For Gas

Dual Display Digital Pressure Sensor


DP-100 SERIES Ver.2

Ver.2

* The contents of this catalog are as of October 2017.


2022.8
For the latest information, please visit our company website.
Dual Display Digital Pressure Sensor
2
For Gas

DP-100 SERIES Ver.2

Ver.2 Recognition

Certified
[DP-101(A)/102(A) only]

* Passed the UL 991 Environment Test


* UL 61010C-1 compatible, Passed the UL 991
Environment Test based on SEMI S2-0200.
[Category applicable for semiconductor
manufacturing: TWW2, Process Equipment]
[Applicable standards: UL 61010C-1]
[Additional test / evaluation standards as per intended
use: UL 991, SEMI S2-0200]

Digital Auto reference With analog


output

Dual 3-color display makes operation easier!

Achieved further efficiency with 4 upgrades, keeping the same operability

UPGRADE 1
Superior visibility
Improved visibility in Digital Display
Improvements to the digital display deliver a wide
viewing angle along with increased clarity. The display
pressure range and set pressure range have also been
increased.

Old DP-100 series New DP-100 series

UPGRADE 2
Long-distance transmission of analog output
Addition of analog current output capability to multifunctional models
Users can now select either voltage output or current output as analog output according to their application.
Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2
3

APPLICATIONS

Confirming suction of electronic component Confirming reference pressure Air-leak test for PET bottles

UPGRADE 3
Reduced environmental impact 14 % lower
14 % lower power consumption (during normal operation) after update

Thanks to a redesign of its circuitry, power consumption


of the low-power-consumption DP-100 series during
normal operation has been reduced by 14 %. The
display is shut off entirely during ECO / FULL mode
operation for power savings of up to 50 % compared Old DP-100 series New DP-100 series
to normal operation, and display brightness is lowered 840 mW (normal operation) 720 mW (normal operation)
during ECO / STD mode operation for power savings of
up to 30 % compared to normal operation.
Up to 50 % lower
in ECO mode

Normal operation ECO / FULL operation


720 mW 360 mW

UPGRADE 4
Enhanced power circuitry
Addition of a reverse polarity protection circuit to the transistor output circuit
To prevent from breakage due to miswiring.

“Current value” and “threshold value” can be checked at the same time!
Dual display allows direct setting of threshold value
Equipped with a 30 mm 1.181 in square compact-sized dual display. The Current
current value and the threshold value can be checked at the same time, so value
the threshold value can be set and checked smoothly without switching to
another screen mode. ON/OFF operations still continue while the threshold
values are being set, so setting to the same sensitivity as dial control-type
sensors is possible. Key lock function is equipped as well.

Threshold
value
4 Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2

3-color display (Red, Green, Orange) Readable digital display!


The main display changes color in line with changes Alphanumeric indication in 12 segments is used. This
in the status of output ON/OFF operation, and it also improved visual checking.
changes color while setting is in progress. The sensor
status can therefore be understood easily, and operating
errors can be reduced.

OFF: Green (or Red) ON: Red (or Green) SET: Orange
Main
Display

During normal operation During setting

BASIC PERFORMANCE
All models in the line-up are compound pressure types High performance accomplished Low pressure type
No sensor settings are required to switch between positive pressure and negative The low pressure type displays measurements in 0.1 kPa
pressure, so that the number of registered part numbers can be decreased. at a resolution of 1/2,000 and has a response time of 2.5
ms (variable up to 5,000 ms), ±0.5 % F.S. temperature
<For low pressure> characteristics and ±0.1 % F.S. repeatability, giving it
Ideal for applications such high performance.
as suction.
No mis-operations due to <For high pressure>
vacuum breakdown occur. Ideal for applications such as
checking reference pressure.
Resolution: 1/2,000
–100 kPa 0 kPa 100 kPa Can also be used for simple Response time: 2.5 ms
For low suction.
pressure DP-101□ Temperature characteristics: ±0.5 % F.S.
1 MPa
Repeatability: ±0.1 % F.S.
For high
pressure DP-102□
Displays measurements in 0.1 kPa

FUNCTIONS
Copy function reduces man-hours and human error
Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data
to other sensors. If making the same settings for multiple sensors, this prevents setting errors among other sensors and in addition, when
machinery design are changed, there would be less change in work orders.
Details transmitted

Copying via wiring


Master sensor Slave sensor Details received
Power supply
Detail
+V +V
s cop
0V 0V ied
Comparative output 1 Comparative output 1

Comparative output 2 Comparative output 2

Note: Settings cannot be copied from the new version (Ver. 2) to the old version.
However, settings can be copied from the old version to the new version (Ver. 2).

The sensor’s setting operation mode has a 3-level configuration to suit the frequency of use
The setting levels are clearly separated into “RUN mode”
for operation settings that are carried out daily, “MENU RUN mode
SETTING mode” for basic settings, and “PRO mode” Settings such as threshold value
for special and detailed setting. These make setting adjustment and key lock operation
operations easy to understand and easy to carry out. can be carried out while the sensor
is operating.

MENU SETTING mode


Simple setting RUN mode
Basic settings such as output mode
setting and NO/NC switching can be
carried out.
MENU SETTING mode
PRO mode

Special and PRO mode High-level function settings such as


detailed setting
hysteresis adjustment and the copy
function can be carried out.
Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2
5

FUNCTIONS
Equipped with independent dual output and three output modes Standard type

Equipped with two independent comparative outputs, 1 EASY mode


and separate sensing modes can be selected for each
This mode is used for comparative output ON/OFF control.
of them. Since there are two comparative outputs, one
of the comparative outputs can even be used for alarm H (Hysteresis)

Pressure
output. In addition, output, which is not being used, can P
be disabled.
0
Vacuum breakdown can also be notified during suction applications! ON
Comparative output H: Fixed
OFF
Notes: 1) Hysteresis can be fixed to one of eight different levels.
ON
Comparative output 1 2) “ ”appears in the sub display for comparative output 1, and
EASY mode Suction checking “ ” appears for comparative output 2.
OFF
2 Hysteresis mode
ON This mode is used for setting comparative output hysteresis
Comparative output 2
EASY mode to the desired level and for carrying out ON/OFF control.
OFF
Vacuum breakdown checking

Pressure
Hi
–100 kPa P-1 0 kPa P-2
H (Hysteresis)
Lo
0
Reference pressure alarm output is possible during reference pressure checking! ON
Comparative output H: 1 digit or more
OFF

Note: “ ” or “ ” appears in the sub display for comparative


ON Reference
Comparative output 1 output 1, and “ ” or “ ” appears for comparative output 2.
pressure
Hysteresis mode checking
OFF 3 Window comparator mode

Alarm output
This mode is used for setting comparative output ON
ON and OFF at pressures within the setting range.
Comparative output 2
EASY mode
OFF H (Hysteresis)
Pressure

Hi
H (Hysteresis)
0 kPa Lo-1 Hi-1 P-2 Lo
0
ON
Comparative output H: Fixed
OFF
Notes: 1) Hysteresis can be fixed to one of eight different levels.
2) “ ” or “ ” appears in the sub display for comparative
output 1, and “ ” or “ ” appears for comparative output 2.

