You are on page 1of 28

Polyethylene Moulded Cable Pits

PLASTIC PITS

Polyethylene moulded pits are lightweight,


easy to cut and feature a ribbed
construction for strength and durability.
Recommended for light duty applications,
they are robust, cost-effective and
versatile.

Features

U Polyethylene recyclable plastic


contains no toxic heavy metals – safe
for the environment
U Ideal for use in light duty installations
U Lightweight, easy to handle & cut for
cable entry penetration
FEA designed continuous ribs for the
U UV stable
efficient transfer of loads.
U Range of anti-slip lids and access
covers
U OH&S friendly steel lids not exceeding
25kg
U IP ratings up to IP4X (AS 60529) -
enclosure protection against ingress
U Aesthetic, recessed access covers
allowing for the infill of pavement
material to complement or match the
surrounding pavement
U Steel lids and access covers are hot
dip galvanised to AS 4680
U Access covers are weather resistant

Versatile pit walls contain cutoffs to alter


the depth of the pit.

Key
These icons appear on the following
product pages to easily identify the lid and
cover options available with each pit/riser.

Plastic pit with lid

Plastic pit with riser and lid

Plastic pit with access cover

Plastic pit with riser and


access cover Fastening provisions for the quick fitting
of locking brackets for the PowerLok® lid
system.

44
ACO CABLEMATE

Applications

s ,ANDSCAPED AREAS

s 3TREETSCAPES

s 3PORTS VENUES

s 2ESIDENTIAL APPLICATIONS

s -EDIAN STRIPS

45

www.acoaus.com.au/cablemate
Product Selection Steps
,ENGTH MM L W Once pit type is determined:
Type 1 Pit 7IDTH MM D 5P TO
1. Determine if riser is required.
$EPTH MM MM  RISER
2. Select lid or access cover (adds
additional depth) to suit project
application.

Lids

Steel lid (AS 3996 Class B).


Slip Resistance Rating R10 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.
If a locking lid is required, contact ACO.

Cement concrete lid (AS 3996 Class A).


Slip Resistance Rating R9 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.
PLASTIC

Riser

Optional riser to increase pit depth, riser rebate


is identical to pit rebate and with lid, offers
the same IP protection. To produce riser, cut Note: Access covers fit above pit/riser, refer to
base off another pit to appropriate length. ACO pg 80 for installation guidelines.
recommends no more than 1 riser. Riser adds
200mm depth.

Lids fit into rebate at top of pit, whilst access


covers must be installed in a cast in situ
concrete collar.

Pit

Continuous ribbed wall design for maximum wall


strength. All plastic pits have undergone FEA
analysis to ensure optimum pit performance.

Pit can be cut at specific points to create a


shallower pit.

Use holesaw to cut conduit hole anywhere Plastic pit construction offers an economic pit
on side wall. The maximum number of holes solution for light duty applications. Plastic also
recommended per pit is limited by conduit offers excellent electrical resistivity.
quantity and size. Contact ACO for guidance.

46
ACO CABLEMATE®

Weather Resistant
Access Covers
All access covers have IP4X (AS 60529)
protection against ingress of foreign
objects. Rhinocast® access covers offer
water & gas tightness to AS 3996.
Ductile iron Rhinocast®
solid top cover (AS 3996
Class B)
AS/NZS 4586 Slip
Resistance Rating R10

Ductile iron
®
Rhinocast®
Steel Urbanfil recessed
recessed cover
cover (AS 3996 Class B)
(AS 3996 Class B)

Steel Pavermate®
recessed cover (AS 3996
Class B)

Cast-in-situ
Cast-in-situ concrete collar
Iron frame - external dim.
concrete collar Steel frame - external dim. 600 x 560 x 55mm
580 x 330 x 70mm

W
L

X D
Y

Z C

Type 1 Pit Parts List4 A Green area indicates


B internal working area
Description Part No. Weight (kg)
Pit Dimensions
Type 1 plastic pit 75858 3
Internal working area (mm)
Lids & Covers Cover1 Total
A 350
Cement concrete lid (AS 3996 Class A) - Blank 75860 7 7
B 140
Cement concrete lid (AS 3996 Class A) - Communications 75861 7 7
C 160
Cement concrete lid (AS 3996 Class A) - Electricity 75862 7 7
X 430
Steel lid (AS 3996 Class B) 70120 3 3
Y 150
Steel Urbanfil® recessed cover (AS 3996 Class B) 2 80150 8 13
Z 355
Steel Pavermate® recessed cover (AS 3996 Class B) 2 80151 8 13
Overall dimensions (mm)
Ductile iron Rhinocast® recessed cover (AS 3996 Class B) 3 85014 28 40
L 520
Ductile iron Rhinocast® solid top cover (AS 3996 Class B) 3 85249 20 44
W 240
Notes:
D 400
1. Lid & access cover weights are provided as lifting weight (individual cover parts) and total weight.
Recessed covers weight do not include pavement infill; for approx. lifting weight - Urbanfil®/ Notes:
Pavermate® covers - multiply weight by ‘7’; Rhinocast® covers multiply weight by ‘1.5’. 1. Using risers will increase pit depth (Z & D) by
2. Optional brass edging (Specify ‘BE’ after part number). depth of riser.
3. Optional locking, brass or stainless steel edging in 12mm or 40mm heights (Specify ‘BE’ or ‘SS’ and 2. Access covers will increase depth of pit by
height after part number). height of concrete collar - allowance should be
4. For Accessories (e.g. identification plates, divider brackets, cable hanger brackets see pg 43). made for concrete collar during pit installation.
See pg 82 for excavation details. 47

www.acoaus.com.au/cablemate
Product Selection Steps
,ENGTH MM L W Once pit type is determined:
Type 2 Pit 7IDTH MM D 5P TO
1. Determine if riser is required.
$EPTH MM MM  RISER
2. Select lid or access cover (adds
additional depth) to suit project
application.

Lids

Steel lid (AS 3996 Class B).


Slip Resistance Rating R10 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.
If a locking lid is required, contact ACO.

Cement concrete lid (AS 3996 Class A).


Slip Resistance Rating R9 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
PLASTIC

foreign objects if fitted with universal plug.

Riser

Optional riser to increase pit depth, riser rebate


is identical to pit rebate and with lid, offers Note: Access covers fit above pit/riser, refer to
the same IP protection. To produce riser, cut pg 80 for installation guidelines.
base off another pit to appropriate length. ACO
recommends no more than 1 riser. Riser adds
200mm depth.

Lids fit into rebate at top of pit, whilst access


covers must be installed in a cast in situ
concrete collar.

Pit

Continuous ribbed wall design for maximum wall


strength. All plastic pits have undergone FEA
analysis to ensure optimum pit performance.

Pit can be cut at specific points to create a


shallower pit.

Plastic pit construction offers an economic pit


solution for light duty applications. Plastic also
Use holesaw to cut conduit hole anywhere offers excellent electrical resistivity.
on side wall. The maximum number of holes
recommended per pit is limited by conduit
quantity and size. Contact ACO for guidance.

