,5
mm [Inches]
148 149
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
DR2 SAE 8/2 - 18 l/min - 350 bar
ADJUSTABLE FLOW CONTROL VALVES - PRESSURE COMPENSATED
Adjustable compensated flow control valve, used to keep the speed constant, regardless of the working pressure.
USgpm l/min
5 20
4 16
3 12
1 2 2 8
1 4
0 0
0 50 100 150 200 250 300 350 bar
FLOW
78,5 Max
CONTROL
(1,04)
26,5
HEX 22
0
2
ORDERING CODE
3/4-16UNF-2A
1
H
MAX FLOW
TIGHTENING
12,7 CONTROLLED FLOW AT 100 ØH MAX PRESSURE WEIGHT
CODE TYPE CAVITY TORQUE
(0,5) bar ± 10% mm [Inches] bar [PSI] kg [lb]
Nm [lbt ft]
l/min [USgpm]
mm [Inches]
150 151
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
VP2 SAE 8/2 - 30 l/min - 350 bar
PNEUMATIC OPERATED VALVES
2-way/2-position pneumatic control valve, made in SAE8/2 cavity with pilot pressure 4/15 bar.
PSI bar 1 2
2 150 10
3 75 5
1 0 0
0 10 20 30 l/min
HEX 22
ORDERING CODE
2
3/4-16UNF-2A
1/4 BSPP
TIGHTENING
3 1 CODE TYPE CAVITY
MAX FLOW MAX PRESSURE
TORQUE
PILOT PRESSURE WEIGHT
l/min [USgpm] bar [PSI] bar [PSI] kg [lb]
12,7 Nm [lbt ft]
(0,50)
SAE8/2
34 3/4-16UN-
F-2B
(1,34)
FA7035 VP2 30 [7,9] 350 [5075] 30 [22] 4/15 [58/218] 0,16 [0,35]
(2,07)
(1,06)
See cavity
0
52,5
27
paragraph
p. 196
mm [Inches]
152 153
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min at 80% of the calibration pressure
VBC M22 X, 1,5 - 50 l/min - 350 bar
SINGLE ACTING PILOT CHECK VALVES
VBC check valves are used to lock a single acting actuator in position, ensuring the blocking of the load.
3 2 450 30 450 30
1 300 20 300 20
150 10 150 10
0 0 0 0
0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
HEX 27
3 2 19 ORDERING CODE
(0,75)
CRACKING
1 CODE TYPE CAVITY
MAX FLOW
l/min [USgpm]
MAX PRESSURE
bar [PSI]
PRESSURE
STANDARD
TIGHTENING
TORQUE PILOT RATIO
WEIGHT
kg [lb]
Nm [lbt ft]
bar [PSI]
18
FC004
(0,71)
M22X1,5
M22x1,5 FA7036 VBC2250 50 [13,3] 350 [5075] 5 [72] 40 [30] 1:2,5 0,12 [0,26]
See cavity
paragraph
(0,49)
(1,85)
0
p. 199
28,5
(1,12)
12,4
47
mm [Inches]
154 155
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
VDF3 SAE10/4 - 40 l/min - 350 bar
FLOW DIVIDERS
The flow divider/combiner valves guarantee the division of the flow into two equal parts or the reunification in the
opposite direction.
PSI bar
P 900 60
750 50 3-10
7-20
600 40
450 30
U1 U2 300 20 2-5
15-40
pe i ati s
150 10 Maximum division error: ±10% of the oil flow
0 0
in U1 or U2 and 120 bar [1750 PSI] pressure
0 10 20 30 40 50 l/min difference between U1 and U2.