Possible to switch over analog output and external input Multi-function type

Multi-function type that enables the selection of analog output (voltage/current) or external input (auto-reference/
remote zero-adjustment) is available. It complies a wide range of applications.

Comparative output

is lighting.
Voltage Low pressure type: 1 to 5 V,
Analog output High pressure type: 0.6 to 5 V
Selection Current Low pressure type: 4 to 20 mA,
High pressure type: 2.4 to 20 mA
Multi-function type or
External input Auto-reference/remote zero-adjust
6 Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2

FUNCTIONS
Equipped with auto-reference/remote zero-adjustment functions. More precise pressure management is achieved with a minimum of effort Multi-function type
If the reference pressure of the device changes, two functions are selectable.
One is auto-reference function, which partially shift the comparative output
judgment level by the amount that the reference pressure shifts. The other
is remote zero-adjustment function, which can reset the display value to zero
via external input. These functions are ideal for places where the reference
pressure fluctuates wildly, or where fine settings are required.

With auto-reference function applied With remote zero-adjustment function applied


Comparative output: Window comparator mode Comparative output: Window comparator mode
Hi-1…0, Lo-1…–5 Hi-1…0, Lo-1…–5
Sets the absolute threshold level Sets the absolute threshold level
Auto-reference input Remote zero-adjustment input
The display remains at “30” and The display is forced to “0”, and only the
only the threshold level is changed. filling pressure drop range is displayed.

30 30
0
25 OK 25 –5 OK
20 20
Threshold level after applying Threshold level after applying
auto-reference input remote zero-adjustment input
15 15
Threshold level before applying Threshold level before applying
auto-reference input remote zero-adjustment input
Trial 1 Trial 1
Pressure 0 Pressure 0
Displayed when remote zero-adjustment
–5 Auto-reference input value… –5 input is applied…
Time Time
When auto-reference input is applied, the reference pressure “30” When remote zero-adjustment input is applied, the reference
is added to the threshold level. If the reference pressure changes pressure is forced to “0”. If the reference pressure changes to
to “20” or “40”, the auto-reference input compensates for this “20” or “40”, the remote zero-adjustment input adjusts the
every time by changing the threshold level, so any variation in reference pressure to “0” every time the reference pressure
the filling pressure can be ignored. changes, so any variation in the filling pressure can be ignored.

Sub display can be customized Setting details can be recognized at a glance


The sub display can be set to indicate any other desired The DP-100 setting details appear in the digital display.
values or letters apart from the threshold value. This Because the settings are in numeric form that can be
eliminates the need for tasks such as affixing a label to easily understood, it is useful such as when receiving
the device to indicate the normal pressure value. technical support by telephone.
2nd digit: Setting status for
comparative output 2 3rd digit: Threshold value setting
1st digit: Setting status for 4th digit: Display color setting
comparative output 1

5th digit: Response time


setting 8th digit: ECO mode setting
6th digit: Display unit setting 7th digit: Display refresh rate setting

Peak hold and Bottom hold functions Energy-saving design! Equipped with an ECO mode
The peak values and bottom values for fluctuating This mode lowers the display luminance to cut power
pressures can be displayed using the dual display. consumption by approximately 30 %. The displays can
also be turned off completely to achieve a power saving
of approximately 50 %.
Power consumption Power consumption
Approx. Approx.
Normal ECO-STD 30 % less ECO-FULL 50 % less

Blinks alternately

Current consumption for Current consumption for Current consumption for


24 V power supply: 30 mA or less 24 V power supply: 20 mA or less 24 V power supply: 15 mA or less
DP-100 SERIES Ver.2
Dual Display Digital Pressure Sensor
7

MOUNTING
Tight installation to panels is possible
An exclusive mounting bracket that is suitable for 1 to 6
mm 0.039 to 0.236 in panel thickness is available.
Tight installation is possible Front protection
Neat and cover available
space MS-DP1-3
saving

A single mounting hole!

An exclusive mounting bracket (MS-DP1-1) that supports tight installation is available

Space savings can also be achieved even when an L-shaped mounting bracket is used.

• MS-DP1-1 • MS-DP1-5
Tight installation is possible

Ceiling mounting Floor mounting Rear mounting Positioning bosses for easier
mounting bracket installation

Types without connector attached


Cable can be connected with one-touch cable are also available DP-10□-J

Connector attached cable (2 m Commercially-available connectors can be used for


6.562 ft), as an accessory, can be cable connections. Cables in required length can
connected easily with one-touch be used, so this contributes to reduction in waste of
connection. unwanted cables.

Environmentally
friendly

* Connection cable
Commercially-available
parts can be used!
* Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft types are also available.

* Refer to p.10 for recommended commercially-available connectors.


8 Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2

VARIETIES
Short pressure port type is lightweight and takes up little space DP-10□-M

Compact size with a depth of only 30 mm 1.181 in, so


that it can easily fit into narrow spaces. Standard type M5 female thread + R 1/8 male thread
Further, 10 g lighter than standard types. This reduces
the loads on movable parts such as robot arms. Elbow joint

Short pressure
port type DP-10□-M(-P)

Short pressure port type


DP-10□-M(-P)

Shortened to
12.5 mm 0.492 in !
Light weight
30g approx.
M5 female thread
30 mm [Material: Stainless steel (SUS)]
1.181 in

* The illustration shows connection using an elbow joint.


The elbow joint is sold separately.