48
ACO CABLEMATE®

Weather Resistant
Access Covers
All access covers have IP4X (AS 60529)
protection against ingress of foreign
objects. Rhinocast® access covers offer
water & gas tightness to AS 3996.

Ductile iron Rhinocast®


solid top cover (AS 3996
Steel Urbanfil recessed
®
Class B)
cover (AS 3996 Class B)
AS/NZS 4586 Slip Resistance
Rating R10

Ductile iron Rhinocast®


Steel Pavermate® recessed cover
recessed cover (AS 3996 (AS 3996 Class B)
Class B)

Cast-in-situ Cast-in-situ Iron frame - external dim.


concrete collar concrete collar 750 x 560 x 55mm
Steel frame - external dim.
730 x 430 x 70mm

W
L

X D
Y

Z C

Type 2 Pit Parts List4 A Green area indicates


B internal working area
Description Part No. Weight (kg)
Pit Dimensions
Type 2 plastic pit 75946 6
Lids & Covers Cover1 Total Internal working area (mm)
A 430
Cement concrete lid (AS 3996 Class A) - Blank 75948 13 13
B 165
Cement concrete lid (AS 3996 Class A) - Communications 75949 13 13
C 325
Cement concrete lid (AS 3996 Class A) - Electricity 75950 13 13
X 570
Steel lid (AS 3996 Class B) 70220 6 6
Y 200
Steel Urbanfil® recessed cover (AS 3996 Class B) 2 81225 11 16
Z 520
Steel Pavermate® recessed cover (AS 3996 Class B) 2 81340 11 16
Overall dimensions (mm)
Ductile iron Rhinocast® recessed cover (AS 3996 Class B) 3 85037 28 49
L 660
Ductile iron Rhinocast® solid top cover (AS 3996 Class B) 3 85236 28 47
W 290
Notes:
D 575
1. Lid & access cover weights are provided as lifting weight (individual cover parts) and total weight.
Recessed covers weight do not include pavement infill; for approx. lifting weight - Urbanfil®/ Notes:
Pavermate® covers - multiply weight by ‘7’; Rhinocast® covers multiply weight by ‘1.5’. 1. Using risers will increase pit depth (Z & D) by
2. Optional brass edging (Specify ‘BE’ after part number). depth of riser.
3. Optional locking, brass or stainless steel edging in 12mm or 40mm heights (Specify ‘BE’ or ‘SS’ and 2. Access covers will increase depth of pit by
height after part number). height of concrete collar - allowance should be
4. For Accessories (e.g. identification plates, divider brackets, cable hanger brackets see pg 43). made for concrete collar during pit installation.
See pg 82 for excavation details. 49

www.acoaus.com.au/cablemate
Product Selection Steps
,ENGTH MM L W Once pit type is determined:
Type 3 Pit 7IDTH MM D 5P TO
1. Determine if riser is required.
$EPTH MM MM  RISER
2. Select lid or access cover (adds
additional depth) to suit project
application.

Lids

Steel PowerLok® lid (AS 3996 Class B).


Slip Resistance Rating R10 AS/NZS 4586.
IP2XD (AS 60529) protection against ingress of
foreign objects when hatch is closed.

Steel lid (AS 3996 Class B).


Slip Resistance Rating R10 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.

Cement concrete lid (AS 3996 Class A).


Slip Resistance Rating R9 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.
PLASTIC

Riser

Optional riser to increase pit depth, riser rebate


is identical to pit rebate and with lid, offers Note: Access covers fit above pit/riser, refer to
the same IP protection. To produce riser, cut pg 80 for installation guidelines.
base off another pit to appropriate length. ACO
recommends no more than 1 riser. Riser adds
300mm depth.

Lids fit into rebate at top of pit, whilst access


covers must be installed in a cast in situ
concrete collar.

Pit

Continuous ribbed wall design for maximum wall


strength. All plastic pits have undergone FEA
analysis to ensure optimum pit performance.

Pit can be cut at specific points to create a


shallower pit.

Use holesaw to cut conduit hole anywhere


on side wall. The maximum number of holes Plastic pit construction offers an economic pit
recommended per pit is limited by conduit solution for light duty applications. Plastic also
quantity and size. Contact ACO for guidance. offers excellent electrical resistivity.

50
ACO CABLEMATE®

Weather Resistant
Access Covers
All access covers have IP4X (AS 60529)
protection against ingress of foreign
objects. Rhinocast® access covers offer
water & gas tightness to AS 3996.

Ductile iron Rhinocast®


solid top cover (AS 3996
Class B)
AS/NZS 4586 Slip
Resistance Rating R10
Steel Urbanfil® recessed
cover (AS 3996 Class B)
Ductile iron Rhinocast®
recessed cover
(AS 3996 Class B)

Steel Pavermate®
recessed cover (AS 3996
Class B)

Iron frame - external dim.


600 x 560 x 55mm

Cast-in-situ
concrete collar
Cast-in-situ
concrete collar Steel frame - external dim.
730 x 430 x 70mm

W
L

X D
Y

Z C
Type 3 Pit Parts List6
A Green area indicates
Description Part No. Weight (kg) B internal working area
Type 3 plastic pit 75865 6
Pit Dimensions
Lids & Covers Cover1 Total
Internal working area (mm)
Cement concrete lid (AS 3996 Class A) - Blank 75881 13 13
A 435
Cement concrete lid (AS 3996 Class A) - Communications 75898 13 13
B 205
Cement concrete lid (AS 3996 Class A) - Electricity 75906 13 13
C 180
Steel lid (AS 3996 Class B) 70320 6 6
X 455
Steel PowerLok® lid (AS 3996 Class B) 2, 3 70330 9 9
Y 225
Steel Urbanfil® recessed cover (AS 3996 Class B) 4 81225 11 16
Z 475
Steel Pavermate® recessed cover (AS 3996 Class B) 4 81340 11 16
Overall dimensions (mm)
Ductile iron Rhinocast® recessed cover (AS 3996 Class B) 5 85014 28 40
L 565
Ductile iron Rhinocast® solid top cover (AS 3996 Class B) 5 85249 20 44
W 335
Notes:
D 530
1. Lid & access cover weights are provided as lifting weight (individual cover parts) and total weight.
Recessed covers weight do not include pavement infill; for approx. lifting weight - Urbanfil®/ Notes:
Pavermate® covers - multiply weight by 7’; Rhinocast® covers multiply weight by ‘1.5’. 1. Using risers will increase pit depth (Z & D) by
2. All lids are supplied with brackets and support bars where applicable. depth of riser.
3. PowerLok® lids supplied with locking bolt (padlock not supplied). 2. Access covers will increase depth of pit by
4. Optional brass edging (Specify ‘BE’ after part number). height of concrete collar - allowance should be
5. Optional locking, brass or stainless steel edging in 12mm or 40mm heights (Specify ‘BE’ or ‘SS’ and made for concrete collar during pit installation.
height after part number). See pg 82 for excavation details. 51
6. For Accessories (e.g. identification plates, divider brackets, cable hanger brackets see pg 43).

www.acoaus.com.au/cablemate
Product Selection Steps
,ENGTH MM L W Once pit type is determined:
Type 4 Pit 7IDTH MM D 5P TO
1. Determine if riser is required.
$EPTH MM  MM  RISER
2. Select lid or access cover (adds
additional depth) to suit project
application.

