You are on page 1of 23

Implimentation Survey Report

Site ID: HAW2359 Tower Height= 36 m Tower Type GF


Buidling Height: 0 Sharing Operator: NA Host : NA

Sharing information:
Mobily STC
Sharing Operator Antenna: NA NA
Sharing Operator RRU: NA NA
Sharing Operator MW: NA NA
Before Implementation:
Existing MW Antenna: 1
0.6m( 4+0 )NEC
Total GSM Antennas: 3
RRU Quantity: 4
4 *BOX(2*FXDB+2*FXEB+1*ARMA+1*FRGT+1*FRGU)
Ant. Type1: RV4-65D-R5-V6
for G900/U2100/L800/L1800/L2100
Ant. Qty: 3
Ant. Dim: L2.688 X W 0.35 X D 0.208

Ant. Type2:
for
Ant. Qty:
Ant. Dim:

Total MW Antenna: 1
0.6m( 4+0 )NEC

After Implementation:
Total GSM Antennas: 6
RRU Quantity: 4
4 *BOX(2*FXDB+2*FXEB+1*ARMA+1*FRGT+1*FRGU)

Ant. Type: RV4-65D-R5-V6


for G900/U2100/L800/L1800/L2100
Ant. Qty: 3
Ant. Dim: L2.688 X W 0.35 X D 0.208

Ant. Type2:
for
Ant. Qty:
Ant. Dim:
New RRU Qty:

Add New Ant: AEHC


for NR2600
New Ant Qty: 3
New Ant. Dim: L.0.97 X W 0.545 X D 0.205

Total MW Antenna: 1
(1*0.3) NOKIA
Sector A:
Add New Antenna
Keep Existing both SEC A Ant's (RV4-65D-R5-V6 For
G900/U2100/L800/L1800/L2100 ) And
need Instal new ANT AEHC at sec A

Azimuth : 35 Height: 35

Mount Proposal : NO
Mount Quantity : NA

need Instal new ANT AEHC at sec A at existing pole

Feeder/CPRI/Power Cable Length : 45 m

Azimuth : 35 Height: 35

Scenario Introduce NR 3500 MHz


Antennas must be installed As per SAF Azimuth
New CPRI will be installed instead of dismantled ones
Blockage Proposal (If any) :

Sector B:
Add New Antenna
Keep Existing both SEC B Ant's (RV4-65D-R5-V6 For
G900/U2100/L800/L1800/L2100 ) And
need Instal new ANT AEHC at sec B

Azimuth : 170 Height: 35

Mount Proposal : NO
Mount Quantity : NA

need Instal new ANT AEHC at sec B AT EXISTING POLE

Feeder/CPRI/Power Cable Length : 45 m

Azimuth : 170 Height: 35

Scenario Introduce NR 2600 MHz


Antennas must be installed As per SAF Azimuth
New CPRI will be installed instead of dismantled ones

Sector C:
Add New Antenna
Keep Existing both SEC C Ant's (RV4-65D-R5-V6 For
G900/U2100/L800/L1800/L2100 G119
NEED SHIFT RRU and install ANT SEC C AEHC at existing pole

Azimuth : 240 Height: 35

Mount Proposal : NO
Mount Quantity : NA

NEED SHIFT RRU and install ANT SEC C AEHC at existing pole

Feeder/CPRI/Power Cable Length : 45 m

Azimuth : 240 Height: 35

Scenario Introduce NR 2600 MHz


Antennas must be installed As per SAF Azimuth
New CPRI will be installed instead of dismantled ones
Blockage Proposal (If any) :
MW Outdoor Action After Implemtation
Add New Antenna
DISMANTLE 0.6 /4+0 NEC Link HWA2359-HAW0304
Reqired new mount 2m to install New 0.3 link NOKIA ( Azm
92.18 / HT 19m ) HWA2359-HAW0304
Hei
Azimuth : 92.18 19
ght:
Mount Proposal : YES
Mount Quantity : 1
new mount 2m to install New 0.3/2+0 link NOKIA