M8 plug-in connector types are also available (Only for Europe) DP-11□-E-P-J

M8 connector
Mating cable
CN-24A-C2 (cable length 2 m 6.562 ft)
CN-24A-C5 (cable length 5 m 16.404 ft)

G 1/8 male thread


M5 female thread

Flat installation on the wall by shifting the direction Rc1/8 conversion bushing is available. Compatible
of the pressure port For short pressure port type with conventional model For short pressure port type
By mounting the flat By equipping the push-in converter with DP-10□-M(-P),
attachment to DP-10□-M(-P), pressure port can be converted from M5 female thread
pressure port and cable can to Rc1/8 female thread.
now be pulled out in downward, Conventional model DP2 / DP3
Bore diameter conversion to the DP2 / DP3 series is
left or right directions. Flat series can be switched over to possible.
mounting on surfaces such as DP-100 series.
the wall is made possible.
Conventional model M5 female thread Rc1/8 female thread

Flat attachment
MS-DP1-F□

20 mm 20 mm
0.787 in pitch 0.787 in pitch
Conversion bushing
Model No. Pressure port MS-DP1-7

MS-DP1-FM M5 female thread


MS-DP1-FR Rc1/8 female thread
MS-DP1-FN NPT1/8 female thread
3 possible directions to mount MS-DP1-FE G1/8 female thread
Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2
9

ORDER GUIDE

Type Appearance Rated pressure range Model No. Pressure port Comparative output

For low pressure −100.0 to +100.0 kPa DP-101


Standard M5 female thread
For high pressure −0.100 to +1.000 MPa DP-102 +
Asia

NPN open-collector transistor


For low pressure −100.0 to +100.0 kPa DP-101A R 1/8
Multi-function male thread
For high pressure −0.100 to +1.000 MPa DP-102A
For low pressure −100.0 to +100.0 kPa DP-101-E-P
Standard M5 female thread
For high pressure −0.100 to +1.000 MPa DP-102-E-P +
PNP open-collector transistor
For low pressure −100.0 to +100.0 kPa DP-101A-E-P G 1/8
Standard pressure port type

Multi-function male thread


−0.100 to +1.000 MPa DP-102A-E-P
Europe

For high pressure


For low pressure DP-111-E-P-J
M8 plug-in connector type

−100.0 to +100.0 kPa


Standard M5 female thread
For high pressure −0.100 to +1.000 MPa DP-112-E-P-J +
PNP open-collector transistor
For low pressure −100.0 to +100.0 kPa DP-111A-E-P-J G 1/8
Multi-function male thread
For high pressure −0.100 to +1.000 MPa DP-112A-E-P-J
DP-101-N NPN open-collector transistor
For low pressure −100.0 to +100.0 kPa
DP-101-N-P PNP open-collector transistor
Standard
DP-102-N NPN open-collector transistor
North America

For high pressure −0.100 to +1.000 MPa M5 female thread


* CN-14A-C2 DP-102-N-P PNP open-collector transistor
+
( Connector attached
cable 2 m 6.562 ft) DP-101A-N NPT 1/8 NPN open-collector transistor
For low pressure is attached. −100.0 to +100.0 kPa male thread
DP-101A-N-P PNP open-collector transistor
Multi-function ( Excluding M8 plug-in
connector type ) DP-102A-N NPN open-collector transistor
For high pressure −0.100 to +1.000 MPa
DP-102A-N-P PNP open-collector transistor
DP-101-M NPN open-collector transistor
For low pressure −100.0 to +100.0 kPa
Short pressure port type

DP-101-M-P PNP open-collector transistor


Standard
DP-102-M NPN open-collector transistor
For high pressure −0.100 to +1.000 MPa
DP-102-M-P PNP open-collector transistor
Asia

M5 female thread
DP-101A-M NPN open-collector transistor
For low pressure −100.0 to +100.0 kPa
DP-101A-M-P PNP open-collector transistor
Multi-function
DP-102A-M NPN open-collector transistor
For high pressure −0.100 to +1.000 MPa
DP-102A-M-P PNP open-collector transistor

Type without connector attached cable


Type without connector attached cable CN-14A-C2 is available.
When ordering this type, suffix “-J” to the Model No. (Excluding M8 plug-in connector type and short pressure port type)
(e.g.) Type without connector attached cable of DP-101-N is “DP-101-N-J”

Accessory
• CN-14A-C2
(Connector attached cable 2 m 6.562 ft)
10 Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2

OPTIONS

Connector attached cable


Designation Model No. Description • CN-14A-C□
• CN-14A-R-C□
CN-14A-C1 Length: 1 m 3.281 ft
0.2 mm2 4-core cabtyre cable with
Connector CN-14A-C2 (Note) Length: 2 m 6.562 ft
attached cable connector on one end
CN-14A-C3 Length: 3 m 9.843 ft Cable outer diameter: ø3.7 mm ø0.146 in
CN-14A-C5 Length: 5 m 16.404 ft
CN-14A-R-C1 Length: 1 m 3.281 ft
Connector 0.2 mm2 4-core bending-resistant cabtyre
CN-14A-R-C2 Length: 2 m 6.562 ft
attached cable cable with connector on one end M8 connector attached cable
(
Bending-resistant
cable ) CN-14A-R-C3
CN-14A-R-C5
Length: 3 m 9.843 ft
Length: 5 m 16.404 ft
Cable outer diameter: ø3.7 mm ø0.146 in
• CN-24A-C□

M8 connector CN-24A-C2 Length: 2 m 6.562 ft For M8 plug-in connector type


The connector on one end
attached cable
CN-24A-C5 Length: 5 m 16.404 ft Cable outer diameter: ø4 mm ø0.157 in
Connector CN-14A Set of 10 housings and 40 contacts
Allows sensors to be installed on the flooring or ceiling.
Sensor MS-DP1-1 Multiple sensors can also be mounted closely.
mounting 31.4 ø4
bracket Allows sensors to be installed on the wall. Multiple sensors 1.236 ø0.157
MS-DP1-5 can also be mounted closely.
Allows installation to panels with thickness of 1 to 6 mm 0.039
MS-DP1-2 to 0.236 in. Multiple sensors can also be mounted closely. ø9
Panel mounting ø0.354 (Unit: mm in)
bracket Allows replacement from DP2 / DP3 series to DP-100 series. For newly designed
MS-DP1-4 set-up, please use panel mounting bracket MS-DP1-2 for panel mounting.
Protects the adjustment surfaces of sensors. Sensor mounting bracket
MS-DP1-3 (Can be attached when using the panel mounting bracket MS-DP1-2) • MS-DP1-1
Front protection
cover Protects the adjustment surfaces of sensors.
DPX-04 M3 (length 6 mm 0.236 in)
(Can be attached when using the panel mounting bracket MS-DP1-4) screws with washers

Conversion
MS-DP1-7
By equipping with DP-10□-M(-P), pressure port can be converted to (Accessory for
MS-DP1-1 )
bushing Rc1/8 female thread. Replacement from DP2 / DP3 series is possible.
MS-DP1-FM M5 female thread For DP-10□-M(-P) Sensor mounting
bracket
Flat MS-DP1-FR Rc1/8 female thread Pressure port and cable can now be
MS-DP1-1
attachment pulled out in downward, left or right
MS-DP1-FN NPT /8 female thread directions. Flat mounting on surfaces
1

MS-DP1-FE G1/8 female thread such as the wall is made possible.


