You are on page 1of 1

天津智易时代科技发展有限公司

TIANJIN ZWINSOFT TECHNOLGY CO.,LTD


Calibration report

Results of Calibration
1.Inspection : Qualified
2.Numerical calibration:

Normative References HJ653 、HJ654、Q/ZWIN010-2022

Calibration
Number 20240113080001 2024.01.13
Date

Standard
Serial Technical
Product Substance Test Result Conclusion
Number Requirement
Concentration
Zero Gas Indication 1.290PPM
1 TVOC error : Qualified
16 PPM 14.633 PPM
±20%FS
Zero Gas Indication 109
SO2
2 error : Qualified
(ug/m3) 7140 7194
±10%FS
Zero Gas Indication 1.47
CO
3 error : Qualified
(mg/m3) 12.5 13.1
±10%FS
410.5 Indication 403.6
CO2
4 error : Qualified
(mg/m3) 805.3 826.3
±10%FS
Zero Gas Indication 42
NO2
5 error : Qualified
(ug/m3) 5130 5186
±10%FS
Zero Gas Indication 0.176 PPM
6 NH3 error : Qualified
80 PPM ±20%FS 76.359 PPM

PM10 235.3 Parallelism : 248.9


7 Qualified
(ug/m3) 865.9 ±20% 894.2

TSP 603.5 Parallelism : 630.3


8 Qualified
(ug/m3) 1512.7 ±20% 1531.5

9 TEMPERATURE 29.3 ≤±3℃ 30.1 Qualified

10 HUMIDITY 45.3 ≤±3%RH 44.6 Qualified

11 PRESSURE 100.6 ≤±1KPa 100.6 Qualified