Lids

Steel PowerLok® lid (AS 3996 Class B).


Slip Resistance Rating R10 AS/NZS 4586.
IP2XD (AS 60529) protection against ingress of
foreign objects when hatch is closed.

Steel lid (AS 3996 Class B).


Slip Resistance Rating R10 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.

Cement concrete lid (AS 3996 Class A).


Slip Resistance Rating R9 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.
PLASTIC

Riser

Optional riser to increase pit depth,


riser rebate is identical to pit rebate
and with lid, offers the same IP Note: Access covers fit above pit/riser, refer to
protection. To produce riser, cut pg 80 for installation guidelines.
base off another pit to appropriate
length. ACO recommends no more
than 1 riser. Riser adds 300mm
depth.

Pit
Lids fit into rebate at top of pit, whilst access
covers must be installed in a cast in situ
concrete collar.

Continuous ribbed wall design for


maximum wall strength. All plastic
pits have undergone FEA analysis to
ensure optimum pit performance. Pit can be cut at specific points to create a
shallower pit.

Use holesaw to cut conduit Plastic pit construction offers an economic pit
hole anywhere on side wall. solution for light duty applications. Plastic also
The maximum number of holes offers excellent electrical resistivity.
recommended per pit is limited by
conduit quantity and size. Contact
ACO for guidance.

52
ACO CABLEMATE®

Weather Resistant
Access Covers
All access covers have IP4X (AS 60529)
protection against ingress of foreign
objects. Rhinocast® access covers offer
water & gas tightness to AS 3996.

Ductile iron Rhinocast®


Steel Urbanfil® solid top cover (AS 3996
recessed cover Class B)
(AS 3996 Class B) AS/NZS 4586 Slip Resistance
Rating R10

Ductile iron Rhinocast®


recessed cover
Steel Pavermate® (AS 3996 Class B)
recessed cover
(AS 3996 Class B)

Cast-in-situ Iron frame - external dim.


Cast-in-situ concrete collar 750 x 560 x 55mm
concrete collar Steel frame - external dim.
780 x 480 x 70mm

W
L

X D
Y

Z C
Type 4 Pit Parts List6
A Green area indicates
Description Part No. Weight (kg) B internal working area
Type 4 plastic pit 75957 12
Pit Dimensions
Lids & Covers Cover1 Total
Internal working area (mm)
Cement concrete lid (AS 3996 Class A) - Blank 75979 21 21
A 565
Cement concrete lid (AS 3996 Class A) - Communications 75983 21 21
B 260
Cement concrete lid (AS 3996 Class A) - Electricity 75990 21 21
C 450
Steel lid (AS 3996 Class B) 70420 11 11
X 605
Steel PowerLok® lid (AS 3996 Class B) 2, 3 70430 14 14
Y 300
Steel Urbanfil® recessed cover (AS 3996 Class B) 4 80450 11 16
Z 745
Steel Pavermate® recessed cover (AS 3996 Class B) 4 80451 11 17
Overall dimensions (mm)
Ductile iron Rhinocast® recessed cover (AS 3996 Class B) 5 85037 28 49
L 715
Ductile iron Rhinocast® solid top cover (AS 3996 Class B) 5 85236 28 47
W 410
Notes:
D 800
1. Lid & access cover weights are provided as lifting weight (individual cover parts) and total weight.
Recessed covers weight do not include pavement infill; for approx. lifting weight - Urbanfil®/ Notes:
Pavermate® covers - multiply weight by ‘7’; Rhinocast® covers multiply weight by ‘1.5’. 1. Using risers will increase pit depth (Z & D) by
2. All lids are supplied with brackets and support bars where applicable. depth of riser.
3. PowerLok® lids supplied with locking bolt (padlock not supplied). 2. Access covers will increase depth of pit by
4. Optional brass edging (Specify ‘BE’ after part number). height of concrete collar - allowance should be
5. Optional locking, brass or stainless steel edging in 12mm or 40mm heights (Specify ‘BE’ or ‘SS’ and made for concrete collar during pit installation.
height after part number). See pg 82 for excavation details. 53
6. For Accessories (e.g. identification plates, divider brackets, cable hanger brackets see pg 43).

www.acoaus.com.au/cablemate
Product Selection Steps
,ENGTH MM L W Once pit type is determined:
Type 5 Pit 7IDTH MM D 5P TO
1. Determine if riser is required.
$EPTH MM MM  RISER
2. Select lid or access cover (adds
additional depth) to suit project
application.

Lids

Steel PowerLok® lid (AS 3996 Class B).


Slip Resistance Rating R10 AS/NZS 4586.
IP2XD (AS 60529) protection against ingress of
foreign objects when hatch is closed.

Steel lid (AS 3996 Class B).


Slip Resistance Rating R10 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.

Cement concrete lid (AS 3996 Class A).


Slip Resistance Rating R9 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.
PLASTIC

Riser

Optional riser to increase pit


depth, riser rebate is identical
to pit rebate and with lid,
offers the same IP protection.
To produce riser, cut base Note: Access covers fit above pit/riser, refer to
off another pit to appropriate pg 80 for installation guidelines.
length. ACO recommends no
more than 1 riser. Riser adds
300mm depth.

Lids fit into rebate at top of pit, whilst access


Pit covers must be installed in a cast in situ
concrete collar.

Continuous ribbed wall design


for maximum wall strength. All
plastic pits have undergone
FEA analysis to ensure
optimum pit performance.

Pit can be cut at specific points to create a


shallower pit.

Use holesaw to cut conduit


hole anywhere on side wall.
The maximum number of holes
recommended per pit is limited Plastic pit construction offers an economic pit
by conduit quantity and size. solution for light duty applications. Plastic also
Contact ACO for guidance. offers excellent electrical resistivity.

54
ACO CABLEMATE®

Weather Resistant
Access Covers
All access covers have IP4X (AS 60529)
protection against ingress of foreign
objects. Rhinocast® access covers offer
water & gas tightness to AS 3996.

Steel Urbanfil® Ductile iron Rhinocast®


recessed cover solid top cover (AS 3996
(AS 3996 Class B) Class B)
AS/NZS 4586 Slip Resistance
Rating R10

Ductile iron Rhinocast®


Steel Pavermate®
recessed cover
recessed cover
(AS 3996 Class B)
(AS 3996 Class B)

Iron frame - external dim.


