A 22-year-old male patient visited the clinic for lens delivery regarding the
prescription given two months ago: Rose K2 XL/7.8/14.6/-1.50DS for the right
eye (RE) and Menicon Tinu/8.1/9.4/-2.00DS for the left eye (LE). The patient
was diagnosed with keratoconus in the RE. He reported experiencing dry eyes,
particularly when using a phone and in air-conditioned areas. Currently
wearing spectacles that are four years old, with noticeable scratches and mild
peeling. Despite this, general health is considered unremarkable.

VISUAL ACUITY
ANTERIOR HEALTH ASSESSMENT (with LENS ON)
G1 MGB on BE
G0.5 papillae on BE RE: -1.50DS (6/9-3,PH:6/6-3)
G2 corneal staining on RE LE: -2.00DS (6/6,+1.00:6/18)
TBUT values were 4s on RE and 3s on LE CORNEAL TOPOGRAPHY
Tear prism is 0.5mm on BE.
(with LENS ON)
RE: 41.22/42.00@84º
CA: 0.78x174º
LE: 39.78/40.14@128º
CA: 0.36x38º
RE LE
OVER REFRACTION
RE: pL (6/6)
LE: pL (6/6)

FITTING ASSESSMENT
(0,0) = Centration = (0,-0.8)
0.5mm = Movement with blinking = 0.5mm
Smooth = Movement type = Smooth
Moderate = Speed of movement = Moderate
Diffuse = Central = Diffuse
Diffuse = Mid peripheral = Diffuse
>1mm = Edge clearance = 0.5
4/5 = Comfort rating = 4/5
Three Point Touch = Fitting classification = Alignment

DIAGNOSIS/FINDINGS
1. Keratoconus on RE
2. Suitable to wear contact lens due to no ocular health issue
3. Dry eyes
4. Fitting is optimum on BE
MANAGEMENT
Pt was advised to wear the sem-scleral lens as it may reduce the higher-order aberrations
He was advised to use artificial tears (Systane Hydration) 3-4 times a day to lubricate cornea.
The lens was delivered to patient:-
RE: Rose K2 XL/7.8/14.6/- 1.50DS
LE: Menicon Tinu/8.1/9.4/-2.00DS.
Prescribed lens care was Menicon Menicare Plus (MPS), Opticare saline, Progen enzymatic
cleaner and B&L Rewetting drops.
Re-educate pt on lens insertion, removal and care maintenance.
TCA 1 month for aftercare assessment.

DISCUSSION
Aspheric back optic zone which decreases as BC steepens.
Front surface aberration control.
Precise edge lift control.
Reverse geometry in flatter base curves.

ROSE K2 XL

THREE POINT TOUCH


-Gentle ‘touch’ on cone Menicon Tinu GP lens
apex
-Dark area should The aspherical back surface
fluoresce each blink of GP lenses may not conform
-Mid-peripheral bearing at well to the spherical cornea,
potentially causing the lens to
both side
displace downwards.
-Atleast 0.7 mm edge
clearance