0 2,5 5 7,5 10 12,5 USgpm
(Division rate 50%÷50%)
ORDERING CODE
HEX 24
(0,62)
(0,75)
(0,69)
SAE10/4
FA7038 VDF3S2 7/8-14UNF-2B 3-10 [0,8-2,6]
U2 U1 40 [10,6] 350 [5075] 35 [26] 0,12 [0,26]
See cavity
FA7039 VDF3S3 paragraph 7-20 [1,8-5,2]
(1,18) p. 198
(2,49)
mm [Inches]
(2,79)
156 157
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
solenoid
VALVES
159
E2F28 SAE8/2 - 22 l/min - 250 bar
SOLENOID VALVE 2 WAYS 2 POSITIONS, POPPET DIRECT OPERATED
PSI bar 1 2
15
2 200
12
150
9
100
6
1
50 3
ELECTRIC mm [Inches]
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
(1,58)
(1,04)
-20 C° + 40 C°
26,5
40,2
91,5
Push Emergency
3/4-16UNF-2A
1
12,7
(0,50)
2
ORDERING CODE
O-Ring 14 x 1,78 HEX 24
CH 24
MAX TIGHTENING
MAX FLOW TIGHTENING WEIGHT
CODE TYPE VERSIONS CAVITY PRESSURE TORQUE NUT
l/min [USgpm] TORQUE kg [lb]
bar [PSI] Nm [lbt ft]
Nm [lbt ft]
mm [Inches]
SAE8/2
3/4-16UN-
F-2B
Normally closed
FA8001 E2F28E 22 [5,8] 250 [3625] 30 [22] 2 [1,5] 0,12 [0,26]
+ emergency
See cavity
paragraph
p. 196
160 161
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
E2S20 SAE8/2 - 40 l/min - 350 bar
SOLENOID VALVE 2 WAYS 2 POSITIONS, POPPET PILOT OPERATED
2 1
22 22 22 PSI bar
10
140
8 120
100
6
80
11 11 11 4 60
40
2
20
E2S20C E2S20E
0 0 Tests carried out with solenoids at their
Normally closed Normally closed with 0 2 4 6 8 10 l/min
working temperature, with a supply
emergency 0 10 20 30 40 USgpm voltage 10% below the nominal value.
2 2 2
1 1 1
E2S20A
ELECTRIC mm [Inches]
Normally open
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
HEX 24
NUT Emergency
(0,63)
(0,5)
12,7
13
10,50
(0,413) ORDERING CODE
2
(0,394)
CH 24
MAX TIGHTENING
10
162 163
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
E2L20 SAE8/2 - 30 l/min - 300 bar
SOLENOID VALVE 2 WAYS 2 POSITIONS, POPPET PILOT OPERATED
E2L20C/E2L20E E2L20A
2 2 2 2 2PSI bar
2 PSI bar
10 10
140 140
8 120 2 1 8 120
100 100 2 1
6 6
80 80
4 60 4 60
1 1 1 1 1 40
1 40
2 2
20 20
E2L20C E2L20E
0 0 0 0
Normally closed Normally closed with 0 2 4 6 8 10 l/min 0 2 4 6 8 10 l/min
2 2 2 Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.
1 1 1
E2L20A
Normally open ELECTRIC mm [Inches]
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
HEX 24
NUT Emergency
(0,63)
(0,5)
12,7
13
10,50
(0,413) ORDERING CODE
2
(0,394)
CH 24
MAX TIGHTENING
10
164 165
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
E2S22 SAE8/2 - 40 l/min - 300 bar
SOLENOID VALVE 2 WAYS 2 POSITIONS, POPPET PILOT OPERATED
E2S22C/E2S22E E2S22A
22 22 22 PSI bar PSI bar
10
140 1 2 10
140
1 2
120 2 1 120
8 8
2 1
100 100
6 6
80 80
1 1 1 1 1 1 4 60 4 60
40 40
2 2
20 20
E2S22C E2S22E
0 0 0 0
Normally closed Normally closed with 0 2 4 6 8 10 l/min 0 2 4 6 8 10 l/min
2 2 2
Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.
1 1 1
E2S22A
ELECTRIC mm [Inches]
Normally open
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
HEX 24
Emergency
(0,63)
NUT
(0,5)
12,7
13
10,50
(0,413) ORDERING CODE
2
(0,394)
CH 24
MAX TIGHTENING
10
166 167
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
E2S24 SAE8/2 - 40 l/min - 350 bar
SOLENOID VALVE 2 WAYS 2 POSITIONS, POPPET PILOT OPERATED
E2S24C/E2S24E E2S24A
1 1 1 PSI bar PSI bar
10 10
140 140
120 1 2 120
8 8
1 2
100 100
6 6
80 80
2 2 2 4 60 4 60
40 40
2 2
20 20
E2S24C E2S24E
0 0 0 0
Normally closed Normally closed with 0 2 4 6 8 10 l/min 0 2 4 6 8 10 l/min
1 1 1
Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.