Cast-in-situ Cast-in-situ 750 x 560 x 55mm
concrete collar concrete collar
Steel frame - external dim.
780 x 480 x 70mm

W
L

X D
Y

Type 5 Pit Parts List6 Z C

Description Part No. Weight (kg)


A Green area indicates
Type 5 plastic pit 76042 10 B internal working area
Lids & Covers Cover1 Total
Pit Dimensions
Cement concrete lid (AS 3996 Class A) - Blank 76069 28 28
Internal working area (mm)
Cement concrete lid (AS 3996 Class A) - Communications 76073 28 28
A 585
Cement concrete lid (AS 3996 Class A) - Electricity 76080 28 28
B 335
Steel lid (AS 3996 Class B) 70520 11 11
C 285
Steel PowerLok® lid (AS 3996 Class B) 2, 3 70530 15 15
X 655
Steel Urbanfil® recessed cover (AS 3996 Class B) 4 80450 11 16
Y 355
Steel Pavermate® recessed cover (AS 3996 Class B) 4 80451 11 17
Z 580
Ductile iron Rhinocast® recessed cover (AS 3996 Class B) 5 85037 28 49
Overall dimensions (mm)
Ductile iron Rhinocast® solid top cover (AS 3996 Class B) 5 85236 28 47
L 715
Notes: W 465
1. Lid & access cover weights are provided as lifting weight (individual cover parts) and total weight.
Recessed covers weight do not include pavement infill; for approx. lifting weight - Urbanfil®/ D 635
Pavermate® covers - multiply weight by ‘7’; Rhinocast® covers multiply weight by ‘1.5’. Notes:
2. All lids are supplied with brackets and support bars where applicable. 1. Using risers will increase pit depth (Z & D) by
3. PowerLok® lids supplied with locking bolt (padlock not supplied). depth of riser.
4. Optional brass edging (Specify ‘BE’ after part number). 2. Access covers will increase depth of pit by
5. Optional locking, brass or stainless steel edging in 12mm or 40mm heights (Specify ‘BE’ or ‘SS’ and height of concrete collar - allowance should be
height after part number). made for concrete collar during pit installation.
6. For Accessories (e.g. identification plates, divider brackets, cable hanger brackets see pg 43). See pg 82 for excavation details. 55

www.acoaus.com.au/cablemate
Product Selection Steps
,ENGTH  MM L W Once pit type is determined:
Type 6 Pit 7IDTH MM D 5P TO
1. Determine if riser is required.
$EPTH MM MM  RISER
2. Select lid or access cover (adds
additional depth) to suit project
application.

Lids

Steel PowerLok® 2-part lid


(AS 3996 Class B).
Slip Resistance Rating R10
AS/NZS 4586.
IP2XD (AS 60529)
protection against ingress
of foreign objects when
hatch is closed.

Steel 2-part lid (AS 3996


Class B).
Slip Resistance Rating R10
AS/NZS 4586.
IP4X (AS 60529) protection
against ingress of foreign
objects if fitted with
universal plug.
Riser
Cement concrete 2-part lid
(AS 3996 Class A).
Slip Resistance Rating R9
PLASTIC

AS/NZS 4586.
IP4X (AS 60529) protection
against ingress of foreign Cast-in-situ
objects if fitted with universal concrete collar
plug.

Pit Note: Access covers fit above pit/riser, refer to


pg 80 for installation guidelines.

Optional riser to increase pit depth, riser rebate


is identical to pit rebate and with lid, offers
the same IP protection. To produce riser, cut
base off another pit to appropriate length. ACO
recommends no more than 1 riser. Riser adds
300mm depth.

Lids fit into rebate at top of pit, whilst access


covers must be installed in a cast in situ
concrete collar.

Pit can be cut at specific points to create a


shallower pit.

Plastic pit construction offers an economic pit


solution for light duty applications. Plastic also
offers excellent electrical resistivity.

Use holesaw to cut conduit hole anywhere


on side wall. The maximum number of holes Continuous ribbed wall design for maximum wall
recommended per pit is limited by conduit strength. All plastic pits have undergone FEA
quantity and size. Contact ACO for guidance. analysis to ensure optimum pit performance.

56
ACO CABLEMATE®

Weather Resistant
Access Covers
All access covers have IP4X (AS 60529)
protection against ingress of foreign
objects. Rhinocast® access covers offer
water & gas tightness to AS 3996.

Steel Urbanfil®
recessed 2-part Ductile iron Rhinocast®
cover (AS 3996 solid top 2-part cover
Class B) (AS 3996 Class B)
AS/NZS 4586 Slip
Steel Pavermate® Resistance Rating R10
recessed 2-part
cover (AS 3996
Class B) Ductile iron Rhinocast®
recessed 2-part cover
(AS 3996 Class B)

Cast-in-situ
concrete collar
Iron frame - external dim.
Steel frame - external dim.
1355 x 600 x 55mm
1450 x 580 x 70mm

W
L

X D
Y

Z C
Type 6 Pit Parts List6
A Green area indicates
Description Part No. Weight (kg) B internal working area
Type 6 plastic pit 75475 33
Pit Dimensions
Lids & Covers Cover1 Total
Internal working area (mm)
Cement concrete 2-part lid (AS 3996 Class A) - Blank 2 75010 33 69
A 1240
Cement concrete 2-part lid (AS 3996 Class A) - Communications 2 75011 33 69
B 430
Cement concrete 2-part lid (AS 3996 Class A) - Electricity 2 75012 33 69
C 320
Steel 2-part lid (AS 3996 Class B) 76820 15 31
X 1270
Steel PowerLok® 2-part lid (AS 3996 Class B) 2, 3 76830 20 39
Y 455
Steel Urbanfil® recessed 2-part cover (AS 3996 Class B) 4 82567 13 39
Z 615
Steel Pavermate® recessed 2-part cover (AS 3996 Class B) 4 82373 15 41
Overall dimensions (mm)
Ductile iron Rhinocast® recessed 2-part cover (AS 3996 Class B) 5 85433 30 91
L 1380
Ductile iron Rhinocast® solid top 2-part cover (AS 3996 Class B) 5 86853 28 89
W 565
Notes:
D 670
1. Lid & access cover weights are provided as lifting weight (individual cover parts) and total weight.
Recessed covers weight do not include pavement infill; for approx. lifting weight - Urbanfil®/ Notes:
Pavermate® covers - multiply weight by ‘7’; Rhinocast® covers multiply weight by ‘1.5’. 1. Using risers will increase pit depth (Z & D) by
2. All lids are supplied with brackets and support bars where applicable. depth of riser.
3. PowerLok® lids supplied with locking bolt (padlock not supplied). 2. Access covers will increase depth of pit by
4. Optional brass edging (Specify ‘BE’ after part number). height of concrete collar - allowance should be
5. Optional locking, brass or stainless steel edging in 12mm or 40mm heights (Specify ‘BE’ or ‘SS’ and made for concrete collar during pit installation.
height after part number). See pg 82 for excavation details. 57
6. For Accessories (e.g. identification plates, divider brackets, cable hanger brackets see pg 43).

www.acoaus.com.au/cablemate
Product Selection Steps
,ENGTH  MM L W Once pit type is determined:
Type 7 Pit 7IDTH MM D 5P TO
1. Determine if riser is required.
$EPTH  MM  MM  RISER
2. Select lid or access cover (adds
additional depth) to suit project
application.

