You are on page 1of 4
©e@ walla hiv Ahakti FABRICATORS Doons FOR LIFE i er 8 476 PART 20 & 22, Bult Resistance Doors, Clean Room Doors, Acoustic Doors, Sliding Doors Molo Metal Pressed Stel Doors & Door Frames, Hollow Mell Pressed see! Window & Window Frames, Stal Window MANUFACTURER TEST CERTIFICATE This is to certify that, 14NOS. of 46mm Thick shutter & frame of 100mm x 57mm 120minutes Fire Rated Steel Doors supplied with hardware to M/s SDCE PROJECTS PVT LTO, RELIANCE 'NDUSTRIES, NANDESARI, VADODARA, GUJARAT. As per BS 476 PART 20 & 22 AND IS 3614 PART -2 ‘manufactured similar to the prototype sample tested & certified earlier at CBRI, ROORKEE. Enclosed, please find the certified true copy of Test Report Ref. No. FR/0261, DT. January 13, 2022 from CBRI, ROORKEE. itis further confirmed that, the Fire Rated Steel Doors are supplied by us carries a Warranty Period of 1 years from the date of supply, against any of the manufacturing defects. INVOICE DETAILS: ‘SRNO. INVOCENO.& | PROJECT NAME | ITEM any. DATE 1 114 & 14-07-2023 | SDCE PROJECTS | STEEL FIRE DOORS | 06 NOS. PVTLTD, DOUBLE LEAF RELIANCE Doors. INDUSTRIES, NANDESARI, VADODARA, GUJARAT oe 114 & 14-07-2023 | SDCE PROJECTS | STEEL FIRE DOORS | 08 NOS. PVTLTD, SINGLE LEAF RELIANCE boors. INDUSTRIES, NANDESARI, VADODARA, GUJARAT DT. 09-12-2023, On MeRs a tcl RUN Tey FOR, SHIV SHAKTI FABRICATORS ala Estate, S,P.Ring Road, NrKathwada G.I.D.C., Anmedabad-3E info@shivshaktifabricators.in +91-98989 26545, +91-90167 26139 TEST SCHEDULE 1/1 (Reference No. ~ FR /0261) 1. Name of the Laboratory + Fire Research Laboratory CSIR-Central Building Research Institute, Roorkee-247 667 2. Name of the Sponsorer : IWS Shiv Shakti Fabricators, Plot No. C/3B, Madhuram Industrial Estate, B/S, Vishala Estate, opp, Marigild Restrauant, Neat Kathwada GILD.C., §.P.Ring Road, Ahmedabad-382 439 3. Name of the Test 4. Date of Test : Fire Resistance Test : January 13, 2022 5. Ambient Temperature 313°C 6. Fire Exposure + As per BS:476 (Part 20 & 22)-1987, 18:3614(Part-2)-1992 T- Applicability of Test Criteria: Stablty - Yes arn i Integrity : Yes Insulation: No 8. Specimen Details # Single Leaf Single Swing G.1. Composite Fire Door with Vision Panel Size Door Frame Door Panel Height 2400 mm 2350 mm Wicih 1200 mm 1116 mm ‘Thickness: 100mm. 46mm &. Specimen Construction 7S As shown in Fi iguro 1 and Figure 2 {Drg. No. 11 ~0261 (1) and Brg No. 1/1-0261(2)) 10. Door Type + Uninsulated 11. Door Installation + Opens outwards the furnace chamber 12. Intended Test Duration 2120 Minutes Test Results Lancia of the evaluation reveals that the single let single swing G.1. composite re Boe {20 minty (on sien Banel specimen has been found to Be able te wehstenn tafdard fire for {0 mintes (Ong pundred twenty minutes only) wif aspect Steed integ#lty only. Qy Spt Vn Ls Jaye Y 4 (Rajeev Bansal) (Sufi kumar) i 2 aj EXPOSED FACE i : ZL LLL 1.6 mm Thick, 6. Hoes Shea Dio Fane OP View (seerion AT X-X) (15x2) Intumescent Strip at oe Fane 1200 Door Closer ae (Gere) if 7 T T rs SS. Ball Bearing” | Hinges -05 Nos (Gees) \ i Vision Panel, 6 tek clear glass (echo Byran) ‘ " F - so|| Z i i at Latch Leck Operate b4o0 fom bo sie (Gere) : 2 1 220 @ x| x i tobe + | 3 1 1040 7 i = 8 ee i | ol & [zy ' lg] £ |g u ret (8) BS Y= ALL DIMENSIONS ARE IN FRONT VIEW ALL DIMENSIG Fig. 1: Construction details of Single Leaf Single Swing G.1. Composite Fire Door (Uninsulated) specimen evaluated for Fire Resistance on January 13, 2022. SiSer Stayeverrer ceteris: FIRE RESEARCH aa J CBRL | SRE csiR W.wa.sng ome, - day Note : This original on 's valid. Third parties using copies are doing so at their own risk (5x2) Intumescent Strip at Frame ——1 o0— | ie f 46 (15x2) inturescent Strip at Frame ‘6mm Thick, Gi ‘Sheet Door Frame Nee ‘Sheet Door Panel EXPOSED FACE Z Details at y DRG NO] 11-0261) y 7 y ORWN. By eae 7 [ono ey | If 7 ALL DIMENSIONS ARE IN MM, Y SCALE -N.T.S. / REF. -FIG.1 END VIEW (SECTION AT 'Y-Y) Fig, 2: Sectional details of Single Leaf Single Swing G.1. Composite Fire Door (Uninsulated) specimen evaluated for Fire Resistance on January 13, 2022. slider sieisterst Geiser “~~ FIRE RESEARCH-LABORATORY

You might also like