Note: The connector attached cable CN-14A-C2 is supplied with the DP-100 series. • MS-DP1-5
(Excluding M8 plug-in connector type). M3 (length 6 mm 0.236 in)
screws with washers

(Accessory for
MS-DP1-5 )
Panel mounting bracket, Front protection cover
• MS-DP1-2 • MS-DP1-4 DP2 / DP3
• MS-DP1-3 Sensor mounting
Front protection cover
DP
2-2
0

ñ101
.3kP
bracket
MS-DP1-5
a

DPX-04 (optional) Remove


OUT
1

OUT
0-AD 2
J
MOD
E

can be installed on
MS-DP1-4.
Front protection cover Remove
MS-DP1-3

Insert
Mounting holes
Conversion bushing
DP-100
for DP2 / DP3 series • MS-DP1-7 M5 female Rc1/8 female
can be used as is. thread thread
Panel mounting bracket Panel mounting bracket MS-DP1-4
MS-DP1-2

Flat attachment
• MS-DP1-FM • MS-DP1-FR
• MS-DP1-FN Conversion bushing
• MS-DP1-FE MS-DP1-7

Recommended connector
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Net weight: MS-DP1-FM 15g approx.
Note: Contact the manufacturer for details of the
MS-DP1-FR/FN/FE 25g approx. recommended products.
Two M3 (length 8 mm 0.315 in) screws,
two M4 (length 20 mm 0.787 in) screws Recommended crimping tool
are attached.
Model No.: YC-610R
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the
recommended products.

Recommended connector (e-CON)


Applicable connector: 37104-3122-000 FL
(Manufactured by 3M Japan Limited)
Note: Contact the manufacturer for details of the
recommended products.
Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2
11

SPECIFICATIONS

Standard Multi-function
Type
For low pressure For high pressure For low pressure For high pressure
Asia (Note 2) DP-101(-M)(-P) DP-102(-M)(-P) DP-101A(-M)(-P) DP-102A(-M)(-P)
Model No.

Europe DP-101-E-P DP-102-E-P DP-101A-E-P DP-102A-E-P


M8 plug-in connector type DP-111-E-P-J DP-112-E-P-J DP-111A-E-P-J DP-112A-E-P-J
Item North America (Note 2) DP-101-N(-P) DP-102-N(-P) DP-101A-N(-P) DP-102A-N(-P)
CE marking directive compliance EMC Directive, RoHS Directive
Type of pressure Gauge pressure
Rated pressure range −100.0 to +100.0 kPa −0.100 to +1.000 MPa −100.0 to +100.0 kPa −0.100 to +1.000 MPa
−101.0 to +101.0 kPa −0.101 to +1.010 MPa −101.0 to +101.0 kPa −0.101 to +1.010 MPa
−1.030 to +1.030 kgf/cm2 −101 to +1,010 kPa −1.030 to +1.030 kgf/cm2 −101 to +1,010 kPa
−1.010 to +1.010 bar −1.03 to +10.30 kgf/cm2 −1.010 to +1.010 bar −1.03 to +10.30 kgf/cm2
Set pressure range −14.64 to +14.64 psi −14.64 to +14.64 psi
−1.01 to +10.10 bar −1.01 to +10.10 bar
−757 to +757 mmHg −757 to +757 mmHg
−29.8 to 29.8 inHg −14.6 to +146.4 psi −29.8 to 29.8 inHg −14.6 to +146.4 psi

Pressure withstandability 500 kPa 1.5 MPa 500 kPa 1.5 MPa
Applicable fluid Non-corrosive gas
Selectable unit For low pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm2, bar, psi
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
Power consumption ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage)
360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage)
<Asia (NPN output), North America (NPN output)> <Asia (PNP output), Europe, North America (PNP output)>
Comparative output NPN open-collector transistor PNP open-collector transistor
Comparative output 1, • Maximum sink current: 100 mA • Maximum source current: 100 mA
Comparative output 2 (Note 3) • Applied voltage: 30 V DC or less (between comparative output and 0 V) • Applied voltage: 30 V DC or less (between comparative output and +V)
• Residual voltage: 2 V or less (at 100 mA sink current) • Residual voltage: 2 V or less (at 100 mA source current)
Output operation / Output modes NO/NC (selectable by key operation) / EASY mode / Hysteresis mode / Window comparator mode
Hysteresis Minimum 1 digit (variable) (however, 2 digits when using psi unit)
Repeatability ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits) ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits)
Response time 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Short-circuit protection Incorporated
<Asia (NPN output), North America (NPN output)> <Asia (PNP output), Europe, North America (PNP output)>
External input (Note 4)
ON voltage: 0.4 V DC or less ON voltage: 5 V to +V DC
Auto-reference function /
OFF voltage: 5 to 30 V DC, or open OFF voltage: 0.6 V DC or less, or open
Remote zero-adjustment
Input impedance: 10 kΩ approx. Input impedance: 10 kΩ approx.
function
Input time: 1 ms or more Input time: 1 ms or more
Output voltage: 1 to 5 V DC Output voltage: 0.6 to 5 V
Zero point: within 3 V ±5 % F.S. Zero point: within 1 V ±5 % F.S.
Analog voltage output (Note 4) Span: within 4 V ±5 % F.S. Span: within 4.4 V ±5 % F.S.
Linearity: within ±1 % F.S. Linearity: within ±1 % F.S.
Output impedance: 1 kΩ approx. Output impedance: 1 kΩ approx.
Output current: 4 to 20 mA Output current: 2.4 to 20 mA
Zero point: 12 mA ±5 % F.S. Zero point: 4 mA ±5 % F.S.
Analog current output (Note 4) Span: 16 mA ±5 % F.S. Span: 17.6 mA ±5 % F.S.
Linearity: within ±1 % F.S. Linearity: within ±1 % F.S.
Load resistance: 250 Ω (max.) Load resistance: 250 Ω (max.)
Display 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
−101.0 to +101.0 kPa −0.101 to +1.010 MPa −101.0 to +101.0 kPa −0.101 to +1.010 MPa
−1.030 to +1.030 kgf/cm2 −101 to +1,010 kPa −1.030 to +1.030 kgf/cm2 −101 to +1,010 kPa
−1.010 to +1.010 bar −1.03 to +10.30 kgf/cm 2 −1.010 to +1.010 bar −1.03 to +10.30 kgf/cm2
Displayable pressure range −14.64 to +14.64 psi −14.64 to +14.64 psi
−1.01 to +10.10 bar −1.01 to +10.10 bar
−757 to +757 mmHg −757 to +757 mmHg
−29.8 to 29.8 inHg −14.6 to +146.4 psi −29.8 to 29.8 inHg −14.6 to +146.4 psi
Orange LED Orange LED
Indicator
( Comparative output 1 operation indicator, comparative output 2 operation indicator:
Lights up when each comparative output is ON )( Comparative output 1 operation indicator: Lights up when comparative output is ON,
Analog voltage output operation indicator: Lights up when setting )
Protection IP40 (IEC)
Environmental resistance