Lids

Steel PowerLok® lid


(AS 3996 Class B).
Slip Resistance Rating R10
AS/NZS 4586.
IP2XD (AS 60529) protection
against ingress of foreign objects
when hatch is closed.

Steel lid (AS 3996 Class B).


Slip Resistance Rating R10
AS/NZS 4586.
IP4X (AS 60529) protection
against ingress of foreign objects
if fitted with universal plug.

Cement concrete 2-part


lid (AS 3996 Class A).
Slip Resistance Rating R9
Riser AS/NZS 4586.
IP4X (AS 60529) protection
PLASTIC

against ingress of foreign objects


if fitted with universal plug.

Cast-in-situ
concrete collar

Note: Access covers fit above pit/riser, refer to


pg 80 for installation guidelines.

Optional riser to increase pit depth, riser rebate


is identical to pit rebate and with lid, offers
Pit the same IP protection. To produce riser, cut
base off another pit to appropriate length. ACO
recommends no more than 1 riser. Riser adds
400mm depth.

Lids fit into rebate at top of pit, whilst access


covers must be installed in a cast in situ
concrete collar.

Pit can be cut at specific points to create a


shallower pit.

Plastic pit construction offers an economic pit


solution for light duty applications. Plastic also
offers excellent electrical resistivity.

Continuous ribbed wall design for maximum wall


Use holesaw to cut conduit hole strength. All plastic pits have undergone FEA
anywhere on side wall. The maximum analysis to ensure optimum pit performance.
58 number of holes recommended per pit is
limited by conduit quantity and size. Contact
ACO for guidance.
ACO CABLEMATE®

Weather Resistant
Access Covers
All access covers have IP4X (AS 60529)
protection against ingress of foreign
objects. Rhinocast® access covers offer
water & gas tightness to AS 3996.

Ductile iron Rhinocast®


solid top 2-part cover
(AS 3996 Class B)
AS/NZS 4586 Slip
Steel Urbanfil® Resistance Rating R10
recessed 2-part
cover (AS 3996
Class B)

Steel Pavermate® Ductile iron Rhinocast®


recessed 2-part recessed 2-part cover
cover (AS 3996 (AS 3996 Class B)
Class B)

Steel frame - external dim. Iron frame - external dim.


1300 x 730 x 70mm 1055 x 750 x 55mm

Cast-in-situ
concrete collar

W
L

X D
Y

Z C
Type 7 Pit Parts List6
A Green area indicates
Description Part No. Weight (kg) B internal working area
Type 7 plastic pit 76132 34
Pit Dimensions
Lids & Covers Cover1 Total
Cement concrete 2-part lid (AS 3996 Class A) - Blank 2 75155 23 49
Internal working area (mm)
A 865
Cement concrete 2-part lid (AS 3996 Class A) - Communications 2 75156 23 49
B 410
Cement concrete 2-part lid (AS 3996 Class A) - Electricity 2
75157 23 49
C 695
Steel lid (AS 3996 Class B) 70720 21 21
X 910
Steel PowerLok® lid (AS 3996 Class B) 2, 3 70730 24 24
Y 455
Steel Urbanfil® recessed 2-part cover (AS 3996 Class B) 4 82606 16 47
Z 1090
Steel Pavermate® recessed 2-part cover (AS 3996 Class B) 4 82398 17 48
Overall dimensions (mm)
Ductile iron Rhinocast® recessed 2-part cover (AS 3996 Class B) 5 85444 28 89
L 1020
Ductile iron Rhinocast® solid top 2-part cover (AS 3996 Class B) 5 80753 28 83
W 565
Notes:
D 1145
1. Lid & access cover weights are provided as lifting weight (individual cover parts) and total weight.
Recessed covers weight do not include pavement infill; for approx. lifting weight - Urbanfil®/ Notes:
Pavermate® covers - multiply weight by ‘7’; Rhinocast® covers multiply weight by ‘1.5’. 1. Using risers will increase pit depth (Z & D) by
2. All lids are supplied with brackets and support bars where applicable. depth of riser.
3. PowerLok® lids supplied with locking bolt (padlock not supplied). 2. Access covers will increase depth of pit by
4. Optional brass edging (Specify ‘BE’ after part number). height of concrete collar - allowance should be
5. Optional locking, brass or stainless steel edging in 12mm or 40mm heights (Specify ‘BE’ or ‘SS’ and made for concrete collar during pit installation.
height after part number). See pg 82 for excavation details. 59
6. For Accessories (e.g. identification plates, divider brackets, cable hanger brackets see pg 43).

www.acoaus.com.au/cablemate
Product Selection Steps
,ENGTH  MM L W Once pit type is determined:
Type 8 Pit 7IDTH MM D 5P TO
1. Determine if riser is required.
$EPTH MM MM  RISER
2. Select lid or access cover (adds
additional depth) to suit project
application.

Lids

Steel PowerLok® 2-part lid


(AS 3996 Class B).
Slip Resistance Rating R10
AS/NZS 4586.
IP2XD (AS 60529) protection
against ingress of foreign
objects when hatch is closed.

Steel 2-part lid (AS 3996 Class B).


Slip Resistance Rating R10
AS/NZS 4586.
IP4X (AS 60529) protection
against ingress of foreign
objects if fitted with
universal plug.

Riser
Cement concrete 2-part lid
(AS 3996 Class A).
PLASTIC

Slip Resistance Rating R9


AS/NZS 4586.
IP4X (AS 60529) protection Cast-in-situ
against ingress of foreign concrete collar
objects if fitted with universal
plug.

Note: Access covers fit above pit/riser, refer to


pg 80 for installation guidelines.
Pit
Optional riser to increase pit depth, riser rebate
is identical to pit rebate and with lid, offers
the same IP protection. To produce riser, cut
base off another pit to appropriate length. ACO
recommends no more than 1 riser. Riser adds
400mm depth.

Lids fit into rebate at top of pit, whilst access


covers must be installed in a cast in situ
concrete collar.

Pit can be cut at specific points to create a


shallower pit.

Plastic pit construction offers an economic pit


solution for light duty applications. Plastic also
offers excellent electrical resistivity.

Use holesaw to cut conduit hole anywhere


on side wall. The maximum number of holes Continuous ribbed wall design for maximum wall
recommended per pit is limited by conduit strength. All plastic pits have undergone FEA
quantity and size. Contact ACO for guidance. analysis to ensure optimum pit performance.

60
ACO CABLEMATE®

Weather Resistant
Access Covers
All access covers have IP4X (AS 60529)
protection against ingress of foreign
objects. Rhinocast® access covers offer
water & gas tightness to AS 3996.

