oilguardPRO
INNOVATIVE RESIDUAL OIL CONTENT MEASUREMENT FOR COMPRESSED AIR SYSTEM
MONITORING · CONTROL · SAFETY
RESIDUAL OIL
CONTENT
MEASUREMENT
oilguardPRO
oilguardPRO constantly monitors – with a measuring range of 0,001 - 20 mg/m3 – the residual oil content
and in turn the quality of compressed air to avoid contamination in the plant because of hydrocarbons; a
specially developed metal oxide sensor constantly detects any deviation from standard value and gives an
indication.
the measured value can be easily passed on further through a 4 - 20 mA-output as well as potential free
contacts to externally connected components (control, transducer, etc.) and can be graphically represented
with the help of an optionally available software.
8 8
5
6 8
7
4
8 3
FACTS FUNCTIONING
· oilguardPRO checks and protects the the withdrawal of compressed air is done over surface works as a catalyst and the hydrocar-
production well in advance before oil ingress a heated sampling system (8). at the sensor bons contained in compressed air gets oxidised.
due to hairline cracks in filters and fine cuts head (1) the gas sample is taken out through a at the boundary surface the metallic oxide par-
sintered metal filter disc and heated in a spiral- ticle, the load river is minimized due to oxygen
· oilguardPRO monitors the active charcoal
shaped arrangement, flow expansion capillary deficiency and the change in conductance so
absorber as well as the converter
(3). by the centrifugal force, the aerosol compo- adjusted is electronically evaluated.
· oilguardPRO constantly monitors online the
nents get evaporated at the capillary wall. with
the software in the microprocessor controlled
compressed air, which comes into contact with
a pressure regulator (4) the desired flow rate is
evaluation unit (9) analyses the change in signal
production – as compared to sampling, which
achieved. at the outlet of the capillary (5) the
through mathematical algorithms and determi-
only reflects a snapshot of the compressed air
test air expands to nearly ambient pressure and
nes the hydrocarbon content in test gas with the
quality belonging to the past
through the analysis cuvette (6) comes into con-
help of stored calibration tables. for typical CH-
· oilguardPRO saves maintenance costs tact with the sensor element (7). the evaluated
mass distribution of compressor oil, the oil con-
because filter, adsorbent etc. are continuously test air is set free into the atmosphere through a
tent is calculated and displayed in mg/m3 from
checked and hence the ideal time to change filter.
the values stored in the device. the measured
any parts can be planned before
heart of the sensing system is a metal oxide values are provided in both analogue and digi-
· oilguardPRO gives security, since it can semiconductor sensor specially tailor made as tal format and the alarm and relay outputs are
immediately respond to dangerous situations per the application, which is optimised with the triggered.
over an early and main alarm help of active coating additives for detection of
long chain hydrocarbons. through platinum
and palladium refinement, the 330 °C hot sensor
oilguardPRO
TECHNICAL DATA
MEASURING PROBE
calibrated measuring range 0,01 ... 20 mg/m3 total residual oil content
0 ... 2 ppm hydrocarbon concentration based on hexane (C6H14)
application range DTP < 7 °C tpd, after cold dryer
detected materials alkane, alkanol and other oil components, VOC (volotile organic compund),
other oxidisable materials like NOx, water vapour
measuring medium clean, filtered compressed air (filtered and dried, ISO 8573-classes 2-4-2)
(free from aggressive, corrosive, poisonous, inflammable, oxidising components and silanes)
measuring accuracy 5 ppb at zero point, based on hexane (C6H14)
pressure application range 4 ... 10 bar
temperature application range 0 ... 50 °C
rinse air consumption 50 ml/min at 10 bar
senor element metal oxide-sensor (MOS) integrated in wall housing
probe connection G1/2“ AG
CONTROL UNIT
display range 0,001 ... 20 mg/m3
voltage supply 85 - 250 V, 50 - 60 Hz
operating voltage 24 V / max. 2 A
current consumption max. 48 mA
dimensions 300 x 400 x 130 mm (without screw connections, cable glands and warning light)
relay output (main alarm) potential free normally open 30 V / 2 A AC/DC, adjustable switching polarity
relay output (pre-alarm) potential free normally open 30 V / 2 A AC/DC, adjustable switching polarity
light alarm output 15 V DC/50 mA, active
buzzer alarm output 15 V DC/50 mA, active
analogue output 4 ... 20 mA
serial output RS 485 with 38400 baud, optional USB-connection
EMV noise immunity EN 61000-6-3
EMV noise emission EN 61000-6-3
guarantee 24 months
scope of supply measuring instrument in wall housing with acoustic sensor, test certificate and documentation