2 2 2
E2S24A
ELECTRIC mm [Inches]
Normally open
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
HEX 24
Emergency
(0,63)
NUT
(0,5)
12,7
13
10,50
(0,413) ORDERING CODE
2
(0,394)
CH 24
MAX TIGHTENING
10
168 169
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
E2S26 SAE8/2 - 40 l/min - 350 bar
SOLENOID VALVE 2 WAYS 2 POSITIONS, POPPET PILOT OPERATED
E2S26C/E2S26E E2S26A
1 1 1 1 1 1 PSI bar PSI bar
10 10
140 1 2 140
8 120
2 1 8 120
1 2
6
100
6
100 2 1
80 80
4 60 4 60
2 2 2 2 2 2
40 40
2 2
20 20
E2S26C E2S26E
0 0 0 0
Normally closed Normally closed with 0 2 4 6 8 10 l/min 0 2 4 6 8 10 l/min
1 1 1
Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.
2 2 2
E2S26A
ELECTRIC mm [Inches]
Normally open
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
HEX 24
Emergency
(0,63)
NUT
(0,5)
12,7
13
10,50
(0,413) ORDERING CODE
2
(0,394)
CH 24
10
MAX TIGHTENING
1
170 171
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
E2S28 SAE8/2 - 40 l/min - 350 bar
SOLENOID VALVE 2 WAYS 2 POSITIONS, POPPET DIRECT OPERATED
8 120 2 1 8 120 1 2
100 100 2 1
6 6
80 80
1 1 1 1 1 14 60
1 1 4 60
40 40
2 2
20 20
E2S28C E2S28E
0 0 0 0
Normally closed Normally closed with 0 2 4 6 8 10 l/min 0 2 4 6 8 10 l/min
2 2 2 2
Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.
1 1 1 1
E2S28A
ELECTRIC mm [Inches]
Normally open
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
HEX 24
Emergency
(0,63)
NUT
(0,5)
12,7
13
10,50
(0,413) ORDERING CODE
2
(0,394)
CH 24
MAX TIGHTENING
10
172 173
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
E6S30 SAE8/3 - 12 l/min - 210 bar
SOLENOID VALVE 3 WAYS 2 POSITIONS, DIRECT ACTING SPOOL TYPE
1 3 1 3 1 3 1 3 PSI bar
15
200
3 2
10 150
2 1
100
2 2 2 2 5
50
E6S30A E6S30E
0 0 Tests carried out with solenoids at their
Standard With emergency 0 1 2 3 4 l/min
working temperature, with a supply
0 3 6 9 12 15 USgpm voltage 10% below the nominal value.
ELECTRIC mm [Inches]
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
(0,62)
(0,56)
Emergency
15,8
14,2
NUT 10,50
(0,413)
(0,394)
ORDERING CODE
10
1
3 2
CH 24
MAX TIGHTENING
MAX FLOW TIGHTENING WEIGHT
CODE TYPE VERSIONS CAVITY PRESSURE TORQUE NUT
l/min [USgpm] TORQUE kg [lb]
bar [PSI] Nm [lbt ft]
Nm [lbt ft]
O-RING 14x1,78
SAE8/3
61,7 39,5 FA8020 E6S30A Standard 3/4-16UN-
F-2B
(2,43) (1,56) 12 [3,2] 210 [3045] 30 [22] 2 [1,5] 0,15 [0,33]
See cavity
FA8021 E6S30E With emergency paragraph
p. 197
174 175
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
Max leakage: 60 cm3/min
E6S31 SAE8/3 - 12 l/min - 210 bar
SOLENOID VALVE 3 WAYS 2 POSITIONS, DIRECT ACTING SPOOL TYPE
3 1 3 1 3 1 3 1 PSI bar
15
200
3 2
10 150
2 1
100
2 2 2 2 5
50
E6S31A E6S31E
0 0 Tests carried out with solenoids at their
Standard With emergency 0 1 2 3 4 l/min
working temperature, with a supply
0 3 6 9 12 15 USgpm voltage 10% below the nominal value.