Steel Urbanfil®
recessed 2-part Ductile iron Rhinocast®
cover (AS 3996 solid top 2-part cover
Class B) (AS 3996 Class B)
AS/NZS 4586 Slip
Steel Pavermate® Resistance Rating R10
recessed 2-part
cover (AS 3996
Class B) Ductile iron Rhinocast®
recessed 2-part cover
(AS 3996 Class B)

Cast-in-situ
concrete collar Iron frame - external dim.
Steel frame - external dim.
1355 x 600 x 55mm
1450 x 580 x 70mm

W
L

X D
Y

Z C
Type 8 Pit Parts List6
Description Part No. Weight (kg) A Green area indicates
B internal working area
Type 8 plastic pit 75018 42
Pit Dimensions
Lids & Covers Cover1 Total
Cement concrete 2-part lid (AS 3996 Class A) - Blank 2 75010 33 69 Internal working area (mm)
75011
A 1240
Cement concrete 2-part lid (AS 3996 Class A) - Communications 2 33 69
2
75012
B 430
Cement concrete 2-part lid (AS 3996 Class A) - Electricity 33 69
C 440
Steel 2-part lid (AS 3996 Class B)
Notes: 76820 15 31
1. Lid & access cover weights X 1270
Steel PowerLok ®
2-part lid (ASare provided
3996 ClassasB)total
2, 3 weight and lifting weight
76830(individual 20
cover parts)
39
* - Optional locking Y 455
Steel
For Urbanfil® (e.g.
Accessories recessed 2-part cover
identification (ASdivider
plates, Class B) 4 cable hanger82567
3996 brackets, brackets see 13 page XX 39
Z 835
Steel Pavermate® recessed 2-part cover (AS 3996 Class B) 4 82373 15 41
Overall dimensions (mm)
Ductile iron Rhinocast® recessed 2-part cover (AS 3996 Class B) 5 85433 30 91
L 1380
Ductile iron Rhinocast® solid top 2-part cover (AS 3996 Class B) 5 86853 28 89
W 565
Notes:
D 890
1. Lid & access cover weights are provided as lifting weight (individual cover parts) and total weight.
Recessed covers weight do not include pavement infill; for approx. lifting weight - Urbanfil®/ Notes:
Pavermate® covers - multiply weight by ‘7’; Rhinocast® covers multiply weight by ‘1.5’. 1. Using risers will increase pit depth (Z & D) by
2. All lids are supplied with brackets and support bars where applicable. depth of riser.
3. PowerLok® lids supplied with locking bolt (padlock not supplied). 2. Access covers will increase depth of pit by
4. Optional brass edging (Specify ‘BE’ after part number). height of concrete collar - allowance should be
5. Optional locking, brass or stainless steel edging in 12mm or 40mm heights (Specify ‘BE’ or ‘SS’ and made for concrete collar during pit installation.
height after part number). See pg 82 for excavation details. 61
6. For Accessories (e.g. identification plates, divider brackets, cable hanger brackets see pg 43).

www.acoaus.com.au/cablemate
Product Selection Steps
,ENGTH  MM L W Once pit type is determined:
Type 9 Pit 7IDTH MM D 5P TO
1. Determine if riser is required.
$EPTH MM  MM  RISER
2. Select lid or access cover (adds
additional depth) to suit project
application.

Lids

Steel PowerLok® 3-part lid


(AS 3996 Class B).
Slip Resistance Rating R10
AS/NZS 4586.
IP2XD (AS 60529) protection
against ingress of foreign objects
when hatch is closed.

Steel 3-part lid (AS 3996 Class B).


Slip Resistance Rating R10
AS/NZS 4586.
Riser IP4X (AS 60529) protection
against ingress of foreign objects
if fitted with universal plug.

Cement concrete 3-part lid


(AS 3996 Class A).
Slip Resistance Rating R9
PLASTIC

AS/NZS 4586.
IP4X (AS 60529) protection
against ingress of foreign objects
if fitted with universal plug.

Pit
Note: Access covers fit above pit/riser, refer to
pg 80 for installation guidelines.

Optional riser to increase pit depth, riser


rebate is identical to pit rebate and with lid,
offers the same IP protection. To produce
riser, cut base off another pit to appropriate
length. ACO recommends no more than 1
riser. Riser adds 400mm depth.

Lids fit into rebate at top of pit, whilst


access covers must be installed in a cast in
situ concrete collar.

Pit can be cut at specific points to create a


Continuous ribbed shallower pit.
wall design for maximum
wall strength. All plastic
pits have undergone FEA
analysis to ensure optimum
pit performance.
Plastic pit construction offers an economic
pit solution for light duty applications.
Use holesaw to cut conduit hole anywhere Plastic also offers excellent electrical
on side wall. The maximum number of holes resistivity.
recommended per pit is limited by conduit
quantity and size. Contact ACO for guidance.

62
ACO CABLEMATE®

Weather Resistant
Access Covers
All access covers have IP4X (AS 60529)
protection against ingress of foreign
objects. Rhinocast® access covers offer
water & gas tightness to AS 3996. Ductile iron Rhinocast®
solid top 3-part cover
(AS 3996 Class B)
AS/NZS 4586 Slip
Resistance Rating R10
Steel Urbanfil®
recessed 3-part
cover (AS 3996 Ductile iron Rhinocast®
Class B) recessed 3-part cover
(AS 3996 Class B)
Steel Pavermate®
recessed 3-part
cover (AS 3996
Class B)

Cast-in-situ
concrete collar

Cast-in-situ
Steel frame - external dim.
concrete collar
2020 x 580 x 70mm

Iron frame - external dim.


2005 x 600 x 55mm
W
L

X D
Y

Z C
Type 9 Pit Parts List6
A Green area indicates
Description Part No. Weight (kg) B internal working area
Type 9 plastic pit 75099 60
Pit Dimensions
Lids & Covers Cover1 Total
Internal working area (mm)
Cement concrete 3-part lid (AS 3996 Class A) - Blank 2 75235 38 118
A 1900
Cement concrete 3-part lid (AS 3996 Class A) - Communications 2 75236 38 118
B 430
Cement concrete 3-part lid (AS 3996 Class A) - Electricity 2
75237 38 118
C 440
Steel 3-part lid (AS 3996 Class B) 71920 15 45
X 1925
Steel PowerLok® 3-part lid (AS 3996 Class B) 2, 3 71930 20 58
Y 455
®
Steel Urbanfil recessed 3-part cover (AS 3996 Class B) 4
75109 13 56
Z 835
Steel Pavermate® recessed 3-part cover (AS 3996 Class B) 4 80951 15 58
Overall dimensions (mm)
Ductile iron Rhinocast® recessed 3-part cover (AS 3996 Class B) 5 80952 30 132
L 2035
Ductile iron Rhinocast® solid top 3-part cover (AS 3996 Class B) 5 80953 28 129
W 565
Notes:
D 890
1. Lid & access cover weights are provided as lifting weight (individual cover parts) and total weight.
Recessed covers weight do not include pavement infill; for approx. lifting weight - Urbanfil®/ Notes:
Pavermate® covers - multiply weight by ‘7’; Rhinocast® covers multiply weight by ‘1.5’. 1. Using risers will increase pit depth (Z & D) by
2. All lids are supplied with brackets and support bars where applicable. depth of riser.
3. PowerLok® lids supplied with locking bolt (padlock not supplied). 2. Access covers will increase depth of pit by
4. Optional brass edging (Specify ‘BE’ after part number). height of concrete collar - allowance should be
5. Optional locking, brass or stainless steel edging in 12mm or 40mm heights (Specify ‘BE’ or ‘SS’ and made for concrete collar during pit installation.
height after part number). See pg 82 for excavation details. 63
6. For Accessories (e.g. identification plates, divider brackets, cable hanger brackets see pg 43).

