CONTROLS PTT FEATURES RELAY CONTROL INFORMATION High coolant temperature alarm High coolant temperature shutdown Low coolant temperature alarm Low oil pressure alarm Low oil pressure shutdown Overspeed shutdown Overerank shutdown Engine control switch not in automatic or start position * Diagnostic fault indication on engine control module RELIABLE COMMUNICATION * Links with engine control module via three- wire system (B+, B-, serial data link) GOLD-PLATED SILVER RELAY CONTACTS * Provide low contact resistance for switching low level external signals ACTIVATED RELAYS REMAIN ENERGIZED ‘© Until alarms clear or shutdowns are reset ISOLATED RELAY CONTACTS * Voltage-free, normally closed or normally open contacts for external controls RELAY CONTACTS INDIVIDUALLY FUSED * Protect against damage in event of external system fault INTERNALLY PROTECTED ELECTRONIC CONTROL ‘= Protected against overvoltage, incorrect wiring, or reverse polarity EMCP CUSTOMER INTERFACE MODULE (CIM) The Customer Interface Module (CIM) provides contacts for custom remote annunciation of status signals from the EMCP Il and EMCP Il+. The CIM consists of an electronic control and @ relay assembly board. The electronic control converts serial data link information to activate relays on the relay assembly board. The relay assembly board contains nine separate relays for custom application. RELAY TEST * Customer selectable option at installation. Allows relay test via lamp test switch on engine control module. ‘SELF-DIAGNOSTIC All relays turn off and on at two-second intervals if serial data link signal is lost SPECIFICATIONS PHYSICAL DATA Epoxy encapsulated block electronic control Size —mm (in) .. 173 x 118 x 36 (6.8 x 4.6 x 1.4) Weight— kg (Ib) 1.6 (35) Vinyl plastic relay track Size —mm (in). . 333 x 73.2 x 34 (13.1 x 2.9 x 1.3) Weight —kg (Ib) 0.4 (0.9) ENVIRONMENTAL Ambient temperature range "CFD -40 to +65 (-40 to 149) ELECTRICAL DATA Input operating voltage — vde Electronic assembly . Relay board .. -24 (nominal) Power — watts 18 max (in relay test mode) Relay contact rating. ...24 VDC/120 VAC @ 1.0 A Contact fuse — ampere ...eeseesveeeeeeee 1 Electronic control terminals — mm (in) male blade (two terminalsiconnection). . 6.4 (.25) User connections at relay board 6-32 screw terminals Electronically isolated and capable of operating with or without earth ground 2.18 to 45 WHERE THE WORLD TURNS FOR POWER ne UT INSTALLATION ELECTRONIC CONTROL MODULE Relay assembly board must be mounted in a es clean, dry environment on a rigid, non-vibrating surface, Vertical surface mounting within an enclosure is preferred, Electronic control is to be in close proximity to the relay board, Interconnect wire harness with 610 mm (24.0 in) leads is included. fs ws we User wiring between the generator terminal box TRAD RE LOOT GE and CIM should be stranded conductor with a maximum length of 305 m (1000 ft). Wires B+ t and B- are to be minimum size 12 AWG, Serial q data link wiro is to bo a shielded type, 18 AWG i minimum, Routing of wiring should avoid combining with Tee [ees Tyno we [EsSamnsraaee potential sources of electrical noise SS fishes Siit| ten nace Note: Dimensions ar in nm, ss ig [Eoin RELAY BOARD ASSEMBLY —! Y9RVVY P9 00R. WIRING DIAGRAM erie

You might also like