ELECTRIC mm [Inches]
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
3/4-16 UNF-2A
14,2
15,8
NUT
Emergency
(0,63)
13
10,50
(0,413)
1
ORDERING CODE
(1,024)
26
3 2
CH 24
MAX TIGHTENING
MAX FLOW TIGHTENING WEIGHT
O-RING 14x1,78 CODE TYPE VERSIONS CAVITY PRESSURE TORQUE NUT
l/min [USgpm] TORQUE kg [lb]
bar [PSI] Nm [lbt ft]
Nm [lbt ft]
39,5
SAE8/3
(1,56) Rotating the knob clockwise the valve FA8022 E6S31A Standard 3/4-16UN-
F-2B
switches position.
12 [3,2] 210 [3045] 30 [22] 2 [1,5] 0,15 [0,33]
See cavity
FA8023 E6S31E With emergency paragraph
p. 197
176 177
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
Max leakage: 60 cm3/min
E3S20 SAE10/2 - 70 l/min - 350 bar
SOLENOID VALVE 2 WAYS 2 POSITIONS, POPPET PILOT OPERATED
2 2 2 2 2 2 bar
PSI E3S20C/E3S20E PSI bar E3S20A
15 15
200 200
2 1
12 12
2 1
150 150
9 9
100 100
6 6
1 1 1 1 1 1
50 50
3 3
E3S20C E3S20E
0 0 0 0
Normally closed Normally closed with 0 6 12 18 l/min 0 6 12 18 l/min
2 2 2
Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.
1 1 1
E3S20A ELECTRIC mm [Inches]
Normally open
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
HEX 27
Emergency
(0,62)
NUT
15,8
10,50
(0,63)
13
(0,394)
CH 24
10
MAX TIGHTENING
1
178 179
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
E3S22 SAE10/2 - 70 l/min - 350 bar
SOLENOID VALVE 2 WAYS 2 POSITIONS, POPPET PILOT OPERATED
2 2 2 2 2 PSI
2bar E3S22C/E3S22E PSI bar E3S22A
15 15
200 1 2 200 1 2
12 2 1 12
2 1
150 150
9 9
100 100
6 6
1 1 1 1 1 1
50 50
3 3
E3S22C E3S22E
0 0 0 0
Normally closed Normally closed with 0 6 12 18 l/min 0 6 12 18 l/min
2 2 2
Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.
1 1 1
E3S22A ELECTRIC mm [Inches]
Normally open
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
HEX 27
Emergency
(0,62)
NUT
15,8
10,50
(0,63)
(0,394)
CH 24
MAX TIGHTENING
10
180 181
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
E3S24 SAE10/2 - 70 l/min - 350 bar
SOLENOID VALVE 2 WAYS 2 POSITIONS, POPPET PILOT OPERATED
1 1 1 1 1 PSI
1bar E3S24C/E3S24E PSI bar E3S24A
15 15
200 1 2 200
12 12
1 2
150 150
9 9
100 100
6 6
2 2 2 2 2 2
50 50
3 3
E3S24C E3S24E
0 0 0 0
Normally closed Normally closed with 0 6 12 18 l/min 0 6 12 18 l/min
1 1 1
Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.
2 2 2
E3S24A
ELECTRIC mm [Inches]
Normally open
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
HEX 27 Emergency
10,50
(0,62)
NUT
15,8
(0,394)
CH 24
MAX TIGHTENING
10
182 183
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
E3S26 SAE10/2 - 70 l/min - 350 bar
SOLENOID VALVE 2 WAYS 2 POSITIONS, POPPET PILOT OPERATED
E3S26C/E3S26E E3S26A
1 1 1 1 1 PSI
1bar PSI bar
18 15
200
1 2
15
250
1 2 12 2 1
12 200 2 1 150
9
9 150
100
6
2 2 2 2 2 6 2100
50
3
3 50
E3S26C E3S26E
0 0 0 0
Normally closed Normally closed with 0 6 12 18 l/min 0 6 12 18 l/min
1 1 1
Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.
2 2 2
E3S26A
ELECTRIC mm [Inches]
Normally open
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
HEX 27
Emergency
(0,62)
NUT
15,8
10,50
(0,63)
(0,394)
CH 24
MAX TIGHTENING
10
184 185
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
E3S28 SAE10/2 - 70 l/min - 350 bar
SOLENOID VALVE 2 WAYS 2 POSITIONS, POPPET PILOT OPERATED
E3S28C/E3S28E E3S28A
2 2 2 2 2 2
PSI bar PSI bar
15 1 2 15
200 200 1 2
2 1
12 12 2 1
150 150
9 9
100 100
1 1 1 1 1 6
1 6
50 50
3 3
E3S28C E3S28E
0 0 0 0
Normally closed Normally closed with 0 6 12 18 l/min 0 6 12 18 l/min
2 2 2 Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.