Ambient temperature −10 to +50 °C +14 to +122 °F, Storage: −10 to +60 °C +14 to +140 °F
Ambient humidity 35 to 85 % RH (No dew condensation or icing allowed), Storage: 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
Vibration resistance
(when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Temperature characteristics Within ±0.5 % F.S. (at +20 °C +68 °F) Within ±1 % F.S. (at +20 °C +68 °F) Within ±0.5 % F.S. (at +20 °C +68 °F) Within ±1 % F.S. (at +20 °C +68 °F)
Pressure port Asia: M5 female thread + R (PT) 1/8 male thread [excluding DP-□-M(-P)], Europe: M5 female thread + G 1/8 male thread, North America: M5 female thread + NPT 1/8 male thread
Material Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Connecting method / Cable length Connector / Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable.
Weight Net weight: 40 g approx. (DP-10□-M(-P): 30 g approx.), Gross weight: 130 g approx. (DP-10□-M(-P):120 g approx.)
Accessories CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc. (excluding M8 plug-in connector type)
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Model Nos. of Asia type having “-M” are short pressure port type. Model Nos. of Asia and North America types having the suffix “-P” are PNP output type.
3) Only standard type is equipped with comparative output 2.
4) Cannot be used at the same time.
12 Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2

I/O CIRCUIT AND WIRING DIAGRAMS

DP-10□ NPN output type


I/O circuit diagrams Terminal No. Multi-function type Terminal No.
Color code of connector attached cable
Standard type Color code of connector attached cable
(Brown) +V
(Brown) +V 1
1 5V D1
D1 (Black) D3 (White) Analog output
D2 Load Tr1

Sensor circuit
Comparative output 1 3
or External input Load
Sensor circuit

Tr1 2
Load + 12 to 24 V DC
100 mA max. + 12 to 24 V DC 1kΩ D2 (Black) Comparative output 1 ±10 %
ZD1 D3 (White) Comparative output 2 Tr2 2 −
− ±10 %
Tr2 3
100 mA max.
100 mA max. ZD
ZD2
(Blue) 0 V
(Blue) 0 V 4
4
Internal circuit Users’ circuit
Internal circuit Users’ circuit
Symbols • • • D1 to D3 : Reverse supply polarity protection diode
Symbols • • • D1 to D3 : Reverse supply polarity protection diode ZD : Surge absorption zener diode
ZD1, ZD2 : Surge absorption zener diode Tr1 : PNP input transistor
Tr1, Tr2 : NPN output transistor Tr2 : NPN output transistor
Terminal arrangement diagram
Terminal Designation
1 +V
2 Comparative output 1
Standard type: Comparative output 2
3
Multi-function type: Analog output or External input
1 2 3 4 4 0V

DP-10□-P PNP output type


I/O circuit diagrams Terminal No.
Multi-function type Terminal No.
Color code of connector attached cable
Standard type Color code of connector attached cable
(Brown) +V
1
(Brown) +V D1
1
D ZD
Tr1 100 mA max.
Sensor circuit

ZD1
100 mA max.
Sensor circuit

2 +
(Black) Comparative output 1 12 to 24 V DC
Tr1 2 + 1kΩ D3 ±10 %
ZD2 (Black) Comparative output 1 12 to 24 V DC −
±10 % Tr2 3
(White) Analog output Load
100 mA max. − or External input
Tr2 3
Load D2
(White) Comparative output 2 (Blue) 0 V
Load 4
(Blue) 0 V
4
Internal circuit Users’ circuit
Internal circuit Users’ circuit
Symbols • • • D1 to D3 : Reverse supply polarity protection diode
Symbols • • • D : Reverse supply polarity protection diode ZD : Surge absorption zener diode
ZD1, ZD2 : Surge absorption zener diode Tr1 : PNP output transistor
Tr1, Tr2 : PNP output transistor Tr2 : NPN input transistor

Terminal arrangement diagram Terminal Designation


1 +V
2 Comparative output 1
Standard type: Comparative output 2
3
Multi-function type: Analog output or External input
1 2 3 4 4 0V

DP-11□-E-P-J PNP output type


I/O circuit diagrams Terminal No. Multi-function type Terminal No.
Color code of connection cable
Standard type Color code of connection cable
(Brown) +V
1
(Brown) +V
1 D1
D ZD
Tr1 100 mA max.
Sensor circuit

ZD1
100 mA max.
Sensor circuit

4 + 12 to 24 V DC
Tr1 1k (Black) Comparative output 1
4 + 12 to 24 V DC ±10 %
ZD2 (Black) Comparative output 1 −
100 mA max. − ±10 % Tr2 (White) Analog voltage output Load
2
Tr2 2
Load D2 or External input
(White) Comparative output 2
Load (Blue) 0 V
3
(Blue) 0 V
3
Internal circuit Users’ circuit
Internal circuit Users’ circuit
Symbols • • • D1, D2 : Reverse supply polarity protection diode
Symbols • • • D : Reverse supply polarity protection diode ZD : Surge absorption zener diode
ZD1, ZD2 : Surge absorption zener diode Tr1 : PNP output transistor
Tr1, Tr2 : PNP output transistor Tr2 : NPN input transistor

Terminal arrangement diagram Terminal Designation


1
2
1 +V
Standard type: Comparative output 2
2
3 4 Multi-function type: Analog output or External input
3 0V
4 Comparative output 1
Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2
13

PRECAUTIONS FOR PROPER USE

• Never use this product as a sensing device for • The MS-DP1-4 panel mounting bracket is available when
personnel protection. switching from the DP2 / DP3 series.
• In case of using sensing devices for personnel DP2 / DP3
protection, use products which meet laws and standards,
DP
2-2
0

