MICROWAVE PERFORMANCE
MONITORING SERVICE
KNOWLEDGE TRAINING
Contents
1. Performance of Microwave Device
1.1 NE Performance
1.2 RMON Performance
2. Performance Management System
3. Troubleshooting for PMS issue
Difference:
1. SDH/IF performance is biased towards counting and RMON performance is biased towards
measurement, so the indicator is different.
2. Different standard, SDH/IF performance is refer: G.784 and G.874, RMON performance is refer
IETF RFC2819.
3. SDH/IF performance support Current Performance, RMON performance support real time
performance. So what’s will happen at PMS instance?
4. Different function entry at NCE
The history control group is used to configure the parameters of the history group, including whether to
enable the history group and the period of the history group. (There are four 30s and 30 minutes in total.
Period 1 and period 2 can be set, similar to the 15-minute or 24-hour period of G.784.) Duration for storing
historical group
Alarm group, which is used to configure performance thresholds and enable the generation of threshold-
crossing reports. For the PTN equipment, the PTN equipment combines the history control group and
alarm group into the RMON setting.
Fix items
7. Right click PMS instance->Instance Diagnose->View/Repair Abnormality
8. Right click PMS instance->Suspend Monitoring->Resume Monitoring
9. Right click PMS instance->Synchronize Resource
Logs collection:
PMSservice
PMSCollectService
NemgrTransService