1 1 1
E3S28A
ELECTRIC mm [Inches]
Normally open
TYPE VOLTAGE INSULATION INDEX NOMINAL VOLTAGE POWER AT 20C° POWER AT 20C° COIL CODE
HEX 27
Emergency
(0,63)
NUT
(0,62)
10,50
15,8
13
(0,394)
CH 24
10
MAX TIGHTENING
MAX FLOW TIGHTENING WEIGHT
CODE TYPE VERSIONS CAVITY PRESSURE TORQUE NUT
1
186 187
Mineral oil: DIN 51524 ISO 6743/4 | Oil viscosity: 15 to 250 cSt 15-250 mm2/s | Oil temperature: -4°F + 176°F Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
-20°C +80°C | Ambient temperature: -4°F + 122°F -20°C +50°C | Max contamination index with filter: 5 to 250
Fluid-app Srl reserves the right to modify its products without notice.
cSt 15-250 mm2/s | It is necessary a filter use to protect the valve (advised filtration 15 μm) | Max leakage: Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0,25 cm3/min - 5 drops/min
C22 COILS
22W COILS
48 ORDERING CODE
(1,89)
44,5
TIGHTENING
(1,75) CODE TYPE VOLTAGE RESISTANCE
MATCHING CON- ABSORBED
TORQUE
WEIGHT
13,2 NECTOR POWER
Nm lbt ft
kg lbt
(0,52
)
C2212 C2212 12Vdc 6,5 Ω
CNS
22 W 2 [1,5] 0,21 [0,46]
[DIN 43650]
C2224 C2224 24Vdc 26,5 Ω
0
(1,42)
0
(1,52)
36
38,5
mm [Inches]
188 189
Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
Fluid-app Srl reserves the right to modify its products without notice.
Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
CNS CONNECTORS
ORDERING CODE
MAX
NOMINAL MAX OPERATING CONTACT CONTACT GAND SIZE
CODE TYPE CONDUCTORS
CURRENT CURRENT RESISTANCE HOLDER OPTIONS
CROSS-SECTION
42
(1,65)
0
(1,06)
0
(1,14)
27
29
mm [Inches]
190 191
Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
Fluid-app Srl reserves the right to modify its products without notice.
Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
MANIFOLD SAE8/2
3/4-16UNF-2A
50
(1,97) ORDERING CODE
2 34,5
(1,36) MAX WORKING
WEIGHT
CODE F CAVITY PRESSURE
kg lb
bar PSI
19,5
7 (0,79) SAE8/2
) 31100042 1/4 BSPP 0,48 [1,06]
(0,28
3/4-16UNF-2B
350 [5076]
See cavity
31100043 3/8 BSPP paragraph 0,45 [1,99]
p. 196
0
1 Steel body
F
(1,97)
(1,73)
(0,24)
0
50
44
3/4-16UNF-2A
50 30
(1,97) (1,18)
2 34,5 15
(1,36) (0,59)
19,5
7 (0,79) 0
)
(0,28
(1,18)
0
30
0
1
F
(1,97)
(1,73)
(0,24)
0
50
44
mm [Inches]
30
(1,18)
UPDATE. March 2023 (v.05)
15
192 193
Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
(0,59)
Fluid-app Srl reserves the right to modify its products without notice.
Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
0
(1,18)
0
30
CAVITY
195
CAVITY SAE/2 SAE/3
A
B
0.025 A
A
0.05 B
B F
0.025 A
0.025 A
±1°
15°
0.05 B
0.05 B
1.6
F
C
1.6
1° 0.025 A
1 5° +- 0.025 A
0.1 B
(0,02)
0.05 B
A
0,5
0.05 B 1.6
C
0.1 B 0.025 A
A
0,5
E
0.05 B 1.6
45° ±5°
5
H
,2
R0
N
°
E
5° +5
L
-
4
5
,2
G
R0
M
N
30°
R
3
V
H
T
P
1.6
30° 2 G
1
0.025 A 30°
0.05 B
M
2
1.6
B
L
0.025 A P
0.025 A
B
1.6
1 D
ØA E ØG ØP
CAVITY F ØB ØC ØD
+ 0,5 + 0,3 + 0,05 H L ØM N + 0,05 R T V
ØA E H L P CODE ports ± 0,05 ± 0,05 MAX
CAVITY F ØB ØC ØD 0 0 0 0
+ 0,5 + 0,3 G + 0,1 + 0,05 ØM N + 0,5
CODE ports ± 0,05 ± 0,05 MAX
0 0 0 0 0
27 20,66 17,42 12,5 2,5 15,9 12,5 19,1 5,5 14,3 14,3 28,6 43,3 33,3
SAE08/3 3/4-16UNF-2B
27 20,66 17,42 12 2,5 13 18,2 12,7 8 14 29,5 [1,06] [0,81] [0,69] [0,49] [0,1] [0,63] [0,49] [0,75] [0,22] [0,56] [0,56] [1,13] [1,7] [1,31]
SAE08/2 3/4-16UNF-2B
[1,06] [0,81] [0,69] [0,47] [0,1] [0,51] [0,72] [0,5] [0,31] [0,55] [1,16]
30 24 20,62 14 2,8 17,5 16 23,1 6,5 18,3 15,9 34 47,6 39,6
30 24 20,62 15 2,8 16 24 15,9 11 18 33,5 SAE10/3 7/8-14UNF-2B
SAE10/2 7/8-14UNF-2B [1,18] [0,94] [0,81] [0,55] [0,11] [0,69] [63] [0,91] [0,26] [0,72] [0,63] [1,34] [1,87] [1,56]
[1,18] [0,94] [0,81] [0,59] [0,11] [0,63] [0,94] [0,6] [0,43] [0,71] [1,32]
38 29,23 24,73 19 3,5 20 35 22,2 18 24,5 47 38 29,23 24,73 19 3,5 23,8 19 36,6 16 24,5 22,2 53 75,4 63,5
SAE12/2 1-1/16-12UN-2B SAE12/3 1-1/16-12UN-2B
[1,50] [1,15] [0,97] [0,75] [0,14] [0,79] [1,38] [0,87] [0,71] [0,96] [1,85] [1,50] [1,15] [0,97] [0,75] [0,14] [0,94] [0,75] [1,44] [0,63] [0,96] [0,87] [2,09] [2,97] [2,5]
196 197
Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
Fluid-app Srl reserves the right to modify its products without notice.
Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
CAVITY SAE10/4 FC001 (VBC1850 VALVE)
+0,5
30 0
+0,1 23
23,9 0 (0,91)
0.025 A +0,1
±1° 19,8 0 15°
15° Ø0.05 B 7/8-14UNF-2B (0,78)
0.1 B 0.025 A M18x1,5
+0,1 Ø0.05 A
1.6
20,5 0 Ø0.05 B +0,05
0.05 B 15 0
1.6
0.025 A
(0,04)
A ,25
3,3 ±0,1
(0,59)
(0,13)
0,5
1.6 R0 ,2 B
1.6
Ø0.05 B R0 1.6
1
+0,3
(0,47)
0
45
(0,51)
12
°±
2,6
13
16
(0,71)
23,5 -0,2
5° °
18
45
18
0
3
(1,06)
27
(1,30)
34
39,5 ±0,1
33
0,26 Max)
6,5 Max
(1,65)
(1,69)
4
42
43
8
20
50
55,5 ±0,1
°
2
°
1.6
30
+0,05
+0,5
19,05 0
0
(
0.025 A
64,5
0,26 Max)
6,5 Max
Ø0.05 B
3 °
8
20
°
1
30
1.6
+0,05
17,5
(
0
0.025 A
0,26 Max)
Ø0.05 B
6,5 Max
2
8
30°
+0,05 B
15,9
1.6
0
6,5 Min
0.025 A 1
(
( 0,26 Min)
13 Max
1
1.6
( 0,51 Max)
A 14
+0,05
0
15
mm [Inches] mm [Inches]
198 199
Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
Fluid-app Srl reserves the right to modify its products without notice.
Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
CAVITY FC002 (M30 VALVE) FC003 (M40 VALVE)
+0,021
21 H7 0
(0,83)
M20x1,5
26
18,5 (1,02)
(0,28)
(0 0,5
(0,73)
+0,2
21,8 ±0,05
2)
7 0
15°
R
,0
(0,86)
M20x1,5
1.6
Ø0.05 A B
90° Ø0.04
(0,75 Max)
18,5 ±0,1
13 Max
,2
+0,1
0
1.6
(0,73) R0 ,01)
(0,90)
0,5
(0,92)
+0,5
(0
23,5
23 0
15,8 ±0,05
(0,09)
+0,4
15°
2,4 0
(0,62)
(1,38)
35 ±0,1
(0,59)
+0,5
15 0
(0,55)
45
(0,79)
14
2
20
(1,77)
R0
(0,09)
+0,4
29 ±0,1
45
(1,14)
(0 ,2
2,4 0
,01
)
2
+0,5
(1,54)
39 0
1.6
43,5
(1,71)
45°
(0,01x45°)
0,2x45°
1
1
12,5 Max
(0,75 Max)
(0,49)
13 Max
12 Max
(0,47)
M14x1,5
Ø0.05 A B
Ø0.04
1
13 Max
(0,75 Max)
mm [Inches] mm [Inches]
200 201
Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
Fluid-app Srl reserves the right to modify its products without notice.
Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
CAVITY FC004 (VBC2250 VALVE) FC005 (M80 VALVE)
+0,5
29 0
(1,14)
+0,1
25,8 0
28
(1,10) 15° (1,02)
23 M24x1,5
30°
(0,91) 22,5 ±0,1
1.6
1.6
M22x1,5 (0,88)
Ø0.05 A +0,033
+0,05 21 H8 0
+0,1
0.05 B 19 0
8)
0, ,2
(0,02)
0
0,5 -0,2
(R R0
(0,83)
(0,02)
00
0
(0,14)
(0,75)
0,5
1.6
0,5
3,5
1.6
(0,09)
+0,4
14,5 ±0,1
2,4 0
(0,57)
(0,51)
(0,59)
(0,65)
+0,5
15 0
13
15
(0,79)
°
+0,2
(0,83)
° 45
20 0
45
21
3 2
+0,2
(1,26)
(1,30)
(1,43 Min)
36,5 Min
32 0
33
(1,53)
39
0,37 Max)
(0,39)
9,5 Max
10
(2,01)
1,97
50
30
51
54,5 -0,2
(2,15)
°
1.6
2
(
1
0,37 Max)
9,5 Max
°
30
(0,39)
10
1
(
0,37 Max)
9,5 Max
1
9,5
(0,37)
1
(
1.6
+0,05
10
A 18 0 (0,39)
20 ±0,1
(0,79)
mm [Inches] mm [Inches]
202 203
Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
Fluid-app Srl reserves the right to modify its products without notice.
Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
VBA VU
E
H (max)
1 2
H (max)
118
F
2
F
1
G
L (max)
CAVITY VALVE F
CODE CODE
TYPE
ports
E G H TECHNICAL CHARACTERISTICS mm [Inches]
F1B F2B
FC111 FA3036 VUC1B 1/4 BSPP 7 [0,27]
9,5 max
38
7 max
(1,5) 39
(1,53) FC114 FA3039 VUC4B 3/4 BSPP 18 [0,70]
2 1
2 1 VUD FC120 FA3040 VUD0B 1/8 BSPP 5 [0,19]
204 205
Via Garonna n° 26, 42124 Reggio Emilia - ITALY www.fluid-app.it sales@fluid-app.it
Fluid-app Srl reserves the right to modify its products without notice.
Fluid-app Srl si riserva il diritto di modificare i propri prodotti sen a preavviso.
notes
206 207
notes
208
FOR
T IONS MER. LITY.
O L U STO QUA
S CU ENT CK.
T H E ST DBA
S I
CON F EE . E R.
C K Y T H
QUI XIBILITTOGE
FLE WING
GRO
TION
F O RMA
I N
FOR pp.it
fl u id-a
s@
sale
L US
CAL 451
22 1722
05
+39
P
H ATSAP
W
US A
SEND 6 33
48
0 1 5
37 RKS
+39 TWO
N E
CIAL
K O N SO
TAL
LET’S
ITALY
milia -
.IT gio E
APP 124 R
eg
. F L UID- - 42
W W ° 2 6
W na n 1
aron 2245
Via G 0 5 22 17
9
e +3 pp.it
Phon id-a
@ fl u
l e s
sa