ñ10
1.3k
Pa

Front protective cover


such as OSHA, ANSI or IEC etc., for personnel
OUT

Remove
1

OUT
0-AD 2

DPX-04 (optional)
J
MO
DE

protection applicable in each region or country. can be installed on


MS-DP1-4.
• The DP-100 series is designed for use with non-corrosive
gas. It cannot be used with liquid or corrosive gas. Remove

Part description Insert


DP-100
Mounting holes
Main display for DP2 / DP3 series
can be used as is.
Comparative output 1 operation indicator
Sub display
Comparative output 2 operation indicator Panel mounting bracket MS-DP1-4
Work as analog voltage output operation
indicator in Multi-function type

Mode selection Decrement • An conversion bushing is available for when using the DP-10□-M
key key short pressure port type. It can be used to switch between this
Increment model and the DP2 / DP3 series. When connecting to the
key
pressure port, use a M5 female thread Rc 1 8 female thread
Wiring tightening torque of
• Make sure that the power supply is off while wiring. 1.0 N·m or less.
• Verify that the supply voltage variation is within the rating.
• If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power
supply is connected to an actual ground. Conversion bushing MS-DP1-7

• In case noise generating equipment (switching regulator, • The MS-DP1-F□ flat attachment is available for when using the DP-10□-M
inverter motor, etc.) is used in the vicinity of this sensor, short pressure port type. If using the MS-DP1-F□ flat attachment (optional),
connect the frame ground (F.G.) terminal of the equipment install by following the procedures given below.
to an actual ground. 1 Decide the direction of this product to mount with the sensor.

• Do not run the wires together with high-voltage lines or


power lines or put them in the same raceway. This can
cause malfunction due to induction.
• Incorrect wiring will cause problems with operation.

Connection Pressure port Pressure port Pressure port


faces leftward faces rightward
• Do not apply stress directly to Connector
faces downward
the connection cable leader or attached cable Note: It is not possible to mount this product such
to the connector. [CN-14A(-R)-C□] that the pressure port faces upward.

Mounting
Pressure port
• MS-DP1-1 / MS-DP1-5 sensor mounting brackets are faces upward
available separately, and it should be used for mounting. 2 Mount this product with the M3 female threads of the
When tightening the sensor to the sensor mounting bracket, sensor by using the attached M3 (length 8 mm 0.315 in)
use a tightening torque of 0.5 N·m or less. screws. The tightening torque should be 0.5 N·m or less.
M3 (length 6 mm 0.236 in) M3 female thread
screws with washers

(Accessory for MS-DP1-1


and MS-DP1-5 ) M3 (length 8 mm 0.315 in)
screw (Accessory)

Sensor mounting bracket M3 female thread


MS-DP1-1 (Optional)

3 Mount this product with the mounting surface by using


the attached M4 (length 20 mm 0.787 in) screws. The
• The MS-DP1-2 panel mounting bracket (optional) and the tightening torque should be 1.2 N·m or less.
MS-DP1-3 front protection cover (optional) are also
available.
Groove

Front protection cover


MS-DP1-3 (optional) Connector attached cable
M4 (length 20 mm 0.787 in)
screw (Accessory)
Note: Take care that if the cable with connector is sticking out of the side
groove of this product when mounting, the cable may disconnected.
Panel mounting bracket
MS-DP1-2 (optional)
14 Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2

PRECAUTIONS FOR PROPER USE

Conditions in use for CE conformity Flat attachment


• The DP-100 series is a CE conformity product complying • Make sure to mount MS-DP1-F□ with the sensor properly.
with EMC Directive. The harmonized standard with regard to If it is not mounted properly, air leakage may occur.
immunity that applies to this product is EN 61000-6-2 and the • Take care that the excessive mounting and dismounting of
following condition must be met to conform to that standard. this product may cause deterioration of the O-ring.
Condition • If you touch the O-ring of MS-DP1-F□, or any scratch or
dust, etc. is attached to it, air leakage may occur and the
• The line to connect with this sensor should be less than sensing performance may deteriorate.
30 m 98.425 ft. Take sufficient care when using and storing MS-DP1-F□.

Piping Others
• If connecting a commercially-available 12 mm 0.472 in
spanner
• Use within the rated pressure range.
coupling to the pressure port, attach a • Do not apply pressure exceeding the pressure withstandability
12 mm 0.472 in spanner (14 mm value. The diaphragm will get damaged and correct operation
0.551 in spanner for DP-100-E type) shall not be maintained.
to the hexagonal section of the • Do not use during the initial transient time (0.5 sec. approx.)
after the power supply is switched on.
pressure port to secure it, and tighten
• Avoid dust, dirt, and steam.
at a torque of 9.8 N·m or less. If it is
• Take care that the sensor does not come in direct contact with
tightened using excessive torque, it may
water, oil, grease, or organic solvents, such as, thinner, etc.
damage the coupling or the pressure port. • Do not insert wires, etc., into the pressure port. The
In addition, wrap sealing tape around the coupling when diaphragm will get damaged and correct operation shall not
connecting it to prevent leaks. be maintained.
• If connecting a commercially-available joint to the • Do not operate the keys with pointed or sharp objects.
pressure port of the DP-10□-M(-P), hold the main unit in
your hand to steady it, and tighten to a torque of 1.0 N·m RUN mode
or less. If it is tightened to an excessive torque, the joint or • This is the normal operating mode.
the main unit may become damaged.
• If connecting a commercially-available joint to the Setting item Description
pressure port of the MS-DP1-7, tighten to a torque of 9.8 The threshold values for ON/OFF operation can be
Threshold value changed directly by pressing the increment key
N ·m or less. 14 mm 0.551 in setting (UP) and the decrement key (DOWN).
spanner
Zero-adjustment This forces the pressure value display to be reset to zero when
function the pressure port is open on the atmospheric pressure side.
Key lock function Stops key operations from being accepted.
Displays the peak value and bottom value for fluctuating
Peak hold /
pressure. The peak value appears in the main display,
bottom hold function
and the bottom value appears in the sub display.