www.acoaus.com.au/cablemate
Product Selection Steps
Once pit type is determined:
Type 43 Pit $IAMETER MM
$EPTH MM
Dia
D MM 1. Select lid orif access
Determine riser is cover (adds
required.
2. additional depth)
Select lid or to suit
access project
cover (adds
application.
additional depth) to suit project
application.

Lids
Steel lid (AS 3996 Class B).
Slip Resistance Rating R10 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.
PLASTIC

Cement concrete lid (AS 3996 Class A).


Slip Resistance Rating R9 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.

Lids fit into rebate at top of pit, whilst access


covers must be installed in a cast in situ
concrete collar.

Pit

Pit has 3 x 100mm dia holes spaced equidistant near


the base. Use holesaw to cut conduit hole anywhere
else on side wall. The maximum number of holes
recommended per pit is limited by conduit quantity and
size. Contact ACO for guidance. Plastic pit construction offers an economic pit
solution for light duty applications. Plastic also
offers excellent electrical resistivity.

64
ACO CABLEMATE®

Weather Resistant
Access Covers
If access cover required contact ACO.

W
Y

D Z
Type 43 Pit Parts List2
Description Part No. Weight (kg)
Type 43 plastic pit 74308 5
Lids & Covers Cover1 Total B Green area indicates
internal working area
Cement concrete lid (AS 3996 Class A) - Blank 76221 18 18 Pit Dimensions
Cement concrete lid (AS 3996 Class A) - Communications 74592 18 18
Internal working area (mm)
Cement concrete lid (AS 3996 Class A) - Electricity 74312 18 18 B 280
Steel lid (AS 3996 Class B) 74320 6 6 Y 340
Notes: Z 545
1. Lid weights are provided as lifting weight (individual cover parts) and total weight.
Overall dimensions (mm)
2. For Accessories (e.g. identification plates, divider brackets, cable hanger brackets see pg 43).
W 430
D 610
Notes:
See pg 82 for excavation details.

65

www.acoaus.com.au/cablemate
Product Selection Steps
,ENGTH MM L W Once pit type is determined:
Type 53 Pit 7IDTH MM D
MM 1. Select lid orif access
Determine riser is cover (adds
required.
$EPTH MM
2. additional depth)
Select lid or to suit
access project
cover (adds
application.
additional depth) to suit project
application.

Lids

Steel lid (AS 3996 Class B).


Slip Resistance Rating R10 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.
PLASTIC

If a locking lid is required, please contact ACO.

Polymer concrete lid (AS 3996 Class A).


Slip Resistance Rating R10 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.

Lids fit into rebate at top of pit, whilst access


covers must be installed in a cast in situ
concrete collar.

Pit

Use holesaw to cut conduit hole anywhere on side


wall. The maximum number of holes recommended
per pit is limited by conduit quantity and size.
Contact ACO for guidance.

Plastic pit construction offers an economic pit


solution for light duty applications. Plastic also
offers excellent electrical resistivity.

66
ACO CABLEMATE®

Weather Resistant
Access Covers
If access cover required contact ACO.

W
L

X D
Y
Type 53 Pit Parts List2
Z C
Description Part No. Weight (kg)
Type 53 plastic pit 75785 3
A Green area indicates
Lids & Covers Cover1 Total B internal working area
Polymer concrete lid (AS 3996 Class A) - Blank 75806 6 6 Pit Dimensions
Polymer concrete lid (AS 3996 Class A) - Communications 75813 6 6
Internal working area (mm)
Polymer concrete lid (AS 3996 Class A) - Electricity 75829 6 6 A 330
Steel lid (AS 3996 Class B) 75320 4 4 B 155
Notes: C 155
1. Lid weights are provided as lifting weight (individual cover parts) and total weight.
2. For Accessories (e.g. identification plates, divider brackets, cable hanger brackets see pg 43).
X 460
Y 215
Z 430
Overall dimensions (mm)
L 540
W 295
D 455
Notes:
See pg 82 for excavation details.

67

www.acoaus.com.au/cablemate
Product Selection Steps
,ENGTH MM L W Once pit type is determined:
Type 55 Pit 7IDTH MM D MM  RISER 1. Determine if riser is required.
$EPTH MM
2. Select lid or access cover (adds
additional depth) to suit project
application.

Lids

Steel PowerLok® lid (AS 3996 Class B).


Slip Resistance Rating R10 AS/NZS 4586.
IP2XD (AS 60529) protection against ingress of
foreign objects when hatch is closed.
(Fitting instructions are supplied with lid.)

Steel lid (AS 3996 Class B).


Slip Resistance Rating R10 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.

Polymer concrete lid (AS 3996 Class A).


Slip Resistance Rating R10 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.
PLASTIC

Riser

Optional riser to increase pit depth,


riser rebate is identical to pit Note: Access covers fit above pit/riser, refer to
rebate and with lid, offers the same pg 80 for installation guidelines.
IP protection. To produce riser, cut
base off another pit to appropriate
length. ACO recommends no more
than 1 riser. Riser adds 150mm
depth.

Pit Lids fit into rebate at top of pit, whilst access


covers must be installed in a cast in situ
concrete collar.

Use holesaw to cut conduit


hole anywhere on side wall.
The maximum number of holes Plastic pit construction offers an economic pit
recommended per pit is limited by solution for light duty applications. Plastic also
conduit quantity and size. Contact offers excellent electrical resistivity.
ACO for guidance.

68
ACO CABLEMATE®

Weather Resistant
Access Covers
All access covers have IP4X (AS 60529)
protection against ingress of foreign
objects. Rhinocast® access covers offer
water & gas tightness to AS 3996.