CPRI/Power Cable Length: 45 m

Blockage Proposal (If any) :


Existing Cabinet/Rack:

BBU/Cards Solution:

Reuse existing AMIA (1*ASIB+1*ABIO+2*ABIA) and dismantle


(1*ASIA)

MW Indoor Action After Implemtation

dismantle NEC IPASSO 400 and need new MSS8 FOR NEW LINK
Existing DCDU:

NA
Existing DCDU

DCDU Proposal :

NA
* Need to INSTALL 4 new CB …....................... 2*16A for MSS8 and
2*100A for new FPFH for new 3*AEHC

Existing Circuit Breaker (CB):

Existing Circuit Breaker (CB)

DC Calculation :

DC Load = 79 A DC Display Missing

ELTEK Rectifier- 2000 W

8 Rectifier Modules Available

4 Slots free for Rectifier Module

Rectifier Module need to add

Rectifier Swap Scenraio :

Remakrs:

Battery :

NA
• BATTERY TYPE:

NA
• Batteries Qty:
NA
• Capacity:

New Battery Space Available :

•New BATTERY TYPE:


Under Nokia
• New Batteries Qty:

• Capacity:

Remarks: ________________

DC cable size for battery Available :

Add Details 4*10mm


Add Picture and mark location

Roxtec / Free Entrnace :

• Space Available:

GPS :

NA
Existing GPS
SCECO Breaker Information :

EXISTING SCECO BRAEKER

CAPACITY: NA A

SCECO Meter Information :

EXISTING SCECO Meter #

NA

Meter CAPACITY: NA A

Transformer Information :

Transformer CAPACITY: KVA


NA

Generator Information :

Generator CAPACITY: KVA


Not available

Generator Brand:

Existing ZAIN Breaker

CAPACITY: 100 A NA

Site Phases Information :

SCECO VOLTAGE PH to PH
VOLTAGE: 380 V

EXISTING PHASE-01

Current: 9.8 A
EXISTING PHASE-02

Current: 9.9 A

EXISTING PHASE-03

Current: 5.2 A

Tenant Phases Information (incase sharing load):

EXISTING PHASE-01

NA
Current: A

EXISTING PHASE-02

NA
Current: A

EXISTING PHASE-03

NA
Current: A
AC cable size Information :

MDB to Rectifier 4*16mm mm2

Need Pic For Cable Size

AC cable size Information :

Generator to shelter mm2


Need Pic For Cable Size

AC cable size Information :

NA

SCECO Breaker/MCCB to Shelter mm2

ODC/shelter Aircon-1 Information :

Aircon-1 status: ___ NOT WORKING

Add clear Picture of Aircon & specification Plate


Airocn Capacity:_______________________ BTU

ODC/shelter Aircon-2 Information :

Airco-2 status: ___________________________

Add clear Picture of Aircon & specification Plate


Airocn Capacity:_______________________ BTU

EXISTING SITE TEMPERATURE


NA
TEMPERATURE: NA C
Site Info.

SM istalled
Site Final Need Access Shelter In(BTS/Rect
Site ID Need crane Project SCOPE
Type Access contact /ODU fier
cabinate )

Rectfier
Sophia
HAW2359 GF-36m NA NA NA ODU cabinet & 2.6 NR Introduce + MW Link
Phase 4
BTS
Nokia NEC