• The tightening torque should be 1 N·m or less when


MENU SETTING mode
connecting a coupling to the pressure port of MS-DP1-FM.
• If the mode selection key is pressed and held for 2
seconds in RUN mode, the mode will switch to MENU
SETTING mode.
• If the mode selection key is pressed while a setting is
being made, the mode will switch to RUN mode. In this
case, the settings that have been changed will be entered.
Setting item Description
Pressure port
Coupling (Purchase separately.) Comparative output 1
Sets the output mode for comparative output 1.
output mode setting

Comparative output 2 output mode


Sets the output mode for comparative output 2.
setting (standard type only)
• When connecting the coupling to the pressure port of
MS-DP1-FR/FE/FN, hold the pressure port with a 14 mm Analog output / external Allows switching between analog voltage output /
0.551 in spanner and make sure that the tightening torque input switching analog current output, and auto-reference input /
(multi-function type only) remote zero-adjust-ment input.
is 9.8 N·m or less.
In addition, in order to prevent any leakage, wind a sealing NO/NC switching Sets normally open (NO) or normally closed (NC).
tape on the coupling when connecting. Sets the response time.
The response time can be selected from 2.5 ms,
Response time setting
5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms,
500 ms, 1,000 ms and 5,000 ms.

Allows the color for the main display to be changed.


Display color switching The colors can be set to ‘red / green’ or ‘green / red’
for main display to correspond to ON/OFF output, or it can be fixed
at ‘red’ or ‘green’ all the time.
14 mm 0.551 in
spanner
Unit switching Pressure unit can be changed.

Note: Do not tighten the pressure port by holding the product with the
spanner. It may cause the product breakage.
Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2
15

PRECAUTIONS FOR PROPER USE

PRO mode Table of codes


• If the mode selection key is pressed and held for 5
seconds in RUN mode, the mode will switch to PRO 2nd digit 4th digit
1st digit Multi-function 3rd digit Standard
mode.

Code
Standard type type type only
• If the mode selection key is pressed while a setting is Comparative output 1 NO/NC
output mode
Comparative output 2 NO/NC Analog voltage output / Threshold Display color for Display
switching output mode switching External input value display main display color linking
being made, the mode will switch to RUN mode. In this
Analog voltage Comparative
case, the settings that have been changed will be entered. NO OFF OFF
output
P-1, Lo-1 Red
output 1
EASY when ON
Auto- Comparative
Setting item Description NC NO reference Hi-1 output 2
Changes the information in the sub display EASY
Remote Comparative
NO NC
Sub display switching during RUN mode operation to the desired zero-adjustment P-2, Lo-2 Green output 1
alphanumeric display. Hysteresis
Analog current when ON Comparative
NC NO Hi-2
Display refresh rate Changes the display refresh rate for the output output 2
switching pressure value displayed in the main display. Hysteresis
— Comparative
NO NC ADJ.
Window Always output 1
Hysteresis fix value Sets the hysteresis for EASY mode and window comparator red Comparative
switching comparator mode. (8 steps) NC NO — —
Window output 2
Linked display color Allows the display color for the main display to comparator Comparative
switching be switched in line with the output operation for — — NC — —
Always output 1
(standard type only) comparative output 1 or comparative output 2. green Comparative
— — — — — —
Allows power consumption to be reduced by output 2
ECO mode setting
dimming the display or turning it off.

Allows the setting details to be checked via


Setting check code
codes.

Allows the setting details for the master sensor


Setting copy mode
to be copied to slave sensors.
Reset setting Resets the settings to the factory settings.

5th digit 6th digit 7th digit 8th digit


Code

Response time Unit switching Display refresh rate ECO mode


2.5 ms MPa 250 ms OFF
5 ms kPa 500 ms STD
10 ms kgf/cm2 1,000 ms FULL
25 ms bar — —
50 ms psi — —
100 ms mmHg — —
250 ms inchHg — —
500 ms — — —
1,000 ms — — —
5,000 ms — — —

DIMENSIONS (Unit: mm in) The CAD data can be downloaded from the website.

DP-10□(-P) Sensor
42.5
30 1.673 20 Europe
25.5 7.5 9.5 Connector 10 7
1.181 1.004 0.295 0.374 0.787
0.394 0.276

30 20 12 14
1.181 0.472 0.551
0.787
G 1/ 8
R (PT) 1/ 8 male thread
male thread
1.5 (North America: NPT 1/ 8) M5 female thread
0.059 M3 female thread, 4 0.157 deep

DP-10□-M(-P) Sensor
30
30 1.181 20
25.5 4.5 0.787
1.181 1.004 0.177

30 ø8.3 20
1.181 ø0.327 0.787 connector

1.5 M3 female thread, M5 female thread,


0.059 4 0.157 deep 4 0.157 deep

DP-11□-E-P-J Sensor
47.5
20
30 25.5 1.870 7 0.787
1.181 1.004 0.276 M8 connector

9.5
30 0.374 20
1.181 0.787 14
0.551
4.5 0.177
1.5 15 G 1/8 male thread M5 female thread
0.059 0.591 7 0.276 M3 female thread,
4 0.157 deep
16 Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2

DIMENSIONS (Unit: mm in) The CAD data can be downloaded from the website.

MS-DP1-1 Sensor mounting bracket (Optional)

ø2.3 Assembly dimensions


ø0.091
Mounting drawing with DP-10□(-P)
22 2-R2.1 R0.083
14.5 9.5 0.866 9.5
0.571 0.374 1 0.374
0.039
4.2 2-R2.1 R0.083 14.5
0.165 22 0.571
0.866 4.2
30 0.165 25.5
2-ø3.5 ø0.138 1.004
1.181 42.5
20 1.673
0.787
13
0.512 7.5 9.5
0.295 0.374
20 R13
0.787 R0.512 (0.209
5.3
) 44
45
1.772 30 12
5.5 1.732 1.181 45 0.472
t2 0.217
t 0.079 20 1.772 30
0.787 1.181
15
0.591 1.5
0.059
Material: Cold rolled carbon steel (SPCC) 30 t2
(Trivalent uni-chrome plated) 1.181 t 0.079
Two M3 (length 6 mm 0.236 in) screws with washers are attached.

