You are on page 1of 1

RING FLEXIBILITY TEST REPORT

Test Sr.No. 2142 Test Date 31/08/2023


Test Time 14:50:53
Customer Name DANCO CAPITAL LIMITED
Customer Code 1
Operator Name CALIST

Sample Details
Specimen code RF
Ref. Standard ISO 9969
Pipe OD 167.00 Pipe Length 300.00
Pipe ID 150.00 Thickness 8.50
Speed of testing (mm/min) 5
*All dimension in mm
Graph View

Obtained Results
Sr. No. Results Value
1 FORCE AT 30% DEFLECTION 1.20 KN
2 30% DEFLECTION IN mm 50.30 mm

Remarks
PASS