CIVIL FB Power FB TX FB 0.3 0.6 1.2 1.8 0.3 0.6 0.8

na na NA 0 0 0 0 0 1 0
EXISTING TI&TX DATA
NEC

0.9 1.2 1.8 2.5 3.5 900 Band ANT Type 3G Band ANT Type

0 0 0 0 0 3*10PORT 3 * RV4-65D-R5-V6 share share


Antenna data

1800 Power
Band/LTE ANT Type AEHC ANT Type C-BAND ANT Type wifi GPS Ant F/FL cable
Band/2100 length

share share 0 0 NA NA NA 0 FL 45
Nokia NEC

fiber cable 0.6 0.9


# OF RRU/BOX 0.3 0.6 1.2 1.8 0.3
length

4
*BOX(2*FXDB+2*FXEB
45 1 0 0 0 0 0 0
+1*ARMA+1*FRGT+1*F
RGU)
Nokia _Planed TL Data
NEC Antena Data

1800
1.2 1.8 900 Band
ANT Type 2G Band ANT Type Band/LTE ANT Type AEHC
LTE 800
Band/2100

0 0 3*10PORT 3 * RV4-65D-R5-V6 share share share share 3


Antena Data

New SM
ANT Type C BAND ANT Type wifi GPS NEW RRU Action on tower
Location

4
3*AEHC 0 0 NA 0 NA *BOX(2*FXDB+2*FXEB+1*AR
MA+1*FRGT+1*FRGU)
Site Inforamation

Site ID Region Project Scope

HAW2359 West Sophia Phase 4 2.6 NR INTRODUCE+ MW link


foramation AC Information
Cabinet
Type Meter SCECO
Tech Site Type( Power Type
(Shelter/ Owner Capacity
ODC)
2.6 NR INTRODUCE+ MW link GF ODC SCECO NA NA
AC Information DC Information
Voltage
Transfor DG Rectifier Max No
3-Phase Rectifier Module
mer Capacity Module Free Slots Of Battery Type
(220V/38 Type Capacity
(KVA) (KVA) QtY Modules
0V)
380 NA NA ELTEK 8 4 4 2000 NA
DC Information Proposed
Dismantli
DC
Battery New Load ng DC Total
No of Battery cell DC Load (A) Consider
capacity max (A) Equipmen Load (A)
Load
t
NA NA 79A #VALUE!
AHP4518R5v06
ASI4518R42v06
ASI4518R10v06
AOC4518R3v06
APE4517R0
ASI4518R10v18
AAU5614
AAU5613
AAU5639w (2.6G)
AAU5639w (3.5G)
A19451902
A704521R0
ASI4518R10
ATR451704v01
AOC4518R8v06
APE4517R0v06
ATR4518R11
AAU3911
A264518R0v01
ATR451714
ADU4518R8v06
ASI4517R3v06
AQU4518R25
AOC4518R0v06
A79451700V02
ADU451801
742236v01
742 266
ADU4518R8
A19451811
APE4516R1v06
ATR4518R14
ADU4518R0v06
A704517R0
ADU4517R6v06
80010305V02
A704517R0v06
ADU451807v01
LBX-3319DS-TOM
ADU4521R0v06
ADU451712v06
K739624
K742213v01
A90451800
ATR451704
TDJ-809018DME-65P
HBX-6517DS-VTM
ATR4518R4
AAU5636
ADU451902v06
TBXLHA-6565C-VTM
K80010204
A19451811v06
DBXLH-6565A-VTM
K742224
K739623
LBX-3319DS-T0M
K80010302
ADU4517R2
A794517R0
RRU5309 (L800)
RRU5509t (G900/L800)
RRU3936
RRU3953
RRU5904 (L1800)
RRU5904 (L2100)
RRU5904 (L1800/L2100)
RRU5513 (L1800/L2100)
RRU5909N (L1800)
RRU5909 (L2100)
RRU5309 + RRU5909N (L800/L1800)
RRU5309 + RRU5909 (L800/L2100)
RRU5909N + RRU5909 (L1800/L2100)
RRU5309 + RRU5904 (L800/L2100)
RRU5509t (G900/L800) & RRU5513(L1800/L2100)
RRU5509t (G900/L800) & RRU5909 (L2100)
RRU5309 (L800) + RRU5513 (L1800/L2100)
A704521R0v06
AAU5636m
AAU5636w

You might also like