MS-DP1-5 Sensor mounting bracket (Optional)


Assembly dimensions
Mounting drawing with DP-10□-M(-P)
R6.75
22.75 R0.266
0.896

29.5 ø4.5
1.161 16
ø0.177 0.630
20 28
4.5 0.787 8.5 1.102
0.177 0.335
30
1.181
44.5 4.5
0.177
30 1.752
20 1.181
0.787 (1.949
49.5
) ø8.3
ø0.327
t 1.5 20 49.5
13.5 2-ø3.5 ø0.138 t 0.059 0.787 28.5 1.949
0.531 1.122
20 1.5
0.787 ø4.5 0.059
ø0.177 20 4.5 28 t 1.5
Material: Stainless steel (SUS304) 0.787 0.177 1.102 t 0.059
29.5 53.5
Two M3 (length 6 mm 0.236 in) screws with washers are attached. 2.106
1.161
30
1.181

MS-DP1-2 MS-DP1-3 Panel mounting bracket (Optional), Front protection cover (Optional)
Assembly dimensions
Mounting drawing with DP-10□(-P) Panel cut-out dimensions
When 1 unit is installed
0
31−0.4
0
1.220 −0.016
0
31−0.4
0
(Note 2) 1.220 −0.016
7.2 18.3 7.5 9.5
( 1.547
39.3
) 0.283
11
0.720 0.295 0.374
34.5 0.433 When “n” units are installed horizontally in series When “n” units are installed vertically in series
1.358 0
31−0.4
0
Front 31 1.220 Xn + 3.5 0.138 X (n-1) 1.220 −0.016

(
34.5 20
1.358 0.787 ) protection
cover
12 (Note 2)
0.472 0
0
31−0.4
1.220 −0.016
R 1/ 8 55 2.165 31 1.220 Xn + 3.5 0.138 X (n-1)
50 male thread (Note 1) or more
1.969 8.7
33.4 0.343 Panel thickness dimension
1.315 1 to 6 mm 0.039 to 0.236 in

33.4 Connector 55 2.165


1.315 M5 female thread, or more
4 0.157 deep Note: The panel thickness should be Note: The panel thickness should be
1 to 6 mm 0.039 to 0.236 in. 1 to 6 mm 0.039 to 0.236 in.
M3 female thread,
(52 2.047 max) 4 0.157 deep
View A
Material: Polyacetal (Panel mounting bracket)
Polycarbonate (Front protection cover)

Notes: 1) DP-10□-E-P has a G1/8 male thread. DP-10□-N (-P)has a NPT1/8 male thread.
2) In case of DP-10□-E-P, the dimension 7.5 become to be 10, the dimension 9.5 become to be 7 and the dimension 12 become to be 14.
Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2
17

DIMENSIONS (Unit: mm in) The CAD data can be downloaded from the website.

MS-DP1-4 Panel mounting bracket (Replacement from conventional model) (Optional)


Assembly dimensions
Mounting drawing with DP-10□(-P) Panel cut-out dimensions
36
(1.681
42.7
) 1.417
40
1.575
(0.3829.7) 26.5
1.043 R 1/ 8
56
2.205
6.5 0.256 male thread
30 (Note 1)
1.181 3 0.118 36 +0.5
0
1.417+0.020
0
Connector
40 30 42.7 12
0.472 M5 female 36 +0.5
1.575 1.181 1.681 thread
0

Panel mounting 80 1.417+0.020


0

bracket body 3.150


Spacer
Front protection cover
(DPX-04) 8
0.315 Panel mounting
Panel thickness dimension 1 to 3.2 mm bracket
0.039 to 0.126 in

Material: Nylon 6 (Panel mounting bracket body)


Stainless steel (SUS304) (Panel mounting bracket)
Cold rolled carbon steel (SPCC) (Trivalent uni-chrome plated) (Spacer)
Notes: 1) DP-10□-E-P has a G1/8 male thread. DP-10□-N (-P)has a NPT1/8 male thread.
2) The panel tickness should be 1 to 32 mm 0.039 to 1.260 in.

MS-DP1-FM Flat attachment (Optional) MS-DP1-FR/FN/FE Flat attachment (Optional)

Assembly dimensions Assembly dimensions


Mounting drawing with DP-10□-M(-P) Mounting drawing with DP-10□-M(-P)

(1.752
44.5
) 37
1.457 ( 2.067
52.5
) 37
(0.945
24
) 11.5
0.453 (0.945
24
) 1.457
11.5
0.453

30 11
30 11 1.181 0.433
1.181 0.433 52.5 24
44.5 24 2.067 0.945
1.752 0.945 6.5 0.256
6.5 0.256 5.5 0.217 13.5
5.5 0.217 0.531

2-ø4.3 ø0.169 20 2-ø4.3 14


0.787 ø0.169 0.551 Product distinguishing mark 8.5
24 17.5 20 0.335
0.689 0.787 MS-DP1-FR: 0 line 17.5
0.945 24 0.689
MS-DP1-FN: 1 line
30 Material: Polybutylene terephthalate (PBT) 0.945
30 MS-DP1-FE: 2 line
1.181 (Glass fiber reinforced) (Enclosure) 1.181
M5 female thread Stainless steel (SUS303) (Pressure port) Pressure port Material: Polybutylene terephthalate (PBT)
Hydrogenated Nitrile Butadiene Rubber G1/8 female thread (Note) (Glass fiber reinforced) (Enclosure)
(H-NBR) (O-ring) Stainless steel (SUS303) (Pressure port)
Weight: 15 g approx. (flat attachment only) Hydrogenated Nitrile Butadiene Rubber (H-NBR)
(O-ring)
Two M3 (length 8 mm 0.315 in) screws,
8.5 0.335 two M4 (length 20 mm 0.787 in) screws Weight: 25 g approx. (flat attachment only)
are attached. Two M3 (length 8 mm 0.315 in) screws, two M4
(length 20 mm 0.787 in) screws are attached.

Note: MS-DP1-FR has a Rc1/8 female thread.


MS-DP1-FN has a NPT1/8 female thread.

MS-DP1-7 Conversion bushing (Optional) CN-14A(-R)-C□ Connector attached cable (Optional, CN-14A-C2 is attached to the sensor)
15.8
0.622 L

(1.378
35
) (1.969
50
)
( )8
0.315 (0.3158 )
14
0.551
3.5 7.8 ø3.7 ø0.146 cable
0.138 0.307 M5 male thread

( 0.5
0.020 ) Gasket
• Length L

11 0.433 10 0.394 8 Model No. Length L (mm in)


0.315
CN-14A(-R)-C1 1,000 39.370
Rc1/8 female thread
CN-14A(-R)-C2 2,000 78.740

Material: Brass (Nickel plated) CN-14A(-R)-C3 3,000 118.110


Weight: 10 g approx.
CN-14A(-R)-C5 5,000 196.850
Disclaimer
The applications described in the catalog are all intended for examples only. The purchase of our products described in the catalog shall not be
regarded as granting of a license to use our products in the described applications. We do NOT warrant that we have obtained some
intellectual properties, such as patent rights, with respect to such applications, or that the described applications may not infringe any
intellectual property rights, such as patent rights, of a third party.

Panasonic Industry Co., Ltd.


Industrial Device Business Division
7-1-1, Morofuku, Daito-shi, Osaka 574-0044, Japan
industrial.panasonic.com/ac/e/

Specifications are subject to change without notice.


ⓒ Panasonic Industry Co., Ltd. 2022.8
Printed in Japan