Ductile iron Rhinocast®


solid top cover (AS 3996
Steel Urbanfil® recessed Class B)
cover (AS 3996 Class B) AS/NZS 4586 Slip Resistance
Rating R10

Ductile iron
Steel Pavermate® Rhinocast®
recessed cover recessed cover
(AS 3996 Class B) (AS 3996 Class B)

Steel frame - external dim. Cast-in-situ


730 x 730 x 70mm concrete collar
Cast-in-situ
concrete collar
Iron frame - external dim.
750 x 710 x 55mm

L W

Y X D
Z
6
Type 55 Pit Parts List
Description Part No. Weight (kg) B A Green area indicates
internal working area
Type 55 plastic pit 76253 6
Pit Dimensions
Lids & Covers Cover1 Total
Polymer concrete lid (AS 3996 Class A) - Blank 76279 19 19 Internal working area (mm)
A 365
Polymer concrete lid (AS 3996 Class A) - Communications 76285 19 19
B 365
Polymer concrete lid (AS 3996 Class A) - Electricity 76297 19 19
X 450
Steel lid (AS 3996 Class B) 75520 13 13
Y 450
Steel PowerLok® lid (AS 3996 Class B) 2, 3 75530 17 17
Z 450
Steel Urbanfil® recessed cover (AS 3996 Class B) 4 81565 15 22
Overall dimensions (mm)
Steel Pavermate® recessed cover (AS 3996 Class B) 4 81948 18 24
L 560
Ductile iron Rhinocast® recessed cover (AS 3996 Class B) 5 85045 36 60
W 560
Ductile iron Rhinocast® solid top cover (AS 3996 Class B) 5 85222 35 63
D 505
Notes:
1. Lid & access cover weights are provided as lifting weight (individual cover parts) and total weight. Notes:
Recessed covers weight do not include pavement infill; for approx. lifting weight - Urbanfil®/ 1. Using risers will increase pit depth (Z & D) by
Pavermate® covers - multiply weight by ‘7’; Rhinocast® covers multiply weight by ‘1.5’. depth of riser.
2. All lids are supplied with brackets and support bars where applicable. 2. Access covers will increase depth of pit by
3. PowerLok® lids supplied with additional fitting instructions and locking bolt (padlock not supplied). height of concrete collar - allowance should be
4. Optional brass edging (Specify ‘BE’ after part number). made for concrete collar during pit installation.
5. Optional locking, brass or stainless steel edging in 12mm or 40mm heights (Specify ‘BE’ or ‘SS’ and See pg 82 for excavation details.
height after part number). 69
6. For Accessories (e.g. identification plates, divider brackets, cable hanger brackets see pg 43).

www.acoaus.com.au/cablemate
Product Selection Steps
,ENGTH MM L W Once pit type is determined:
Type 77 Pit 7IDTH MM D 5P TO
1. Determine if riser is required.
$EPTH MM MM  RISER
2. Select lid or access cover (adds
additional depth) to suit project
Lids application.

Steel PowerLok® lid (AS 3996 Class B).


Slip Resistance Rating R10 AS/NZS 4586.
IP2XD (AS 60529) protection against ingress of
foreign objects when hatch is closed.
(Fitting instructions are supplied with lid.)

Steel lid (AS 3996 Class B).


Slip Resistance Rating R10 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.

Polymer concrete lid (AS 3996 Class A).


Slip Resistance Rating R10 AS/NZS 4586.
IP4X (AS 60529) protection against ingress of
foreign objects if fitted with universal plug.

Risers
PLASTIC

Optional risers to
increase pit depth, riser
rebate is identical to pit
rebate and with lid, offers
the same IP protection.
To produce plastic riser,
cut base off another pit
to appropriate length. Note: Access covers fit above pit/riser, refer to
ACO recommends no pg 80 for installation guidelines.
more than 1 riser. Plastic
riser adds 200mm depth.
Polymer concrete riser
adds 300mm depth.

Pit

Lids fit into rebate at top of pit, whilst access


covers must be installed in a cast in situ
concrete collar.

Use holesaw to cut conduit


hole anywhere on side wall.
The maximum number of holes
recommended per pit is limited
by conduit quantity and size.
Contact ACO for guidance. Plastic pit construction offers an economic pit
solution for light duty applications. Plastic also
offers excellent electrical resistivity.

70
ACO CABLEMATE®

Weather Resistant
Access Covers
Ductile iron Rhinocast®
All access covers have IP4X (AS 60529) solid top cover (AS 3996
Class B)
protection against ingress of foreign
AS/NZS 4586 Slip Resistance
objects. Rhinocast® access covers offer Rating R10
water & gas tightness to AS 3996.

Ductile iron Rhinocast®


recessed cover
Steel Urbanfil® recessed (AS 3996 Class B)
cover (AS 3996 Class B)

Steel Pavermate®
recessed cover
(AS 3996 Class B)

Steel frame - external dim.


880 x 880 x 70mm Cast-in-situ
Cast-in-situ concrete collar
concrete collar

Iron frame - external dim.


900 x 860 x 55mm

L W

Y X D
Type 77 Pit Parts List6 Z

Description Part No. Weight (kg)


B A Green area indicates
Type 77 plastic pit 76344 13 internal working area
Type 77 polymer concrete riser (adds 300mm to pit depth) 76368 47 Pit Dimensions
Lids & Covers Cover1 Total
Internal working area (mm)
Polymer concrete lid (AS 3996 Class A) - Blank 76382 31 31 A 465
Polymer concrete lid (AS 3996 Class A) - Communications 76396 31 31 B 465
Polymer concrete lid (AS 3996 Class A) - Electricity 76409 31 31 X 600
Steel lid (AS 3996 Class B) 77720 20 20 Y 600
Steel PowerLok® lid (AS 3996 Class B) 2, 3 77730 25 25 Z 605
Steel Urbanfil® recessed cover (AS 3996 Class B) 4 81601 24 32 Overall dimensions (mm)
Steel Pavermate® recessed cover (AS 3996 Class B) 4 81372 25 33 L 710
Ductile iron Rhinocast® recessed cover (AS 3996 Class B) 5 85061 60 87 W 710
Ductile iron Rhinocast® solid top cover (AS 3996 Class B) 5 85274 60 91 D 660
Notes: Notes:
1. Lid & access cover weights are provided as lifting weight (individual cover parts) and total weight. 1. Using risers will increase pit depth (Z & D) by
Recessed covers weight do not include pavement infill; for approx. lifting weight - Urbanfil®/ depth of riser.
Pavermate® covers - multiply weight by ‘7’; Rhinocast® covers multiply weight by ‘1.5’. 2. Access covers will increase depth of pit by
2. All lids are supplied with brackets and support bars where applicable. height of concrete collar - allowance should be
3. PowerLok® lids supplied with additional fitting instructions and locking bolt (padlock not supplied). made for concrete collar during pit installation.
4. Optional brass edging (Specify ‘BE’ after part number). See pg 82 for excavation details.
5. Optional locking, brass or stainless steel edging in 12mm or 40mm heights (Specify ‘BE’ or ‘SS’ and
71
height after part number).
6. For Accessories (e.g. identification plates, divider brackets, cable hanger brackets see pg 43).

www.acoaus.com.au/cablemate